• Title/Summary/Keyword: 방사능오차분석

Search Result 35, Processing Time 0.026 seconds

Determination of $^{14}C$ in Environmental Samples Using $CO_2$ Absorption Method ($Co_2$ 흡수법에 의한 환경시료중 $^{14}C$ 정량)

  • Lee, Sang-Kuk;Kim, Chang-Kyu;Kim, Cheol-Su;Kim, Yong-Jae;Rho, Byung-Hwan,
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.1
    • /
    • pp.35-46
    • /
    • 1997
  • A simple and precise method of $^{14}C$ was developed to analyze $^{14}C$ in the environment samples using a commercially available $^{14}CO_2$ absorbent and a liquid scintillation counter. An air sampler and a combustion system were developed to collect HTO and $^{14}CO_2$ in the air and the biological samples simultaneously. The collection yield of $^{14}CO_2$ by the air sampler was in the range of 73-89% . The yield of the combustion system was 97%. In preparing samples for counting, the optimum ratio of $CO_2$ absorbent to the scintillator for mixing was 1:1. No variation of the specific activity of $^{14}C$ in the counting sample was observed up to 70 days after preparation of the samples. The detection limit for$^{14}C$ was 0.025 Bq/gC, which is the level applicable to the natural level of $^{14}C$. The analytical result of $^{14}C$ obtained by the present method were within ${\pm}6%$ of the relative error from the one by the benzene synthesis. The specific activity of $^{14}C$ in the air collected at Taejon during the period of October 1996 ranged from 0.26 to 0.27 Bq/gC. The specific activity of $^{14}C$ in the air collected at 1km from the Wolsong nuclear power plant a 679 MWe PHWR, was $0.54{\pm}0.03$ Bq/gC. The ranges of specific activities of $^{14}C$ in the pine needles and the vegetations from the areas around the Wolsong nuclear power plant were 0.56-0.67 Bq/gC and 0.23-1.41 Bq/gC, respectively.

  • PDF

A Study on a position detection of radiation using CCD camera (영상센서를 이용한 방사선원 위치탐지 연구)

  • Lee, Nam-Ho;Choi, Chang-Whan;Shin, Ho-Chul;Jun, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.324-326
    • /
    • 2006
  • CCD형 영상소자는 방사선 피폭 시 표면과 격자내부에 모두 손상을 받게 되며, 감마방사선이나 X선과 같은 고에너지의 이온화 방사선에 노출될 경우 격자 실리콘 내부에 전자-전공쌍(Electron-hole pair, EHP)이 발생된다. 이러한 EHP는 CCD의 순간 출력 광전류로 변환되어 백색 화소 형태의 영상잡음으로 가시화되며, 이 화소 수는 피폭 방사선량에 비례하여 증가하는 특성을 지니고 있다. 따라서 출력 영상정보를 분석하면 조사된 방사선의 양과 특성을 측정할 수 있다. 본 연구에서는 CCD를 이용하여 가상의 방사능 물질 누출 공간에서 방사선원의 방향과 거리정보를 고속으로 탐지하기 위한 장치와 고속 측정 알고리즘을 구현하고 실제 방사선장에서 실증시험을 수행하였다. 방사선 탐지기는 콘형 납 콜리메이터(Collimator)와 가시광 변환용 신틸레이터(CsITl) 및 차폐체로 구성된 센서부와 제어 및 방사광 신호처리를 수행하는 PC부로 구성된다. 감마방사선($^{60}Co$) 방사선장 실증시험에서 방사선원간 거리 83cm에서 측정된 거리 탐지는 5.3%의 오차로 확인되었다. 이 방사선 탐지기는 임의의 고방사선 누출사고에 대한 초기대응 작업을 수행하기 위한 무인 이동로봇용 방사선 탐지기로 활용이 가능하다.

  • PDF

Research on Measurement Condition Establishment of a Liquid Scintillation Counter System (액체섬광계수기 장비의 계측조건 확립에 관한 연구)

  • Park, Eung-Seop;Han, Sang-Jun;Lee, Seung-Jin;Kim, Hee-Gang;Lee, Na-Young;Mun, Ji-Yeon
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.155-164
    • /
    • 2006
  • It is judged that there could be certainty in every process of analyzing environmental samples using Liquid Scintillation Counter. Therefore, this study focuses on quantitative evaluation on uncertainty in an effort to analyze comparatively accurately environmental samples. For this, after parameters which can have an effect on uncertainty was derived, the evaluation on each parameter was tamed out. The results of analysis of each parameter showed that the effect according to the weight difference of Teflon vial did not appear, and that standard deviations of SQP(E) averages reached saturation point at $75{\sim}90$ sec at the result of making increases step by step the irradiation time of External standard, and that values measured by repeat method produces good results compared with replicate. Also, conclusion was derived that analysis on sample after it is left in cold and dark room at least above 1,000 minutes have to be carried out, and the result of carrying out verification on results measured as well as equipment itself using radioactivity-error-analysis and chi-square test, resonable result was derived.

Quantitative Comparison of Univariate Kriging Algorithms for Radon Concentration Mapping (라돈 농도 분포도 작성을 위한 단변량 크리깅 기법의 정량적 비교)

  • KWAK, Geun-Ho;KIM, Yong-Jae;CHANG, Byung-Uck;PARK, No-Wook
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.1
    • /
    • pp.71-84
    • /
    • 2017
  • Radon, which enters the interior environment from soil, rocks, and groundwater, is a radioactive gas that poses a serious risk to humans. Indoor radon concentrations are measured to investigate the risk of radon gas exposure and reliable radon concentration mapping is then performed for further analysis. In this study, we compared the predictive performance of various univariate kriging algorithms, including ordinary kriging and three nonlinear transform-based kriging algorithms (log-normal, multi-Gaussian, and indicator kriging), for mapping radon concentrations with an asymmetric distribution. To compare and analyze the predictive performance, we carried out jackknife-based validation and analyzed the errors according to the differences in the data intervals and sampling densities. From a case study in South Korea, the overall nonlinear transform-based kriging algorithms showed better predictive performance than ordinary kriging. Among the nonlinear transform-based kriging algorithms, log-normal kriging had the best performance, followed by multi-Gaussian kriging. Ordinary kriging was the best for predicting high values within the spatial pattern. The results from this study are expected to be useful in the selection of kriging algorithms for the spatial prediction of data with an asymmetric distribution.

Effects of AMAD, Absorption Type, and Intake Pattern on the Result of Evaluation for Internal Dose by Inhalation of Uranium (우라늄의 입자크기, 흡수형태 및 섭취형태가 내부피폭선량 평가 결과에 미치는 영향)

  • Lee, Jong-Il;Lee, Tae-Young;Chang, Si-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.4
    • /
    • pp.321-325
    • /
    • 2003
  • The effects of AMAD, absorption type, and intake pattern were compared and analysed for the internal dose evaluation of workers who chronically inhale uranium. The committed effective doses$(E_{50})$ based on AMAD, absorption type, and intake pattern were evaluated using 3 monthly lung predicted monitoring data due to a chronic intake of uranium for 5 years. The relative error ranges of $E_{50}$ evaluated with each AMAD$(0.1{\sim}10{\mu}m)\;to\;E_{50}$ evaluated with $5{\mu}m$ AMAD were $-37.0{\sim}49.8%$, and the relative error ranges of En evaluated with Type M to $E_{50}$ evaluated with Type S were $15.9{\sim}56.6%$, and the relative error ranges of $E_{50}$ evaluated with an acute intake to $E_{50}$ evaluated with a chronic intake were $0.55{\sim}4.52%$. Thus AMAD and the absorption type affected the results of $E_{50}$, but the intake pattern didn't really affect the results of $E_{50}$.

Geostatistical Interpretation of Cs-137 and K-40 Result of the Lithosphere in the Vicinity of Youngkwang Nuclear Power Plant (지구통계학적 방법에 의한 영광원전주변 토층내 Cs-137 및 K-40 측정 결과의 해석)

  • 김경웅;이재석;문승현;박철승;고일원;고은정;조병옥;정철영;전수열
    • Economic and Environmental Geology
    • /
    • v.35 no.6
    • /
    • pp.545-552
    • /
    • 2002
  • In order to investigate the influence of nuclear power plant operation on its nearby environment, soil, stream and marine sediment samples were collected in the vicinity of the Youngkwang Nuclear Power Plant in Korea, and analyzed for artificial and natural radionuclide radioactivity. From the analytical result, Cs-137 was detected in most soil samples. but it may have been derived fiom past nuclear weapon tests because Cs-134 having short half-live was not detected. The radioactivities of Cs-137 in the sediment samples were also detected which are within the normal range in the sediments based upon the published literature between 1997 and 1999. For the quality control of radioactivity analysis of environmental samples, sets of marine sediments in the Gamami area were analyzed using two HPGe Gamma-ray Spectroscopes (30% and 45%) according to the geostatistical sampling strategy, and Cs-137 and K-40 results were interpreted by analysis of variance (ANOVA). In the two-way ANOVA, variances derived from the geochemical variation were significant, but errors from sampling and analytical procedures are negligible. In conclusion. all the radioanalytical procedures of this study including sampling are validated to be acceptable.

Assessment of the Models for Predicting the Thermal Conductivity of Saturated Kaolinite (포화된 카올리나이트를 이용한 열전도계수 예측모델의 신뢰성 검토)

  • Lee, Jangguen;Kim, Hakseung;Kang, Jaemo;Kim, Youngseok;Bae, Gyujin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.3
    • /
    • pp.21-27
    • /
    • 2012
  • Estimating the thermal conductivity of clayey soils is important for enhancing the performance of geoengineering structures in cold regions and clay barriers for nuclear waste repositories, but specimen disturbance, saturation, and heat boundary conditions of the test apparatus hinder reliable measurements of the thermal conductivity of saturated clayey soils. This paper presents the results of an experimental study carried out using modified consolidation tests with the needle probe method to measure thermal conductivity. Experimental consolidation tests with saturated kaolinite were performed to investigate the effect of effective stress and dry density on thermal conductivity for saturated kaolinite. In addition, thermal conductivity of soil particles were thoroughly investigated and experimental results were used to evaluate the accuracy of the models to predict thermal conductivity.

Effectiveness Evalution of 18F-FDG Auto Dispenser (RIID: Radiopharmaceutical Intelligent Dispenser) (18F-FDG 자동분주기 사용에 따른 유용성 평가)

  • Yoo, Moon-Gon;Moon, Jae-Seung;Kim, Su-Geun;Shin, Min-Yong;Kim, Seung-Chul;Lee, Tea-hun;An, Sung-Hyeun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.79-83
    • /
    • 2018
  • Purpose $^{18}F-FDG$, which is commonly used in PET-CT examinations, is low in capacity and it is difficult to keep the amount of radioactivity busy when the specific activity is high, increasing the amount of space dose and radioactive contamination in the distribution room. Therefore, while evaluating the actual dose administered to patients during the manual dispense process, the medical institution intends to assess the usefulness of the auto dispenser by comparing the differences from the actual dose administered to the patient using the new automatic dispense. Materials and Methods From July 2016 to December 2016, 846 patients were manually administered by workers using $^{18}F-FDG$ and $^{18}F-FDG$ 906 patients were using auto dispenser from July 2017 to December 2017. Results Capacity administered to patients during the manual dispense averaged $35.41{\pm}27.79%$ compared to the recommended dose, and the auto dispenser process showed a small difference of $-2.15{\pm}3.99%$ compared to the recommended dose(p<0.05). Conclusion Working people did not have to touch radioactive medicines directly while they were busy in the auto dispenser, and because of the availability of other tasks far away, the time and distance to receive the exposure were also advantageous. It is believed that future use by many medical institutions will not only reduce the dose to patients but also help reduce the exposure dose to workers.

Study the Analysis of Comparison with AROI and MROI Mode in Gated Cardiac Blood Pool Scan (게이트심장혈액풀 스캔에서 자동 관심영역 설정과 수동 관심영역 설정 모드의 비교 분석에 관한 고찰)

  • Kim, Jung-Yul;Kang, Chun-Koo;Kim, Yung-Jae;Park, Hoon-Hee;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.222-228
    • /
    • 2008
  • Purpose: The objectives of this study were to compare the left ventricle ejection fraction (LVEF) from gated cardiac blood pool scan (GCBP) for analysis auto-drawing region of interest mode (AROI) and manual-drawing region of interest mode (MROI), respectively. To evaluation the relationships between values produced by both ROI modes. Materials and Methods: Gated cardiac blood pool scan using in vivo method Tc-99m Red Blood Cell were performed for 33 patients (mean age: $53.2{\pm}13.2\;y$) with objective of chemotherapy using single head gamma camera (ADAC Laboratories, Milpitas, CA). Left ventricular ejection fraction was automatically and manually measured, respectively. Results: There was significant difference statistically between AROI and MROI ($LVEF^{AROI}$: $71.4{\pm}12.4%$ vs. $LVEF^{MROI}$: $65.8{\pm}5.9%$, p=0.003). Intra-observer agreements in AROI was higher than MROI ($\gamma^{AROI}=0.964$, Cronbach's $\alpha^{AROI}=0.986$ vs. $\gamma^{MROI}=0.793$, Cronbach's $\alpha^{MROI}=0.911$), either. Additionally, there was no significant difference statistically at best septal view (${\Delta}LVEF^{BSV}=0.7{\pm}2.3%$, p=0.233), however statistically significant difference was found at badly separated septal view (${\Delta}LVEF=10.9{\pm}11.4%$, p=0.001). Moreover, Intra-observer agreements in best septal view was higher than badly separated septal view ($\gamma^{BSV}=0.939$, Cronbach's $\alpha^{BSV}=0.978$; $\gamma=0.948$, Cronbach's $\alpha=0.981$ at AROI, $\gamma^{BSV}=0.836$, Cronbach's $\alpha^{BSV}=0.936$; $\gamma=0.748$, Cronbach's $\alpha=0.888$ at MROI). Conclusion: When best septal view was acquired, LVEF by AROI and MROI indicated not different. Comparing Intra-observer agreements with AROI and MROI, the AROI tended to show higher. Therefore, it is considered that the AROI than MROI is valuable in reproducibility and objective when ROI analysis by acquire left ventricular of best septal view.

  • PDF

Thermoluminescence Dating of Pottery Shards by Subtraction Method (Subtraction 방법을 이용한 TL 연대측정법에 의한 토기 시편의 절대연대 결정)

  • Shin, Hyun-Sang;Lee, Chang-Woo;Nam, Young-Mee;Jee, Kwang-Yong;Park, Byung-Bin
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.403-411
    • /
    • 2000
  • This study described a method of thermoluminescence dating of pottery shards using subtraction method. TL measurement was achieved using two different types of samples prepared by quartz inclusion method and fine-grain technique. Fine grains (size range: $5-10{\mu}m$) were separated by suspending grounded pottery samples into acetone solution and sedimentation quantitatively. In quartz inclusion method quartz grains in the size range of 90 to $125{\mu}m$ diameter were obtained by extracting the quartz crystals embed in the pottery shards and etching them with 1.0 M HF solutions. The archaeological dose of both the quartz and fine grains was determined from the dose calibration curves obtained from sequential irradiation of $^{137}Cs$ gamma and $^{241}Am$ alpha source to the samples and TL measurement of natural samples, in which the alpha dose of 4.60 Gy for the Packjae pottery was obtained using subtraction method. Annual alpha dose rates ($3.05{\pm}0.11$ mGy/yr.) were determined by the analysis of U, Th contents in the pottery shards and evaluation of the values with Bell's equation. Dividing the alpha dose accumulated in the pottery shards by the annual alpha dose rate, we found age of approximately $1508{\pm}80$ years B.P. (AD. ca. 492 yr.) for the Packjae pottery. It matches well with the archeological age estimate (middle of 5th century) within 10 percent uncertainty and thereby conforms the age of the pottery sample.

  • PDF