• Title/Summary/Keyword: 방사선센서

Search Result 232, Processing Time 0.027 seconds

Radiation resistant Characteristics of Fiber Bragg Grating Sensors made with 800-nm femtosecond laser (800nm급 펨토초 레이저로 제작된 FBG 센서의 내방사선 특성)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu;Sohn, Ik-Bu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.711-713
    • /
    • 2017
  • Fiber Brag grating sensors were written in standard Ge-doped telecom optical fiber (Corning SMF-28) using an 800nm femtosecond laser and a phase mask. It were exposed to gamma-radiation up to a dose of 100 kGy to evaluate the radiation effect. The fs-FBG-2 sensor showed incomplete optical characteristics during irradiation, but the fs-FBG-1 sensor showed excellent radiation resistance with Bragg wavelength shift(BWS) of less than 10pm at a dose of 100 kGy.

  • PDF

High speed 3D position detection of radiation using CCD camera (CCD 카메라를 이용한 방사선원 3차원 위치 고속 측정기)

  • Lee, Nam-Ho;Kim, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.433-435
    • /
    • 2005
  • 광변환 물질을 사용하여 X-선이나 감마방사선을 가시광으로 변환한 다음 CCD 카메라를 통하여 광량을 측정하면 방사선의 양을 간접적으로 측정할 수 있다. 본 연구에서는 CCD형 비상대용 로봇용 고속 삼차원 방사선 위치 탐지장치에서 방사선 위치 센싱의 핵심 역할을 수행하는 CCD 방사선 탐지부를 간접 방사선 측정 방법을 응용하여 고안하고 구현한 다음 이에 대한 방사선 특성시험을 수행하였다. 시험 결과로 부터 구현한 CCD형 방사선 센서가 방사선 위치 및 선량 탐지장치로 활용 가능성이 충분함 확인하였다.

  • PDF

A design of radiation hardened common signal processing module for sensors in NPP (내방사선 원전센서 공통 신호처리 모듈 설계)

  • Lee, Nam-ho;Hwang, Young-gwan;Kim, Jong-yeol;Lee, Seung-min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.6
    • /
    • pp.1405-1410
    • /
    • 2015
  • In this study we designed the radiation-hardened sensor signal processing modules that can be commonly used for a variety of sensors during normal operation and even in high-radiation environments caused by an accident. First development module was designed to receive the change of the R and C value from the sensors and to process the signal as a PWM modulation scheme. This module was assessed to have ± 10% error to the Full-Scale in the radiation test in the range of 12 kGy TID. The main cause of the error was analyzed as the annealing of the common circuit in the switching element and the consequent increase in the duty ratio of the pulse width modulation circuit according to the radiation dose increasement. The redesigned module for higher radiation resistivity with Stub transistor circuit was found to have less than 5% error to the Full-scale from the radiation test results for 20.7 kGy TID range.

A Study on Characteristics of A Diode Radiation Sensor for Portal Image of Therapy Radiation (치료방사선 Portal Image를 위한 다이오드 방사선 센서의 특성에 관한 연구)

  • Lee, Dong-Hun;Kwon, Jang-Woo;Hong, Seung-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.11-20
    • /
    • 1996
  • In this paper, the characteristics of therapy radiation diode sensors have been studied by using therapy radiation from the MM22 microtron accelerator. The linearity, reproducibility and error ratio were measured for feasibility as a radiation detector. Energy dependence, sensitivity change after a amount of irradiation and output value according to a number of diodes were also measured for same purpose. We have formed pulse shaping of diode signal with nuclear instruments for portal image reconstruction. The percent depth dose ratio according to field size and depth was compared with that of the detector of a ion chamber. Using thirteen silicon diodes, we can directly read diode outputs on a computer monitor after A/D conversion with 16 channels analog to digital conversion board with 12 bit resolution. The possibility for portal image with diodes has been suggested from output comparison between output value with a human phantom and that without a human phantom.

  • PDF

Fabrication and characteristics of Hybrid-type radiation detector using $HgI_2$ (혼합형 구조를 적용한 $HgI_2$ 기반의 방사선 센서 제작 및 특성)

  • Jang, K.Y.;Kang, H.G.;Lee, G.H.;Kim, S.Y.;Park, J.K.;Choi, H.K.;Nam, S.H.;Lim, J.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.460-463
    • /
    • 2004
  • 본 논문은 고에너지 방사선 검출을 위한 흔합형 구조의 방사선 센서를 제작, 반응 특성을 평가하였다. 먼저, 스크린 인쇄법을 이용하여 형광체 필름을 제작하였으며, 발광스펙트럼(PL, Photoluminescence) 및 잔광 시간(decay time) 측정을 통하여 형광체의 발광 특성을 조사하였다. 제작된 혼합구조의 방사선 센서는 $2{\mu}m$ 두께의 $HgI_2$$150{\mu}m$ 두께의 형광체 필름으로 제작되었으며, 면적은 $2\;cm\;{\times}\;2\;cm$이다. 방사선에 대한 전기적 검출 신호의 특성을 조사하기 위해 인가전압에 따른 암전류 및 방사선민감도, 선량에 따른 검출신호를 측정하였다. 측정결과, 제작된 $HgI_2$ 필름은 방사선에 의해 형광체에서 방출된 가시광 파장을 잘 흡수하였으며, 진단영역의 저에너지 방사선에 의해 직접 전기적 신호를 발생시켜 높은 방사선 민감도를 보였다. 뿐만 아니라, 인가전압에 대해 $10\;pA/mm^2$이하의 낮은 암전류를 가졌으며, 넓은 조사선량에서 우수한 선형성을 보였다.

  • PDF

Changes according to the geometry of the shield using MCNP code system (MCNP코드 시스템을 이용한 차폐물 geometry에 따른 결과 변화에 대한 연구)

  • Kang, Ki-byung;Lee, Nam-ho;Hwang, Young-kwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.1031-1033
    • /
    • 2013
  • Radiation protection, as well as finding the location of the radiation source, such as the Fukushima radiation leak accident, it is important for the early and safe disposal of nuclear accident. The three-dimensional position of the radiation source detection distance of the radiation source can provide additional information to the existing radiation detectors radiation of a two-dimensional position detection function and then it can play a decisive role in the radiation contaminant removal and decontamination work. In this research, three-dimensional semiconductor sensor based on dual radiation detectors radiation source device visible part of the research and development of efficient radiation sensor unit on the design of the shielding structure.The lightweight, high-efficiency radiation source locator implementation was attempted for the structure and thickness of the shielding and collimator to perform the simulation of the radiation shielding for the various parameters of the shape model through design the optimal structure of the MCNP-based heavy-duty tungsten shielding, lead shielding The results of this study, is a compact, lightweight three-dimensional radiation source detection and future of silicon - based sensors will be used in the study.

  • PDF

A Study on the Fabrication of CsI(T1) Radiation Sensor and its Spectroscopic Characteristics (CsI(T1) 방사선센서의 제작 및 분광특성 연구)

  • 권수일;신동호
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.44-50
    • /
    • 2002
  • CsI(T1) single crystal was grown in a Bridgman growing apparatus, which has the diameter of 11 mm and the mole ratio of 0.001 mol%. Radiation sensors were made with CsITl)crystal and two photodiodes, and measured spectroscopic characteristics and linearity for gamma-ray and X-ray. The energy resolution of CsI(T1) radiation sensor has been measured with $^{22}$ Na, $^{137}$ Cs and $^{60}$ Co gamma standard sources. Also output linearity of CsITl) sensor was measured for diagnostic radiation region. The energy resolutions of CsI(T1) radiation sensor for 0.511MeV gamma-ray from Na-22 source, 0.662MeV from Cs-137 source, and 1.17MeV and 1.332MeV from Co-60 source were 13.2%, 8.3%, 6.7%, and 5.1% respectively. Also the output linearity up to 80mAs current for 60kVp, 80kvp, 100kVp, 120kVp tube voltages has been studied.

  • PDF

Radiation Effects on Fiber Bragg Gratings Written by Femtosecond Laser (펨토초 레이저로 제작된 광섬유 브래그 격자 센서의 방사선 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu;Im, Don-Sun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.961-963
    • /
    • 2015
  • In this study, we studied the effect of $Co^{60}$ gamma-radiation on the fiber Bragg gratings written by femtosecond UV laser in single mode optical fibers. The fiber Bragg gratings were exposed to gamma-radiation up to a dose of about 31.6 kGy at the dose rate of 106 Gy/min. According to the experimental data and analysis results, we confirmed Bragg gratings written by femtosecond laser have the excellent radiation-hardened characteristics for high radiation environments.

  • PDF

Gamma-radiation Effects on Fiber Bragg Gratings Written in Photo-sensitive and Commercial Single-mode Optical Fibers (광민감 광섬유와 일반 단일모드 광섬유로 제작한 브래그 격자 센서의 감마방사선 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu;Im, Don-Sun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.701-704
    • /
    • 2014
  • In this study, we studied the effect of $Co^{60}$ gamma-radiation on the FBGs written in photo-sensitive and commercial Ge-doped single-mode optical fibers. The FBGs were exposed to gamma-radiation up to a dose of 17.8 kGy at the dose rate of 300 Gy/min. According to the experimental data and analysis results, the lowest Bragg wavelength shift (18 pm) was obtained by a grating written in photosensitive fiber without $H_2$-loading.

  • PDF