• Title/Summary/Keyword: 방법론 평가

Search Result 3,687, Processing Time 0.043 seconds

Protective Effects of 5-Androstendiol (5-AED) on Radiation-induced Intestinal Injury (방사선에 의한 장점막 손상에 대한 5-Androstenediol의 보호효과)

  • Kim, Joong-Sun;Lee, Seung-Sook;Jang, Won-Suk;Lee, Sun-Joo;Park, Sun-Hoo;Cho, Soo-Youn;Moon, Chang-Jong;Kim, Sung-Ho;Kim, Mi-Sook
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.141-146
    • /
    • 2010
  • Purpose: We examined the radioprotective effects of 5-androstendiol (5-AED), a natural hormone produced in the reticularis of the adrenal cortex, as a result of intestinal damage in gamma-irradiated C3H/HeN mice. Materials and Methods: Thirty mice (C3H/HeN) were divided into three groups; 1) non-irradiated control group, 2) irradiated group, and 3) 5-AED-treated group prior to irradiation. Next, 5-AED (50 mg/kg per body weight) was subcutaneously injected 24 hours before irradiation. The mice were whole-body irradiated with 10 Gy for the histological examination of jejunal crypt survival and the determination of the villus morphology including crypt depth, crypt size, number of villi, villus height, and length of basal lamina, as well as 5 Gy for the detection of apoptosis. Results: The 5-AED pre-treated group significantly increased the survival of the jejunal crypt, compared to irradiation controls (p<0.05 vs. irradiation controls at 3.5 days after 10 Gy). The evaluation of morphological changes revealed that the administration of 5-AED reduced the radiation-induced intestinal damages such as villus shortening and increased length of the basal lamina of enterocytes (p<0.05 vs irradiation controls on 3.5 day after 10 Gy, respectively). The administration of 5-AED decreased the radiation-induced apoptosis in the intestinal crypt, with no significant difference between the vehicle and 5-AED at 12 hours after 5 Gy. Conclusion: The results of this study suggest that the administration of 5-AED has a protective effect on intestinal damage induced by $\gamma$-irradiation. In turn, these results suggest that 5-AED could be a useful candidate for radioprotection against intestinal mucosal injury following irradiation.

Difference in the Set-up Margin between 2D Conventional and 3D CT Based Planning in Patients with Early Breast Cancer (조기유방암환자의 이차원치료계획과 삼차원치료계획의 방사선조사범위의 차이)

  • Jo, Sun-Mi;Chun, Mi-Son;Kim, Mi-Hwa;Oh, Young-Taek;Kang, Seung-Hee;Noh, O-Kyu
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.177-183
    • /
    • 2010
  • Purpose: Simulation using computed tomography (CT) is now widely available for radiation treatment planning for breast cancer. It is an important tool to help define the tumor target and normal tissue based on anatomical features of an individual patient. In Korea, most patients have small sized breasts and the purpose of this study was to review the margin of treatment field between conventional two-dimensional (2D) planning and CT based three-dimensional (3D) planning in patients with small breasts. Materials and Methods: Twenty-five consecutive patients with early breast cancer undergoing breast conservation therapy were selected. All patients underwent 3D CT based planning with a conventional breast tangential field design. In 2D planning, the treatment field margins were determined by palpation of the breast parenchyma (In general, the superior: base of the clavicle, medial: midline, lateral: mid - axillary line, and inferior margin: 2 m below the inframammary fold). In 3D planning, the clinical target volume (CTV) ought to comprise all glandular breast tissue, and the PTV was obtained by adding a 3D margin of 1 cm around the CTV except in the skin direction. The difference in the treatment field margin and equivalent field size between 2D and 3D planning were evaluated. The association between radiation field margins and factors such as body mass index, menopause status, and bra size was determined. Lung volume and heart volume were examined on the basis of the prescribed breast radiation dose and 3D dose distribution. Results: The margins of the treatment field were smaller in the 3D planning except for two patients. The superior margin was especially variable (average, 2.5 cm; range, -2.5 to 4.5 cm; SD, 1.85). The margin of these targets did not vary equally across BMI class, menopause status, or bra size. The average irradiated lung volume was significantly lower for 3D planning. The average irradiated heart volume did not decrease significantly. Conclusion: The use of 3D CT based planning reduced the radiation field in early breast cancer patients with small breasts in relation to conventional planning. Though a coherent definition of the breast is needed, CT-based planning generated the better plan in terms of reducing the irradiation volume of normal tissue. Moreover it was possible that 3D CT based planning showed better CTV coverage including postoperative change.

Analysis of Postnatal Acquisition Factors of the Normal Flora in Infants with Urinary Tract Infection (영아 요로감염에서 정상 세균총의 생후 획득 요인에 관한 분석)

  • Shim, Yoon-Hee;Kim, Hee-Jung;Lee, Seung-Joo
    • Childhood Kidney Diseases
    • /
    • v.11 no.2
    • /
    • pp.195-202
    • /
    • 2007
  • Purpose : The normal flora, which was suggested to prevent infection, is acquired first from the birth canal and develops by dietary factors. Here presents a case-control study, aimed to evaluate the postnatal acquisition factors relating to the achievement of the normal flora in infants with urinary tract infection (UTI). Methods : 115 UTI infants, admitted at Ewha Womans University Mokdong Hospital from 2004 to 2005 and 116 age-matched control infants, who had visited well baby clinic, were evaluated. The suggested postnatal acquisition factors of the normal flora such as vaginal delivery, breast feeding, probiotics and yogurt intake and their relationship with UTI were evaluated. Results : The rate of vaginal delivery was 50%(58/l15) in UTI infants, which was not significantly different from 60%(69/116) in control infants(P>0.05). In the infants with UTI, the feeding pattern(breast milk 19%, mixed 26%, formula 55%) was significantly different from that(44%, 19%, 37%) in control infants(P<0.05). This significant difference was shown only in infants less than 6 months of age, but was not in infants over 6 months of age. The rate of probiotics intake in UTI infants was 4%(4/115), which was significantly lower than 27% (32/116) in control infants(P<0.05). The rate of regular intake of yogurt in UTI infants over 6 months of age was 27%(6/23), which was not significantly different from 35%(8/23) in control infants(P>0.05). The odds ratios of breast feeding and probiotics intake against UTI were significantly low as 0.30 (95% Cl 0.17-0.55)(P<0.01) and 0.03 (95% Cl 0.01-0.07)(P<0.01). Conclusion : The significantly lower rates of breast feeding and probiotics intake in UTI infants suggest that these dietary factors might have preventive effects in infants with UTI.

  • PDF

Tuberculin Reactivity in Neonates Vaccinated with BCG at Primary Care Clinics - With Two Types of BCG Vaccine and Two Strengths of PPD - (개원가의 신생아 BCG 접종 후 투베르쿨린 반응 평가 -접종 방법과 PPD 종류에 의한 차이 비교-)

  • Kim, Wan Ju;Lee, Sun Ho;Ahn, Sang Yoon;Yang, Seung Jae;Oh, Sung Hee
    • Pediatric Infection and Vaccine
    • /
    • v.9 no.2
    • /
    • pp.208-214
    • /
    • 2002
  • Purpose : The number of newborns vaccinated with BCG of Tokyo 172 strain, which has been claimed to cause lesser degree of local adverse events including scar, has recently been increasing. However, tuberculin response to this vaccine has inadequately been studied, especially with newborns cared at primary care clinics. We, therefore, performed a study in newborns vaccinated with BCG at private pediatric offices and evaluated the response to PPD 2TU or PPD 5TU following vaccination with percutaneous or intradermal BCG. Methods : Two hundred infants who had been cared at three private pediatric offices were retrospectively enrolled in the study. One hundred fifty one infants had received percutaneous BCG(Tokyo strain); 129 infants had had tuberuclin test with PPD 2TU and the rest of 22 infants with PPD 5TU. Forty nine infants had received intradermal BCG(28 infants Copenhagen strain, I infant French strain, 20 infants unknown); 35 infants had had tuberculin test with PPD 2TU, 14 infants(11%) with PPD 5TU. Results : In infants vaccinated with percutaneous BCG, the mean induration diameter in tuberculin test was significantly greater with PPD 5TU($12.4{\pm}3.5mm$) compared to PPD 2TU ($9.2{\pm}4.4mm$). In infants vaccinated with intradermal BCG, the mean induration diameters in tuberculin test were $5.7{\pm}5.1mm$ to PPD 2TU and $6.6{\pm}4.8mm$ to PPD 5TU, which were not significantly different. The tuberculin response to PPD 2TU was significantly greater in infants vaccinated with percutaneous BCG compared to those with intradermal BCG. The tuberculin response to PPD 5TU was also significantly greater in infants vaccinated with percutaneous BCG compared to those with intradermal BCG. Conclusion : Percutaneous BCG(Tokyo strain) seems to cause greater response to tuberculin compared to intradermal BCG and PPD 2TU induces weaker response compared to PPD 5TU. Acknowledging some discrepancies from the previously reported data, which might have been due to the different source of the study subjects, more studies are needed to establish the range of tuberculin response following BCG vaccination in order to differentiate from tuberculosis.

  • PDF

The Evaluation of Radiation Therapy and Combined-modality Therapy for Non-small-cell Lung Cancer in Elderly (고령의 비소세포성폐암 환자의 방사선 및 병용치료에 대한 효과 평가)

  • Yoon, Won-Sup;Yang, Dae-Sik;Kim, Chul-Yong
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.101-108
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: To compare radiation therapy alone to combined modality therapy about survival rate and tolerance of elderly patients ($70=or{\geq}$) with non-small-cell lung cancer (NSCLC). $\underline{Materials\;and\;Methods}$: Between 1998 and 2002, 57 patients given radiation therapy due to NSCLC (Stage III) were analysed retrospectively. Radiation therapy alone (RT), concurrent chemoradiation (CRT), and sequential chemoradiation (SCRT) was done to 33, 16 and 8 patients, respectively. Patients' median age was 74 (range $70{\sim}85$). Male and female are 51 patients and 6 patients, respectively. 23 patients were stage IIIa and 34 were stage IIIb. Patients' characteristic distribution of RT and CRT was not significantly different except mass size that RT has a bigger than CRT. The fraction size of radiation therapy was 1.8 Gy in CRT and $1.8{\sim}3\;Gy$ in other groups. Total radiation dose was $51{\sim}63\;Gy$ according to the fraction size. If the prescribed total radiation dose was successfully irradiated, we stated that it was completion of radiation therapy. $\underline{Results}$: 52 patients were dead. Median period of radiation therapy was as follow: RT, 35 days, CRT, 60.5 days and SCRT, 35 days. Overall median survival time (MST) was 10.1 months. The 1 yr- and 2 yr-overall survival rate was 39.8% and 17.6%, respectively. MST of RT, CRT and SCRT was 8.9, 8.2 and 11.7 months, respectively. The 1 yr survival rate of RT, CRT and SCRT was 38.4%, 37.5% and 50% (not significant). Patients given incomplete radiation therapy were 12 (RT, 5 CRT, 6 SCRT, 1). N stage (p=0.081) and the difference of treatment methods (p=0.079) were the factors affecting incompletion of radiation therapy, but it was not significant. In case of combined-agents chemotherapy, 4 of 8 ceased radiation therapy. T stage ($T{\geq}3$), mass size (${\geq}5\;cm$), Karnofsky performance scale (${\leq}70$) and completion of radiation therapy were the prognostic factors in uni- and multi-variate analysis. $\underline{Conclusion}$: In elderly patients with NSCLC, radiation therapy alone was a treatment method with similar survival period compared with other methods. Generally, patients given radiation therapy alone was tolerable to a treatment. Before planning concurrent chemoirradiation in elderly patients with NSCLC, physicians pay attention to a selection of patients and chemotherapy agents considering general condition and toxicity.

The Development of Quality Assurance Program for CyberKnife (사이버나이프의 품질관리 절차서 개발)

  • Jang, Ji-Sun;Kang, Young-Nam;Shin, Dong-Oh;Kim, Moon-Chan;Yoon, Sei-Chul;Choi, Ihl-Bohng;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Kwon, Soo-Il;Lee, Dong-Han
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.185-191
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: Standardization quality assurance (QA) program of CyberKnife for suitable circumstances in Korea has not been established. In this research, we investigated the development of QA program for CyberKnife and evaluation of the feasibility under applications. $\underline{Materials\;and\;Methods}$: Considering the feature of constitution for systems and the therapeutic methodology of CyberKnife, the list of quality control (QC) was established and divided dependent on the each period of operations. And then all these developed QC lists were categorized into three groups such as basic QC, delivery specific QC, and patient specific QC based on the each purpose of QA. In order to verify the validity of the established QA program, this QC lists was applied to two CyberKnife centers. The acceptable tolerance was based on the undertaking inspection list from the CyberKnife manufacturer and the QC results during last three years of two CyberKnife centers in Korea. The acquired measurement results were evaluated for the analysis of the current QA status and the verification of the propriety for the developed QA program. $\underline{Results}$: The current QA status of two CyberKnife centers was evaluated from the accuracy of all measurements in relation with application of the established QA program. Each measurement result was verified having a good agreement within the acceptable tolerance limit of the developed QA program. $\underline{Conclusion}$: It is considered that the developed QA program in this research could be established the standardization of QC methods for CyberKnife and confirmed the accuracy and stability for the image-guided stereotactic radiotherapy.

Study on Vaccination State in Children : Jeonbuk Province, 2000 (전라북도 아동의 예방접종실태에 관한 조사연구)

  • Choung, Ju Mi;Kim, Jung Chul;Eun, So Hee;Hwang, Pyoung Han;Nyhambat, B.;Kilgore, P.;Kim, Jung Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.10
    • /
    • pp.1234-1240
    • /
    • 2002
  • Purpose : This study was carried out to obtain the vaccination rate and age appropriateness of vaccination in children under five years of age in Jeonbuk province. Methods : Eight hundred and fifty infants and children were enrolled in this study. Vaccination rate(Number of vaccinees/Number of subjects), places of vaccination, age appropriateness of vacination were examined by either vaccine record review or interview with parents or guardians. Results : The salient features of the findings were as follows : All subjects were aged under five and mostly under two years of age(68.8%). Places of vaccination were health centers or subcenters( 50.4%), private clinics(44.3%), and general hospitals(5.3%). Routine vaccinations such as BCG, hepatitis B vaccine(HBV), diphtheria, tetanus, acellular pertussis(DTaP) and Trivalent Oral Polio Vaccine(TOPV), measles, mumps, rubella(MMR), and Japaneses B encephalitis(JBE) were vaccinated mostly in health centers or subcenters, while chickenpox(CHP) and haemophilus influenzae vaccines(Hib), which are not routine in Korea, were vaccinated in private clinics. The vaccination rates of BCG(99.2%), HBV(93.5%) and DTaP(96.1%) were very high. But those of MMR(83.7%), CHP(72.5%), JBE(50.2%), and Hib(15.8%) were lower than expected. Considering the age appropriateness of vaccination, some infants and children were not appropriately vaccinated(vaccination rate/age appropriateness of vaccine; HBV, 93.5%/88.4% : DTaP, 94.6%/73.1% : JBE, 50.2%/ 18.5%). Conclusion : The vaccination rate of BCG, HBV, DTaP and TOPV was very high, but MMR, CHP, JBE, and Hib vaccination rate was not high enough to be able to protect against epidemic. We should pay more attention to vaccinating children, and there is a need for a program that will enhance coverage for vaccines.

Analysis of the major factors of influence on the conditions of the Intensity Modulated Radiation Therapy planning optimization in Head and Neck (두경부 세기견조방사선치료계획 최적화 조건에서 주요 인자들의 영향 분석)

  • Kim, Dae Sup;Lee, Woo Seok;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.11-19
    • /
    • 2014
  • Purpose : To derive the most appropriate factors by considering the effects of the major factors when applied to the optimization algorithm, thereby aiding the effective designing of a ideal treatment plan. Materials and Methods : The eclipse treatment planning system(Eclipse 10.0, Varian, USA) was used in this study. The PBC (Pencil Beam Convolution) algorithm was used for dose calculation, and the DVO (Dose Volume Optimizer 10.0.28) Optimization algorithm was used for intensity modulated radiation therapy. The experimental group consists of patients receiving intensity modulated radiation therapy for the head and neck cancer and dose prescription to two planned target volume was 2.2 Gy and 2.0 Gy simultaneously. Treatment plan was done with inverse dose calculation methods utilizing 6 MV beam and 7 fields. The optimal algorithm parameter of the established plan was selected based on volume dose-priority(Constrain), dose fluence smooth value and the impact of the treatment plan was analyzed according to the variation of each factors. Volume dose-priority determines the reference conditions and the optimization process was carried out under the condition using same ratio, but different absolute values. We evaluated the surrounding normal organs of treatment volume according to the changing conditions of the absolute values of the volume dose-priority. Dose fluence smooth value was applied by simply changing the reference conditions (absolute value) and by changing the related volume dose-priority. The treatment plan was evaluated using Conformal Index, Paddick's Conformal Index, Homogeneity Index and the average dose of each organs. Results : When the volume dose-priority values were directly proportioned by changing the absolute values, the CI values were found to be different. However PCI was $1.299{\pm}0.006$ and HI was $1.095{\pm}0.004$ while D5%/D95% was $1.090{\pm}1.011$. The impact on the prescribed dose were similar. The average dose of parotid gland decreased to 67.4, 50.3, 51.2, 47.1 Gy when the absolute values of the volume dose-priority increased by 40,60,70,90. When the dose smooth strength from each treatment plan was increased, PCI value increased to $1.338{\pm}0.006$. Conclusion : The optimization algorithm was more influenced by the ratio of each condition than the absolute value of volume dose-priority. If the same ratio was maintained, similar treatment plan was established even if the absolute values were different. Volume dose-priority of the treatment volume should be more than 50% of the normal organ volume dose-priority in order to achieve a successful treatment plan. Dose fluence smooth value should increase or decrease proportional to the volume dose-priority. Volume dose-priority is not enough to satisfy the conditions when the absolute value are applied solely.

Usefulness evaluation of Hybrid planning through dosimetric comparision of Three Dimensinal Conformal Radiation Radiotherapy and Hybrid planning for left breast cancer (유방암 환자의 방사선 치료시 Energy와 Wedge를 combine한 Hybrid plan의 유용성 평가)

  • Chae, Moon Ki;Park, Byung Soo;Ahn, Jong Ho;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.91-98
    • /
    • 2014
  • Purpose : To compare the dosimetry for the left breast cancer treatment between three dimensional conformal radiation radiotherapy (3D-CRT) and Hybrid planning and to estimate usefulness of Hybrid planning Materials and Methods : Five patients with left breast cancer were included in the study. They were planned using several different radiotherapy techniques including: 1)open rectangular field, 2)tangential wedge-based field 3)field in field, 4)hybrid planning(energy, wedge combine). For each patient planning was using Light Speed RT-16 CT and PINNACLE planning system-ver.9.2. Hybrid plan was made using same system and using the same targets and optimization goals. We comparing the Homogeneity Index(HI), normal organs at the does-volume histogram(DVH) Results : In all plans, the Homogeneity Index(HI) of Hybrid planning was significantly better than other. Dose comparison of HI= 2D-RT:38.32, TW:38.32, FIF:29.22, HYBRID:30.57. 2D-RT, TW, FIF Hybrid$V_{75_-lung}$=112.33, 125.14, 121.3, 123.78. $V_{50_-lung}$=155.43, 159.62, 157.96, 159.06. $V_{25_-lung}$=199.86, 200.22, 198.65, 200.31. $V_{50_-heart}$=26.07, 27.1, 26.85, 27.17 $V_{30_-heart}$=33.71, 34.37, 34.15, 34.65 Conclusion : In summary, 3D-CRT, Hybrid planning techniques were found to have acceptableCTV coverage in our study. However the Hybrid planning increased radiation dose exposure to normal tissue. If you apply for treatment of inhomogeneity areas like lung, For best results will be achieved.

Characteristics of Physiological Variables(EDR, EMG) in Biofeedback Treatment (바이오피이드백 치료에서 나타나는 신체변수(EDR, EMG)의 특성)

  • Seo, Man-Kil;Han, Woo-Sang;Lee, Kyung-Kyu;Yu, Bum-Hee;Lee, Yu-Ri;Kim, E-Yong;Kim, Hyun-Woo
    • Sleep Medicine and Psychophysiology
    • /
    • v.6 no.1
    • /
    • pp.38-45
    • /
    • 1999
  • Objectives: We explored the characteristics of physiological variables such as electrodermal response(EDR) and electromyography(EMG) in patients with insomnia, panic disorder, and other anxiety disorders. we aimed to decide the minimum sessions in biofeedback treatment to make the treatment effective and examine the effects of long-term biofeedback treatment by measuring the physiological variables. Methods: Thirty seven outpatients who received biofeedback treatment were divided into 3 groups according to the number of biofeedback sessions(patients who received 4-5 sessions, who received 6-9 sessions, and who received more than 10 sessions). We measured mean and delta values of EDR and EMG levels, and the Hamilton Anxiety Rating Scale(HARS), and Slef-Relaxation Inventory(SRI) in all patients. Data were analyzed by t-test and repeated measures analysis of variance. Results: The mean and delta values of EDR and EMG levels were not different among the 3 groups during the first 4 biofeedback sessions. However, patients who received more than 10 biofeedback sessions had higher baseline mean EDR value(F=2.233, p=0.036) in the first session, compared with other patients. In patients who received more than 10 biofeedback sessions, mean EDR was significantly reduced after $5^{th}$ session(F=10.41, p<0.01). They showed significant improvement in SRI scores at 12th biofeedback session(t=2.726, p<0.05) and in HARS scores at $6^{th}$(t=3.10, p<0.05) and $12^{th}$ biofeedback session(t=10.93, p<0.001). Conclusions: Wesuggest that patients should receive more than 5 biofeedback sessions to experience internal cues and get a good clinical response to biofeedback treatment.

  • PDF