The Irradiation test of bar code label tagged on radioactive waste container was done to determine the effect of radiation. Low and medium radioactive waste is that below total activity of 4,000 Bq/g according to the Korean nuclear law. The irradiation amount to radiate bar code label tagged on radioactive waste container was calculated by MCNP-4b computer code. The nuclide such as Co-60 and Cs-137 was assumed to contribute 50% of total activity. Real irradiation amount for bar code label was finally calculated by the dimensions of the container and the bar code label. The Identification of post and the physical deflection of irradiated bar code label was tested by the bar code reader. The coated bar code label was suitable to use on low and medium radioactive waste container.

바코드 라벨의 방사선 조사 시험은 방사성폐기물 용기에 부착할 바코드 라벨의 방사선 환경 하에서의 영향을 판단하기 위하여 수행하였다. 중$\cdot$저준위 방사성 폐기물은 원자력법에 의하면 총 방사능량이 4,000 Bq/g 미만을 말한다. 방사성 폐기물 용기의 외부에 부착할 바코드 라벨이 받게 되는 방사선 조사선량은 MCNP-4b Computer Code에 의하여 계산하였다. Co-60과 Cs-137 핵종들은 총 방사능에 50%씩 기여한다고 가정하였다. 용기와 바코드 라벨의 제원에 의하여 실제의 최종 방사선 조사선량을 계산하였다. 바코드 판독기를 이용하여 바코드 라벨의 인식률과 외관점검을 수행한 결과 코팅된 바코드 라벨은 중$\cdot$저준위 방사성 폐기물 용기에 사용하기에 적합하였다.