Risk evaluation of EVA dust with oxidizer by a pressure vessel (압력용기시험에 의한 EVA분진의 혼촉 위험성 평가)

  • 이창우;김정환;현성호
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.7-12
    • /
    • 1999
  • Thermal properties of EVA dust and its risks of coexisting with oxidizer were investigated by a pressure vessel. The decomposition of EVA dust with temperature using DSC and the weight loss with temperature using TGA were also investigated to find the thermal hazard of EVA dust. Using the pressure vessel which can estimate ignition and explosion of EVA dust coexisting with oxidizer by bursting of a rupture disc, many experiments have been conducted by varying the orifice diameter, heating rate, the weight ratio of the sample coexisting with oxidizer, and the species of oxidizer. According to the results of the thermal analysis of EVA dust, a little change of the decomposition initiation temperature with the heating rate could be found and the decomposition temperature zone of EVA dust was 250 to 50$0^{\circ}C$. The risk of EVA dust coexisting with oxidizer was increased as the orifice diameter was decreased. On the other hand, it was increased as the heating rate and the weight ratio of the sample coexisting with oxidizer were increased. In addition, the risk of EVA dust coexisting with oxidizer was affected by the decomposition temperature of the sample and oxidizer, respectively, at slow heating rate, but it was affected by the oxygen weight percent of oxidizer at fast heating rate.

  • PDF

Energy saving control system of wireless base station utilizing natural air-conditioning (자연공조를 활용한 무선기지국 Energy절감 제어시스템)

  • Ryu, Gu-Hwan;Kwon, Chang-Hee
    • Journal of Digital Convergence
    • /
    • v.17 no.10
    • /
    • pp.223-232
    • /
    • 2019
  • With the development of the information communication industry, the size of the communication device has been reduced to a system that generates a large amount of heat. Therefore, since the amount of heat generated by the wireless equipment is large in the wireless base station, the energy consumption is continuously consumed and the failure of the wireless base station may occur. Therefore, in this study, The study was analyzed. As a research method, we performed base station with a lot of calorific value and electric charge. We selected 25 base stations and obtained data for two weeks. To ensure reliability, the room temperature was kept constant at $27^{\circ}C$, and the control system was installed and equiped for two weeks to obtain the date analysis. In order to calculate the test results in the study method, the instrument was used with a computer, a digital thermometer, and dust measurement. For the date analysis, we conducted a research study on 25 wireless basestations before and after the installation of Control Sysetm.

A study on thermal and mechanical properties according to the structures of conductor sleeve and the method of connection for EHV Cables (전력 케이블용 접속 슬리브의 구조 및 접속 방법에 따른 특성 연구)

  • Kim, Young-Bum;Han, Bong-Soo;Ryu, Jeong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1493_1494
    • /
    • 2009
  • 초고압 전력 케이블용 도체 접속을 위한 접속방법으로 압축형(compressing type), 용접형(welding type), 압축-용접형(CW type; compressing-welding type)의 슬리브는 물론 동과 알루미늄의 이종(nonidentical materials) 접속을 위한 슬리브를 개발 하였으며, 전기적, 기계적으로 검증된 제품 개발을 위하여, 슬리브의 구조 변경과 접속 방법의 차이뿐 아니라 접속 전후의 응력 평가를 위해 슬리브 시편의 인장시험(tensile strength) 결과에 따른 슬리브 제작 및 시험을 진행하였다. 신뢰성 있는 제품 개발과 데이터를 얻기 위하여 초고압용 지중 고압 케이블을 시험 시료로 적용하여 시험 선로(test loop)를 구성하였으며, 이를 통하여 구조와 재질에 따른 접속 방법, 이상 온도 상승 또는 국부적인 고온 부위 발생 여부 등의 전기 시험 및 열싸이클 전압 시험(heating cycle voltage test) 조건을 설정하여 시험 전후의 열신축 등 전기적, 기계적 특성을 평가하였다. 접속 슬리브의 구조 및 재질에 따른 위치별 발열 양상을 체크하였으며, X-ray 장비를 이용하여 슬리브 내부의 압축 및 충진 정도를 점검함으로써 기존 접속 슬리브 보완은 물론 개발된 접속 슬리브의 설계 기준 및 안전율을 설정 할 수 있었다.

  • PDF

A Test and Evaluation System to Secure a Long Time Reliability of Motor (전동기의 장기 신뢰성 확보를 위한 시험 및 평가 시스템)

  • 김기준;신봉희;정병태
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2000.11a
    • /
    • pp.367-372
    • /
    • 2000
  • 국내 도시 철도에 차량 견인용으로 사용되는 전동기는 인버터로 구동되는 200㎾급 3상농형 유도 전동기를 표준 사양으로 선정하였으며 열악한 운전 조건에서도 20년을 상회하는 운전 수명을 보장하도록 규정하고 있다. 그러나 PWM 인버터 구동은 견인 전동기에서 추가적인 고조파 발열 손실과 소음, 진동을 초래하며 더욱이 고속 스위칭에 의한 과도 전압과 빠른 상승 시간을 가진 반복 과전압은 인버터와 전동기를 연결하는 케이블 공진 현상에 의해 배가되어 정현파 구동 시에 예상할 수 없었던 매우 커다란 스트레스를 절연 시스템에 가하게 되어 견인 전동기의 예상 수명에 심각한 영향을 미치고 있다. 따라서 본 연구에서는 인버터 구동 견인전동기의 운전수명을 보장하기 위해서는 기존의 시험 방법에 포함되지 않은 PWM 가변속 구동에 따른 고조파 손실과 과도 전압 충격의 문제점을 고려한 새로운 장기 신뢰성 평가기법이 절실히 필요한 상황이기 때문에 이를 제안하고자 하였다.

  • PDF

Analysis of Deterioration Characteristics for Connection Factor used m Grounding System (접지시스템에 사용되는 접속요소의 열화특성 분석)

  • Jang, Ung Burm
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2022.10a
    • /
    • pp.167-168
    • /
    • 2022
  • 본 논문에서는 접지계통에 사용되는 접속계수에 대한 열화특성 분석을 기술한다. 그 접지 시스템의 연결 방법은 IEC 표준에 명시되어 있습니다. 연결부의 열화 특성을 분석하기 위해 인자, 연결 인자를 소금물과 지하에 묻었을 때 열화 시험을 수행하였다. 테스트 연결 계수 C형 슬리브, 클램프 및 발열 용접이 있었습니다. 그 결과, 접속 인자의 대부분이 부식되었고, 전기적 요인이 발생하였다. 저항은 악화된 후에 감소했다. 분석 결과는 접지 시스템의 안전성을 확립하는 데 사용될 수 있다

  • PDF

A Study on Analysis of Characteristics Combustion of Floor Covering Materials (바닥내장재의 연소특성 분석에 관한 연구)

  • Park, Young-Ju;Lee, Hae-Pyeong;Kim, Hyun-Ju
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.77-83
    • /
    • 2010
  • In this study, we analyzed the combustion characteristics of four different floor covering materials(wood, monorium, laminatedpaper, and varnish-laminated paper) with regard to their ignitibility, thermal characteristics and flame retardancy by using an ignition temperature tester, a dual cone calorimeter, a thermogravimetric analyzer and limited oxygen index, for their fire risk assessment. According to the result, monorium had the lowest ignition temperature of $325^{\circ}C$ and the laminated paper and the varnish-laminated paper promptly ignited before 7s. Further, the wood showed the largest total heat release of $100MJ/m^2$, and the varnish-laminated paper showed the highest peak heat release rate. From the thermogravimetric analysis, it was shown that all specimens underwent rapid weight loss at $300{\sim}400^{\circ}C$. The limit oxygen indices of the laminated paper and the varnish-laminated paper were in the range of 20~21%, while it was 34% for wood. This study enabled us to confirm that wood, laminated paper and varnish-laminated paper have a relatively short ignition time and are easy to burn but they all have low heat release. In contrast, wood showed the lowest fire risk among them and had excellent flame retardancy but with high heat release.

Effects of CNT Additions on Mechanical Properties and Microstructures of Cement (CNT 첨가량에 따른 시멘트의 역학성능 및 미세구조의 영향)

  • Oh, Sungwoo;Oh, Kyeong-seok;Jung, Sang-hwa;Chung, Wonseok;Yoo, Sung-won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.162-168
    • /
    • 2017
  • Carbon nanotube(CNT) is one of the promising construction materials to produce concrete with high strength and durability by adding in the concrete mixtures from various researches. Also, its superior heat conductivity can be one of the options to develop self-heating concrete. In this research, the fundamental study was conducted to investigate mechanical properties and microstructures of cement pastes and mortars by strength tests and porosity measurement with several CNT additions, which were 0 wt%, 0.115 wt%, 0.23 wt% and 0.46 wt% of CNT-cement ratio. Compressive and flexural strength test were conducted at 3, 7 and 28 days, and pore characteristics were investigated by mercury intrusion porosimetry. SEM-EDS and Thermogravimetric analysis(TGA) were conducted to prove the hydration product types and CNT dispersion in the cement matrix. As a result, even though high amount of CNT additions were caused worse performance, mixtures with 0.115 wt% of CNTs developed the similar performance with plain mixture.

A Study on the Resistance to Sea Water and High Flowing Properties of Concrete Using Blended Low Heat Cement (혼합형 저발열 시멘트를 사용한 콘크리트의 초유동성 및 내해수성에 관한 연구)

  • 송용순;노재호;강석화
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.281-289
    • /
    • 1998
  • This study has been performed to test the flowability and filling ability of high flowing concrete as well as distribution of aggregate and pore of core specimen, heat of hydration, compressive strength and core strength of concrete. In addition, the resistance to chloride ion penetration and chemical solutionof concrete was tested in order to evaluate the resistance to sea water of concrete and its application of high flowing concrete using blended low heat cement in the field of Seohae Grand Bridge. The properties of high flowing concrete with blended low heat cement were compared with ordinary 25-240-15 concrete using Type V cement. As the results of this study, the flowability and filling ability of high flowing concrete with blended low heat cement is satisfied without vibration. Though the cement content of high flowing concrete with blended low heat cement was 400kg/m$^2$, the rising temperature of it was relatively lower than that of the ordinary 25-240-15 concrete with Type V cement. Also, the compressive of high flowing concrete with blended low heat cement is similar to that of the ordinary 25-240-15 concrete with Type V cement.

Assessment on Applicability of Recycled Aggregates for Backfill Materials of Underground Transmission Lines Based on Field Demonstration Tests (지중 송전관로 되메움용 순환골재의 현장실증시험을 통한 적용성 평가)

  • Kang, Sung-Chur;Lee, Kang-Ryel;Ahn, Tae-Bong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.1
    • /
    • pp.72-83
    • /
    • 2015
  • Underground transmission lines always generate heat and transmit heat through surrounding backfill materials. Therefore, in the design of power lines it becomes a very crucial factor to transfer heat effectively into the neighbouring soils. In this study, in order to enhance field applicability of recycled aggregates for backfill material of transmission lines, quality criteria and construction criteria were proposed, and thermal stability of power lines through field demonstration tests were analyzed. In the field tests, two types of recycled aggregates and sand which is currently used for backfilling were compared in terms of thermal behaviour. Test results showed that recycled aggregates represented similar trends with sand in temperature and moisture content corresponding to time lapse and distance from the heat source. Consequently, recycled aggregates can be utilized for backfill materials of underground transmission lines as a substitute material of sands.

A Study on Field Application of the Mass Concrete using Hydration Temperature-Reducing Binder - Focused on the Laboratory Test - (수화 온도 저감형 결합재를 이용한 매스콘크리트 현장적용에 관한 연구 - 실내시험 중심으로-)

  • Lee, Ji-Hwan;Lee, Jin-Woo;Park, Hee-Gon;Kang, Chang-Gu;Bae, Yeoun-Ki;Lee, Jae-Sam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.259-260
    • /
    • 2010
  • This study is to investigate each mix property and physical properties and reduction properties of heat of hydration as basic experiment of reviewing the applicability of low calorific concrete.

  • PDF