• Title/Summary/Keyword: 발전소 온배수

Search Result 82, Processing Time 0.022 seconds

원자력발전소 온배수에 따른 우렁쉥이의 성장

  • 김성길;곽희상;강주찬
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2001.10a
    • /
    • pp.331-332
    • /
    • 2001
  • 발전소 등에서 배출되는 온배수는 해수의 수은을 변화시키며, 이로 인해 해양생태계에 많은 영향을 미친다 (Naylor, 1965). 발전소 온배수에 의해 27.2$^{\circ}C$~31.$0^{\circ}C$의 수온상승은 부착성 군집구조 가 우세하며, 37$^{\circ}C$이상의 수온에서는 수주고둥 및 따개비류를 제외한 모든 동ㆍ식물이 소멸한다 (Suresh et al., 1993). 또한, Ahamed et al. (1992)는 발전소 온배수의 영향을 받는 해역에서는 소수의 수주고둥과 남조류를 제외하고 해양생물 출현이 없었다고 보고하였다. (중략)

  • PDF

Analysis of 1MW Closed OTEC Cycle Using Thermal Effluent and Waste Heat (발전소 온배수를 이용한 1MW급 폐쇄형 해양온도차발전 성능해석)

  • Kim, Hyeon-Ju;Lee, Ho-Saeng;Jung, Dong-Ho;Moon, Deok-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.470-476
    • /
    • 2010
  • The thermodynamic performance of closed ocean thermal energy conversion (OTEC) cycle with 1 MW gross power was evaluated to obtain the basic data for the optimal design of OTEC. The basic thermodynamic model for OTEC is Rankine cycle and the thermal effluent from power plant was used for the heat source of evaporator. The cycle performance such as efficiency, heat exchanger capacity, etc. was analyzed on the temperature variation of thermal effluent. The saturated pressure of evaporator increased with respect to the increase of thermal effluent temperature, so the cycle efficiency increased and necessary capacity of evaporator and condenser decreased under 1 MW gross power. As the thermal effluent temperature increases about $15^{\circ}C$, the cycle efficiency increased approximately 44%. So, it was revealed that thermal effluent from power plant is important heat source for OTEC plant. Also, if there is an available waste heat, it can be transferred heat to the working fluid form the evaporator through heat exchanger and cycle efficiency will be increased.

The Estimation of Marine Environmental Capacity for the Reception of Cooling Water from HTPP in Southern Waters of Cheju Island using a 3-D Hydrodynamic Model (화순화력발전소 주변해역의 온배수 환경용량 산정)

  • Kim Gwang-Su;Choi Young-Chan;Lee Moon-Jin
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.3
    • /
    • pp.3-12
    • /
    • 2000
  • The field surveys and the measurements of seawater temperatures were conducted every month from 1997 to 1999, and the distributions of seawater temperature were simulated and reproduced by a three dimensional hydrodynamic numerical model over the southern waters of Cheju island. In order to estimate the marine environmental capacity for the reception of the heat loads of cooling water discharged from Hwasoon Thermal Power Plant(HTPP) in the study area, the simulations for predicting the situation of unfavorable environment in which marine organisms might not be satisfied with change in seawater temperature were peformed using a three dimensional hydrodynamic numerical model by controlling quantitatively the heat loads of cooling water from HTPP Currently, HTPP discharges cooling water of 35.9℃ into the sea as much as 112,800m³/day in summer. As the results of simulations, the more the heat loads from the power plant increase, the more increase the seawater temperatures around the water areas adjacent to the power plant. In case the heat loads of cooling water from HTPP become about 5 times as high as the present loads, seawater temperatures at near-shore waters adjacent to HTPP appear to be increased to the extent of 0.5℃ above the existing seawater temperature in summer. The marine environmental capacity for the reception of thermal discharge from HTPP is estimated to be about 530×10/sup 6/kcal/day which is equivalent to the increase of a factor of 2 in the temperature of cooling water without any change in the discharge rate of cooling water or which is equivalent to the increase of a factor of 4.6 in the discharge rate of cooling water without any change in the temperature of cooling water. Comparing the case of the increase in the discharge rate of cooling water with the case of the increase in the temperature of cooling water on the basis of the same heat loads of 530×10/sup 6/kal/day, the former case is expected to increase seawater temperature a little higher and to extend the area affected by heat loads a little broader.

  • PDF

The trend of Energy ICT in automated agriculture and EMS system for cooling water application in power plant (시설농업에서 에너지 ICT 와 발전소 온배수 활용을 위한 에너지관리시스템)

  • Hwang, Woo-jeong;Kim, Kwang-kyu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.623-625
    • /
    • 2015
  • Recently, the cooling water of power plant was included in RPS(Renewable Portpolio Standard) as water heat energy. Thus the trend of cooling water application is growing bigger for agriculture and fishing industry. Especially as energy consumption cost in agriculture and fishing industry is a vital element, the interests for energy efficiency is growing bigger. The advanced agriculture country like Netherlands is distributing diagnosis software to the farmers based on ICT diagnostic system for the efficient energy consumption and energy demand amounts depend on crops of cultivation in automated horticulture. Hereafter, in the preparation of the expansion of the automated agriculture domestically by the cooling water of power plant, we would like to propose the energy application case(Greenery) in the advanced countries abroad in agriculture and EMS system about the application of the cooling water in power plant.

  • PDF

Investigation of Hydraulic Flow Properties around the Mouths of Deep Intake and Discharge Structures at Nuclear Power Plant by Numerical Model (수치모의를 통한 원자력 발전소 심층 취·배수 구조물 유·출입구 주변에서의 수리학적 흐름특성 고찰)

  • Lee, Sang Hwa;Yi, Sung Myeon;Park, Byong Jun;Lee, Han Seung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2A
    • /
    • pp.123-130
    • /
    • 2012
  • A cooling system is indispensable for the fossil and nuclear power plants which produce electricity by rotating the turbines with hot steam. A cycle of the typical cooling system includes pumping of seawater at the intake pump house, exchange of heat at the condenser, and discharge of hot water to the sea. The cooling type of the nuclear power plants in Korea recently evolves from the conventional surface intake/discharge systems to the submerged intake/discharge systems that minimize effectively an intake temperature rise of the existing plants and that are beneficial to the marine environment by reducing the high temperature region with an intensive dilution due to a high velocity jet and density differential at the mixing zone. It is highly anticipated that the future nuclear power plants in Korea will accommodate the submerged cooling system in credit of supplying the lower temperature water in the summer season. This study investigates the approach flow patterns at the velocity caps and discharge flow patterns from diffusers using the 3-D computational fluid dynamics code of $FLOW-3D^{(R)}$. The approach flow test has been conducted at the velocity caps with and without a cap. The discharge flow from the diffuser was simulated for the single-port diffuser and multi-ports diffuser. The flow characteristics to the velocity cap with a cap demonstrate that fish entrainment can significantly be minimized on account of the low vertical flow component around the cap. The flow pattern around the diffuser is well agreed with the schematic diagram by Jirka and Harleman.

Environmental Effects on the Benthic Polychaete Communities Around the Power Plant Areas in the East Sea of Korea (동해 발전소 주변의 저서다모류 군집에 영향을 미치는 환경 요인)

  • KWON, SOON HYUN;LEE, JAE HAC;YU, OK HWAN
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.22 no.1
    • /
    • pp.18-30
    • /
    • 2017
  • The East Sea is almost entirely composed of sandy facies, and the facies type is the major factor influencing benthic polychaete communities. There have been few studies of the effects of environmental factors on benthic polychaetes in thermal discharge areas consisting of different sediment types. This study identified the spatial distribution patterns based on the species composition and distribution of benthic polychaete communities, and the environmental factors influencing benthic polychaetes near power plants were investigated. The polychaete communities in the Uljin, Hupo, and Gori coastal areas near the power plants in the East Sea were seasonally investigated from August 2006 to February 2013. As a result, 283 species were collected. The dominant species were Spiophanes bombyx, Magelona japonica, Lumbrineris longifolia, and Sternaspis scutata. Spiophanes bombyx was the dominant species at Uljin and Hupo, but M. japonica was the dominant species at Gori. Two dominant species from the coastal waters of the East Sea, Lumbrineris longifolia and M. japonica, were rare in the power plant water intake or drainage areas. Cluster analysis was performed to divide the study area into groups by the total organic carbon content, sediment grain size and facies patterns. This study suggests that the community structures of polychaetes are more affected by the total organic carbon, grain size of sediment and facies than by disturbance from thermal discharge, which only affected the polychaete community near power plant drainage areas.

Investigation about the Decrease Efficiency of Thermal Discharge Temperature at Mixing Basin of Power Plant using 3-D CFD (3차원 수치모의에 의한 발전소 배수로 혼합지에서의 온배수 수온저감 효과에 대한 고찰)

  • Park, Byong-Jun;Lee, Sang-Hwa;Park, Ji-Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.593-593
    • /
    • 2012
  • 본 연구는 화력 및 원자력 발전소로 취입된 냉각수(circulating and essential service water)가 복수기로부터 온배수 형태의 개수로 흐름으로 표층배수 될 경우 수온을 저감시키기 위해 주입하는 희석수(by-pass cooling water)와의 혼합효과의 효율성을 증대시키고, 불리한 수리현상을 야기하지 않으며, 경제적인 배수로 구조물을 고찰하기 위한 목적으로 시도되었다. 배수로 구조물 내 온배수와 희석수가 혼합되는 구간을 혼합지(mixing basin)라 하는데, 본 과업에서는 ${\bigcirc}{\bigcirc}$발전소의 배수로 구간 중 혼합지를 대상으로 FLOW-3D$^{(R)}$를 이용한 3차원 수치모형을 구축하고, 총 9개에 해당하는 각 대안별 현상을 분석하고 비교하였다. 각 대안들의 차이점은 배수로에 설치되는 보조구조물들의 형상과 배열 등이며, 복수기로부터 나오는 배출수의 수온은 $42^{\circ}C$, 희석수는 $35^{\circ}C$이고, 본 과업의 주요 관심대상 물리량은 유속과 온도이다. 배수로에 아무런 보조 구조물이 없는 형태인 기본 계획안을 검토한 결과, 평균 $3.31^{\circ}C$의 수온강하가 이루어졌으나, 우안 쪽으로 강한 흐름이 발생하여 수온의 좌우편차가 $4.61^{\circ}C$ 가량 발생하는 것으로 나타났다. 기본 계획안의 검토결과를 보완하기 위한 대안으로 연직 흐름의 소산을 위해 고안된 잠형 소파블록(baffle block) 설치안은 평균 $3.06^{\circ}C$의 수온강하가 이루어지고 $4.44^{\circ}C$의 수온 좌우편차가 발생했다. 지그재그(zigzag) 형태의 흐름을 만들어 혼합효과를 올리기 위한 미로형 수제(labyrinth groin) 설치안은 평균 $5.33^{\circ}C$의 수온강하가 이루어지고, $1.43^{\circ}C$의 수온 좌우편차를 보여줘 검토했던 대안들 중 가장 좋은 결과를 보여주었다. V자 배열 소파블럭(deformed block) 설치안은 연직 및 수평방향의 소산을 기대했으나 평균 $3.00^{\circ}C$의 수온 강하와 $4.41^{\circ}C$의 수온 좌우편차를 나타냈다. 벤츄리(Venturi) 형태의 흐름을 발생시키기 위한 병목형(bottleneck) 수로안은 평균 $3.18^{\circ}C$의 수온강하와 $3.94^{\circ}C$의 수온 좌우편차, 흐름의 소산과 흐름방향을 변화시키기 위한 와형 수제(swirl groin) 설치안은 평균 $2.24^{\circ}C$의 수온강하와 $1.48^{\circ}C$의 수온좌우편차, 우안 흐름을 지연시키기 위한 물방석(water cushion) 수로안은 평균 $3.03^{\circ}C$의 수온강하와 $4.50^{\circ}C$의 수온 좌우편차, 우안의 흐름을 좌안으로 보내기 위한 분사형(injector) 수로안은 평균 $3.13^{\circ}C$의 수온강하와 $4.45^{\circ}C$의 수온 좌우편차, 우안의 흐름을 막기 위한 외팔형 수제(cantilever groin) 설치안은 평균 $3.11^{\circ}C$의 수온강하와 $3.02^{\circ}C$의 수온 좌우편차가 발생하는 것으로 나타났다.

  • PDF

Effects of Cooling Water System of a Power Plant on Marine Organisms II. Effects on Benthic Organisms (화력발전소 냉각계통이 해양생물에 미치는 영향 II. 저서생물에 미치는 영향)

  • YI Soon Kil
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.5
    • /
    • pp.391-407
    • /
    • 1987
  • To understand the effects of the cooling water system of the power plant on the succession of sessile zoobenthos, a series of experiments were carried out at the cooling water system of Samchonpo Power Plant from Hay 1985 to May 1986. The lowest species diversity of the zoobenthos was observed at the discharge canal. This is probably caused by both increased velocity and temperature of circulating water. It is also noticeable that species composition of the zoobenthos, to a certain degree, was affected due to the impingement of meroplankton during the entrainment process. While the number of species attached on the experimental substrata installed in the thermally altered area is smaller than that in the intake canal, the biomass is increased as the increased temperature eliminates some species and in turn stimulates reproduction and growth of the others. It is interesting that relatively high similarity exists between the summer communities in the intake canal and the spring communities in the thermally altered area, and the same relationship is also found between the fall communities in the intake canal and the winter communities in the thermally altered area. Ecological index curves of the zoobenthos of the intake canal follows the fluctuation pattern of the thermally altered area in one or two months of elapsed time, probably due to temperature increase by the inflow of heated water discharged from the power plant.

  • PDF