• Title/Summary/Keyword: 방사선보건연구센터

Search Result 29, Processing Time 0.021 seconds

An Analysis of Temperature Change and TI MI using Tissue Mimicking Phantom in Ultrasonic Examination (초음파검사에서 인체모의 매질팬텀을 이용한 온도 변화와 TI MI 분석)

  • Cheol-Min, Jeon;Jae-Bok, Han;Jong-Gil ,Kwak;Jong-Nam, Song
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.751-759
    • /
    • 2022
  • Currently, ultrasound examination for diagnostic ultrasound and health examination purposes is widely used, and it is showing an increasing trend due to the application of health insurance. However, the risk of ultrasound has not been clearly identified so far, and in this study, surface and deep temperature changes according to frequency and mode were measured by using a tissue mimicking phantom and TI and MI values were compared. A simulated phantom was manufactured by adding a small amount of kappa-caraginan powder with acoustic characteristics similar to that of the human body and potassium chloride for solidification, and the change of surface and depth temperature was measured using a surface thermometer and a probe thermometer. As a result, the convex probe using low frequency showed a higher temperature increase than the linear probe using high frequency, so there was a significant difference, and the temperature increase was the highest on the surface, and the depth of 1cm showed a temporary temperature increase, but there was no significant temperature change. There was no change in the deep temperature of 5 cm to 15 cm, and the TI and MI values did not change during the test time. Since only the surface temperature rose during the 15-minute test and there was no temperature change in the core, so it is not expected to show a temperature change that is harmful to the human body. However, it is thought that prolonged examination of one area may cause temperature rise, so it should be avoided.

Comparing Physiological Changes in Breathing Conditions during Cognitive Tasks (인지부하 환경에서 호흡방식이 생체신호의 변화에 미치는 영향)

  • Jung, Ju-Yeon;Lee, Yeong-Bae;Park, Hyeon-Mi;Kang, Chang-Ki
    • Science of Emotion and Sensibility
    • /
    • v.25 no.2
    • /
    • pp.79-86
    • /
    • 2022
  • With external air pollution forcing many people indoors, new methods of facilitating healthier indoor life are necessary. This study, therefore, investigates the effects of indoor oxygen concentration and respiration methods on biosignals and cognitive ability. The study included twenty healthy subjects who inhaled air through a mask from a gas delivery system. All subjects were asked to perform three types of breathing (nasal, oral, and oral breathing with high oxygenation) and respond to cognitive stimuli (rest close eye, rest open eye, 1-back and 2-back working memory tasks). The changes in cognitive load according to respiration were analyzed by measuring response time, accuracy, and biosignals to stimuli. The result showed that, in all three respirations, heart rate significantly increased with the increase in cognitive load. Also, in oral respiration, the airway respiration rate significantly increased according to the increase in cognitive load. The change appeared to compensate for insufficient oxygen supply in oral respiration during cognitive activity. Conversely, there was no significant change in airway respiration rate during oral respiration with a high concentration oxygen supply as in nasal respiration. This result suggests that a high concentration oxygen supply might play a role in compensating for insufficient oxygen concentration or inefficient oxygen inhalation, such as oral respiration. Based on the results of this study, a follow-up study is necessary to determine the impact of changes in the autonomic nervous system, such as stress and emotions, to find out more precise and comprehensive effects of oxygen concentration and breathing type.

Relationship between Carotid Intima Media Thickness and Appendicular Skeletal Muscle Index according to Gender (성별에 따른 경동맥 내중막두께와 사지근육량지수와의 관련성)

  • Yang, Sung-Hee;Lee, Hee-Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.309-317
    • /
    • 2022
  • It is reported that social distancing caused by the corona pandemic has resulted in a decrease in physical activity, and a decrease in muscle mass due to this increases the risk of vascular disease. Therefore, in this study, the risk of carotid intima media thickness was evaluated by measuring the thickness of CIMT, and the differences in variables according to gender were analyzed. From January 2022 to May 2022, a total of 220 people (121 males, 99 females) who performed blood tests, carotid ultrasound, and body composition analysis among those who visited the health check-up center of Busan H Hospital were included in this study. Significant differences in risk factors according to gender were analyzed using the chi-square test. The cut-off values of variables that can predict the risk of carotid intima media thickness were calculated, and the accuracy was evaluated by calculating the area under the curve, sensitivity, and specificity. As a result of the difference analysis, the higher the total cholesterol in men and the appendicular skeletal muscle index in women, the higher the risk of carotid intima media thickness. The cut-off value for predicting the risk of carotid intima media thickness was calculated to be greater than 199 mg/dL of total cholesterol in the male group and less than 5.9 kg/m2 of the appendicular skeletal muscle index in the female group. As a result of this study, the higher the total cholesterol in men and the lower the appendicular skeletal muscle index in women, the higher the risk of increased CIMT. Therefore, in women, the appendicular skeletal muscle index is expected to serve as an indicator to predict and prevent vascular changes at an early stage.

Comparison of the Survey of Teaching Demand for Distance Education Support for the 2021 and 2022 Academic Years : For D Community Colleges in Daegu (2021학년도와 2022학년도 원격교육지원에 대한 교수 수요도 조사 비교: 대구지역 D전문대학을 대상으로)

  • Park, Jeong-Kyu
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.491-497
    • /
    • 2022
  • In this study, we tried to secure basic data to create an environment necessary for distance learning through a survey on professor demand. Among the 184 full-time faculty members of the university, 73 (39.89%) respondents in 2021 and 87 (47.28%) in 2022 were included. As a result of the research on professor demand, in the 2021 school year, 27 people (37%) were classified as LMS improvement items when checking attendance, 38 people (23.3%) were pin-mics as content development support items, and 26 people (35.6%), 33 people (45.2%) of GOM Mix and 25 people (34.2%) of the distance education support center wanted to learn video editing program as the item of video editing program they are currently using. In the 2022 school year, 27 people (31.03%) said mobile upgrade as an LMS improvement item, 52 people (59.8%) of pin-microphone as a content development support item, 33 people (37.9%), but currently using the content creation intention using a studio. As for the video editing program they are working on, 47 people (54%) of GOM Mix Pro and 23 people (26.4%) of the distance education support center want to learn content creation method. In addition, the intention to produce content using the studio for the 2021 and 2022 academic year and the desired educational topic of the distance education support center in the future appeared insignificant (p > 0.05). In this distance education support center, we are working to solve the class of LMS attendance, upgrade mobile, and plan to distribute pin microphones. We are planning to increase the usability of the studio and provide training on how to use video editing programs and how to create video content. In order for a smooth class to take place in a university distance class, the university authorities should seek ways to support the instructor so that he/she does not have difficulties in performing his/her role as a teaching designer, such as setting learning goals, organizing and organizing content, motivating learning, and establishing effective class participation plans. there is a need

Analysis of the Correlation Between Ultrasonography Diagnosis Fatty Liver Grade and Hyperlipidemia and Obesity Indicators by Age Groups (연령대별 초음파 진단 지방간 등급과 고지혈증 및 비만 지표 간의 상관관계 분석)

  • Hyeon, Sang-Yeon;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.863-870
    • /
    • 2020
  • The purpose of this study was to analyze the correlation between the grade of fatty liver diagnosed by ultrasonography and hyperlipidemia and obesity indicators by age groups. A total of 1,470 patients of various sex and age groups were examined by abdominal ultrasonography at the H Center in Chungbuk. The patients were classified as normal and fatty liver by age groups (below twenty, the thirties, forty, fifties, and over sixties). The grade of fatty liver was classified in detail as Grade 1 (mild fatty liver), Grade 2 (moderate fatty liver), Grade 3 (severe fatty liver). We selected indicators of hyperlipidemia as total cholesterol, triglyceride, low-density lipoprotein cholesterol, and high-density lipoprotein cholesterol. The obesity indicators were height, weight, body mass index, and waist circumference. The demographical descriptive statistic analysis and frequency analysis by age groups were performed. The difference of average and correlation between hyperlipidemia and obesity indicators were analyzed. As a result, patients over 60 have fatty liver regardless of sex. there was a difference between triglyceride, high-density lipoprotein cholesterol, weight, body mass index, and waistline for all age groups. The degree of fatty liver was highly correlated with waist size and body mass index for all age groups.

Antimicrobial Photodynamic Therapy on Pseudomonas aeruginosa Using a Diode Laser and PhotoMed, Methyl Pheophorbide A, or Radachlorin® (다이오드 레이저와 PhotoMed, Methyl Pheophorbide A, Radachlorin®을 이용한 녹농균에 대한 항균 광역학 요법)

  • Young-Kyu SONG;Keun-Dol YOOK;Ji-Won KIM
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.56 no.1
    • /
    • pp.52-58
    • /
    • 2024
  • Photodynamic therapy (PDT) activates intracellular oxygen using a photosensitizer activated by light of a specific wavelength and is a potential means of treating wound infections caused by antibiotic-resistant bacteria. Pseudomonas aeruginosa (P. aeruginosa) is typically non-pathogenic in healthy individuals but can induce severe illnesses like sepsis in the immunocompromised. Antibiotics have been conventionally used to treat P. aeruginosa infections, but increasing antibiotic resistance caused by drug misuse poses a growing challenge to the management of these infections. This study aimed to investigate the ability of PDT using photosensitizers (PhotoMed, Methyl pheophorbide A, or Radachlorin®) and a diode laser to inhibit P. aeruginosa. Suspensions of P. aeruginosa and a photosensitizer were inoculated into Petri dishes and incubated for 30 minutes. Samples were then irradiated with the laser at 3 J/cm2, and after incubation, colony areas were measured. P. aeruginosa killing rates were 79.65% for PhotoMed, 47.36% for Methyl pheophorbide A, and 40.91% for Radachlorin®. This study shows that PDT using a diode laser and a photosensitizer constitutes an effective practical therapeutic approach for inhibiting P. aeruginosa.

The Evaluation of Dose Reduction and Quality of Images According to 80 kVp of Scan Mode Change in Pediatric Chest CT (소아 흉부 CT 검사에서 관전압 80 kVp 조건으로 스캔 모드별 방사선량 감소와 화질 평가)

  • Kim, Gu;Kim, Gyeong-Rip;Lee, Eun-Sook;Cho, Hee-Jung;Sung, Soon-Ki;Moon, Seul-ji-a;Kwak, Jong-Hyeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.284-292
    • /
    • 2019
  • To evaluate the usefulness of pediatric chest CT scans by comparing the dose, examination time, and image quality by applying Helical mode, High-pitch mode, and Volume Axial mode to minimize the radiation exposure and obtain high diagnostic value. Revolution (GE Healthcare, Wisconsin USA) was used to divide PBU-70 phantom into Helical mode, High-pitch mode, and Volume Axial mode. After acquiring images, ROI is set for each image, heart, bone, lung, and back-ground air, and the average value is obtained by measuring CT number (HU) and noise (SD). SNR and CNR were measured and compared with DLP values provided directly by the equipment. Determining statistical significance Statistical analysis was performed using ONE-WAY-ANAOVA using SPSS 21.0. In this experiment, it was possible to inspect at a short time without deterioration of image quality with the lowest dose when using volume axial mode. Although the detector coverage of 16 cm is limited to all pediatric chest CT scans, it is recommended to be actively used in pediatric patients, and further study is needed to apply other test sites in volume axial mode.

Correlation Analysis Between 3D Kidneys Measurements and Abdominal Obesity Level in Computed Tomography (전산화단층영상에서 콩팥 3차원 영상 계측치와 복부 비만도 간의 상관관계 분석)

  • Ji-Yeong Kim;Youl-Hun Seoung
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.315-325
    • /
    • 2023
  • The purpose of this study was to predict abdominal obesity with 3-Dimensional computed tomography (3D CT) measurements of kidneys by analyzing the correlation between kidney sizes and abdominal obesity level. The subjects were 178 healthy adults without underlying diseases who had a comprehensive health examination at the Health Medical Center of Jesus Hospital in Jeonju. Abdominal obesity was measured by CT cross-sectional image at the level of the umbilicus and divided into visceral fat area, subcutaneous fat area, visceral fat/total fat ratio. The average comparison of kidney sizes classified according to abdominal obesity were performed through one-way analysis of variance (ANOVA) and Scheffe test. Pearson correlation analysis was performed to correlate all measurement values. The results of kidney size ANOVA analysis according to abdominal obesity were as follows. The means of kidney measurements according to visceral fat classification were significantly different in all kidney measurements (p<0.05). And in case of subcutaneous fat classification, the means of kidney measurements by 3D CT of the severe obesity group were significantly different in the right kidney width (p<0.05). In case of visceral fat area/total fat area ratio, the means of kidney measurements by 3D CT of the severe obesity group were significantly different in both kidneys width (p<0.05). Pearson correlation between kidneys measurements and CT abdominal obesity showed that visceral fat area had the highest correlation with the left kidney width measured by 3D CT (r=0.467) and subcutaneous fat area had correlation with the right kidney width measured by 3D CT (r=0.249). The visceral fat area/total fat area ratio had correlation with the left kidney width measured by 3D CT (r=0.291).

Factors associated with Electronic Cigarettes Use in Korean Adults (한국 성인의 전자담배 사용 관련요인)

  • Park, Eui-Cheol;Bae, Seok-Hwan;Lee, Moo-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.47-55
    • /
    • 2019
  • This study was conducted to investigate the factors associated with electronic cigarette use by Korean adults. To accomplish this, data collected from 228,477 individuals during a community health survey conducted by the Korean Centers for Disease Control and Prevention in 2015 were analyzed by descriptive analysis, the Chi-squared test, and logistic regression analysis. The lifetime prevalence of electronic cigarette smoking was 11.1% for men and 0.8% for women. The current prevalence for electronic cigarettes smoking was 24.2% for men and 26.1% for women among lifetime users of electronic cigarettes. The lifetime experience rate of electronic cigarette smoking was significantly associated with age, educational attainment, occupation, income status and current smoking status, respectively. The current universal smoking e-cigarette is significantly related to the current smoking status, which shows a significantly higher number of current smokers than groups that have smoked in the past. The preference for electronic cigarette smoking was high. E-cigarettes were perceived by those who aimed to quit smoking as having a smoking cessation effect compared to regular cigarettes while also providing the pleasure of smoking and addressing the addiction. Therefore, e-cigarettes were highly favored because they were reflected as a solution to the dilemma of smoking. In 2014, electronic cigarette imports tripled from the previous year, and interest in electronic cigarettes is increasing worldwide. Accordingly, measures related to the prevention and discontinuation of e-cigarettes should be considered. Strengthening anti-smoking education and active promotion of anti-smoking risks is needed to improve smokers' wrong perception of smoking-related health. The WHO also reports that there is a lack of grounds to ensure or acknowledge that e-cigarettes are effective. Accordingly, it is important to identify environmental factors influencing the use of electronic cigarettes and explore the relationship between electronic cigarette recognition and use.