• Title/Summary/Keyword: 방류량 제어

Search Result 32, Processing Time 0.028 seconds

Application of deep learning method for decision making support of dam release operation (댐 방류 의사결정지원을 위한 딥러닝 기법의 적용성 평가)

  • Jung, Sungho;Le, Xuan Hien;Kim, Yeonsu;Choi, Hyungu;Lee, Giha
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.spc1
    • /
    • pp.1095-1105
    • /
    • 2021
  • The advancement of dam operation is further required due to the upcoming rainy season, typhoons, or torrential rains. Besides, physical models based on specific rules may sometimes have limitations in controlling the release discharge of dam due to inherent uncertainty and complex factors. This study aims to forecast the water level of the nearest station to the dam multi-timestep-ahead and evaluate the availability when it makes a decision for a release discharge of dam based on LSTM (Long Short-Term Memory) of deep learning. The LSTM model was trained and tested on eight data sets with a 1-hour temporal resolution, including primary data used in the dam operation and downstream water level station data about 13 years (2009~2021). The trained model forecasted the water level time series divided by the six lead times: 1, 3, 6, 9, 12, 18-hours, and compared and analyzed with the observed data. As a result, the prediction results of the 1-hour ahead exhibited the best performance for all cases with an average accuracy of MAE of 0.01m, RMSE of 0.015 m, and NSE of 0.99, respectively. In addition, as the lead time increases, the predictive performance of the model tends to decrease slightly. The model may similarly estimate and reliably predicts the temporal pattern of the observed water level. Thus, it is judged that the LSTM model could produce predictive data by extracting the characteristics of complex hydrological non-linear data and can be used to determine the amount of release discharge from the dam when simulating the operation of the dam.

Development of Han River Multi-Reservoir Operation Rules by Linear Tracking (선형추적에 의한 한강수계 복합 저수지 계통의 이수 조작기준 작성)

  • Yu, Ju-Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.6
    • /
    • pp.733-744
    • /
    • 2000
  • Due to the randomness of reservoir inflow and supply demand it is not easy to establish an optimal reservoir operation rule. However, the operation rule can be derived by the implicit stochastic optimization approach using synthetic inflow data with some demand satisfied. In this study the optimal reservoir operation which was reasonably formulated as Linear Tracking model for maximizing the hydro-energy of seven reservoirs system in the Han river was performed by use of the optimal control theory. Here the operation model made to satisfy the 2001st year demand in the capital area inputted the synthetic inflow data generated by multi-site Markov model. Based on the regressions and statistic analyses of the optimal operation results, monthly reservoir operation rules were developed with the seasonal probabilities of the reservoir stages. The comparatively larger dams which would have more controllability such as Hwacheon, Soyanggang, and Chungju had better regressions between the storages and outflows. The effectiveness of the rules was verified by the simulation during actually operating period.period.

  • PDF

A Study on Energy Saving Effect from Automatic Control of Air Flowrate and Estimation of Optimal DO Concentration in Oxic Reactor of Wastewater Treatment Plant (하수처리장의 포기조 최적 DO 농도 산정 및 공기송풍량 자동제어를 통한 에너지 절감 효과 도출)

  • Kim, Min Han;Ji, Seung Hee;Jang, Jung Hee
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.49-56
    • /
    • 2014
  • It is important to keep stable effluent water quality and minimize operation cost in biological wastewater treatment plant. However, the optimal operation is difficult because of the change of influent flow rate and concentrations, the nonlinear dynamics of microbiology growth rate and other environmental factors. Therefore, many wastewater treatment plants are operated for much more redundant oxygen or chemical dosing than the necessary. In this study, the optimal control scheme for dissolved oxygen (DO) is suggested to prevent over-aeration and the reduction of the electric cost in plant operation while maintaining the dissolved oxygen (DO) concentration for the metabolism of microorganisms in oxic reactor. For optimal control, The oxygen uptake rate (OUR) is realtime measured for the identification of influent characterization and the identification of microorganisms' oxygen requirement in oxic reactor. Optimal DO seT-Point needed for the microorganism is suggested based on real time measurement of oxygen uptake of microorganism and the control of air blower. Therefore, both stable effluent quality and minimization of electric cost are satisfied with a suggested optimal setpoint decision system by providing the necessary oxygen supply requirement to the microorganisms coping with the variations of influent loading.

Characteristics Evaluation of Non Point Source Treatment Facilities in Construction Site (건설 현장 내 비점오염원 처리 시설의 제거 특성 평가)

  • Choi, Younghoa;Jeong, Seolhwa;Kim, Changryong;Kim, Hyosang;Oh, Jihyun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.3
    • /
    • pp.53-62
    • /
    • 2009
  • This study was conducted to investigate characteristics of the non-point source pollution under construction and evaluate available pollution control methods. Suspended solid loading is high when soil disturbs by rainfall and this phenomenon is much more severe at the initial stage of construction than at the final one. There are three methods available for erosion and sediment control, which are check dam, silt fence, and geotextile. Check dam and silt fence are for control of suspense solids and geotextile is for preventing soil erosion during rainfall. They can be installed as temporary control facilities at construction sites. From the comparison of those methods, it was found that geotextile method was the most efficient for the runoff control of non-point source pollution. Check dam and silt fence can remove suspense solids by pore spaces to some degree, but the removal of pollutants mainly occurs through sedimentation. Because the temporary control facilities have limited removal efficiency of pollutant, they often cause civil claims and contamination of water environment. Hence, using a pressurized filtration system along with temporary control facilities, highly enhanced treatment efficiency was anticipated. In addition, the loading capacity of these techniques depends on filtration velocity and input loading. And their pre-treatments are necessary for efficient operation.

  • PDF

A Study for Storage Reallocation of Multipurpose Reservoir(I) - Flood Control Storage Analysis (다목적댐 용량 재할당에 대한 연구(I)- 치수용량 분석)

  • Yi, Jae-Eung;Kwon, Yong-Ik;Yoon, Young-Nam;Ahn, Tae-Jin
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.4
    • /
    • pp.273-281
    • /
    • 2004
  • Generally, reservoir storage is allocated according to planned purposes established before construction and operating policies are established through release control. The established reservoir allocation is hardly changed unless the special cases such as raising dam or changed purposes occur It Is, however, likely that public needs and objectives can be changed as time go on, the study for multipurpose reservoir storage reallocation is performed as an alternative to reflect these. In this study, flood control analysis is performed for several alternatives of reallocation for the Daechung multi-purpose reservoir in Geum river. As a result, it is confirmed that flood control capability is not decreased compared to single operation of Daechung reservoir for the same flood condition even if conservation level of Daechung multi-purpose reservoir is increased.

Application of the Proper Air Supply Amount Based on the Influent Water Quality for the Development of Efficient Blower Control Logic in Sewage Treatment Plants (하수처리장의 효율적인 Blower Control Logic 개발을 위한 유입수질 기반 공기공급량 적용 연구)

  • Yeo, Wooseok;Kim, Jong Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.493-499
    • /
    • 2022
  • The standards pertaining to the quality of discharged water in sewage treatment plants are strengthening, and accordingly, facilities in sewage treatment plants are being upgraded. In addition, the discharge water quality of sewage treatment plants must be maintained at a high level, and efficient sewage treatment plant operations have thus emerged as a very important issue. For the efficient operation of sewage treatment plants, this study applied a basic blowing amount calculation method based on sewage facilities to evaluate the required oxygen amount and blowing amount according to inflow water quality by logicizing various influencing factors. As a result of calculating the amount of air blown by applying actual April water quality data from sewage treatment plant A to the blower demand calculation developed through this study, it was found that the average amount of air blown was reduced by about 12%. When the blower demand calculation developed here is applied to an actual sewage treatment plant, the amount of air blown can be controlled based on the inflow water quality. This can facilitate the realization of an autonomous control of sewage treatment plants, in contrast to the existing sewage treatment operation method that relies on operational experience of operator. In addition, it is expected that efficient sewage treatment plants can be operated by reducing blowing amounts and power costs, which will contribute to both energy and carbon savings.

Flood Reducition Effect Analysis of Storage and Infiltration Facilities of Rainwater Drainage Efficiency improvement (빗물받이 효율 개선을 위한 저류-침투시설의 효과 분석)

  • Jong Pyo Park;Chang Yeon Won;Chang Sam Jeong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.68-68
    • /
    • 2023
  • 호우로 인한 도시 지역의 침수는 빗물받이의 능력 부족, 우수관로 용량 부족 등 다양한 요인에 의하여 발생한다. 구체적으로 빗물받이 능력 부족으로 인한 침수는 노면에 떨어진 우수가 빗물받이로 유입하지 못하고 지표면을 유하하여 저지대에 빗물이 모여 발생하게 되며 우수관로의 용량부족은 설계 강우 이상의 호우가 발생하거나 하류 배수위 영향으로 인하여 우수관로 내 만관이 발생하여 맨홀 월류로 인하여 침수가 발생하게 된다. 도시지역의 침수를 경감하기 위해서는 구조적, 비구조적인 대책을 마련할 수 있으며 본 연구에서는 국부적인 노면 침수가 발생하는 주요 도로 주변부의 침수발생을 효율적으로 제어하기 위한 구조적 대책 중 하나인 UHPC 저류침투시설 도입에 따른 홍수저감 효과를 수리수문학적 분석하는 방법을 개발하였다. 분석 절차는 ① 대상지역 현황 분석을 위한 관망도, 수치지형도, 토지피복도, 토양도 등 관련 자료의 조사 ② 침수 발생 현황 및 시설물 설치에 따른 효과분석을 위한 강우분석 ③ 주요 호우 시 대상지역 침수발생 현황 분석 ④ 저수지 홍수추적 기법을 활용한 저류침투시설 도입효과 계산 ⑤ 주요 호우별 홍수조절효과 분석결과를 기초로 저류침투시설 도입에 따른 침수 저감 효과를 2차원으로 검토의 5개 단계로 이루어진다. 노면을 따라서 유하 또는 맨홀 월류에 의해 저류 침투시설로 유입하는 우수의 홍수조절 효과 분석은 연구에서 개발한 스프레드시트 기반 저수지 홍수추적 기법을 활용하여 분석하였으며 강우-유출량 중 10 %가 시설물로 유입하는 가정 조건하에 시설물로 유입하는 우수의 저류-침투-방류를 동시에 고려하여 계산하였다. 다만, 저류침투시설로 유입하는 노면 유출수의 정량적 수치는 자연적 요인 및 다양한 제약 조건에 따라 큰 차이가 있을 수 있으며 불확실성이 높으므로 노면 유출수의 저류침투시설 유입량의 추가적인 연구가 필요하다.

  • PDF

Analysis of Flow and BOD Transport at the Downstream of Nam River Dam Using 2-D and 3-D Semi-coupled Models (2·3차원 준연계 모형을 이용한 남강댐 하류부 흐름 및 BOD 수송 해석)

  • Kim, Ji-Hoon;Song, Chang-Geun;Kim, Young-Do;Seo, Il-Won
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.3
    • /
    • pp.331-347
    • /
    • 2012
  • The downstream of the Nam River Dam is crucial region for long-term water resource planning for Busan and Gyeongnam Province. Thus, the analysis of flow behavior and water quality is necessary for the sustainable surface water management and the control of pollutant source. In this study, the flow field and BOD transport at the downstream of Nam River Dam were analyzed by incorporating 2-D water quality model, RAM4 and 3-D water quality model, WASP with the hydrodynamic model, RAM2 and EFDC, respectively. The application of 2-D flow analysis model, RAM2 showed that velocity distributions at the five transverse sections of the meandering part closely followed the measured values by ADCP, and the flow field and overflow characteristic at the submerged weir showed satisfactory performance compared with the result of 3-D EFDC model. In addition, the BOD concentration field obtained by RAM2-RAM4 coupled modeling was in good agreement with the result by EFDC-WASP model throughout the computational domain. The hydrodynamic characteristic and water quality at the downstream reach of Nam River Dam are mainly influenced by the Dam discharge, and the water quantity is closely related to the water quality control and fishery environment at the lower part of Nakdong River. Therefore, when further quantitative analysis is necessary regarding these issues, 2-D semi-coupled modeling is recommended in terms of computational effectiveness and model application aspect.

Analysis of the adsorption of cationic guar gum on the cellulose in the closed papermaking system (폐쇄화된 초지공정에서의 양이온성 구아 검의 흡착 평가)

  • 이학래;이지영;신종호
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2001.11a
    • /
    • pp.43-43
    • /
    • 2001
  • 원료의 저급화와 공정의 폐쇄화가 급속히 진행되고 있는 현재의 국내 제지산업 현황을 고려할 때 고품질의 제품을 저렴하게 생산하기 위해서는 화학첨가제의 효과적 활용기술 확립과 이를 통한 초지공정 wet end의 성공적 제어기술이 요청된다. 특히 환경보전과 환 경관련 규제에 부응하기 위하여 초지공정의 무방류화가 점차 가속화되고 있는 현 시점에 서 wet end의 효율적 관리를 위해서는 그 동안 개방형 wet end에서 적용되던 개념의 공 정관리의 한계를 극복할 수 있는 기술 개발이 필요하다. 공정의 폐쇄화에 따른 습부화학적 문제를 해결하기 위해서는 백수의 재활용에 따른 지료 화학적 특성을 평가하고 고분자전해질의 거동을 분석해야 한다. 보류향상제 혹은 탈수촉 진제로서 첨가된 고분자전해질은 그 기능을 수행하기 위해서는 섬유에 흡착이 이루어져 야 하므로 백수로 제조된 지료 내에서 고분자전해질의 흡착 특성을 파악하는 것은 습부에 서 일어나는 현상들에 대한 이해 및 효율적인 공정제어를 위한 첫 단계라 할 수 있다. 본 연구에서는 실험실적으로 제조된 백수를 이용하여 조성된 지료 내에서 양이온성 구 아 검의 흡착현상을 분석하였다. 본 연구에서는 폐쇄화의 기준으로 폐쇄화 정도(Level of C Closure ; LC)에 따라 실험을 수행하였다. 여기에서 LC란 총 사용된 물의 양에 대한 지료조성 시 사용되는 백수의 양을 백분율로 나타낸 것이다. 양이온성 구아 검의 흡착을 평가하기 위해 PhenoVsulfuric acid spectrophotometric method를 이용하여 펄프 슬 러리 상등액에 존재하는 미흡착된 양이온성 구아 검의 함량을 측정하였고. 양이온성 구아 검 이 섬유상에 흡착하였을 때 나타나는 섬유의 S-potential 변화와 펄프 상등액의 양이 온 요구량 변화를 평가하였으며 이들의 상관관계를 분석하였다.축력으로 변형시키는데 비해 도침은 단순히 압축 압력만을 종이에 가하는 것이 다르다고 볼 수 있는데, 라 이너지와 백상지가 같은 조건하에서 왜 이러한 큰 차이를 보이는 이유를 아직 알수 없다.해 동일한 공정 데이터들올 이용하여 보편적으로 사용하는 통계기법 중의 하나인 주성분회귀분석을 실시하였다. 주성분 분석은 여러 개의 반응변수에 대하여 얻어진 다변량 자료의 다차원적인 변 수들을 축소, 요약하는 차원의 단순화와 더불어 서로 상관되어있는 반응변수들 상호간 의 복잡한 구조를 분석하는 기법이다. 본 발표에서는 공정 자료를 활용하여 인공신경망 과 주성분분석을 통해 공정 트러블의 발생에 영향 하는 인자들을 보다 현실적으로 추 정하고, 그 대책을 모색함으로써 이를 최소화할 수 있는 방안을 소개하고자 한다.금 빛 용사 둥과 같은 표면처리를 할 경우임의 소재 표면에 도금 및 용 사에 용이한 재료를 오버레이용접시킨 후 표면처리를 함으로써 보다 고품질의 표면층을 얻기위한 시도가 이루어지고 있다. 따라서 국내, 외의 오버레이 용접기술의 적용현황 및 대표적인 적용사례, 오버레이 용접기술 및 용접재료의 개발현황 둥을 중심으로 살펴봄으로서 아직 국내에서는 널리 알려지지 않은 본 기 술의 활용을 넓이고자 한다. within minimum time from beginning of the shutdown.및 12.36%, $101{\sim}200$일의 경우 12.78% 및 12.44%, 201일 이상의 경우 13.17% 및 11.30%로 201일 이상의 유기의 경우에만 대조구와 삭제 구간에 유의적인(p<0.05) 차이를 나타내었다.는 담수(淡水)에서 10%o의 해수(海水)로 이주된지 14일(日) 이후에 신장(腎臟)에서 수축된 것으로 나타났다. 30%o의 해수(海水)에 적응(適應)된 틸라피아의 평균 신사구체(腎絲球體)의 면적은 담수

  • PDF

Optimal DO Setpoint Decision and Electric Cost Saving in Aerobic Reactor Using Respirometer and Air Blower Control (호흡률 및 송풍기 제어 기반 포기조 최적 DO 농도 설정과 전력 비용 절감 연구)

  • Lee, Kwang Su;Kim, Minhan;Kim, Jongrack;Yoo, Changkyoo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.5
    • /
    • pp.581-586
    • /
    • 2014
  • Main objects for wastewater treatment operation are to maintain effluent water quality and minimize operation cost. However, the optimal operation is difficult because of the change of influent flow rate and concentrations, the nonlinear dynamics of microbiology growth rate and other environmental factors. Therefore, many wastewater treatment plants are operated for much more redundant oxygen or chemical dosing than the necessary. In this study, the optimal control scheme for dissolved oxygen (DO) is suggested to prevent over-aeration and the reduction of the electric cost in plant operation while maintaining the dissolved oxygen (DO) concentration for the metabolism of microorganisms in oxic reactor. The oxygen uptake rate (OUR) is real-time measured for the identification of influent characterization and the identification of microorganisms' oxygen requirement in oxic reactor. Optimal DO set-point needed for the micro-organism is suggested based on real-time measurement of oxygen uptake of micro-organism and the control of air blower. Therefore, both stable effluent quality and minimization of electric cost are satisfied with a suggested optimal set-point decision system by providing the necessary oxygen supply requirement to the micro-organisms coping with the variations of influent loading.