Purpose: This study was undertaken to investigate the feasibility of using automated liquid-handling systems equipped with reusable fixed tips in Radioimmunoassays and to demonstrate that the use of an automated pipetting instrument can decrease in the typical daily workload. Materials and Methods: The precisions of the automated pipettor and the manual pipettor were determined gravimetrically (n=30). A total of 30 specimens for HBs Ag were repeatedly pipetted (three replicates) with the automated pipettor and then retested. PSA samples were simultaneously pipetted with either the automated pipettor or the manual pipettor and then analyzed (n=40). Sample carryover test assessed for CA19-9, AFP and HCG when the automated pipettor was used. Pipetting speed of the automated pipettor and the manual pipettor were compared by evaluation of each workload. Results: The precisions coefficients of variation (CV) were 2.1% for the automated pipettor and 1.6% for manual pipettor. The mean cpm and CV for each group of replicates were 41,203 cpm and 3.7% for HBs Ag positive specimens, and 99 cpm and 7.9% for HBs Ag negative specimens, respectively. PSA results showed no significant differences between automated pipettor and manual pipettor (p=0.15, r=0.999). Carryover for CA19-9, AFP and HCG analytes was <0.1 ppm or below the assay limit of detection. Pipetting speed was significantly improved by using the automated instrument. Conclusion: There was no evidence that the use of an automated pipettor adversely affected any of the performance characteristics of the assay. Indeed, routine use of the Tecan automated pipettor has resulted in a decrease in the typical daily workload.
This study aims to analyze kinematic variables regarding lateral break-fall quantitatively that can protect the body, prevent the injury and minimize the impact. To this end, three Hapkido, judo athletes of H University with experience of over 5 years were selected. Test was conducted through three dimensional image analysis by checking the time and order the subjects reach a mat. In this study, lateral break-fall was repeated five times and among them, the best movement was selected. The picture shot with high-speed camera was analyzed by using KWON3D ver. 3.1 program through three dimensional coordinate calculation based on DLT method and smoothing process of data. Study results were as follows. 1. With respect to time variables shown in lateral break-fall of A, B, C athletes, there is small difference in temporal variables and in the order the body reaches a mat. With respect to average value, hand is ($0.94{\pm}0.20$), elbow ($0.97{\pm}0.17$), hip ($0.97{\pm}0.18$), back ($0.98{\pm}0.18$), and shoulder ($1.04{\pm}0.16$). Time variable the body reaches a mat in lateral break-fall is in hand, elbow, hip, back and shoulder. 2. With respect to moving distance variables shown in lateral break-fall of A, B, C athletes, hand is ($34.33{\pm}34.59$), elbow ($52.00{\pm}26.06$), hip ($70.00{\pm}15.72$), back ($153.67{\pm}17.93$), and should ($130.67{\pm}29.02$). The fact that this study contributed to improving security martial arts technique and protecting the body by understanding the principle of lateral break-fall movement is of significance. In addition, the fact that this study provided systematic basic data for improving security martial arts technique is significant.
The lab scale experiments to investigate the geochemical reaction among supercritical $CO_2$-mineral-brine which occurs at $CO_2$ sequestration sites were performed. High pressurized cell system (l00 bar and $50^{\circ}C$) was designed to create supercritical $CO_2$ in the cell, simulating the sub-surface $CO_2$ storage site. From the high pressurized cell experiment, the surface changes of Ca-feldspar, amphibole (tremolite) and olivine, resulted from the supercritical $CO_2$-mineral-brine reaction, were observed and the dissolution of minerals into the brine was also investigated. The mineral slabs were polished and three locations on the surface were randomly selected for the image analysis of SPM and the surface roughness value (SRV) of those locations were calculated to quantify the change of mineral surface for 30 days. At a certain time interval, SPM images and SRVs of the same mineral surface were acquired. The secondary minerals precipitated on the mineral surfaces were also analyzed on SEM/EDS after the experiment. From the experiments, the average SRV of Ca-feldspar increased from 2.77 nm to 20.87 nm for 30 days, suggesting that the dissolution of Ca-feldspar occurs in active when the feldspars contact with supercritical $CO_2$ and brine. For the amphibole, the average SRV increased from 2.54 nm to 8.31 nm and for the olivine from 0.77 nm to 11.03 run. For the Ca-feldspar, $Ca^{2+}$, $Na^+$, $Fe^{2+}$, $Si^{4+}$, $K^+$ and $Mg^{2+}$ were dissolved in the highest order and $Si^{4+}$, $Ca^{2+}$, $Fe^{2+}$ and $Mg^{2+}$ for the amphibole. Fe (or Mg) - oxides were precipitated as the secondary minerals on the surfaces of amphibole and olivine after 30 days reaction. Results suggested that $Ca^{2+}$, $Fe^{2+}$ and $Mg^{2+}$ rich minerals would be significantly weathered when it contacts with the supercritical $CO_2$ and brine at $CO_2$ sequestration sites.
Occurrence characteristics and existing forms of U-Th containing minerals in KURT (KAERI Underground Research Tunnel) granite are investigated to understand long-term behavior of radionuclides in granite considered as a candidate rock for the geological disposal of high-level radioactive waste. KURT granite primarily consists of quartz, feldspar and mica. zircon, REE(Rare Earth Element)-containing monazite and bastnaesite are also identified. Besides, secondary minerals such as sericite, microcline and chlorite including quartz vein and calcite vein are observed. These minerals are presumed to be accompanied by a post-hydrothermal process. U-Th containing minerals are mainly observed at the boundaries of quartz, feldspar and mica, mostly less than $30{\mu}m$ in size. Quantitative analysis results using EPMA (Electron Probe Micro-Analyzer) show that 74.2 ~ 96.5% of the U-Th containing minerals consist of $UO_2$ (3.39 ~ 33.19 wt.%), $ThO_2$ (41.61 ~ 50.24 wt.%) and $SiO_2$ (15.43 ~ 18.60 wt.%). Chemical structure of the minerals calculated using EPMA quantitative analysis shows that the U-Th minerals are silicate minerals determined as thorite and uranothorite. The U-Th containing silicate minerals are formed by a magmatic and hydrothermal process. Therefore, KURT granite formed by a magmatic differentiation is accompanied by an alteration and replacement owing to a hydrothermal process. U-Th containing silicate minerals in KURT granite are estimated to be recrystallized by geochemical factors and parameters such as temperature, pressure and pH owing to the hydrothermal process. By repeated dissolution/precipitation during the recrystallization process, U-Th containing silicate minerals such as thorite and uranothorite are formed according to the variation in the concentrated amount of U and Th.
The Journal of Korean Society for Radiation Therapy
/
v.17
no.2
/
pp.133-140
/
2005
Purpose : This test is designed to identify the validity of treatment plan by implementing real-time dosimetry by means of dose that is absorbed into PTV and OAR when preparing doses of 3D and POP plans. Materials and Methods : In treatment. error can be calculated be comparing Exp. Dose with the actual dose, which has been converted from 'the reading value obtained by placing diode detector on the area to be measured'. Same test can be repeated using Alderson-Rando phantom. Results : Errors were found: A patient(POP plan): 197.6/199=-1.2%, B patient(3D-plan): 199.9/198.7=+0.6%, C patient: 196/200=-1.5%. In addition, considering the resulted value of measuring OAR besides target-dose for C patient showed 96/200, representing does of 47%, the purpose of protection was judged to be duly accomplished. Also it was acknowledged the resulted value of -3.7% met the targeted dose within the range of ${\pm}5%$. Conclusion : Aimed for identifying the usefulness of pre-treatment dose measurement using diode detector, this test was useful to evaluate the validity of curing because it resulted in the identification of category to be protected as well as t dose. Moreover, it is thought to have great advantage in ascertaining the dose of target, dose of which is not calculated yet. Similar to L-gram before treatment, this test is thought to be very effective so that it can bring great advantages in the aspects such as validity of curing method and post-treatment plan as well.
Purpose : It is now well established that infection and inflammation play an important role in the pathogenesis of ischemic brain damage. The loss of neutrophils from systemic circulation is an associated finding in injury mediated by granulocyte. Periventricular leukomalacia(PVL) caused by ischemia is the principal form of brain injury in premature infants. This study was conducted to evaluate whether the low neutrophil count is associated with periventricular leukomalacia(PVL) in premature infants. Methods : Retrospective review of medical records was undertaken. Subjects were premature infants with a birth weight of less than 1,500 gm, admitted to the Neonatal Intensive Care Unit of Kyungpook University Hospital. A complete blood count of peripheral blood was done within the 1st hour of life. Neutropenia was defined as absolute neutrophil count < $1,500/mm^3$, PVL as increased periventricular echodensities followed by cyst formation on ultrasonography or corresponding signs on brain MRI. Results : Thirteen infants out of a total population of 37 revealed neutropenia. Respiratory distress syndrome and requirement for respiratory support were not different between infants with neutropenia( neutropenia group) and infants without neutropenia(control group). Intraventricular hemorrhage (IVH) and grade 3 and 4 IVH were more frequent in neutropenia group(P<0.05). There was no statistically significant increase of PVL in neutropenia group. The neutrophil count was $18,760.0{\pm}10,266.1/mm^3$, $7,272.0{\pm}7,435.0/mm^3$ infants with PVL and $11,131.7{\pm}3,386.5/mm^3$, $2,407.5{\pm}1,933.1/mm^3$ in infants without PVL, respectively. The frequency of mechanical ventilation and artificial surfactant therapy was higher in infants with PVL compared with infants without PVL, but statistical analysis was not performed due to small number of subjects. Conclusion : A low number of neutrophils in the systemic circulation was not associated with an increased risk of PVL in premature infants.
Kim, Eunhye;Hwang, Yon-Jin;Kim, Suhee;Lee, Hyeri;Hong, Soonsung;Park, Kyung-Hun;Kim, Jeong-Han
The Korean Journal of Pesticide Science
/
v.16
no.4
/
pp.343-349
/
2012
Exposure and risk assessments were conducted to evaluate the relative safety of mixing/loading work of indoxacarb between wettable powder (WP) and water dispersible granule (WG). Hand exposure was monitored using cotton gloves while inhalation exposure was measured using personal air monitor. Method validation for the exposure monitoring was established successfully through several experiments. Limit of determination and limit of quantitation were 0.25 and 1 ng, respectively. $R^2$ of calibration curve linearity was more than 0.9999 and reproducibility was 0.7-6. Recovery of indoxacarb from gloves, solid sorbent and glass fiber filter at three different levels was 81.5-108.8%. Trapping efficiency and breakthrough tests gave 981.5-108.8% of recovery. During mixing/loading procedure, hand exposure amount (75 percentile of 30 repetitions) for indoxacarb WP was 6 folds (459.8 mg/kg a.i) than that of WG (81.4 mg/kg a.i). This result indicates that WG has less drift than WP thanks to its granular type of formulation. Inhalation amount was $10^{-8}-10^{-7}%$ of spray mixture prepared and $10^{-4}-10^{-3}%$ of hand exposure. In inhalation case, no significant differences were observed between two formulations. Margin of safety was calculated for risk assessment using male Korean average body weight and acceptable operator exposure level as the important exposure factors. Mixing/loading procedures for both of the formulations were considered to be of least risk because calculated MOS values were more than 1.
[ $\underline{Purpose}$ ]: This study was to design and fabricate a phantom for prostate cancer brachytherapy to validate a developed program applying a 3-film technique, and to compare it with the conventional 2-film technique for determining the location of an implanted seed. $\underline{Materials\;and\;Methods}$: The images were obtained from overlapped seeds by randomly placing a maximum of 63 seeds in the anterior-posterior (AP) position and at $-30^{\circ} to $30^{\circ} at $15^{\circ} intervals. Images obtained by use of the phantom were applied to the image processing procedure, and were then processed into the development program for seed localization. In this study, cases were set where one seed overlapped, where two seeds overlapped and where none of the three views resolved all seeds. The distance between the centers of each seed to the reference seed was calculated in a prescribed region. This distance determined the location of each seed in a given band. The location of the overlapped seeds was compared with that of the 2-film technique. $\underline{Results}$: With this program, the detection rate was 92.2% (at ${\pm}15^{\circ}), 94.1% (at ${\pm}30^{\circ}) and 70.6% (compared to the use of the 2-film technique). The overlaps were caused by one or more than two seeds that overlapped; the developed program can identify the location of each seed perfectly. However, for the third case the program was not able to resolve the overlap of the seeds. $\underline{Conclusion}$: This program can be used to improve treatment outcome for the brachytherapy of prostate cancer by reducing the number of errors in the process of reconstructing the locations of perfectly overlapped seeds.
Purpose: As PET-MRI which has excellent soft tissue contrast is developed as integration system, many researches about clinical application are being conducted by comparing with existing display equipments. Because PET-MRI is actively used for head and neck cancer diagnosis in our hospital, lymph node metastasis before the patient's surgery was diagnosed and clinical usefulness of head and neck cancer PET-MRI scan was evaluated using pathological opinions and idiopathy surrounding tissue metastasis evaluation method. Materials and Methods: Targeting 100 head and neck cancer patients in SNUH from January to August in 2013. $^{18}F-FDG$ (5.18 MBq/kg) was intravenous injected and after 60 min of rest, torso (body TIM coil, Vibe-Dixon) and dedication (head-neck TIM coil, UTE, Dotarem injection) scans were conducted using $Bio-graph^{TM}$ mMR 3T (SIEMENS, Munich). Data were reorganized using iterative reconstruction and lymph node metastasis was read with Syngo.Via workstation. Subsequently, pathological observations and diagnosis before-and-after surgery were examined with integrated medical information system (EMR, best-care) in SNUH. Patient's diagnostic information was entered in each category of $2{\times}2$ decision matrix and was classified into true positive (TP), true negative (TN), false positive (FP) and false negative (FN). Based on these classified test results, sensitivity, specificity, accuracy, false negative and false positive rate were calculated. Results: In PET-MRI scan results of head and neck cancer patients, positive and negative cases of lymph node metastasis were 49 and 51 cases respectively and positive and negative lymph node metastasis through before-and-after surgery pathological results were 46 and 54 cases respectively. In both tests, TP which received positive lymph node metastasis were analyzed as 34 cases, FP which received positive lymph node metastasis in PET-MRI scan but received negative lymph node metastasis in pathological test were 4 cases, FN which received negative lymph node metastasis but received positive lymph node metastasis in pathological test was 1 case, and TN which received negative lymph node metastasis in both two tests were 50 cases. Based on these data, sensitivity in PET-MRI scan of head and neck cancer patient was identified to be 97.8%, specificity was 92.5%, accuracy was 95%, FN rate was 2.1% and FP rate was 7.00% respectively. Conclusion: PET-MRI which can apply the acquired functional information using high tissue contrast and various sequences was considered to be useful in determining the weapons before-and-after surgery in head and neck cancer diagnosis or in the evaluation of recurrence and remote detection of metastasis and uncertain idiopathy cervical lymph node metastasis. Additionally, clinical usefulness of PET-MRI through pathological test and integrated diagnosis and follow-up scan was considered to be sufficient as a standard diagnosis scan of head and neck cancer, and additional researches about the development of optimum MR sequence and clinical application are required.
In this study, the short-term variability of methane concentrations were investigated over 24-hr scale. The data obtained form the Moo-Ahn (MAN) station located in the western coastal area of Korea were analyzed from various respects to describe its distribution characteristics over short term scale. The MAN data were compared with those obtained from the two major background observatory sites: Point Barrow (Alaska) and Mauna Loa (Hawaii). The mean concentration of methane for the whole study period, when computed using the daily mean values, was found to be 1898${\pm}$85.3ppb (N=812). The mean values for the two comparable sites were observed to be 1832${\pm}$29.6ppb (N=823) for Point Barrow and 1745${\pm}$14.8ppb (N=818) for Mauna Loa. According to the analysis of frequency distribution. the mode value for the MAN area is found to be 1900ppb, but the mean concentration for Point Barrow and Mauna Loa are shown to have relatively low values of 1850 and 1750ppb, respectively. When examined over diurnal scale, the CH$_4$data for the MAN area exhibit a rather consistent trend; CH$_4$level is low during the daytime (after 6:00 A.M) and rises during the nighttime. The findings of the generally enhanced methane concentration in the MAN station may be explained form various respects. One of the most important reasons is that the MAN area is under the influence of various source processes relative to all the other stations under consideration. The short-term distribution patterns for the MAN station are hence characterized not only by the high methane concentration but also by the high oscillation in its CH$_4$concentration level.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.