• Title/Summary/Keyword: 반복습도

Search Result 54, Processing Time 0.022 seconds

Analysis of Chloride Ion Penetraion for Marine Concrete Structure with Cyclic Humidity Environment (건습이 반복되는 환경하의 해양콘크리트 구조물에 대한 염소이온 침투 해석)

  • Han, Sang-Hun
    • Ocean and Polar Research
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2004
  • The diffusion model, which considers diffusion and sorption, is proposed. The FEM program developed on the basis of the diffusion model provides the estimation of chloride concentration according to cyclic humidity and sorption. After the humidity diffusion analysis is carried out, the chloride ion diffusion and sorption analysis are conducted on the basis of the preestimated humidity data in each element. Each element has different analysis variables at different ages and locations. At early ages, the difference between inner and outer relative humidity causes the chloride ion penetration by sorption. As the humidity diffusion reduces the difference with age, the effect of sorption on the chloride ion penetration decreases. By the way, the cyclic humidity increases the effect of sorption on the chloride ion penetration at early ages, and the quantity of chloride ion around steel at later ages. Therefore, the in situ analysis of chloride ion penetration for marine concrete structures must be performed considering the cyclic humidity condition and the long term sorption.

사전 대비가 무엇보다 중요한 '여름철 안전관리' - 자연재해부터 인적재해까지 위험 가득

  • 대한산업안전협회
    • The Safety technology
    • /
    • no.187
    • /
    • pp.8-12
    • /
    • 2013
  • 기상이변으로 불리던 이상기후현상이 이제는 어느덧 일상화가 됐다. 100년만의 폭우, 동남아지역을 연상케 하는 습한 날씨 등이 수년째 반복되다 보니 더 이상 이를 놀랍게 여기지 않는 사람이 늘고 있는 것이다. 하지만 익숙하다고 이에 대한 대비를 소홀히 했다간 그야말로 큰 코를 다칠 수가 있다. 말 그대로 이상기후현상은 예측을 벗어난 이상 현상을 뜻하기 때문이다. 따라서 산업현장은 만약의 사태까지 염두에 두고 철저한 대비태세를 갖추고 있어야 한다. 여름철을 맞아 산업현장에서 꼭 유념해야할 안전관리 시항을 요약해 봤다.

  • PDF

노출평가를 위한 TLV 근거 - PHOSPHORUS OXYCHLORIDE (옥시 염화인)

  • Kim, Chi-Nyeon
    • 월간산업보건
    • /
    • s.382
    • /
    • pp.11-14
    • /
    • 2020
  • 눈, 피부 및 점막 자극의 가능성을 최소화하기 위해 옥시 염화인(phosphorus oxychloride)의 직업적 노출기준 TLV-TWA를 0.1ppm(0.63 mg/㎥)으로 권고하였다. 옥시 염화인 독성의 징후 및 증상으로는 두통, 현기증, 식욕 부진, 메스꺼움, 흉통 및 호흡 곤란이 있고 심한 급성 또는 반복 만성 노출에 의해서는 기관지 폐렴, 폐부종 그리고 신장 손상을 유발한다. 옥시 염화인은 물 또는 습한 공기에서 분해되어 염화수소와 인산을 형성한다. 피부, 감작제(SEN), 발암성 표기와 TLV-STEL을 권고하기에 충분한 자료가 없다.

  • PDF

Alignment change of lipid molecules in lipid bilayers by an antimicrobial peptide protegrin-1 (지질 이중막에 결합된 항균성 펩타이드 protegrin-1에 의한 지질 분자의 정열도 변화)

  • Kim, Chul
    • Analytical Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.106-111
    • /
    • 2015
  • Changes in antimicrobial peptide-lipid mixtures were investigated using 31P solid-state nuclear magnetic resonance spectroscopy. An antimicrobial peptide, protegrin-1, and phosphatidylcholine were deposited on a thin cover glass and incubated under a relative humidity of 95%. The changes in the mixtures were observed after hydration or air-drying. How repetitive hydration and drying changed the phase of the sample was also observed. The degrees of disruption of the well-aligned bilayers of phosphatidylcholine were determined quantitatively by simulating the experimental spectra. The peptide-lipid mixtures changed reversibly after hydration and drying, and the samples reached an equilibrium state after several repetitions.

Chloride Penetration into Concrete in Tidal Zone by Diffusion-Convection Analysis (확산과 이송을 고려한 콘크리트의 염소이온 침투해석)

  • Kim, Ki-Hyun;Cha, Soo-Won;Jung, Hyung-Mok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.6
    • /
    • pp.607-615
    • /
    • 2009
  • Analysis of chloride penetration into concrete is performed considering the repeated wetting and drying conditions of tidal zone, by means of the developed finite element program which enables the diffusion-convection analysis to be conducted. Heat conduction and moisture diffusion are also included in the finite element analysis program in order that their effects to chloride penetration may be considered. For the efficiency of calculation, the analyses of temperature, relative humidity and free chloride concentration are conducted successively in that order, by treating the convection of chloride due to moisture diffusion as an source or sink term. By comparing the analysis result from finite element analysis, where main variable is a wetting and drying period, with the chloride profiles from ACI Life-365 method, it is shown that the Life-365 method gives an accurate result for the submerged zone but does not consider the differences of wetting and drying period. To obtain an accurate chloride profile in the tidal zone, it is confirmed that the diffusion-convection finite element analysis should be applied.

Effects of Indoor Greening Method on Temperature, Relative Humidity and Particulate Matter Concentration (실내녹화 방법이 온·습도 및 미세먼지 농도에 미치는 영향)

  • Kwon, Kei-Jung;Park, Bong-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.4
    • /
    • pp.1-10
    • /
    • 2017
  • This study investigated indoor temperature and humidity control and PM1 and PM10 mitigation effects of a single green wall (Case 1), two green walls (Case 2), and two green walls plus a waterfall (Case 3) in comparison with a control without either a green wall or waterfall. Experiments were conducted in the office of Chungbuk National University from August to September, 2015. Experiments were carried out sequentially in the order of control, Case 1, Case 2, and Case 3. Data collected from August 17 to August 20, 2015 (Experiment 1), and from August 31 to September 3, 2015 (Experiment 2), when outdoor temperature was relatively constant, were analyzed. Plant volume ratios by indoor landscaping of the control, Case 1, Case 2 and Case 3 were 0.0, 0.6, 1.2, and 1.4%, respectively. Compared to the control, average temperatures of Case 1, Case 2 and Case 3 were decreased by 0.3~0.7, 0.7~0.9 and $1.0^{\circ}C$, respectively, and relative humidity was increased by 1.8~8.7, 9.2~14.6 and 14.8~21.9%, respectively. Three hundred minutes after exposure to mosquito repellent incense particles, the ratio of the remaining PM1 of the control, Case 1, Case 2 and Case 3 were 25.0, 22.0%, 21.2%, 17.3%, respectively, in Experiment 1 and 42.3, 28.9, 23.1, and 30.9%, respectively, in Experiment 2. As indoor greening increased the effect of indoor temperature, PM1 and PM10 mitigation were greater, and temperature and humidity were lower. The greater the relative humidity was, the faster PM1 and PM10 mitigation tended to be.

특집 2 - 환절기 사양관리 포인트 -환절기 육계 사양관리 중점 포인트 _환절기 스트레스를 줄이기위한 사양관리

  • Kim, Hui-Seong
    • KOREAN POULTRY JOURNAL
    • /
    • v.43 no.9
    • /
    • pp.122-125
    • /
    • 2011
  • 최근 4~5년 전부터 우리나라의 하절기 온도상황 및 호우 경향이 많이 달라지고 있다. 평년에 비해 6월 경 혹서기가 시작 되는가 하면, 지역별로 차이는 있으나 장마는 짧게 지나가고, 국지성 집중 호우 이후 혹서기가 반복되는 상황이다. 당연히 케이지 사육이 주로 이루어지는 산란계에 있어서는 습한 환경에 고온이 더해져 그 스트레스가 더욱 가중되어졌을 것으로 보인다. 이러한 부분은 섭취량 저하 및 생산성 저하로 연계되고, 질병 또한 평년에 비해 많이 발생하고 있다. 따라서 금번 환절기의 산란계는 혹서기로 인한 체력 저하 및 환경 적응력이 미진한 상황에서 일교차 증가와 온도 저하, 일조시간 변화 및 호르몬의 변화 등 다양한 스트레스에 직면하게 될 것으로 생각된다. 무엇보다 가을 환절기는 극심한 온도의 일교차 변화와 함께 시설과 농장환경에 따라 차이가 있겠지만 환기 부분에 있어서 기본적인 문제가 발생하게 되며, 특히 환기 부분은 겨울철로 향해 갈수록 관리가 어려워질 수밖에 없는 시점이다. 이러한 환경 변화에 따라 사료 섭취량 및 체내 영양소 균형과 대사과정에도 변화가 연계되면서 생산성의 저하, 면역력의 약화 및 활력의 저하가 동반되며 호흡기 및 다양한 질병(IB, ND, AI 등)이 발생될 가능성이 높아지게 된다. 따라서 이러한 상황에서 관리해야 할 몇 가지 주요 포인트를 점검해 보고자 한다.

Development of Simulation Model for Greenhouse Heating System Using Latent Heat Storage System (잠열축열을 이용한 그린하우스 난방시스템의 시뮬레이션 모델개발)

  • 노정근;송현갑
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.04b
    • /
    • pp.31-33
    • /
    • 2001
  • 잠열축열 그린하우스 난방 시스템의 난방특성을 분석하기 위하여 이에 대한 열평형 이론을 정립하고 수치해석에 의하여 컴퓨터 시뮬레이션 모델을 개발하고자 잠열축열 그린하우스 난방 시스템의 열저항 회로망을 구성하였다. 그리고 그린하우스의 피복재, 내부 공기, 토양표면, 잠열 축열재와의 열평형 방정식을 구성하였으며, Newton-Raphson반복법을 이용하여 수치해석을 하였고, 실험 분석을 통하여 수치해의 타당성을 검증하였다. 시뮬레이션 모델을 위하여 C언어를 사용하였으며, 겨울철 (11월-2월)의 기후 조건이 유사한 여러 날을 선정하여 온도, 태양강도, 상대습도, 토양 수분함량 등을 자료로 하여 모델링을 하였다. 여기에 사용된 토양 조건은 사양토로 건조한 상태를 유지하였다. 이상과 같은 분석에 의하여 그린하우스내 경시적 공기온도 변화와 열전달 현상의 실험치와 이론분석 결과가 잘 일치하고 있음을 알 수 있었다.

  • PDF

Interfacial Properties and Sensing of Carbon Nanofiber/Tube and Electrospun Nanofiber/Epoxy Composites Using Electrical Resistance Measurement and Micromechanical Technique (전기저항측정 및 미세역학시험법을 이용한 탄소나노섬유/튜브 및 전기방사된 나노섬유/에폭시 복합재료의 계면특성 및 감지능 연구)

  • Jung Jin-Gyu;Kim Sung-Ju;Park Joung-Man
    • Composites Research
    • /
    • v.18 no.4
    • /
    • pp.21-26
    • /
    • 2005
  • Nondestructive damage sensing and load transfer mechanisms of carbon nanotube (CNT) and nanofiber (CNF)/epoxy composites have been investigated by using electro-micromechanical technique. The electrospun PVDF nanofibers were also prepared as a piezoelectric sensor. The electro-micromechanical techniques were applied to evaluate sensing response of carbon nanocomposites by measuring electrical resistance under an uniform cyclic loading. Composites with higher volume content of CNT showed significantly higher tensile properties than neat and low volume$\%$ CNT composites. CNT composites showed humidity sensing within limited temperature range. CNT composites with smaller aspect ratio showed higher apparent modulus due to high volume content in case of shorter aspect ratio. Thermal treated electrospun PVDF nanofiber showed higher mechanical properties than the untreated case due to crystallinity increase, whereas load sensing decreased in heat treated case. Electrospun PVDF nanofiber web also showed sensing effect on humidity and temperature as well as stress transferring. Nanocomposites and electrospun PVDF nanofiber web can be applicable for sensing application.

Development of Chloride Penetration Analysis Program Considering Environmental Conditions (환경조건을 고려한 염소이온 침투해석 프로그램 개발)

  • Kim, Ki Hyun;Jang, Seung Yup;Cha, Soo Won;Chang, Sung Pil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.709-718
    • /
    • 2008
  • Developed is a chloride penetration analysis program in which changes of environmental conditions such as temperature, humidity and external chloride concentration, and the diffusion, convection and binding of chlorides are considered. In order to consider the changes of environmental conditions, analyses for temperature and moisture distribution are implemented simultaneously, and variation of diffusion coefficients due to temperature, humidity and age is also considered. By comparing the calculated total chloride contents with some experimental data, it has been confirmed that the proposed analysis program can trace measured chloride distribution well. Also, through some example analyses, the mechanism of accumulation of chlorides at near surface and acceleration of corrosion of steel reinforcement in case that the moisture distribution changes according to repeated drying and wetting cycles have been verified.