• Title/Summary/Keyword: 방사능 계측

Search Result 96, Processing Time 0.026 seconds

Determination of 129I in simulated radioactive wastes using distillation technique (증류법을 이용한 모의 방사성폐기물 중 129I 의 정량)

  • Choi, Ke-Chon;Song, Byung-Cheol;Han, Sun-Ho;Park, Yong-Joon;Song, Kyu-Seok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.3
    • /
    • pp.141-148
    • /
    • 2011
  • It is clarified in the radioactive waste transfer regulation that the concentration of radioactive waste for the major radio nuclide has to be examined when radioactive waste is guided to the radioactive waste stores. In case of the low level radioactive waste sample, the analytical results of radioactive waste concentration frequently show a value lower than minimum detectable activity (MDA). Since the MDA value basically depends on the amount of a sample, background value, measurement time, counting efficiency, and etc, it would be necessary to increase a sample amount with a intention of minimizing MDA. In order to measure a concentration of $^{129}I$ in low and medium level radioactive waste, $^{129}I$ was collected by using a distillation technique after leaching the simulated radioactive waste sample with a non-volatile acid. The recovery of $^{129}I$ measured was compared with that measured with column elution technique which is a conventional method using an anion-exchange resin. The recovery of inactive iodide by using the distillation method and column elution were found as $86.5{\pm}0.9%$ and $87.3{\pm}2.7%$, respectively. The recovery and MDA value calculated for distillation technique when 100 g of extracted solution of $^{129}I$ was taken, were found to be $84.6{\pm}1.6%$ and $1.2{\times}10^{-4}Bq/g$, respectively. Consequently, the proposed technique with simplified process lowered the MDA value more than 10 times compared to the column elution technique that has a disadvantage of limited sampling amount.

Factors Affecting the Minimum Detectable Activity of Radioactive Noble Gases (방사성 노블가스 측정을 위한 최소검출방사능 산출의 조절인자)

  • Park, Ji-young;Ko, Young Gun;Kim, Hyuncheol;Lim, Jong-Myoung;Lee, Wanno
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.301-308
    • /
    • 2018
  • Anthropogenic radioactive noble gases formed by nuclear fission are significant indicators used to monitor the nuclear activity of neighboring countries. In particular, radioactive xenon, owing to its abundant generation and short half-life, can be used to detect nuclear testing, and radioactive krypton has been used as a tracer to monitor the reprocessing of nuclear fuels. Released radioactive noble gases are in the atmosphere at infinitesimal amounts due to their dilution in the air and their short half-life decay. Therefore, to obtain reliable and significant data when performing measurement of noble gases in the atmosphere, the minimum detectable activity (MDA) for noble gases should be defined as low as possible. In this study, the MDA values for radioactive xenon and krypton were theoretically obtained based on the BfS-IAR system by collecting both noble gases simultaneously. In addition, various MDA methods, confidence level and analysis conditions were suggested to reduce and optimize MDA with an assessment of the factors affecting MDA. The current investigation indicated that maximizing the pretreatment efficiency and performance maintenance of the counter were the most important aspects for Xe. In the case of Kr, since sample activities are much higher than those of Xe, it is possible to change the target MDA or to simplification of the analysis system.

대기 중 노블가스 분석

  • Lee, Wan-Ro;Lee, Seung-Il;Choe, Sang-Do;Jo, Yeong-Hyeon;Jeong, Geun-Ho;Kim, Hui-Ryeong;Lee, Chang-U;Choe, Geun-Sik;Gang, Mun-Ja;Jeon, In;Geum, Dong-Gwon
    • 대한방사선방어학회:학술대회논문집
    • /
    • 2010.04a
    • /
    • pp.168-169
    • /
    • 2010
  • PDF

한국에서 일하는 외국인 과학기술자 - 한국표준과학연구원의 폴란드 과학자 '리자드 브로다 박사'

  • Korean Federation of Science and Technology Societies
    • The Science & Technology
    • /
    • v.33 no.3 s.370
    • /
    • pp.76-77
    • /
    • 2000
  • 한국의 우수두뇌유치 프로그램에 의해 지난해 2월부터 한국표준과학연구원에서 근무하고 있는 폴란드 과학자 리자드 브로다박사는 현재 베타방출핵종을 액체섬광계수방법으로 표준화하는 연구를 수행하고 있다. 그가 재직중인 폴란드방사성동위원소센터와 한국표준과학연구원 방사능그룹은 동시계수를 이용한 방사성 핵종의 표준화 등 비슷한 내용을 연구하고 있으므로 계측문제를 함께 풀어나가면서 훨씬 빠른 발전이 이루어질 것이라고 내다보았다.

  • PDF

Studies on Phosphorus-32 Labeling of the House Fly ( I ) (Phosphorus-32에 의한 집파리의 표식효과 (I))

  • Ryu J.;Chung K. H.;Kwon S. H.;Kim H. W.
    • Korean journal of applied entomology
    • /
    • v.13 no.2 s.19
    • /
    • pp.93-97
    • /
    • 1974
  • This paper describes experiments made to develop a technique for marking insects and get the informations for ecological studies as a means of tagging flies with radioactive phosphorus, and also to learn the effect on the subsequent generation of flies. Tests were conducted with house flies, Musca domestica L. emerged front the larvae that had reared in a media containing various concentrations of P-32. Radioactivity of the flies was measured with end-window type $(2mg/cm^2)$ Geiger-Muller counter and proportional counter made by Aloka. In following the daily increases in counting rates by 6-day-old larvae it was apparent the larvae in the starting media containing the higher concentrations of P-32 were showing high counting rates. It was found that about 13.2 per cent of the radioactive material remained in the empty puparia after the flies emerged. Radioactivity of the emerged flies decreased gradually and the biological halflife of phosphorus-32 was approximately 6.14 days with considerable variation. A significant amount of P-32 were detected in the abdominal and thoracic sections as compared with other parts of adult. The activity of phosphorus·32 in eggs and larvae produced by adults reared in medium containing 0.2 microcurie or more of P-32 per gram were readily detected with Geiger-Mi·lier counter. On the other hand, the radioactivity of eggs and larvae produced by the treated males crossed with untreated normal females could be only detected in the medium containing more of 2.0 microcurie with G.M. counter. There was no apparent damage to the flies at dosages as high as 0.5 microcurie per gram of medium. For field studies a concentration of 0.5 microcurie of P-32 per gram of artificial medium appears to give adequate labeling for positive identification of flies and their egg masses.

  • PDF

A Study of $^{222}Rn\;and\;^{226}Ra$ Analysis in the Groundwater by LSC (액체섬광계수기에 의한 지하수중의 $^{222}Rn$$^{226}Ra$ 분석법 연구)

  • Woo, Hyung-Joo;Yoon, Yoon-Yeol;Cho, Soo-Young;Chun, Sang-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.4
    • /
    • pp.275-283
    • /
    • 1995
  • PERALS(Photon Electron Rejecting Alpha Liquid Scintillation) spectrometry coupled with solvent extraction method has been set up for the analysis of $^{222}Rn\;and\;^{226}Ra$ in the groundwater. This analytical method offers low background, better energy resolution and lower quenching problem than the other techniques. By the analysis of NIST SRM 4966 $^{226}Ra$ standard, the analytical accuracy and precision were found to be 3% and 1%, respectively, and the relative standard deviation of the recovery of Rn extraction between pH2 and pH10 was 7%. Detection limits of $^{222}Rn$ and $^{226}Ra$ for 10 hours counting were counted to be $0.42 pCi/{\iota}\;and\;0.016 pCi/{\iota}$, respectively. For the test analysis of $^{222}Rn\;and\;^{226}Ra$ in the graundwater, hot spring water samples of 17 regions were analyzed. The concentration of $^{222}Rn$ were in the range of $90{\sim}5200pCi/{\iota}$ and average value was $1470pCi/{\iota}\;^{226}Ra$ concentration showed a peak value of $97.9pCi/{\iota}$ in a Kangwon region, but the average value was $1.14pCi/{\iota}$ except that region.

  • PDF

Optimization of $CO_2$ Direct Absorption Method for the Determination of Carbon-14 in Environmental Samples (환경시료중의 방사성탄소 측정을 위한 $CO_2$ 직접흡수법의 최적화 연구)

  • Cho, Soo-Young;Woo, Hyung-Joo;Chun, Sang-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.237-242
    • /
    • 1998
  • The goal of this work was to optimize the liquid scintillation counting techniques for the determination of C-14 in environmental samples such as biological and air samples. Carbon-14 activities in most environmental samples were measured with direct $CO_2$ absorption method. The highest figure of merit was found through the variation of Carbosorb $E^{TM}$ and Permatluor $V^{TM}$ ratio, in the measurement windows. The best condition was 1:1 volume ratio. Average 2.35 g of $CO_2$ was reproducibly absorbed in the 20 ml mixture within 40 min. The counting efficiency determined by repeated analysis of NIST oxalic acid standard and the background count rate were measured to be $58.8{\pm}1.4%$ and $1.88{\pm}0.06\;cpm$, respectively in case of saturated solution. The correction curves of counting efficiency for partially saturated solutions and for saturated solutions with quenching were prepared, respectively. The overall uncertainty of the sample specific activity for near background levels was estimated to be about 7 % for 4 hours counting at 95 % confidence level. The long-term stability of samples has been checked for all the counting techniques over a two week periods, and no apparent change in counting efficiency and background level was found at that time.

  • PDF

The in Vivo Distribution of $^{99m}Tc-Phytate$ IL-2 Complex on Selective Splenic Arterial Injection (비장동맥에 선택적으로 투여한 Interleukin-2와 $^{99m}Tc-Phytate$ 혼합물의 생체내 분포)

  • Zeon, Seok-Kil;Lee, Hee-Jung;Sohn, Soo-Sang
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.124-126
    • /
    • 1992
  • Interleukin-2 (IL-2)는 많은 immunoenhancing lymphokine의 한 종류로서 lymphokine activiated killer (LAK) cell의 생성을 자극시켜 흑종의 종양세포를 죽인다고 알려져 있다. 최근 간종양에서 비장동맥 또는 간동맥으로 투여한 IL-2가 비장의 임파계를 자극하여 LAK cell을 생성하여 어느정도효과가 있음이 밝혀지면서, 여러가지의 투여 방법이 시도되고 있다. 그러나 각종의 투여 방법에서 실제로 투여한 IL-2의 인체내 분포에 관한 연구는 없다. 저자들은 비정맥과 간문맥에 이상이 없는 증례의 비동맥에 IL-2와 $^{99m}Tc-phytate$ 혼합물을 투여하고, IL-2의 생체에서의 비장과 간에 어떻게 분포하는지 알아보기 위하여 $^{99m}Tc$의 radioactivity를 계측하여 보았다. 6예의 간세포암과 3예의 위암으로부터의 전이성간암에서 동맥조영술적방법을 이용하여 초선택적 비장동맥에 투여한 IL-2와 $^{99m}Tc-phytate$ 혼합물이 비장 27%, 간73%의 분포를 보여 비장을 거쳐온 $^{99m}Tc$의 방사능이 간에 많이 침착함을 확인하였고 간과 비장이외의 부위 즉 골수, 복수 또는 폐장이나 늑막에는 전혀 방사능 분포가 없음을 알 수 있었다. 따라서 비정맥이나 간문백에 이상이 없는 증례에서 IL-2의 비장동맥 투여는 목적하는 바 IL-2의 생체내 분포를 이룩할 수 있을 것으로 사료된다.

  • PDF

A Study on Gaseous Effluents from BMRR (Brookhaven 醫學硏究用 原子爐에서의 氣體噴出物에 관한 硏究)

  • Hwang, Sun-Tae;Park, Tae-Soon;Hah, Suck-Ho;Choi, Sung-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.1-10
    • /
    • 1988
  • Brookhaven 의학연구용 원자로에서 방출되는 기체분출물에 관하여 연구 되었다. 모든 기체시료는 $\gamma$-선 분광계측에 의하여 분석되었다. 시료 중에 존재하는 것으로 확인된 핵종으로서, $^{82}Cl(T_{1/2}$ = 35.30 시간) 이 가장 뚜렷하였다. 그 외의 확인된 핵종은 $^{38}Cl(T_{1/2}$ = 37.24분), $^{41}Ar(T_{1/2}$ = 1.82시간), $^{106}Rh(T_{1/2}$ = 29.80묘), $^{133}Te(T_{1/2}$ = 12.45분)이었다. 3MW 원자로 출력에서 pre-filter bank를 통과한 기체분출물 중에서 $$^{41}Ar$의 농도는 2.436Bq/cc로 계산됨으로써 $^{41}Ar$의 방사능 방출율은 8.51 ${\times}10^9$Bq/MW - h로 산정되었다. filter bank의 방사능 원거효율(%)은 $^{38}Cl$의 경우 97.84%, $^{41}Ar$은 14.15%, ^{82}Br$은 98.70% 그리고 $^{106}Rh$은 98.81% 각각 산정되었다. 한편, charcoal trap과 millipore filter 에서 확인된 기타 핵종들로서 $^{24}Na$, $^{72}Ga$, $^{92}Sr$, $^{97}Zr$, $^{132}I$, $^{133}Te$, $^{141}Ce$, $^{153}Sm$$^{154}Pm$은 filter bank에 의해서 완전히 제거되었다.

  • PDF

Corrections of Self-Absorption Effect Using the Monte Carlo Method in the Radioactivity Analysis of Environmental Samples (환경시료의 방사능 분석에서 Monte Carlo 방법을 이용한 자체흡수 효과 보정)

  • Seo, Bum-Kyoung;Lee, Dae-Won;Lee, Kil-Yong;Yoon, Yoon-Yeol;Yang, Tae-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.2
    • /
    • pp.51-58
    • /
    • 2001
  • In the low level radioactivity measurement, such as environmental radioactivity, there were used commonly cylindrical and Marinelli type beakers by means of measurement container. If there are differences in the matrix density or sample height between standard source and sample, it must be determined full energy peak efficiency considering self absorption effect. In this paper, we compared measured efficiency with calculated full energy peak efficiencies in the HPGe detector using the Monte Carlo method. For cylindrical container, we calculated the variation of the efficiency with sample height. Also, we calculated the variation of the detection efficiency with apparent density in the cylindrical and Marinelli container. It was seen that it need to be corrected for self absorption in the energy range of below 1000keV. Also, in order to verify the validity of calculation, we compared the calculated value with reference value using NIST SRM 4353 reference soil.

  • PDF