• 제목/요약/키워드: 방사선센서

검색결과 232건 처리시간 0.023초

$BrO_2/a-Se$ 구조의 방사선 변환센서에서 a-Se에 첨가된 조성비 변화에 따른 I-V 특성 비교 (Comparison of the I-V Characteristic as Various Composition ratio of Iodine in a-Se of $BrO_2/a-Se$ based Radiation Conversion Sensor)

  • 최장용;박지군;공현기;안상호;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.440-443
    • /
    • 2002
  • Present1y the X-Ray diagnosis system is a real condition that is changing by digital ways in it's existent analog ways. This digital radiation detector is divided by the direct method and the indirect method. The indirect method of applied voltage has special qualities that the resolution is low than direct method by diffusion effect that happens. The conversion process ( radiation${\rightarrow}$visible ray${\rightarrow}$electrical signal of two times, has shortcomings that the energy conversion efficiency of electrical signal is low. The direct method has shortcomings that need strong electric fie1d to detect electrical signal efficiently. This research achieved to develop digital detector of the Hybrid method that have form that mixes two ways to supplement shortcoming of direct. indirect method. A studied electrical characteristic by Iodine's Mixture ratio change is added to selenium in the detector which has a multi-layer structure (Oxybromide + a-Se). There are 8 kinds of Manufactured compositions to amorphous selenium Iodine each 30ppm, 100ppm, 200 ppm, 300ppm, 400ppm, 500ppm, 600ppm, 700ppm by a doped photoconductor through a vacuum thermal evaporation method. The phosphor layer is consisted of Oxybromide ($BrO_2$) which uses optical adhesives multi-layer structure. The manufactured compositions calculates and compares Net Charge and signal to noise ratio measuring Photocurrent about Darkcurrent and X-ray. When doped Iodine Mixture ratio is 500ppm to the multi-layer structure (Oxybromide + a-Se), applied voltage of $3V/{\mu}m$, leakage current of compositions $2.61nA/cm^2$ and net charge value by 764pC/$cm^2$/mR then the best result appeared.

  • PDF

$BaF_2$ 검출기의 시간과 에너지 특성연구 (A Study on the Energy and Time Characteristics of $BaF_2$ Scintillation Detector)

  • 주관식;박일진;김종호;남기용;백승화
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권3호
    • /
    • pp.267-272
    • /
    • 1997
  • 3.6cm${\times}$2.0cm (지름 ${\times}$ 두께) 크기의 $BaF^2$ 섬광체로 검출기를 제작하여 감마 카메라등 의료용 진단장치에서 센서로 사용되고 있는 NaI(씨)검출기와 방사선 검출특성을 비교하여 보았다. 특정에 사용된 선원은 $^{22}Na,\;^{54}Mn,\;^{57}Co,\;^{137}Cs$${\gamma}$선 방출선원으로 검출기와 선원간의 거리를 7cm로 유지하였다. 시간특성을 분석하기 위하여 511keV의 양전자 방출선원을 사용하여 NaI(Tl)(1" ${\times}$ 1"), NaI(Tl)(3" ${\times}$ 3")순으로 $BaF^2$가 가장 빠르게 나타났으며, $BaF^2$ 검출기의 효율은 500keV에서 가장 높게 측정되었다.

  • PDF