• Title/Summary/Keyword: 방류수 수질기준

Search Result 115, Processing Time 0.026 seconds

Water Quality Prediction Model in a Lake by Finite Element Method;Application to Sapkyo Lake (유한요소법에 의한 호소의 수질예측모형;삽교 담수호에 적용하여)

  • Ryu, Byong-Ro;Ahn, Sang-Jin
    • Korean Journal of Environmental Agriculture
    • /
    • v.8 no.1
    • /
    • pp.37-46
    • /
    • 1989
  • A 2-dimensional pollutant transport phenomenon in shallow reservoirs was analyzed by using a finite element method. The Galerkin's weighted residual method, based on linear interpolation, was used and a triangle was adopted as an element. The two dimensional Stock's equation and the advection-diffusion equation integrated over depth were used as governing equations. Also the Newton-Raphson method was introduced to solve the non-linear terms of the equation. The results calculated by the model are in good agreement with the analytical solution for a simplified channel where a known solution is avaiable. An actual application of the model is attempted for Sapkyo Lake with a consideration of the influx of the Sapkyo Chun, the Muhan Chun and kogkyo Chun. Further refined research is needed to evaluate the water quality in the other reservoirs.

  • PDF

Characteristics of Ocean Environment around Outfall Discharged from Treatment Plant (하수종말 처리장 방류구 주변해역에서의 해양환경 특성에 관한 연구)

  • Cho, Chon-Rae;Cho, Hyeon-Seo;Lee, Dae-In;Park, Jeong-Chae
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.271-275
    • /
    • 2006
  • 여수 하수처리장 하수처리 방류수가 배출구 인근해역에 미칠 수 있는 영향정도를 파악하기 위하여 해양수질 및 저질 환경을 조사하였다. 조사는 총 30개 지점에서 수질과 저질의 일반항목과 영양염류에 대하여 실시하였다. 조사시기는 2005년 9월 3일 (하계), 2005년 11월 20일(추계), 2006년 2월 13일 (동계), 2006년 5월 28일 (춘계) 에 4 계절에 걸쳐 밀물시와 썰물시에 현장 조사를 실시하였다. 배출수는 해양수질환경의 특성을 통해 추정한 결과 직접영향권은 0.5km, 간접 영향권은 반경 약 2km까지로 추정되었다. 저질의 결과를 보면 산 휘발성 황화물의 농도가 많은 해역에서 저질의 오염기준을 초과하는 동 오염된 저질의 특성을 보였으며, 산 휘발성 황화물과 화학적 산소요구량의 분포는 니질 퇴적상이 두드러지게 나타나는 배출구 동측과 돌산도 남동쪽, 돌산도 서측과 대경도 동측사이에 위치한 해역에서는 대체적으로 높은 값들을 보이고 있으며, 조립질 퇴적상이 주로 분포하고 있는 배출구와 국동항사이의 수로에서는 대체적으로 낮은 분포를 나타내었다.

  • PDF

Development and Validation of Multiple Regression Models for the Prediction of Effluent Concentration in a Sewage Treatment Process (하수처리장 방류수 수질예측을 위한 다중회귀분석 모델 개발 및 검증)

  • Min, Sang-Yun;Lee, Seung-Pil;Kim, Jin-Sik;Park, Jong-Un;Kim, Man-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.312-315
    • /
    • 2012
  • In this study, the model which can predict the quality of effluent has been implemented through multiple regression analysis to use operation data of a sewage treatment plant, to which a media process is applied. Multiple regression analysis were carried out by cases according to variable selection method, removal of outliers and log transformation of variables, with using data of one year of 2011. By reviewing the results of predictable models, the accuracy of prediction for $COD_{Mn}$ of treated water of secondary clarifiers was over 0.87 and for T-N was over 0.81. Using this model, it is expected to set the range of operating conditions that do not exceed the standards of effluent quality. In conclusion, the proper guidance on the effluent quality and energy costs within the operating range is expected to be provided to operators.

The Application of the Sewage, Sanitary Sewage and Wastewater Processing by Soil Purification Theory (토양정화법을 이용한 하.오수 및 폐수 처리의 현장적용성에 관한 연구)

  • Chun, Byungsik;Yoo, Junhee;Kim, Jungyong;Kumar, S;Shin, Sanguok;Shin, Bangwoong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.4
    • /
    • pp.77-84
    • /
    • 2008
  • Soil purification theory is the method using the soil micro-organism like aerobic and anaerobic for treatment of wastewater. The soil has many kinds of micro-organism and it multiply as change of the environment. Unlikely other methods, the soil purification theory is adaptable to inflow water change; moreover, it can process the T-N, T-P without any special method and management. The top is covered with the improved soil which can remove the bad smell and is used for resting place according to planting the lawn. This study is focused on analysis of the treatment processing of wastewater comparing inflow with outflow water. As a results, removal rate of the processing the BOD, COD and SS is almost 90~100% and it is 60~80% in T-N, T-P.

  • PDF

Feasibility Study of Wetland-pond Systems for Water Quality Improvement and Agricultural Reuse (습지-연못 연계시스템에 의한 수질개선과 농업적 재이용 타당성 분석)

  • Jang, Jae-Ho;Jung, Kwang-Wook;Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.3 s.108
    • /
    • pp.344-354
    • /
    • 2004
  • A pilot study was performed from September 2000 to April 2004 to examine the feasibility of the wetland-pond system for the agricultural reuse of reclaimed water. The wetland system was a subsurface flow type, with a hydraulic residence time of 3.5 days, and the subsequent pond was 8 $m^3$ in volume (2 m ${\times}$ 2 m ${\times}$ 2 m) and operated with intermittent-discharge and continuous flow types. The wetland system was effective in treating the sewage; median removal efficiencies of $BOD_5$ and TSS were above 70.0%, with mean effluent concentrations of 27.1 and 16.8 mg $L^{-1}$, respectively, for these constituents. However, they did often exceed the effluent water quality standards of 20 mg $L^{-1}$. Removal of T-N and T-P was relatively less effective and mean effluent concentrations were approximately 103.2 and 7.2 mg $L^{-1}$, respectively. The wetland system demonstrated high removal rate (92 ${\sim}$ 90%) of microorganisms, but effluent concentrations were in the range of 300 ${\sim}$ 16,000 MPN 100 $mL^{-1}$ which is still high for agricultural reuse. The subsequent pond system provided further treatment of the wetland effluent, and especially additional microorganisms removal in addition to wetland-pond system could reduce the mean concentration to 1,000 MPN 100 $mL^{-1}$ from about $10^5$ MPN 100 $mL^{-1}$ of wetland influent. Other parameters in the pond system showed seasonal variation, and the upper layer of the pond water column became remarkably clear immediately after ice melt. Overall, the wetland system was found to be adequate for treating sewage with stable removal efficiency, and the subsequent pond was effective for further polishing. This study concerned agricultural reuse of reclaimed water using natural systems. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, wetland- pond system was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water in rural area.

The Air-stripping Process Conjugated with the Ultrasonic Treatment to Remove TOC in Groundwater around the LPG Underground Storage Cavern (탈기법과 초음파 처리법을 연계한 LPG 지하공동저장소 주변 오염지하수 내 TOC 제거)

  • Han, Yikyeong;Jun, Seongchun;Kim, Danu;Jeon, Soyoung;Lee, Minhee
    • Economic and Environmental Geology
    • /
    • v.55 no.5
    • /
    • pp.511-519
    • /
    • 2022
  • In order to develop an air-stripping based remediation process to remove the TOC (Total Organic Carbon) in groundwater around the underground LPG storage cavern, the laboratory scale experiments at various conditions (change of air injection volume and temperature, the application of ultrasonic treatment, etc.) for two types of groundwater (initial TOC concentration of 608 mg/L and 153 mg/L, respectively). From results of experiment, as the air injection rate for stripping into groundwater increased from 2 L/min to 11 L/min and as the air-stripping time increased from 1 hour to 24 hour, the TOC removal efficiency of air-stripping increased. However, the TOC concentration of treated groundwater was higher than the discharge tolerance limit (100 mg/L) even after 24 hour stripping at the maximum air injection rate of 11 L/min. The main compounds of the TOC in groundwater were identified as methanol and propane and the long stripping time (more than 24 hour) was needed to separate the methanol from groundwater because of the affinity between water and methanol. At 20℃ and 4 L/min of air injection, the TOC removal efficiency increased to 59.1% after 24 hour air-stripping. When the temperature of groundwater increased to 30℃ and 40℃, the TOC removal efficiency increased up to 80.0% and 82.8%, suggesting that more than 24 hour air-stripping at 40℃ is needed to lower the TOC concentration to below 100 mg/L and the additional TOC removal process as well as the air-stripping is necessary. When the temperature increased to 60℃ and the ultrasonic treatment was conjugated with the air-stripping, the TOC removal efficiency increased to 87.8% within 5 hour stripping and the final TOC concentration (72.4 mg/L) was satisfied with the TOC discharge tolerance limit. The TOC removal efficiency for groundwater having low TOC concentration (153 mg/L) also showed similar removal efficiency of 89.7% (the final TOC concentration: 18.9 mg/L). Results in this study supported that the air-stripping conjugated with the ultrasonic treatment could remove successfully the TOC in groundwater around the underground LPG strorage cavern.

Study for biological denitrification of high strength nitrogen industrial wastewater (고농도 질소 함유 폐수의 생물학적 탈질에 관한 연구)

  • Han, Hyung-Suk;Won, Ki-Yeon;Song, Jin-Ho;Lee, Eun-Sil;Kim, Ho;Choi, Chang-Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.251-251
    • /
    • 2011
  • 해양 투기가 금지되면서 혐기소화를 통해 최종적으로 발생되는 폐기물 양을 줄이고 메탄 등의 바이오 가스를 얻어 이를 에너지로 얻기 위한 많은 공정들이 현장에 적용되고 있다. 하지만 혐기 소화 과정을 마친 후 유출되는 유출액은 고농도의 유기물질 및 암모니아성 질소, 인산염 등을 다량으로 함유하고 있어 적은 양이라도 하천이나 호수 등에 유입되면 수질 악화와 부영양화를 초래할 위험성이 크다. 이번 연구에서는 음식물류 폐기물로부터 바이오가스를 생산하기 위한 혐기소화 공정에서 발생하는 유출액의 방류수 수질기준 확보와 경제성을 만족시킬 수 있는 처리공정의 상용화 기술을 개발하기 위해 생물학적 처리, 물리 화학적 처리를 통합한 공정을 적용하였다. P건설사 혐기소화 유출액 pilot plant(1 ton/day) 운전 결과 50~70% 로 $NO_2$-N 이 약 1,000 mg/$\ell$정도로 축적되는 현상을 보였으며 상대적으로 $COD_{Cr}$의 농도는 400~600 mg/$\ell$로 C/N 비가 낮아 탈질이 어려울 것으로 판단하였다. 이에 실험실 규모에서의 실험을 진행하였다. $NO_2$-N와 $NO_3$-N을 기준으로 McCarty 양론비 기준 80% 에서 300%까지 메탄올을 주입해 제조 폐수와 실제폐수로 실험을 진행하였고 제조폐수로 실행된 실험에서 아질산 탈질의 효율을 확인하였다. 미생물이 메탄올에 순응 후 완전 탈질에 걸리는 시간은 약 2.5 일로 확인 되었으며 메탄올이 추가로 주입되지 않은 반응조의 $NO_2$-N의 탈질량은 메탄올이 이론값 100% 주입 된 반응조에 비해 30% 이하의 처리 효율을 나타냈다. 이론값을 기준으로 메탄올이 100% 주입된 반응조는 약 96.1%의 탈질 효율을 보였으며 메탄올 순응 후에 약 1.5 일의 HRT가 단축되었기 때문에 메탄올에 장시간 순응 시 탈질 효율이 더 좋아질 것으로 보인다. 아질산탈질에 대한 실험실 규모 연구결과를 토대로 pilot plant에서 재현성 검토를 목적으로 운전을 수행하였다. 무산소조의 HRT는 2.7 일 이었으며 호기조의 HRT는 4.1 일 이었다. 유입수의 평균 $COD_{Cr}$ 농도는 2,878 mg/L, T - N 농도는 2,723 mg/L로 나타났으며 $NO_2$-N 기준 C/N비 1.2-1.8의 메탄올을 주입하였을 때 96% 이상의 탈질율을 보였다.

  • PDF

Aquatic Plant Restortaion by Mattress/Filter System in Stagnant Stream Channel (정체수역에서의 Mattress/Filter에 의한 수생식물 복원)

  • Yeo Woon Ki;Cho Seung Ho;Jee Hong Kee;Lee SoonTak
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1393-1397
    • /
    • 2005
  • 홍수유출을 저감시키기 위해서 유역의 저류기능을 강화시킬 수 있는 댐 건설은 이수적인 측면에서 안정적인 용수공급을 보장해주는 수단으로 겸용되어 왔으며, 특히 다목적댐이 건설되면서 하도의 첨두홍수유출량을 줄이는데 크게 기여해 왔다. 하지만 그로 인해 물의 흐름이 막히는 정체수역이 증가하고 있으며, 생활오수, 산업폐수의 발생은 정체수역에서의 영양염류 부하량을 증가시켜 부영양화를 초래하고 있다. 수생식물은 태양빛을 받아 광합성 작용을 하여 수중에서 성장하면서 수중의 유$\cdot$무기물질을 영양소로 섭취함으로써 수질을 정화시키는 작용을 하게 된다. 영양염류 부하량이 큰 정체수역의 오염된 물은 식물의 성장활동에 의해서 어느 정도 정화시킬 수 있으며, 이와 같이 수중에 식물을 식재하기 위해서는 식물이 하상에 쉽게 그리고 지속적으로 성장하고 번식활동을 할 수 있는 여건이 필요하다. 따라서 본 연구에서는 Mattress/Filter를 정체수역에 설치함으로써 이러한 식물의 성장과 번식을 도와줄 수 있는 환경조건을 제안하였다. 연구결과, Mattress에 식재한 갈대, 줄 및 애기부들의 피도는 $60-80\%$ 정도로 나타났다. 각 Mattress의 식물군집에는 초기 식재한 식물의 우점도가 가장 높았으나 갈대와 줄 군락의 경우 다른 종이 많이 출현하는 것으로 나타났다. 갈대 군락에서는 갈대가 크게 우점하였으나 그 외에 돌피, 하늘지기, 여뀌바늘 등이 우점하는 것으로 나타났다. 또한 줄 군락에서는 역시 줄이 크게 우점하였으나 방동사니, 돌피, 조개풀 등이 출현하였다. 애기부들 군락에서는 애기부들외에 세모고랭이와 미국가막사리 두가지 종만 출현한 것으로 나타났다. 갈대와 줄 군락의 출현 종수는 각각 7과 11이었으며, 다양도지수가 1.67, 2.18로 식물다양성이 크게 증가한 것으로 나타났다. 수질은 BOD 10mg/L, TN 15mg/L, TP 2.0mg/L이하로 이를 유등천 상류부에 공급할 경우 유등천의 수질은 BOD 6.7mg/L, TN 9.80mg/L, TP 0.90mg/L를 나타낼 것으로 예측된다. 고도처리시설의 도입 후 금강 합류점에서 갑천의 예측 BOD는 7.4mg/L로 현재 9.0mg/L에 비하여 개선되지만 이는 금강수계 오염총량 관리계획의 시$\cdot$도 경계지점 목표수질인 5.9mg/L를 만족시키지 못하므로, 이를 만족시키기 위해서는 방류수 BOD 7.2mg/L이하로 처리해야 할 것으로 판단된다.which support only concepts or image features.방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.8R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10}{\times}0.797{\times}e^{-0.021s(\%)}$로 나타났다.천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조하여 적용할 필요가 있음을 시사하고

  • PDF

Study on the Improvement of Water Quality by the strengthening of T-P effluent standard for Environmental Facilities in Paldang Basin (환경기초시설의 인 기준 강화에 따른 팔당호 유입 수계의 수질개선 효과분석)

  • Jeong, Won-Gu;Han, Young-Han;Rim, Jay-Myung
    • Journal of Industrial Technology
    • /
    • v.30 no.B
    • /
    • pp.125-135
    • /
    • 2010
  • The influences on water quality of each river by effluents from environmental facilities $located^{*}$ in 14 unit watersheds of North- and South-Han River, and Gyungan-cheon were analyzed. Also, the water quality modeling for study area was carried out to analyze the improvement effect of water quality by the strengthening of T-P effluent standard of environmental facilities. For the calibration and verification of model, water quality data and effluent loading calculated for 2006 were used. Data of low water period were used for calibration, and normal water period for verification. The results of calibration and verification were well matched with the real water quality dataset of revers. Also, the validity of the results were estimated using RI (Reliability Index) method. When the T-P effluent standards for environmental facilities were strengthened, T-P concentrations were predicted to improve from $0.025mg/{\ell}$ to $0.023mg/{\ell}$ in the outlet location of North-Han River, from $0.056mg/{\ell}$ to $0.040mg/{\ell}$ for South-Han River,and from $0.233mg/{\ell}$ to $0.146mg/{\ell}$ for Gyungan-cheon. Also, the T-P concentrations of tributaries including Jojong-cheon, Dal-cheong, Sumgang, Chungmi-cheon, Bokha-cheon, Heuk-cheon, and Wonju-cheon were predicted to improve from $0.063mg/{\ell}$ to $0.010mg/{\ell}$, from $0.091mg/{\ell}$ to $0.053mg/{\ell}$, from $0.199mg/{\ell}$ to $0.100mg/{\ell}$, from $0.168mg/{\ell}$ to $0.148mg/{\ell}$, from $0.186mg/{\ell}$ to $0.105mg/{\ell}$, from $0.019mg/{\ell}$ to $0.013mg/{\ell}$, and from $0.822mg/{\ell}$ to $0.236mg/{\ell}$, respectively.

  • PDF

Comparison of Algal Growth Kinetics using Reclaimed Wastewaters from Various Treatment Processes (다양한 수질정화 공정 별 하수처리수 재이용수의 조류성장 비교)

  • Joo, Jin-Chul;Seo, Sou-Hyun;Song, Ho-Myeon;Kim, Il-Ho;Ahn, Chang-Hyuk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.309-309
    • /
    • 2011
  • 지구온난화와 도시기후 변화에 대응하기 위해 자연의 생태적 기능을 복원하고 환경에 대한 오염부하를 저감하여 도시 환경의 건강성과 지속성을 높이기 위해 도심 내 물순환시스템(urban water circulating system)의 구축이 요구된다. 즉, 물순환시스템을 활용하여 도심 내 다양한 수원(생태하천/호수 유지용수, 하수처리수, 우수, 지하수 등)을 네트워크 및 통합 관리하여 도시 내 물순환의 건전성과 수자원의 재이용률을 향상시킬 수 있다. 이를 위해서 연중 발생량이 일정하고 막대한(66.4억톤/년, 2009년 기준) 하수처리수 방류수는 고도처리를 통해 수질이 양호하며 안정적인 대체 수자원으로 고려된다. 또한, 하수처리수의 재이용은 공공수역으로 배출되는 오염부하량의 총량 삭감 및 상수사용량의 절감과 수자원을 효율적으로 이용한다는 면에서 최근 재이용 사례가 증가하고 있는 추세이다. 그러나, 도심 내 친수공간(생태하천/호수)은 저류수량에 비해 유입수량이 적어 체류시간이 비교적 장시간이고, 이로 인해 부영양화가 쉽게 발생해 수질이 악화된다. 따라서, 본 연구에서는 하수처리수 재이용수를 도심 내 친수공간의 유지용수로 활용 시, 수질정화공정(응집 후 여과, 응집 후 여과+한외여과, 응집 후 여과+한외여과+역삼투 공정)이 친수공간 내 조류성장에 미치는 영향을 파악하기 위해, 하수처리수 재이용수 pilot plant의 수질정화공정별 유출수를 활용해 M. aeruginosa를 시험조류로 조류성장(growth kinetics)을 조사하였다. 조류는 $5\times104$ cells/mL의 초기 농도로 접종하여 배양하였으며, 조류성장에 직접적인 제한인자인 용존반응성인의 농도에 따른 성장속도를 Monod와 변형 Monod Kinetics를 이용해 반포화상수(Ks)와 최대 성장속도(${\mu}$max)를 산정하였다. 실험결과, 역삼투 공정을 제외한 다른 수질정화공정은 비록 영양염류가 80~90% 이상 제거되어 수계의 화학적 성상이 변하였으나 조류성장역학의 변화는 통계학적 (p=0.05)으로 유의할만한 수준은 아닌 것으로 판명되었다. 또한, 수리학적 체류시간이 2주 이상이 될 경우, 역삼투 공정을 제외한 수질정화공정 별 유출수에서는 조류의 과다성장으로 인해 부영양화가 발생하는 것으로 판명되었다. 결론적으로 하수처리수 재이용수를 친수용수로 활용시, 조류성장을 방지하기 위하여 용존반응성인의 농도를 중점적으로 관리하는 수질정화공정 및 유지용수 공급방안을 고려해야하는 것으로 판단된다.

  • PDF