• Title/Summary/Keyword: 방사선계측

Search Result 712, Processing Time 0.021 seconds

Evaluation for Performance of a Military Radiation Detecter PDR-1K : Focused on Dependence of Angular and Energy (군사용 방사선 계측기 PDR-1K 반응도 평가 : 방향 및 에너지 의존성을 중심으로)

  • Park, Wonseok;Choi, Junhyuk;Jung, Doyoung;Kim, Jango;Min, Byungin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.300-305
    • /
    • 2017
  • In this paper, we performed a evaluation for angular and energy dependence of military radiation detector PDR-1K. Its measuring range is divided into two section, low and high, and each range has a GM tube separately owing to broad scale. We observed a change in relative angular reactivity within 0.928 ~ 1.188 in low range and within 0.743 ~ 1.000 in high range from $-90^{\circ}$ to $+90^{\circ}$. The evaluation for energy dependence appeared a relative reactivity within 0.892 ~ 1.000 above 83 keV. This means PDR-1K isn't possible to use below 83 keV of radiation energy. It is possible to provide response information to user and to increase reliability of radiation measurement through this paper.

Radon Concentration at N-Kindergarten in G-City (G광역시 N유치원의 라돈 농도)

  • Park, Yun;Kim, Wonjun
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.421-424
    • /
    • 2015
  • In this study, To subject the constructed at N-kindergarten in G-city, the position is closed window and opened window was measured using a measuring instrument for radon. The measured results indicate that the measurement was carried out in concentrations of radon gas measured at N-kindergarten is low than United States in the radon concentration in air public 4pCi called radon gas baseline maximum allowable concentrations. As a result, radon exposure is not a problem, but when the accumulation radon gas in the lungs, get damaged same lung cancer. Be defensive of kindergarten windows open for ventilation and dust removal be possible to reduce the exposure.

Radiological Measurements of Lung Field Size in Normal Korean using Digital Chest Posteroanterior Radiography (디지털 흉부 후·전 방향 방사선영상을 이용한 정상 한국인 폐 크기의 영상의학적 계측)

  • Park, Yeo-Jin;Joo, Young-Cheol;Lee, Il-Soo
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • The purpose of this study is to provide baseline data on lung field size measured radiological method by chest PA image in normal Korean. The subject of this study is 496 normal persons who performed chest PA examination using x-ray digital radiography system. The measurement method is from the apex of right and left lung to the costophrenic angle of both lung, from the top of the image to the lowest costophrenic angle of both lung and transverse line of the largest lung area. As a result of this study, the following conclusions were obtained. A lung field size of male is larger than the female(p<0.05). The younger the age, the longer both lung length and total lung height statistically significant. As a increase height and length, A lung field size was increased(p<0.05). But, BMI is not associated with a lung field size. This study will be data of reference data when radiological technologists perform chest PA examination.

Cephalometric difference according to the differential treatment methods in Class III malocclusion; (제 III급 부정교합 환자들의 각 치료법에 따른 측모두부방사선사진 계측치의 비교)

  • Baik, Hyoung Seon
    • The korean journal of orthodontics
    • /
    • v.27 no.2
    • /
    • pp.197-208
    • /
    • 1997
  • Class III malocclusion patients can be approached with many different types of treatment methods, and thus, each patient's problems must be accurately evaluated to allow selection of the best possible treatment method. Cephalometric analysis is an essential part of diagnosis and treatment planning of orthodontic patients, and it would certainly be helpful if reliable cephalometric guidelines could be set. The author divided 482 Class III malocclusion patients(253 males and 229 females) into fourgroups according to different types of treatment methods they have received to correct imbalance between upper and lower jaws: 1) orthopedic appliance (face mask & RPE), 2) camouflage treatment with fixed appliance, 3) surgical-orthodontic treatment, 4) cross-bite correction with removable plates/ functional appliance. Cephalometric values at the time of first clinical examination were compare among the four groups. Cephalometric analysis indicates the following results: 1)the amounts of antero-posterior and vertical skeletal discrepancies and dental compensation were greatest in surgery group 2) SNB, Wits, distance from Nasion Perpendicular Plane to point a facial angle, facial convexity, and APDI were greater in orthopedic appliance group than fixed appliance(camouflage) group, but there was no statistical difference 3) removable plates/ functional appliance group showed least amounts of skeletal discrepancies and dental compensation with statistical significance.

  • PDF

Fabrication and Characterization of a One-dimensional Fiber-optic Dosimeter for Electron Beam Therapy Dosimetry (치료용 전자선 계측을 위한 1차원 광섬유 방사선량계의 제작 및 특성분석)

  • Jang, Kyoung-Won;Cho, Dong-Hyun;Shin, Sang-Hun;Yoo, Wook-Jae;Jun, Jae-Hun;Lee, Bong-Soo;Moon, Joo-Hyun;Park, Byung-Gi
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.285-290
    • /
    • 2008
  • In this study, we have fabricated a one-dimensional fiber-optic dosimeter for electron beam therapy dosimetry. Each fiber-optic dosimeter has an organic scintillator with a plastic optical fiber and it is embedded and arrayed in the plastic phantom to measure one-dimensional high energy electron beam profile of clinical linear accelerator. The scintillating lights generated from each sensor probe are guided by plastic optical fibers to the multi-channel photodiode amplifier system. We have measured one-dimensional electron beam profiles in a PMMA phantom according to different field sizes and energies of electron beam. Also, the isodose and three-dimensional percent depth dose curves in a PMMA phantom are obtained using a one-dimensional fiber-optic dosimeter with different electron beam energies.

  • PDF

A Study on the Sediment Transport using Radioisotope Tracer (방사성동위원소 추적자를 이용한 표사이동 추적실험)

  • Choi Byung-Jong;Jung Sung-Hee;Kim Jong-Bum;Lee Jong-Sup
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.16 no.3
    • /
    • pp.162-170
    • /
    • 2004
  • On the basis of the radiotracer technology and the related equipments which have been developed for its industrial application through the nuclear long-term research project, a radiotracer study on sediment transport was carried out as a part of the development of the radiotracer technology for a coastal environment. The crystalline material doped with iridium having a similar composition and specific gravity as those of the bedload sand collected from the research area was produced by the oxide-route method. A radioisotope container was specially designed to inject the radiotracer from 1 m above the sea bedload without radioactive contamination during the transport from the nuclear reactor at KAERI. The position data from the DGPS and the radiation measurement data were collected concurrently and stored by means of the application software programmed with the LabVIEW of the National Instrument. The position data was reprocessed to represent the real position of the radiation probe under water and not that of the DGPS antenna on board. The time dependency of the spatial distribution of the sediment was studied in the area through three tracking measurements after the iridium glass was injected. This trial application showed the potential of the radiotracer technology as an important role for maintaining and developing the coastal environment in the future.

MAXILLARY INCISOR CROWN-ROOT ANGLE(COLLUM ANGLE) IN DIFFERENT MALOCCLUSIONS (부정교합 분류에 따른 상악 중절치의 치관-치근 각도(Collum Angle)에 대한 연구)

  • Hong, Hee-Sook;Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.25 no.4
    • /
    • pp.453-463
    • /
    • 1995
  • Most commonly used axis for central incisors in lateral cephalometric radiographs is the line connecting root apex and incisor edge. However, crown axis and root axis do not always coincide in cases of malocclusion patients. The angle created by these axis are called the collum angle, which should be considered in orthodontic diagnosis and treatment. In this study, 31 Class I malocclusion, 30 Class II division 1 malocclusion, 31 Class II division 2 malocclusion, and 31 Class m malocclusion patients were selected and their collum angles were measured. Correlation between these angles and malocclusions was investigated, and the correlation analysis with other parameters in cephalometrics was done. The results were as follows ; 1. The mean collum angles according to the types of malocclusions are ; $3.11^{\circ}{\pm}3.54^{\circ}$ for Class I, $1.23^{\circ}{\pm}2.41^{\circ}$ for Class II division 1, $3.77^{\circ}{\pm}4.39^{\circ}$ for Class II division 2, and $3.90^{\circ}{\pm}4.08^{\circ}$ for Class III malocclusion. 2. Statistically significant differences in collum angles were noted between Class II division 1 group and Class II division 2 and Class III group. 3. Significant correlations were found between collum angles and other parameters used in cephalometrics, namely IMPA for Class I, Wits for Class II division 1, Overbite for Class II division 2 and for ClassIII.

  • PDF

A CEPHALOMETRIC STUDY ON CORRELATION BETWEEN MANDIBULAR SYMPHYSIS AND CRANIOFACIAL SKELETON (하악이부와 두개안면골격의 상관성에 관한 측모두부방사선 계측학적 연구)

  • Noh, Sang-Ho;Lee, Ki-Soo;Park, Yong-Kuk
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.119-127
    • /
    • 1997
  • The configuration of mandibular symphysis is likely to be dependent upon the genetic predeterminants and/or compensatory adjustments onto functional demands. The interrelation of morphological distinctives of symphysis in conjunction to the craniofacial skeleton had been scarcely anecdotal, therefore, the objective was to determine the correlation of morphological modifications between the mandibular symphysis and craniofacial complex. Lateral cephalometric headfilms of 212 subjects were employed for the conventional measurements. The proportion of chin height against chin depth length was referred as chin ratio, then, Low Symphysis (IS) and High Symphysis (HS) groups were turned out by means of the chin ratio. These samples yielded 35 in LS and 35 in HS groups. The data per capita were statistically analyzed and the following results were drawn ; 1. Overall characteristics of the craniofacial skeleton in HS group manifested hyperdivergence and LS group showed hypodivergence. 2. Gonial angle increased as chin ratio increased and was highly correlated to the chin ratio. 3. The chin ratio presented high correlation to the vertical face height, especially in terms of the chin height to anterior face height and the chin depth to posterior face height. 4. The morphological configuration of chin was hardly correlated with hyoid bone position.

  • PDF

Changes of mandibular dental arch during surgical-orthodontic treatment in skeletal class III malocclusion individuals (악교정수술을 받은 III급 부정교합자의 치료 전, 후의 하악치열궁 변화)

  • Nam, Hyung-Jin;Son, Woo-Sung;Park, Soo-Byung;Kim, Seong-Sik
    • The korean journal of orthodontics
    • /
    • v.38 no.4
    • /
    • pp.283-298
    • /
    • 2008
  • Objective: The purpose of this study was to investigate changes in the mandibular dental arch from presurgical orthodontic treatment and orthognathic surgery, and to evaluate the relationships between the pretreatment records and changes of mandibular dental arch in skeletal Class III malocclusion individuals. Methods: Lateral cephalometric radiographs and mandibular study models of 31 adults with skeletal class III malocclusion were taken and measured. All measurements were evaluated statistically by ANOVA, Scheffe's Post Hoc, and paired t-test, and correlation coefficients were evaluated. Results: No significant difference in Mn-LMMC, Mn-LIE, Mn-MnOcc was detected between pretreatment and presurgical groups. Statistically significant but low correlations were demonstrated between the initial arch length discrepancy (ALD) and change in ICW, IPW1 (r = 0.492, 0.615) and change in arch length (r = 0.641). No association was seen between the initial depth of curve of Spee and change in mandibular incisor angle and arch width or arch length. Regression analysis showed that the amount of change for arch length and IPW1 could be explained by 64.0% and 75.8% of the pretreatment variables respectively. Conclusions: This study suggests that orthognathic surgery results can be predictable by measuring the pretreatment records.

Automated Functional Morphology Measurement Using Cardiac SPECT Images (SPECT 영상을 사용한 기능적 심근형태의 자동 계측법 개발)

  • Choi, Seok-Yoon;Ko, Seong-Jin;Kang, Se-Sik;Kim, Chang-Soo;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.133-139
    • /
    • 2012
  • For the examination of nuclear medicine, myocardial scan is a good method to evaluate a hemodynamic importance of coronary heart disease. but, the automatized qualitative measurement is additionally necessary to improve the decoding efficiency. we suggests the creation of cardiac three-dimensional model and model of three-dimensional cardiac thickness as a new measurement. For the experiment, cardiac reduced cross section was obtained from SPECT. Next, the pre-process was performed and image segmentation was fulfilled by level set. for the modeling of left cardiac thickness, it was realized by applying difference equation of two-dimensional laplace equation. As the result of experiment, it was successful to measure internal wall and external wall and three-dimensional modeling was realized by coordinate. and, with laplace formula, it was successful to develop the thickness of cardiac wall. through the three-dimensional model, defects were observed easily and position of lesion was grasped rapidly by the revolution of model. The model which was developed as the support index of decoding will provide decoding information to doctor additionally and reduce the rate of false diagnosis as well as play a great role for diagnosing IHD early.