• Title/Summary/Keyword: 방사선량측정

Search Result 533, Processing Time 0.032 seconds

The Change of Total Scan Time in Accordance with the Time of the Decision of Scan Time (스캔 시간의 결정시기에 따른 총 스캔 시간 변화에 관한 연구)

  • Lee, Jong-Hun;Ryu, Jae-Kwang;Chung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.81-85
    • /
    • 2009
  • Purpose: The examination of nuclear medicine observes the change in accordance with the time elapsed in the same region purposed and there are many examinations to acquire the image during the same term. At this time, the same parameter should be applied. The hepatobiliary scan, lung scan etc, are the acquired examination in the divided time with a regular term. Pre-set time that is applied in continued next image is set in order to acquire the fixed counts. The same scan time should be applied for each image. This study will look for the rational plan and analyze the change of scan time in accordance with the time of the decision of scan time at examination that pre-set time is applied. Methods: The hapatobiliary scan that use the radio pharmaceutical $^{99m}Tc$-mebrofenin is choosed as compensation from Jan. 2009 to Mar. 2009 in the department of nuclear medicine in ASAN MEDICAL CENTER. Scan is started after 5 minutes from when 222 MBq (6 mCi) is injected to patient. We let patient stand up between both detectors, and possibly close to the front of detector. When scan time reach 10%, 25%, 50%, 75% of total scan time, we measured the expected total scan time. After finishing all of scan, we compared the total scan time and the expected total scan time, while image is acquiring. and we observed the change of scan time in accordance with radio activity by using phantom. Results: After starting scan, a difference of when scan time reach 10%, 25%, 50%, 75% of total scan time is that the biggest difference is 5 seconds on 10%. There statistically is difference between 25% (t:2.88, p<0.01) and 50% (t:2.05, p<0.01). Conclusions: When the same the scan time is applied in the examination that acquire the many frame, concluding the same scan time has a important effect on a quantitative analysis. Although method that decide the scan time after finish all of the examinations, there is a few problem to apply practical affairs. This may cause an inaccurate result on the examination that need a quantitative analysis. We think that operator should try to improve it. At least, after reach 50% of total scan time, deciding the total scan time mean that you can minimize error of a quantitative analysis caused by unmatched scan time from a gap of image.

  • PDF

Radiation Effect on NO, NOS and TGF-$\beta$ Expressions In Rat Lung (쥐의 폐에서 방사선이 Nitric Oxide (NO), Nitric Oxide Synthase (NO) 및 TGF- $\beta$의 발현에 미치는 영향)

  • Oh Young-Taek;Park Kwang-Joo;Kil Hoon-Jong;Ha Mahn Joon;Chun Mison;Kang Seung-Hee;Park Seong-Eun;Chang Sei-Kyung
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.321-328
    • /
    • 2000
  • Purpose :NOS2 induce NO Production and NO activate TGF-${\beta}$. The TGF-${\beta}$ is a inhibitor of NOS2. If this negative feedback mechanism operating in radiation pneumonitis model, NOS2 inhibitor may play a role in TGF-${\beta}$ suppression. We planned this study to evaluate the expression patterns of NO, NOS2 and TGF-${\beta}$ in vivo radiation pneumonitis model. Materials and Methods : Sixty sprague-Dawley rat were irradiated 5 Gy or 20 Gy. They were sacrificed 3, 7, 14, 28 and 56 days after irradiation. During sacrifice, we peformed broncho-alveolar lavage (BAL). The BAL fluids were centrifuged and supernatents were used for measure NO and TGF-${\beta}$, and the cells were used for RT-PCR. Results : After 5 Gy of radiation, NO in BAL fluid increased at 28 days in both lung and TGF-${\beta}$ in left lung at 56 days. NO increased in BAL fluid at 28 days in both lung after irradiation and TGF-${\beta}$ in right lung at 28-56 days after 20 Gy of radiation. After 5 Gy of radiation, NOS2 expression was increased in right lung at 14 days, in both lung at 28 days and in left lung at 56 days. TGF-${\beta}$ expression was reduced in both lung at 28 days and increased in left lung at 56 days. Conclusions :The Proposed feedback mechanism of NO, NOS2 and TGF-${\beta}$ was operated in vivo radiation pneumonitis model. At 56 days, however, NOS2 and TGF-${\beta}$ expressed concurrently in left lung after 5 Gy and in both lung after 20 Gy of radiation.

  • PDF

Effects for Growth and Chlorophyll in Old-barley and New-barley Seed exposed by X-ray (X-선이 묵은보리 씨앗과 햇보리 씨앗의 생장과 클로로필 농도에 미치는 영향)

  • Sang-Bok, Jeong;Sun-Cheol, Jeong;Mo-Kwon, Lee;Yun-Ho, Choi;Kang-Un, Byun;Su-Ah, Yu;Sang-Eun, Han;Jun-Beom, Heo;Wan-Sik, Shin;Won-Jeong, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.149-156
    • /
    • 2023
  • The purpose of this study is to compare of growth and chlorophyl between old-barley seed (OBS, 2019) and New-barley seed (NBS, 2020) exposed by X-ray. After germination the OBS and NBS, experimental group was exposed by 30 Gy X-ray using linear accelerator (Clinac IS, VERIAN, USA), by 6 MV X-ray, SSD 100 cm, 18 × 10 cm2, 600 MU/min. Length was measured every day until 9th day, and chlorophyl was analyzed using spectrophotometer(uv-1800, shimadzu, japan) after measuring weight in 9th day. Data analysis was performed the Independent T-test using SPSS ver 26.0(Chicago, IL, USA). NBS grow more faster than OBS in control group, but OBS grow more faster than NBS in experimental group. Length of control group was longer significantly every day than that of experimental group in OBS. NBS weighted more than OBS in control group, but OBS weighted more than NBS in experimental group. In comparing chlorophyl density, NBS high more than OBS in control group as well as experimental group. Growth and weight of OBS was effected more those than NBS by X-ray, but NBS in chlorophyl by X-ray. It is expected to be used as basic data for future X-ray research in barley seed.

Histological Changes in the Normal Tissues of Rat after Local Application of the Holmium-166-Chitosan Complex attached to Biodegradable Solid Material (생분해성 고형물에 흡착시켜 실험동물에 국소 투여한 홀미움- 166-키토산 복합체의 투여량, 기간 및 부위에 따른 조직의 괴사 정도와 양상)

  • Lee, Jong-Seok;Jeon, Dae-Geun;Cho, Wan-Hyung;Lee, Soo-Yong;Oh, Jung-Moon;Kim, Jin-Wook
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.2
    • /
    • pp.190-199
    • /
    • 2003
  • Purpose: The aim of this study was to find out a clinically appliable method to insert a biodegradable solid material containing holmium-166-chitosan complex into the surgical field, and to evaluate the histological changes in the normal tissues after ${\beta}$ -ray irradiation from holmium-166 according to the dose, period and type of tissues. Materials and Methods: 3.0 mCi, 50 ${\mu}l$ of the liquid state $^{166}$Ho-chitosan complex was attached to the absorbable gelatin sponge. The radiation activity measured by dose caliberator was 1.5 mCi. These $^{166}$Ho-chitosan complex containing absorbable gelatin sponges were inserted into the thigh muscles and over the femur bones of the Wistar rats. The cases were evaluated at 2 weeks after insertion, and 4, 6 weeks with respect to the histological changes of the soft tissues and bone, the depth of the tissue necrosis, and the changes of the $^{166}$Ho-chitosan complex containing absorbable gelatin sponges. Results: At 2 weeks, the muscles showed coagulation necrosis, degenerating myocytes, regenerating myocytes, intermuscular edema, and inflammatory cells. The necrosis depth was 3.3 mm. In the bones, there was no osteocyte in the lacuna of cortex (empty lacuna), marrow fibrosis, inflammation. The necrosis depth was 2.9 mm. At 4 weeks, in the muscle, calcification and increased fibrosis with necrosis depth by 3.3 mm were the additional findings. In the bone, marrow fibrosis with necrosis depth by 3.3 mm were detected. At 6 weeks, soft tissue shrinkage, increased fibrosis and granulation tissue formation, and nearly resolving inflammatory reaction were the findings. Conclusion: The local application of the $^{166}$Ho-chitosan complex attached to biodegradable gelatin material with surgery in the laboratory animals resulted in no mortality and morbidity, and satisfactory tissue necrosis. Holmium-166 can be applied to the treatment of the malignant tumor patients.

  • PDF

Implant Isolation Characteristics for 1.25 Gbps Monolithic Integrated Bi-Directional Optoelectronic SoC (1.25 Gbps 단일집적 양방향 광전 SoC를 위한 임플란트 절연 특성 분석)

  • Kim, Sung-Il;Kang, Kwang-Yong;Lee, Hai-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.8
    • /
    • pp.52-59
    • /
    • 2007
  • In this paper, we analyzed and measured implant isolation characteristics for a 1.25 Gbps monolithic integrated hi-directional (M-BiDi) optoelectronic system-on-a-chip, which is a key component to constitute gigabit passive optical networks (PONs) for a fiber-to-the-home (FTTH). Also, we derived an equivalent circuit of the implant structure under various DC bias conditions. The 1.25 Gbps M-BiDi transmit-receive SoC consists of a laser diode with a monitor photodiode as a transmitter and a digital photodiode as a digital data receiver on the same InP wafer According to IEEE 802.3ah and ITU-T G.983.3 standards, a receiver sensitivity of the digital receiver has to satisfy under -24 dBm @ BER=10-12. Therefore, the electrical crosstalk levels have to maintain less than -86 dB from DC to 3 GHz. From analysed and measured results of the implant structure, the M-BiDi SoC with the implant area of 20 mm width and more than 200 mm distance between the laser diode and monitor photodiode, and between the monitor photodiode and digital photodiode, satisfies the electrical crosstalk level. These implant characteristics can be used for the design and fabrication of an optoelectronic SoC design, and expended to a mixed-mode SoC field.

Serial Determinations of Serum Squamous Cell Carcinoma Antigen (SCC) during Radiotherapy for Uterine Cervix Cancer (자궁경부암에서 방사선치료 중 혈중 Squamous Cell Carcinoma Antigen 값의 변화)

  • Yun, Hyong-Geun;Park, Seok-Kun
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.136-141
    • /
    • 2001
  • Purpose : To evaluate the significance of serum SCC for the monitoring of treatment response and the early detection of distant metastasis during radiotherapy (RT). Materials and Methods : In 13 patients with histologically proven primary squamous cell carcinoma of uterine cervix, serum SCC values were checked in pre-RT point, weekly during RT, and in post-RT point. Results : In 4 of 13 cases, metastasis appeared at the end of external RT, so that intracavitary radiation couldn't be peformed.01 these 4 cases,3 with elevated pre-RT SCC level, who resulted in lung metastasis on chest PA at the end of external RT showed decreased post-RT SCC value despite of metastasis. Of all 10 cases with elevated pre-RT SCC value (including 3 with metastasis at the end of external RT), SCC value was higher than pre-RT value in 7 at 9 Gy and the difference was statistically significant. At 18 Gy, SCC was higher in 4 and lower in 6 than pre-RT value. After 18 Gy, SCC value decreased continuously to the end of RT in all 10 cases. Conclusion : During RT, SCC value increased initially at 9 Gy. To 18 Gy, SCC value decreased to the nearly same with pre-RT value. After 18 Gy, to the end of RT, SCC value decreased continuously and normalized in completely responded cases. In cases with appearance of lung metastasis, SCC value also decreased with the disappearance of main mass of uterine cervix despite metastasis.

  • PDF

Minimization of Small Bowel Volume within Treatment Fields Using Customized Small Bowel Displacement System(SBDS) (골반부 방사선 조사야 내의 소장 용적을 줄이기 위한 Small Bowel Displacement System(SBDS)의 사용)

  • Lim Do Hoon;Huh Seung Jae;Ahn Yong Chan;Kim Dae Yong;Wu Hong Gyun;Kim Moon Kyung;Choi Dong Rak;Shin Kyung Hwan
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.263-268
    • /
    • 1997
  • Purpose : Authors designed a customized Small Bowel Displacement System (SBDS) to displace the small bowel from the Pelvic radiation fields and minimize treatment-related bowel morbidities. Materials and Methods : From August 1995 to Mar 1996. 55 consecutive patients who received pelvic radiation therapy with the SBDS were included in this study. The SBDS consists of a customized styrofoam compression device which can displace the small bowel from the radiation fields and an individualized immobilization abdominal board for easy daily setup in prone position After opacifying the small bowel with Barium3, the patients were laid Prone and posterior-anterior (PA) and lateral (LAT) simulation films were taken with and without the SBDS. The areas of the small bowel included in the radiation fields with and without the SBDS were compared. Results : Using the SBDS, the mean small bowel area was reduced by $59\%;on\;PA\;and\;51\%$ on LAT films (P=0.0001). In six Patients (6/55. $11\%$), it was Possible that no small bowel was included within the treatment fields. The mean upward displacement of the most caudal small bowel was 4.8 cm using the SBDS. Only $15\%$ (8/55) of patients treated with the SBDS manifested diarrhea requiring medication. Conclusion : The SBDS is a novel method that can be used to displace the small bowel away from the treatment portal effectively and reduce the radiation therapy morbidities. Compliance with setup is excellent when the SBDS is used.

  • PDF

Early Pulmonary Irradiation in Paraquat ($Gramoxone^{(R)}$) Poisoning (Paraquat 중독 환자에서 전폐 방사선치료의 효과)

  • Lee, Chang-Geol;Kim, Gwi-Eon;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.321-330
    • /
    • 1995
  • Purpose : To evaluate whether the early pulmonary irradiation can prevent or decrease the pulmonary damage and contribute to improve ultimate survival in paraquat lung. Materials and Methods : From Jun. 1987 to Aug. 1993, thirty patients with paraquat poisoning were evaluated. Fourteen of these patients were received pulmonary irradiation(RT). All of the patients were managed with aggressive supportive treatment such as gastric lavage, forced diuresis, antioxidant agents and antifibrosis agents. Ingested amounts of paraquat were estimated into three groups(A : minimal 50cc). Pulmonary irradiation was started within 24 hours after admission(from day 1 to day 11 after ingestion of paraquat). Both whole lungs were irradiated with AP/PA parallel opposing fields using Co-60 teletherapy machine. A total of 10Gy(2Gy/fr. x 5days) was delivered without correction of lung density. Results : In group A, all patients were alive regardless of pulmonary irradiation and in group C, all of the patients were died due to multi-organ failure, especially pulmonary fibrosis regardless of pulmonary irradiation. However, in group B, six of 7 patients($86{\%}$) with no RT were died due to respiratory failure, but 4 of 8 patients with RT were alive and 4 of 5 patients who were received pulmonary irradiation within 4 days after ingestion of paraquat were all alive though radiological pulmonary change. One patient who refused RT after 2Gy died due to pulmonary fibrosis. All 3 patients who were received pulmonary irradiation after 4 days after ingestion were died due to pulmonary fibrosis in spite of recovery from renal and hepatic toxicity Conclusion : It is difficult to find out the effect of pulmonary irradiation on the course of the paraquat lung because the precise plasma and urine paraquat concentration were not available between control and irradiation groups. But early pulmonary irradiation within 4 days after paraquat poisoning with aggresive supportive treatment appears to decrease Pulmonary toxicity and contribute survival in patients with mouthful ingestion of paraquat who are destined to have reversible renal and hepatic damage but irreversible pulmonary toxicity.

  • PDF

Consideration about LINAC movable range by H&N patient immobilization device manufacture (두경부환자 고정기구제작을 통한치료기 가동범위에 관한 고찰)

  • Jung DoHyung;Shim JinSeop;Youm DuSeok;Choi GyeSuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.63-67
    • /
    • 2004
  • Purpose : New therapy technique appeared in 3D-CRT or IMRT according to a radiation treatment developing and worked. Such treatment technique requires the radiation irradiation of many direction. It has many restriction at radiation irradiation of many direction to the linear acceleration deception of now actually. Consequently We make new fix device and measure consequently the improvement of the activate range. Method and Material : We upload the fix device on a linear accelerator Couch. We fixed Gantry at 45, 90, 135 and Couch is spin and measure the clearance of the equipment. Couch is fixed at 0 45 90 and measures the clearance of Gantry. We upload the Extended head holder(EHH) on a linear accelerator Couch. and We measure with the experiment of the front. Result : The action range did not have big difference to increase Gantry45. but The activate range of Couch increases the angle in Gantry 90 and Gantry 135 when it uses EHH. The activate range of Gantry increases the angle in Couch 45 when it uses EHH. We showed good activate situation all in Couch 0 and Couch 90. The utility of EHH could keep a behind radiation diminution. Conclusion : The radiation irradiation of many direction comes to be possible the utility of the fix instrument(EHH). The safety space between the patient and equipment or between equipment and equipment increased the utility of the fix device. Also, The manufacture is possible imports to rather cheap price. and We could bring the frugality of the treatment expendable supplies.

  • PDF

Elementary School in Gwangju Gwangsan Radon gas Density Measurement (광주광역시 광산구 소재 초등학교 라돈가스 농도 계측)

  • Ahn, Byungju;Oh, Jihoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.211-216
    • /
    • 2014
  • Radium is rock or soil of crust or uranium of building materials after radioactivity collapse process are created colorless and odorless inert gas that accrue well in sealed space like basement. It inflow to lung circulate respiratory organ and caused lung cancer because of deposition of lung or bronchial tubes. In this study, the air in the elementary school classroom nongdoeul tonkatsu place of measured values were compared using the calculated annual internal radiation exposure. La tonkatsu exposure measured in primary school classroom at least five schools when you close the windows in the average floor 0.56mSv 2 floors ground floor windows when opened 0.384mSv 048mSv 3 floors, 2 floor levels of the same three layers 0.31mSv 0.296mSv the human exposure to radon and radiation on the first floor of 3 floors above ground in a lot of exposure was moderate. When you close the window from the first floor up 0.384mSv 056mSv 3 floors with a minimum annual radiation exposure due to natural radiation in the 16 to 23.3 percent minimum 2.4mSv accounted for. When I opened the window to the maximum annual radiation exposure 2.4mSv 0.296mSv 0.31mSv least a minimum of 12.3 to 12.91% accounted for Results suggest that more than five chodeunghakgyoeun La tonkatsu domestic radon measurements conducted below regulatory requirements and internal exposure has also fall within the normal range. People The less the radiation exposure to the human body because it reduces the impact in the classroom in elementary school vent windows often reduced to the maximum radon concentration in the air, if called tonkatsu be able to reduce radiation exposure for the immune system is weak and elementary will be helpful to experiment more in the future for the school authorities called tonkatsu investigation is done to him if the action to establish a more secure school building facilities is thought would be helpful.