• Title/Summary/Keyword: 방법론 평가

Search Result 3,686, Processing Time 0.033 seconds

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.

Evaluation of usefulness of the Gated Cone-beam CT in Respiratory Gated SBRT (호흡동조 정위체부방사선치료에서 Gated Cone-beam CT의 유용성 평가)

  • Hong sung yun;Lee chung hwan;Park je wan;Song heung kwon;Yoon in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.61-72
    • /
    • 2022
  • Purpose: Conventional CBCT(Cone-beam Computed-tomography) caused an error in the target volume due to organ movement in the area affected by respiratory movement. The purpose of this paper is to evaluate the usefulness of accuracy and time spent using the Gated CBCT function, which reduces errors when performing RGRT(respiratory gated radiation therapy), and to examine the appropriateness of phase. Materials and methods: To evaluate the usefulness of Gated CBCT, the QUASARTM respiratory motion phantom was used in the Truebeam STxTM. Using lead marker inserts, Gated CBCT was scaned 5 times for every 20~80% phase, 30~70% phase, and 40~60% phase to measure the blurring length of the lead marker, and the distance the lead marker moves from the top phase to the end of the phase was measured 5 times. Using Cedar Solid Tumor Inserts, 4DCT was scanned for every phase, 20-80%, 30-70%, and 40-60%, and the target volume was contoured and the length was measured five times in the axial direction (S-I direction). Result: In Gated CBCT scaned using lead marker inserts, the axial moving distance of the lead marker on average was measured to be 4.46cm in the full phase, 3.11cm in the 20-80% phase, 1.94cm in the 30-70% phase, 0.90cm in the 40-60% phase. In Fluoroscopy, the axial moving distance of the lead marker on average was 4.38cm and the distance on average from the top phase to the beam off phase was 3.342cm in the 20-80% phase, 3.342cm in the 30-70% phase, and 0.84cm in the 40-60% phase. Comparing the results, the difference in the full phase was 0.08cm, the 20~80% phase was 0.23cm, the 30~70% phase was 0.10cm, and the 40~60% phase was 0.07cm. The axial lengths of ITV(Internal Target Volume) and PTV(Planning Target Volume) contoured by 4DCT taken using cedar solid tumor inserts were measured to be 6.40cm and 7.40cm in the full phase, 4.96cm and 5.96cm in the 20~80% phase, 4.42cm and 5.42cm in the 30~70% phase, and 2.95cm and 3.95cm in the 40~60% phase. In the Gated CBCT, the axial lengths on average was measured to be 6.35 cm in the full phase, 5.25 cm in the 20-80% phase, 4.04 cm in the 30-70% phase, and 3.08 cm in the 40-60% phase. Comparing the results, it was confirmed that the error was within ±8.5% of ITV Conclusion: Conventional CBCT had a problem that errors occurred due to organ movement in areas affected by respiratory movement, but through this study, obtained an image similar to the target volume of the setting phase using Gated CBCT and verified its usefulness. However, as the setting phase decreases, the scan time was increases. Therefore, considering the scan time and the error in setting phase, It is recommended to apply it to patients with respiratory coordinated stereotactic radiation therapy using a wide phase of 30-70% or more.

A study of the plan dosimetic evaluation on the rectal cancer treatment (직장암 치료 시 치료계획에 따른 선량평가 연구)

  • Jeong, Hyun Hak;An, Beom Seok;Kim, Dae Il;Lee, Yang Hoon;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.171-178
    • /
    • 2016
  • Purpose : In order to minimize the dose of femoral head as an appropriate treatment plan for rectal cancer radiation therapy, we compare and evaluate the usefulness of 3-field 3D conformal radiation therapy(below 3fCRT), which is a universal treatment method, and 5-field 3D conformal radiation therapy(below 5fCRT), and Volumetric Modulated Arc Therapy (VMAT). Materials and Methods : The 10 cases of rectal cancer that treated with 21EX were enrolled. Those cases were planned by Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28) and AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). 3fCRT and 5fCRT plan has $0^{\circ}$, $270^{\circ}$, $90^{\circ}$ and $0^{\circ}$, $95^{\circ}$, $45^{\circ}$, $315^{\circ}$, $265^{\circ}$ gantry angle, respectively. VMAT plan parameters consisted of 15MV coplanar $360^{\circ}$ 1 arac. Treatment prescription was employed delivering 54Gy to recum in 30 fractions. To minimize the dose difference that shows up randomly on optimizing, VMAT plans were optimized and calculated twice, and normalized to the target V100%=95%. The indexes of evaluation are D of Both femoral head and aceta fossa, total MU, H.I.(Homogeneity index) and C.I.(Conformity index) of the PTV. All VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : D of Rt. femoral head was 53.08 Gy, 50.27 Gy, and 30.92 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. D of Rt. aceta fossa was 54.86 Gy, 52.40 Gy, 30.37 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. The maximum dose of both femoral head and aceta fossa was higher in the order of 3fCRT, 5fCRT, and VMAT treatment plan. C.I. showed the lowest VMAT treatment plan with an average of 1.64, 1.48, and 0.99 in the order of 3fCRT, 5fCRT, and VMAT treatment plan. There was no significant difference on H.I. of the PTV among three plans. Total MU showed that the VMAT treatment plan used 124.4MU and 299MU more than the 3fCRT and 5fCRT treatment plan, respectively. IMRT verification gamma test results for the VMAT plan passed over 90.0% at 2mm/2%. Conclusion : In rectal cancer treatment, the VMAT plan was shown to be advantageous in most of the evaluation indexes compared to the 3D plan, and the dose of the femoral head was greatly reduced. However, because of practical limitations there may be a case where it is difficult to select a VMAT treatment plan. 5fCRT has the advantage of reducing the dose of the femoral head as compared to the existing 3fCRT, without regard to additional problems. Therefore, not only would it extend survival time but the quality of life in general, if hospitals improved radiation therapy efficiency by selecting the treatment plan in accordance with the hospital's situation.

  • PDF

Efficacy and Safety of Early Bronchoscopy in Patients with Hemoptysis (객혈환자에서 조기기관지경의 유용성 몇 안정성)

  • Kim, Ho-Cheol;Cheon, Eun-Mee;Chung, Man-Pyo;Kim, Ho-Joong;Choi, Dong-Chull;Kwon, O-Jung;Rhee, Chong-H.;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.391-400
    • /
    • 1997
  • Background : Bronchoscopy is an essential procedure for identifying the bleeding site and evaluating cause of hemoptysis. However, it is controversial regarding to the timing of bronchoscopy in patients with hemoptysis. Early bronchoscopy, which was performed during hemoptysis or with 48hour after cessation of bleeding, was better for identifying the site of bleeding compared with delayed bronchoscopy, which was performed 48 hours after cessation of bleeding. The diagnostic yield of identifying the bleeding site by bronchoscopy was variable in reported literature and the safety of early bronchoscopy was not mentioned in previous literature. Therefore, we evaluated the efficacy and safety of early bronchoscopy in patients with hemoptysis. Method : From October 1994 to August 1996 in Samsung Medical Center, bronchoscopy was performed in patients with hemoptysis. Early bronchoscopy was performed prospectively during hemoptysis or within 48 hours after cessation of bleeding from May 1995 to August 1996. Delayed bronchoscopy group included patients who did not received early bronchoscopy at the same period or in whom bronchoscopy was performed 48 hour after cessation of bleeding from October 1994 to May 1995. Results : Early bronchoscopy group was performed 73 times in 71 patients. Delayed bronchoscopy was performed in 57 times in 55 patients. There was no difference as to amount and underlying cause of hemoptysis between both groups. Indentification of bleeding site by visualizing active bleeding was significantly higher in early bronchoscopy (38.3%) than delayed bronchoscopy group (8.7%)(p < 0.05). Indentification of bleeding site by bleeding after clot removal was 8 in early and 10 in delayed bronchoscopy. Indentification of bleeding site by visualizing active bleeding and bleeding after clot removal was 36 in early and 15 patients in delayed bronchoscopy(p > 0.05). Causes of hemoptysis was found in 18 patients in early and 16 patients in delayed bronchoscopy group. patients who had early bronchoscopy underwent surgery. We diagnosed the site of bleeding in 4 patients preoperatively. In 3 patients we made a treatment plan promptly right after bronchoscopy. Among early bronchoscopy group, bleeding over 100cc during bronchoscopy occurred in 2 patients. In early bronchoscopy group there was no other major complication during bronchoscopy. Conclusion : In patients with hemoptysis, early bronchoscopy which performed within 48 hours after cessation of bleeding was more effective procedure for identifying the bleeding site than delayed bronchoscopy which was performed after 48 hour cessation of bleeding.

  • PDF

Normative blood pressure references for Korean children and adolescents (한국 소아 청소년 정상 혈압 참고치)

  • Lee, Chong Guk;Moon, Jin Soo;Choi, Joong-Myung;Nam, Chung Mo;Lee, Soon Young;Oh, Kyungwon;Kim, Young Taek
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.1
    • /
    • pp.33-41
    • /
    • 2008
  • Purpose : It is now understood that blood pressure (BP) measurement in the routine pediatric examination is very important because of the relevance of childhood BP to pediatric health care and the development of adult essential hypertension. There hasn't been a reference table of BP for Korean children and adolescents up to now. This study was to make normative BP references and to provide criteria of hypertension for Korean children and adolescents. Methods : BP measurements were done on 57,433 Koean children and adolescents (male: 29,443, female: 27,990), aged 7 to 20 years, in 2005. Heights and weights were measured simultaneously. Oscillometric devices, Dinamap Procare 200 (GE Inc., Milwaukee, Wi, USA), were used for the measurements. BPs were measured 2 times and mean levels were gathered for the analysis. Outliers of 2,373 subjects with overweight per height, over +3SD, were excluded for the analysis. For the BP centiles adjusted by sex, age and height, fixed modified LMS method which was adopted from the mixed effect model of 2004 Task Force in NHLBI (USA) was used. Results : Normative BP tables for Korean children and adolescents adjusted for height percentiles (5th, 10th, 25th, 50th, 75th, 90th, 95th), gender (male, female) and age(7 to 18 years) were completed. Height centiles of Korean children and adolescents are available from Korean Center for Disease Control and Prevention homepage, http://www.cdc.go.kr/webcdc/. Criteria of hypertension (95th, 99th percentile) and normal range of BP (50th, 90th) adjusted for height percentiles, age and gender were made. Conclusion : This is the first study to make normative BP tables and define hypertension for the Korean children and adolescents. Reliability and accuracy of Dinamap Procare 200 oscillometer for BP measurements remains debatable.

Effect of prophylactic indomethacin in extremely low birth weight infants (초극소 저출생체중아에서 예방적 indomethacin 투여효과)

  • Lee, Bo Lyun;Kim, Su Jin;Koo, Soo Hyun;Jeon, Ga Won;Chang, Yun Sil;Park, Won Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.9
    • /
    • pp.959-965
    • /
    • 2006
  • Purpose : The purpose of this study was to investigate the effect of prophylactic indomethacin on reduction of patent ductus arteriosus(PDA) and intraventricular hemorrhage(IVH) in extremely low birth weight infants(ELBWI). Methods : Retrospective review of 84 ELBWI who were admitted to our neonatal intensive care unit from June 2004 to April 2006 was performed. Patients were divided into prophylactic group(n=28) and control group(n=56), where prophylactic indomethacin were given within 6 hours after birth. Clinical outcomes were compared between these groups. Results : There were no significant differences in gestational age, birth weight, incidence of hemodynamically significant PDA and severe IVH, and mortality between prophylactic group and control group. However, there were more frequent indications for therapeutic indomethacin, higher incidence of intestinal perforation, and longer time to achieve full enteral feeding in prophylactic group than control group. The incidence of other adverse events attributed to indomethacin prophylaxis did not differ between two groups. Conclusions : Prophylactic indomethacin may not prevent hemodynamically significant PDA and severe IVH in ELBWI. On the contrary, it may be associated with increased risk of adverse events. Further efforts should be investigated to decrease PDA and severe IVH in ELBWI.

Effect of Beraprost Sodium in Patients with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환 환자에서 Beraprost sodium의 효과에 대한 연구: 이중 맹검 무작위 임상시험)

  • Lee, Sang-Do;Seo, Kwang Won;Lee, Jung Yeon;Huh, Jin Won;Choi, Ik Su;Park, Jae Sun;Shim, Tae Sun;Oh, Yeon-Mok;Park, In Won;Ryu, Wang-Seong;Choi, Byoung Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.4
    • /
    • pp.320-328
    • /
    • 2004
  • Background : Pulmonary vascular changes which occur early in the course of chronic obstructive pulmonary disease (COPD) are prevalent manifestation and later cause pulmonary hypertension, which is a bad prognostic factor in COPD. Beraprost sodium (BPS), an orally active prostacyclin analogue, has been shown to improve survival in patients with primary pulmonary hypertension. This study investigated the effect of BPS in the patients with COPD. Methods : This is a double-blind randomized placebo-controlled, two center clinical trial. Twenty one consecutive patients with COPD were enrolled from June 2003 to June 2004 (patients treated with BPS for 3 months, BPS group, n=11; those with placebo, placebo group, n=10). The baseline demographic, pulmonary function and hemodynamic data were not significantly different between two groups. Results : On echocardiographic examination, trans tricuspid valve pressure gradient has decreased significantly after 3 months with beraprost in the BPS group [17.7(${\pm}11.4$) to 8.2(${\pm}8.9$) mm Hg, p-value<0.05], while there was no significant change in the control group. Six-minute walking distance has decreased in the control group and increased in the BPS group, but there was no statistical significance. Conclusion : In patients with COPD oral administration of BPS reduced the pulmonary arterial pressure. The clinical significance of this finding, that is improving symptoms and natural course of the disease, needs further study.

Comparison of Beam Delivery Modes in Prostate Cancer Proton Therapy: A Treatment Planning Comparison Study (전립선암 환자 양성자치료 시 빔 전달방식에 따른 치료계획 비교)

  • Kim, Youn Young;Youm, Doo Seok;Jang, Yo Jong;Kang, Dong Yun;Park, Jeong Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.153-158
    • /
    • 2013
  • Purpose: After making two plans, the Double Scattering (DS) Mode and The Pencil Beam Scanning (PBS) Mode, of patients on early prostate cancer, we not only compare the dose conformity and the dose homogeneity by analyzing each DVH, CN and HI, but also evaluate normal structures's sparing effect on each mode. Materials and Methods: Planes about nine patients, who did proton therapy, on prostate cancer was setted using the Eclipse proton external beam planning system. The prescription dose, every $2.5 Gy{\times}28$ fractions=70 Gy, was delivered to the PTV. The CN and the HI were getted by anlazing each DVHs for the DS Plan and the PBS Plan. Also, normal structures' %volumes according to dose of the PBS are campared with those of the DS. Results: The average CN of the PTV is increase 16.63% from DS $0.68{\pm}0.07$ to PBS $0.79{\pm}0.01$, and the average IN of the PTV is decrease -22.66 % from DS $0.12{\pm}0.03$ to PBS $0.09{\pm}0.01$. The PBS has litter %Volumes of normal structures than the DS about every patient except Rectum. The average %Volume of Left Femoral Head receiving ${\geq}30$ Gy shows most high decreasing rate, -79.93%, from DS to PBS and the average %Volume of Rectum receiving ${\geq}70$ Gy shows most low decreasing rate, -3.03%, from DS to PBS. Conclusion: Therefore, the PBS is more effective achieving the dose conformity and the dose Homogeneity than DS, and better to reduce unnecessary dose arriving normal structures, especially the femoral heads.

  • PDF

A Studyof Psychiatric Treatment Compliance in Referred Patients at a General Hospital (자문의뢰된 입원환자의 특성과 정신과 치료 순응도에 대한 연구)

  • Shim, In-Bo;Ko, Young-Hoon;Lee, Moon-Soo;Kim, Yong-Ku;Han, Chang-Su
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.19 no.2
    • /
    • pp.66-73
    • /
    • 2011
  • Objectives:The present study investigates the status of inpatient psychiatric consultations at a general hospital in order to find factors that contribute to treatment compliance related to psychiatric consultations. Methods:The subjects were 333 patients who were hospitalized at Korea University Medical Center Ansan Hospital from 1 September 2009 to 31 July 2010.The patients were referred for psychiatric consultation during hospitalization. This study investigates demographic data, request department, referral causes, requestor, psychiatric history and diagnosis, andpsychiatric treatment compliance. Treatment compliance was defined as whether or not the patient had accepted psychiatric treatment during hospitalization or outpatient department(OPD) follow-up. This study ascertains the factors that have impact on compliance, by taking binary logistic regression with compliance and other variables. Results:Among the patients that were offered psychiatric treatment during hospitalization(N=310), treatment compliance was 82.9%. Among the patients that were offered OPD treatment(N=111), compliance was 55.8%. Elderly group(>65 years) showed better compliance to treatment during hospitalization than the younger patient group(OR=4.838, p=0.004). Patients with secondary psychiatric disorders showed better OPD follow-up compliance than patients with secondary psychiatric disorders(OR=8.520, p=.008). Conclusion:Elderly patients showed better compliance for psychiatric treatment during hospitalization. However they commonly have disorders such as delirium and mood disorders that have impact on the patient's physical state, hence further active measures should be carried out. Patients referred due to primary psychiatric disorders showed poor OPD compliance. Therefore clinicians have to suggest multidisciplinary interventions that will improve treatment compliance of such patients.

  • PDF

Diagnostic Efficacy of Anorectal Manometry for the Diagnosis of Hirschsprung's Disease (Hirschsprung병에서 항문직장 내압검사의 진단적 유용성)

  • Chang, Soo-Hee;Min, Uoo-Gyung;Choi, Ok-Ja;Kim, Dae-Yeon;Kim, Seong-Chul;Yu, Chang-Sik;Kim, Jin-Cheon;Kim, In-Koo;Yoon, Jong-Hyun;Kim, Kyung-Mo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.6 no.1
    • /
    • pp.24-31
    • /
    • 2003
  • Purpose: As diagnostic tools for Hirschsprung's disease (HD), barium enema and rectal biopsy have radiation exposure and invasiveness respectively; however anorectal manometry does not have these disadvantages. We therefore performed this study to evaluate the diagnostic efficacy of anorectal manometry. Methods: We reviewed medical records of infants with one or two symptoms of vomiting, abdominal distension, chronic diarrhea or constipation who had a anorectal manometry followed by barium enema and/or biopsy from July 1995 to May 2002. We evaluated the sensitivity, specificity and predictive value of anorectal manometry and barium enema for diagnosis of HD. We also measured sphincter length, median value of balloon volume at which rectoanal inhibitory reflex (RAIR) occurred. Results: All 61 patients received anorectal manometry, 33 of 61 received barium enema. 18 of 61 were diagnosed as HD according to histology and 43 of 61 were evaluated as a control. The sensitivity, specificity, positive predictive value, negative predictive value of anorectal manometry and barium enema for diagnosis of HD were 1.00, 0.91, 0.82, 1.00 and 0.93, 0.67, 0.70, 0.92 respectively. The mean value of sphincter length in control was $1.68{\pm}0.67$ cm and correlated with age, weight and significantly longitudinal length. The median value of balloon volume at which RAIR occurred was 10 mL and did not correlated with age, weight and longitudinal length. Conclusion: This study suggests that anorectal manometry is an excellent initial screening test for Hirschsprung's disease because of its safety and accuracy.

  • PDF