• Title/Summary/Keyword: 방사선노출

Search Result 457, Processing Time 0.026 seconds

Effect of immobilization of the recombinant human bone morphogenetic protein 2 (rhBMP-2) on anodized implants coated with heparin for improving alveolar ridge augmentation in beagle dogs: Radiographic observations (양극산화 임플란트 표면에 적용된 헤파린과 골형성단백질(rhBMP-2)이 치조골 증대에 미치는 효과: 방사선학적 평가)

  • Lee, So-Hyoun;Jo, Jae-Young;Yun, Mi-Jung;Jeon, Young-Chan;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.307-314
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate the effect of immobilization of the recombinant human bone morphogenetic protein 2 (rhBMP-2) on anodized titaum implants coated with heparin to enhance the vertical alveolar ridge augmentation in the supraalveolar peri-implant defect region. Materials and methods: 18 pure titanium implants (7.0 mm in length, 3.5 mm in diameter) were manufactured for this study. All implants were anodized and designed insertion reference line marked with laser at the apical 2.5 mm from the fixture platform. Implantation of 6 noncoated anodized implants (Control group), 6 anodized implants physically adsorbed with rhBMP-2 by dip and dry method (BMP group) and 6 anodized implants chemically immobilized 3,4-dihydroxyphenylalanine (DOPA)-heparin/ rhBMP-2 (Hep-BMP group) was performed in the both mandibular of three male adult beagle dogs using split-mouth design. Radiologic examinations were performed immediately after implant placement and 4 and 8 weeks after implant placement. The amount of mesio-distal bone augmentation was evaluated by measuring the vertical distance from the platform to the marginal bone. Statistical analysis was performed using one-way analysis of variance (SPSS version 18.0) and multiple comparison analysis of The Kruskal-Wallis test and the Mann-Whitney U test. Statistical significance was established at the 5% significant level. Results: At the 4 weeks vertical alveolar ridge augmentation of Control group, BMP group and Hep-BMP group is $0.09{\pm}0.22mm$, $1.02{\pm}0.72mm$, and $1.29{\pm}0.51mm$, At the 8 weeks $0.11{\pm}1.26mm$, $1.11{\pm}0.58mm$, $1.59{\pm}0.79mm$ according to radiographic observations. The two experimental groups showed a significantly increasing in vertical bone height compared with the control group (P<.05). However, there is no significant difference between the BMP group and Hep-BMP group (P>.05). Conclusion: The rhBMP-2 coated implants were enhanced the vertical bone growth in the supraalveolar peri-implant defect area. However, there is no significant difference between chemically and physically coating method.

Research of z-axis geometric dose efficiency in multi-detector computed tomography (MDCT 장치의 z-축 기하학적 선량효율에 관한 연구)

  • Kim, You-Hyun;Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.167-175
    • /
    • 2006
  • With the recent prevalence of helical CT and multi-slice CT, which deliver higher radiation dose than conventional CT due to overbeaming effect in X-ray exposure and interpolation technique in image reconstruction. Although multi-detector and helical CT scanner provide a variety of opportunities for patient dose reduction, the potential risk for high radiation levels in CT examination can't be overemphasized in spite of acquiring more diagnostic information. So much more concerns is necessary about dose characteristics of CT scanner, especially dose efficient design as well as dose modulation software, because dose efficiency built into the scanner's design is probably the most important aspect of successful low dose clinical performance. This study was conducted to evaluate z-axis geometric dose efficiency in single detector CT and each level multi-detector CT, as well as to compare z-axis dose efficiency with change of technical scan parameters such as focal spot size of tube, beam collimation, detector combination, scan mode, pitch size, slice width and interval. The results obtained were as follows ; 1. SDCT was most highest and 4 MDCT was most lowest in z-axis geometric dose efficiency among SDCT, 4, 8, 16, 64 slice MDCT made by GE manufacture. 2. Small focal spot was 0.67-13.62% higher than large focal spot in z-axis geometric dose efficiency at MDCT. 3. Large beam collimation was 3.13-51.52% higher than small beam collimation in z-axis geometric dose efficiency at MDCT. 4. Z-axis geometric dose efficiency was same at 4 slice MDCT in all condition and 8 slice MDCT of large beam collimation with change of detector combination, but was changed irregularly at 8 slice MDCT of small beam collimation and 16 slice MDCT in all condition with change of detector combination. 5. There was no significant difference for z-axis geometric dose efficiency between conventional scan and helical scan, and with change of pitch factor, as well as change of slice width or interval for image reconstruction. As a conclusion, for reduction of patient radiation dose delivered from CT examination we are particularly concerned with dose efficiency of equipment and have to select proper scanning parameters which increase z-axis geometric dose efficiency within the range of preserving optimum clinical information in MDCT examination.

  • PDF

Effects of Vitamin C on Residual Aflatoxin $B_1$ in Rat Sera Treated with Radiation and Aflatoxin $B_1$ (Vitamin C가 방사선과 Aflatoxin $B_1$을 투여한 흰쥐의 혈청 중 Aflatoxin $B_1$ 잔류량에 미치는 영향)

  • Chung, Do-Young;Kim, Han-Soo;Kang, Jin-Soon
    • Food Science and Preservation
    • /
    • v.18 no.3
    • /
    • pp.374-382
    • /
    • 2011
  • Aflatoxin ($AFB_1$) is a potent hepatotoxic and hepatocarcinogenic mycotoxin in humans. It is also well-known to be accumulated in animal tissues via various metabolic pathways. This study was conducted to determine the effects of vitamin C on the residual $AFB_1$ in rat sera that were treated with radiation and $AFB_1$. Six week-old male Sprague-Dawley rats were randomly divided into five groups: a control group, $AFB_1$-treated group, the group treated with $AFB_1$ and vitamin C, the group treated with X-ray and AFB1, and the group treated with X-ray and $AFB_1$ with vitamin C. On the first day of the experiment, only one dose of X-rays was exposed to the entire liver at 1,500 cGy. Next, vitamin C was injected at 10 mg/kg body weight via intraperitoneal injection, followed 1 hr later by the administration of 0.4 mg/kg of $AFB_1$ via intraperitoneal injection. These treatments were then administered every three days over a period of 15 days. On the 16th day of treatments, the animals were sacrificed. The contents of $AFB_1$ in rat sera were determined via indirect competitive ELISA and HPLC method. In the quantitative analysis of $AFB_1$ in rat sera via ELISA, $5.17{\pm}0.34$ ng/mL of $AFB_1$ was detected in the $AFB_1$-treated groups, but the amount more significantly decreased to $3.23{\pm}0.76$ ng/mL in the groups treated with $AFB_1$ and vitamin C (p<0.01) than in the $AFB_1$-treated groups. The $AFB_1$ contents of the rat sera of the groups treated with X-ray and $AFB_1$ did not significantly decreased with the administration of vitamin C. The $AFB_1$ content of the rat sera that was analyzed via HPLC showed a tendency similar to that of the content that was analyzed via ELISA. With regard to these data, vitamin C was very effective in reducing $AFB_1$ residue in rat sera.

Relation between Ablation Execution Time and Radiation Exposure Effect in the Treatment of Atrial-fibrillation using Cryo-balloon and 3D Radio-frequency Ablation (냉각 풍선 절제술과 3D 고주파 절제술을 이용한 심방세동 치료 시 절제술 시행 시간과 방사선 피폭 영향과의 연관성)

  • Seo, Young-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.427-434
    • /
    • 2022
  • Atrial fibrillation treatment includes 3D RFCA and Cryo-balloon ablation. Both procedures have in common that they enter after understanding the structure of the heart using angiography equipment. Therefore, there is a disadvantage that the effect of exposure according to the procedure time can be a threat to both the patient and the operator, so this study aims to confirm the relationship between the total ablation time and the effect of radiation exposure. We used follow-up data (retrospective) from 41 patients who underwent coronary angiography and arrhythmia at the same time from March 2019 to July 2022. The range for total ablation time was based on the recorded data from the start to the end of the total ablation. The end point of 3D RFCA was when the ablation was completed for 4 pulmonary veins, and in the case of Cryo-balloon ablation, the data that succeeded in electrical insulation were included. As a result of analyzing the total ablation time, the time taken for Cryo-balloon ablation was 1037.29±103.66 s, which was 2448.61 s faster than 3D RFCA using 3485.9±405.71 s, and was statistically significant. (p<0.05) As a result of analyzing the total fluoroscopy time, the exposure time for 3D RFCA was 2573.75±239.08 s, which was less by 1717.15 s than the exposure time for Cryo-balloon ablation, 4290.9±420.42 s, and was statistically significant. In the case of total area dose product, 3D RFCA was 59.04±13.1 uGy/m2, which was lower than Cryo-balloon ablation 980.6±658.07 uGy/m2 by 921.56 uGy/m2, which was statistically significant. As the insulation time of the Cryo-balloon ablation is shorter than that of the 3D RFCA, the method using the Cryo-balloon ablation is considered to be effective when the patient's condition is not good and a quick procedure is required. However, in patients with permanent Atrial fibrillation, there is a high probability of structural changes in the heart, so it is considered that 3D RFCA is better than Cryo-balloon ablation, which is difficult to manipulate.

The Comparative Analysis of Exposure Conditions between F/S and C/R System for an Ideal Image in Simple Abdomen (복부 단순촬영의 이상적 영상구현을 위한 F. S system과 C.R system의 촬영조건 비교분석)

  • Son, Sang-Hyuk;Song, Young-Geun;Kim, Je-Bong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.37-43
    • /
    • 2007
  • 1. Purpose : This study is to present effective exposure conditions to acquire the best image of simple abdomen in Film Screen (F.S) system and Computed Radiography (C.R) system. 2. Method : In the F.S system, while an exposure condition was fixed as 70kVp, images of a patients simple abdomen were taken under the different mAs exposure conditions. Among these images, the best one was chosen by radiologists and radiological technologists. In the C.R system, the best image of the same patient was acquired with the same method from the F.S system. Both characteristic curves from F.S system and C.R system were analyzed. 3. Results : In the F.S system, the best exposure condition of simple abdomen was 70kVp and 20mAs. In the CR system, with the fixed condition at 70kVp, the image densities of human organs, such as liver, kidney, spleen, psoas muscle, lumbar spine body and iliac crest, were almost same despite different environments (3.2mAs, 8mAs, 12mAs, 16mAs and 20mAs). However, when the exposure conditions were over or under (below) 12mAs, the images between the abdominal wall and the directly exposed part became blurred because the gap of density was decreased. In the C.R system, while the volume of mAs was decreased, an artifact of quantum mottle was increased. 4. Conclusion : This study shows that the exposure condition in the C.R system can be reduced 40% than in the F.S system. This paper concluded that when the exposure conditions are set in CR environment, after the analysis of equipment character, such as image processing system(EDR : Exposure Data Recognition processing), PACS and so on, the high quality of image with maximum information can be acquired with a minimum exposure dose.

  • PDF

Distribution and Management of Spatial Dose Rate in Neuro Angio Room (두개부 혈관조영실에서 공간산란선량의 분포와 관리)

  • Lee, Mi-Hwa;Jung, Hong-Ryang;Lim, Cheong-Hwan;Hong, Dong-Hee;Kim, Ki-Jeong;Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.12 no.4
    • /
    • pp.427-435
    • /
    • 2014
  • This study is performed in the intervention unit, during interventional procedures and in accordance with the direction and distance during the exposure indoor space is to measure the dose. I was classified at an angle of $45^{\circ}$ counterclockwise from the phantom. Seven(A, B, C, D, E, F, G) were classified as direction. Length was measured from the center of the phantom. Each direction 50cm, 100cm, 150cm, 200cm were classified. I was analyzed by measuring of frontal, lateral, Bi-plan fluoroscopic Spatial dose rate in all 28 points. Measured dose was the highest at 50cm and over 200cm, dose was rapidly decreasing as increased distance. Dose was different more than nine times depending on the distance and direction, Installation of shielding wall can reduce exposure about 84.52% to 93.54%.

The Effect of Extremely Low Frequency Electromagnetic Fields on the Chromosomal Instability in Bleomycin Treated Fibroblast Cells (Bleomycin이 처리된 사람 섬유아세포에서 극저주파 전자기장의 효과)

  • Cho, Yoon-Hee;Kim, Yang-Jee;Lee, Joong-Won;Kim, Gye-Eun;Chung, Hai-Won
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.4
    • /
    • pp.161-166
    • /
    • 2008
  • In order to determine the effect of extremely low frequency electromagnetic fields (ELF-EMF) on the frequency of micronuclei (MN), aneuploidy and chromosomal rearrangement induced by bleomycin (BLM) in human fibroblast cells, a 60 Hz ELF-EMF of 0.8 mT field strength was applied either alone or with ELM throughout the culture period and a micronucleus-centromere assay was performed. Our results indicate that the frequencies of MN, aneuploidy and chromosomal rearrangement induced by ELM increased in a dose-dependent manner. The exposure of cells to 0.8 mT ELF-EMF followed by ELM exposure for 3 hours led to significant increases in the frequencies of MN and aneuploidy compared to BLM treatment for 3 hours alone (p<0.05), but no significant difference was observed between field exposed and sham exposed control cells. The obtained results suggest that low density ELF-EMF could act as an enhancer of the initiation process of BLM rather than as an initiator of mutagenic effects in human fibroblast.

Research for The Environmental Optimization of Dose and Image quality in Digital Radiography (디지털 방사선촬영 환경에서 선량의 최적화 및 영상품질에 대한 연구)

  • Lee, Kwang Jae;Kim, MinGi;Lee, Jong Woong;Kim, Ho Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.203-209
    • /
    • 2013
  • Digital Radiography (DR) has improved a quality of resolution based on a wide dynamic range, high detective quantum efficiency (DQE), and modulation transfer function (MTF), compared with film/screen(F/s). Unlike expectation that a low level of radiation can be used in examination, high level of signal to noise ratio(SNR) due to over-exposure caused increase of exposed dose to patients. Also, the auto exposure control (AEC) using Kilovolage(kVp) in F/S can cause over-exposure. Hence, in this study, we proposed a proper method for using DR, in which effect of tubing Kilovolage on device's image, DR MTF measurement with changes of tubing current (mA), and the quantitative evaluation of skull phantom captured images' PSNR were evaluated. Changes of contrast with tubing Kilovolage can be improved by retouching, and MTF changes according to tubing current(1.41~1.39 lp/mm in 50% area, and 3.19~2.8 lp/mm in 10% area) does not influence on resolution of image. As a result, high tubing Kilovoltage, and tubing current will be suitable to use of DR.

ORTHODONTIC TRACTION OF HORIZONTALLY IMPACTED MAXILLARY INCISORS: CASE REPORTS (수평 매복된 상악 중절치의 교정적 견인: 증례 보고)

  • Kim, Mi-Ni;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taek;Kim, Chong-Chul;Hahn, Se-Hyun;Lee, Sang-Hun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.4
    • /
    • pp.757-765
    • /
    • 2008
  • Maxillary central incisor impactions occur infrequently. Their origins include various local causes, such as odontoma, supernumerary teeth, space loss, and disturbances in the eruption path, also trauma and apical follicular cysts. Impacted teeth can cause serious dental and aesthetic difficulties as well as psychological problems especially in anterior regions. Although the impaction of maxillary incisor occurs less frequently than that of the maxillary canine, it is of concern to parents during the early mixed dentition stage because of the uneruption of the tooth. Forced eruption of impacted teeth should be considered in young patients because this technique can lead to suitable results from a periodontal, occlusal, and esthetic perspective at an earlier stage better than with other treatment options. This report presents the surgical and orthodontic treatment of cases with horizontally impacted and dilacerated maxillary central incisors. For each patient, we used the closed eruption method, placed an attachment on the impacted tooth on surgery, and fully closed the flap. Traction was applied immediately. The impacted tooth erupts through the healed tissue in a manner resembling normal eruption.

  • PDF

ORTHODONTIC TRACTION OF IMPACTED POSTERIOR TEETH : CASE REPORTS (매복 구치부 치아의 교정적 이동 : 증례 보고)

  • Maeng, Yu-Jin;Oh, So-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.4
    • /
    • pp.613-618
    • /
    • 2009
  • Impacted molars are not usual with the prevalence rate of less than 1%, however problems such as infraocclusion, extrusion of the opposite tooth and lack of space are caused. If molars are impacted, radiographic check-up and observations are needed as they play an important role in skeletal development and mastication. Causes of impaction are underdevelopment of roots, supernumerary teeth, cysts, odontomas, ankylosis and etc. In our first case, we present impacted molar which was surgically exposed and orthodontically traded. As the developmental state of the root was less than half at first visit, we observed until the root was 2/3 in its length and traction was carried out. The second case is orthodontic traded molar with compleate enucleation of the existing cysts. When trading impacted molars, direct bonding of attachments to the tooth and light continuous forces are recommended so as to ankylosis, external absorption and periodontal attachment loss avoid. Fixed appliances tract the teeth on arch and obtain eruption spaces without patient's cooperation. We report surgically exposed and orthodontically traded molars which resulted in good occlusion and patients satisfaction.

  • PDF