• Title/Summary/Keyword: 반복횡하중

Search Result 146, Processing Time 0.019 seconds

Seismic Experiment of Precast Concrete Exterior Beam-Column Joint Using Bolt Type Connection and Prestressing Method (볼트 접합 및 프리스트레스를 적용한 프리캐스트 콘크리트 보-기둥 외부접합부의 내진실험)

  • Lee, Dong-Joo;Lee, Ju-Dong;Oh, Tae-Soo;Kang, Thomas H.K.
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.2
    • /
    • pp.125-133
    • /
    • 2014
  • In this study, experimental research was carried out to investigate the seismic and structural performance of precast concrete exterior beam-column joints using bolt type connection and prestressing method. A total of five full-scale exterior beam-column joints were constructed and tested under reversed cyclic loading, controlled by displacement. Results of the test are as follows: Energy dissipation capacity and pinching phenomenon of PC beam-column joints showed disadvantageous behavior compared to RC beam-column joints. However, drift capacity of the PC joint was excellent. Also, yield mechanism concentrated on embedded nuts was suitable as an exterior beam-column joint of lateral load resistance frame. Additional application of prestressing method was also very effective to control excessive pinching and cracking in the joint region, and thus improved an overall seismic performance of the PC joint.

Seismic Performance Evaluation of Reinforced Concrete Columns by Applying Steel Fiber-Reinforced Mortar at Plastic Hinge Region (소성힌지부 강섬유 혼입 모르타르 적용 철근콘크리트 기둥의 내진성능평가)

  • Cho, Chang-Geun;Han, Sung-Jin;Kwon, Min-Ho;Lim, Cheong-Kweon
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.241-248
    • /
    • 2012
  • This paper presents a reinforced concrete composite column method in order to improve seismic performance of reinforced concrete column specimens by selectively applying steel fiber-reinforced mortars at the column plastic hinge region. In order to evaluate seismic improvement of the newly developed column method, a series of cyclic load test of column specimens under a constant axial load was investigated by manufacturing three specimens, two reinforced concrete composite columns by applying steel fiber-reinforced mortars at the column plastic hinge region and one conventional reinforced concrete column. Both concrete and steel fiber-reinforced mortar was cast-in placed type. From cyclic load test, it was found that the newly developed steel fiber-reinforced columns showed improved seismic performances than conventional reinforced concrete column in controlling bending and shear cracks as well as improving seismic lateral load-carrying capacities and lateral deformation capacities.

Hysteretic Behavior of R/C Shear Wall with Various Lateral Reinforcements in Boundary Columns for Cyclic Lateral Load (경계부재내 횡보강근 배근방법에 따른 R/C전단벽의 반복하중에 대한 이력거동)

  • Seo, Soo-Yeon;Oh, Tae-Gun;Kim, Kyeong-Tae;Yoon, Seong-Joe
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.357-366
    • /
    • 2010
  • This paper presents experimental results about shear wall with various lateral reinforcement details in boundary elements. The research objective is to study the structural behavior of shear wall with boundary column confined by rectangular spiral hoops and headed cross ties developed to improve workability in the fabrication of boundary columns. These two details can be fabricated in a factory and put together on-site after being delivered so that the construction work may be reduced. Main parameters in the experimental study were the types of hoop and cross tie: rectangular spiral hoop and headed cross tie vs. standard hoop and cross tie with hook. Four half scaled shear wall specimens with babel shape were made and tested by applying horizontal cyclic load under constant axial force, 10% of nominal compressive strength of concrete. Based on the test result, it was shown that the shear wall with rectangular spiral hoop and headed cross tie in boundary columns has structural capacity compatible with conventional shear wall. The specimen SW-Hh which has bigger hoop bar and higher volumetric ratio of transverse reinforcements than other showed improved energy dissipating characteristic but it presented a rapid reduction of strength after peak point. The results indicates that, it is necessary to consider volumetric ratio of transverse reinforcements as well as hoop space in designing of shear wall with boundary columns for improved strength and ductility.

Capacity Evaluation of Joint Reinforcement with Debonding Area at the Interface Steel to Concrete Surface (접합부 철근의 비부착에 따른 성능평가)

  • Jung, Woo-Young;Ha, Keum-Hee
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.67-70
    • /
    • 2011
  • 해안에 위치한 철근콘크리트 구조물 및 사회 간접 시설물들은 염해피해에 대한 우려가 있다. 염해피해로 인한 철근의 부식현상이 발생하면 철근과 콘크리트 부착성능의 저하로 인한 부재의 내력감소를 가져 올 수 있다. 따라서 본 연구에서는 염해부식이 진행되어 콘크리트와 철근간의 부착 및 비부착 여부에 따른 성능을 확인하기 위하여 완전 비부착된 보-기둥 접합부를 철근부착용 고무튜브를 이용하여 제작하였다. 제작된 실험체로 준정적 반복횡하중을 이용한 실험을 통해 성능평가를 수행하였다. 비부착된 보-기둥 접합부의 비선형 해석을 하기 위해 4절점 래티스 모델로 개선하여 적용하였다.

  • PDF

Development of Resizing Techniques for Drift Designs of High-rise Buildings subjected to Lateral and Vertical Loads (횡하중과 연직하중을 받는 고층건물의 변위설계를 위한 재분배기법 개발)

  • 서지현;박효선
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.1
    • /
    • pp.49-58
    • /
    • 2004
  • Drift design of a high-rise building is a governing factor in the determination of structural weights and lateral resisting systems. However, high-rise buildings are composed of tens of thousands of structural member, designer can not know which members are active to lateral drift control and how much they contribute to lateral drifts. Resizing technique was proved to be a practical method for drift design of high-rise buildings. However, no resizing algorithm has been considered the effect of vertical loads in drift designs. Thus, in this paper, a resizing algorithm has been developed for drift designs of high-rise buildings subjected to both lateral and vertical loads. The drift design model has been applied to drift designs of two high-rise building examples.

Seismic Behavior of High-Strength Reinforced Concrete Bridge Columns (고강도 철근콘크리트 교각의 내진 거동)

  • Hwang Sun-Kyoung;Lee Chin-Ok;Ryu Hyo-Jin;Yun Hyun-Do;Lim Byung-Hoon
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.505-511
    • /
    • 2005
  • This experimental investigation was conducted to examine the seismic performance of reinforced concrete bridge columns. The columns were subjected to a constant axial load and a cyclic horizontal load-inducing reversed bending moment. The variables studied in this research were the volumetric ratios of transverse reinforcement (ps=0.96, 1.44 percent) and axial load ratios (P/Po=0.05, 0.1, 0.2) and concrete strengths (35, 60MPa). Test results showed that bridge columns with $44\%$ higher amounts of transverse reinforcement than that required by seismic provisions of ACI 318-02 showed ductile behavior. For bridge columns with axial load ratio(P/Po) less than 0.2, the ratio of $M_{max}\;over\;M_{ACI}$, nominal moment capacity predicted by ACI 318-02 provisions, was consistently greater than 1 with approximately a $20\%$ margin of safety.

Behavior of Monopile for Offshore Wind Turbine in Loose Silty Sand under Lateral Cyclic Loading via Centrifuge Model Test (원심모형실험을 활용한 느슨한 실트질 모래지반에서 해상풍력 모노파일의 반복수평하중에 대한 거동 평가)

  • Lee, Jae-Kweon;Yun, Sung-Min;Jeon, Young-Jin;Kim, Jae-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.40 no.4
    • /
    • pp.33-47
    • /
    • 2024
  • Offshore wind structures are subject to long-term repeated horizontal loads from wind, waves, and currents, making it essential to consider these loads in the design of offshore foundations. In this respect, monopiles are large-diameter hollow steel pipes that are relatively simple to construct compared with piles used on onshore sites. They can provide stable support for wind structures and have well-established design codes, leading to their widespread use globally. The behavior of monopiles under lateral static loads is typically assessed using the p-y method proposed by the American Petroleum Institute (API). However, the applicability of p-y curves to large-diameter monopiles exposed to repeated cyclic horizontal loads, such as those experienced in offshore wind applications, must yet be evaluated. Thus, this study evaluated the behavior of monopiles under two-way cyclic horizontal loads in loose silty sand, a representative soil type of the southwestern coast of Korea, using centrifuge model tests. The results demostrated that the behavior of monopiles varied depending on the loading level, number of cycles, and direction of the cyclic loads. Furthermore, the p-y curve method proposed by the API overestimated the behavior of a large-diameter monopile installed in silty sand under two-way cyclic loads.

Nonlinear Finite Element Analysis of Reinforced Concrete Columns with Steel Clip-Type Implements Subjected to Cyclic Lateral Loading (반복 횡하중이 작용하는 강재 클립형 연결장치로 결속된 철근 콘크리트 기둥의 비선형 유한요소해석)

  • Yong Joo Kim;Byong Jeong Choi
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.4
    • /
    • pp.243-250
    • /
    • 2023
  • Both ends of the hoop reinforcement in the reinforced concrete (RC) columns subjected to lateral loading must necessarily be bent by 135° so as to ensure a sufficient level of ductility. However, as this reinforcement is extremely difficult to construct, this requirement is often not satisfied at construction sites. This study entailed an experimental investigation on RC columns subjected to cyclic lateral loading equipped with steel clip-type implements that were developed to replace the complicated 135° hoop reinforcement details. Four RC column specimens were manufactured, and the main test parameters included the use of high-strength concrete and steel clip-type implements. Furthermore, three-dimensional finite element models were employed to evaluate the structural performances of the test specimens via nonlinear analyses. The results of the test and finite element analyses indicate that the RC columns with the steel clip-type implements exhibit structural performances equal to or better than those with the 135° hoop reinforcement details. Further, the finite element analysis results agree well with the test results.

Reversed Cyclic Latcral Load Test of A 2-Bay 2-Story Reinforced Concrete Frame With Seismic Detail (내진상세를 가진 2경간 2층 철근콘크리트 골조의 반복횡하중 실험)

  • Lee, Han-Seon;Woo, Sung-Woo
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.6
    • /
    • pp.183-193
    • /
    • 1996
  • The objective of this study is to investigate the characteristics of elastic and inelastic bekavior of ductile momenting-resisting reinforced concrete frame subjected to reversed lateral loading such as earthquake excitations. For this purpose, a 2-bay 2-story reinforced concrete plane frame with seismic detail was designed and one 1/2.5-scale subassemblage was manufactured according to the required similitude law. Then, the reversed load test under the displacement control was performed statically to this subassemblage. Finally, the results of this test were analysed regarding to (1) the design load vs actual strength, (2) degradation in stiffness and strength. (3) failure mode or energy dissipation. (4) local deformations.

Behavior of Solid Circular RC Piers without Seismic Detailing Subjected to Cyclic Lateral Load (수평 반복하중을 받는 비내진상세 RC 중실원형교각의 거동특성)

  • 김재관;김익현;임현우;전귀현
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.83-95
    • /
    • 2001
  • Scale model tests were performed to investigate the seismic behavior and capacity of reinforced concrete piers that were not detailed for seismic load. The prototype pier is of solid circular section. Additional lateral reinforcing bars were not provided that might be required for the confinement. Two kinds of reinforcement details are considered for the vertical longitudinal reinforcing bars: lap spliced and continuous. In the case of lap spliced model all the longitudinal bars were lap spliced at the same height in the bottom plastic hinge zone. Three specimens were constructed and subjected to quasi-static cyclic lateral loading while the vertical load held constant. Non-ductile failure modes were observed in the test of lap spliced models but limited ductile behavior was observed in the test of a continuous longitudinal reinforcement model.

  • PDF