• Title/Summary/Keyword: 반밀폐

Search Result 62, Processing Time 0.036 seconds

Risk analysis of flammable range according to hydrogen vehicle leakage scenario in road tunnel (도로터널 내 수소차 누출시나리오에 따른 가연영역에 대한 위험성분석 연구)

  • Lee, Hu-Yeong;Ryu, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.4
    • /
    • pp.305-316
    • /
    • 2022
  • Hydrogen energy is emerging as an alternative to the depletion of fossil fuels and environmental problems, and the use of hydrogen vehicles is increasing in the automobile industry as well. However, since hydrogen has a wide flammability limit of 4 to 75%, there is a high concern about safety in case of a hydrogen car accident. In particular, in semi-enclosed spaces such as tunnels and underground parking lots, a fire or explosion accompanied by hydrogen leakage is highly likely to cause a major accident. Therefore, it is necessary to review hydrogen safety through analysis of flammability areas caused by hydrogen leakage. Therefore, in this study, the effect of the air velocity in the tunnel on the flammability area was investigated by analyzing the hydrogen concentration according to the hydrogen leakage conditions of hydrogen vehicles and the air velocity in the tunnel in a road tunnel with standard section. Hydrogen leakage conditions were set as one tank leaking and three tanks leaking through the TPRD at the same time and a condition in which a large crack occurred and leaked. And the air velocity in the tunnel were considered 0, 1, 2.5, and 4.0 m/s. As a result of the analysis of the flammability area, it is shown that when the air velocity of 1 m/s or more exists, it is reduced by up to 25% compared to the case of air velocity of 0 m/s. But there is little effect of reducing the flammability area according to the increase of the wind speed. In particular, when a large crack occurs and completely leaks in about 2.5 seconds, the flammability area slightly increases as the air velocity increases. It was found that in the case of downward ejection, hydrogen gas remains under the vehicle for a considerably long time.

Comparison of Measured and Calculated Carboxylation Rate, Electron Transfer Rate and Photosynthesis Rate Response to Different Light Intensity and Leaf Temperature in Semi-closed Greenhouse with Carbon Dioxide Fertilization for Tomato Cultivation (반밀폐형 온실 내에서 탄산가스 시비에 따른 광강도와 엽온에 반응한 토마토 잎의 최대 카복실화율, 전자전달율 및 광합성율 실측값과 모델링 방정식에 의한 예측값의 비교)

  • Choi, Eun-Young;Jeong, Young-Ae;An, Seung-Hyun;Jang, Dong-Cheol;Kim, Dae-Hyun;Lee, Dong-Soo;Kwon, Jin-Kyung;Woo, Young-Hoe
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.401-409
    • /
    • 2021
  • This study aimed to estimate the photosynthetic capacity of tomato plants grown in a semi-closed greenhouse using temperature response models of plant photosynthesis by calculating the ribulose 1,5-bisphosphate carboxylase/oxygenase maximum carboxylation rate (Vcmax), maximum electron transport rate (Jmax), thermal breakdown (high-temperature inhibition), and leaf respiration to predict the optimal conditions of the CO2-controlled greenhouse, for maximizing the photosynthetic rate. Gas exchange measurements for the A-Ci curve response to CO2 level with different light intensities {PAR (Photosynthetically Active Radiation) 200µmol·m-2·s-1 to 1500µmol·m-2·s-1} and leaf temperatures (20℃ to 35℃) were conducted with a portable infrared gas analyzer system. Arrhenius function, net CO2 assimilation (An), thermal breakdown, and daylight leaf respiration (Rd) were also calculated using the modeling equation. Estimated Jmax, An, Arrhenius function value, and thermal breakdown decreased in response to increased leaf temperature (> 30℃), and the optimum leaf temperature for the estimated Jmax was 30℃. The CO2 saturation point of the fifth leaf from the apical region was reached at 600ppm for 200 and 400µmol·m-2·s-1 of PAR, at 800ppm for 600 and 800µmol·m-2·s-1 of PAR, at 1000ppm for 1000µmol of PAR, and at 1500ppm for 1200 and 1500µmol·m-2·s-1 of PAR levels. The results suggest that the optimal conditions of CO2 concentration can be determined, using the photosynthetic model equation, to improve the photosynthetic rates of fruit vegetables grown in greenhouses.

Measurement of $\textrm{CO}_2$ Concentration and Leaf Area Index for Crop Photosynthesis Model in Sweet Pepper (단고추의 작물 광합성 모델을 위한 $\textrm{CO}_2$ 농도와 엽면적지 수 측정)

  • Lee, Beom-Seon;Chung, Soon-Ju;Jang, Hong-Gi
    • Journal of Bio-Environment Control
    • /
    • v.8 no.3
    • /
    • pp.192-201
    • /
    • 1999
  • This study was aimed to introduce the measurement of $CO_2$ concentration and leaf area index in the phytotron for predicting the effect of CO.E, light and leaf area index on the instantaneous photosynthetic rate of sweet pepper with the existing ASKAM model. Measurements were made in 2 semi-closed phytotron compartments in which three different $CO_2$ concentrations were applied at random. Plants were grown on containers with circulating nutrient solution at 21$^{\circ}C$ and 80-95% relative humidity. The model estimates crop net $CO_2$ uptake for short time intervals during the day based on short-term data of daily radiation, temperature and $CO_2$ concentration. During the photosynthesis measurements, $CO_2$ concentrations in both compartments and in the basement were measured every minute. This was also done for the flow of pure $CO_2$ into the compartment, global radiation, photosynthetic active radiation inside the compartment, temperature and relative humidity. Crop growth models summarize our knowledge on crop behavior and have as such a wide range of applications in analysis, crop management and thus as a farm management tool.

  • PDF

A study on the smoke control performance of the damper exhaust system at FCEV fire in tunnel for small vehicles (소형차 전용터널 내 수소연료전지차 화재시 집중배기방식의 제연성능에 관한 연구)

  • Hong, Seo-Hee;Baek, Doo-San
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.745-756
    • /
    • 2022
  • The road tunnel is a semi-closed space that is blocked on all sides except the entrance and exit, and in the event of a fire, the smoke of the fire spreads longitudinally due to heat buoyancy caused by the fire and air currents that always exist in the tunnel. To solve this problem, smoke removal facilities are installed in road tunnels to secure a safe evacuation environment by controlling the direction of movement of smoke or directly smoking at fire points. In urban areas, the service level of urban roads decreases due to the increase in traffic due to the increase in population, and as a solution, the construction of underground roads in urban areas is increasing. When a fire occurs during hydrogen leakage through TPRD of a hydrogen fuel cell vehicle (FCEV), the fire intensity depends on the amount of leakage, and the maximum fire intensity depends on the orifice diameter of the TPRD. Considering the TPRD orifice diameter of 1.8 mm, this study analyzed the diffusion distance of fire smoke according to the wind speed of the roadway and the opening interval of the large exhaust port when the maximum fire intensity was 15 MW. As a result, it was analyzed that air flow in the tunnel could be controlled if the wind speed of the road in the tunnel was less than 1.25 m/s, and smoke could be controlled within 200 m from the fire if the damper interval was 50 m and 100 m.

A basic study on the hazard of hydrogen feul cell vehicles in road tunnels (도로터널에서 수소차 위험에 관한 기초적 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.1
    • /
    • pp.47-60
    • /
    • 2021
  • Hydrogen is a next-generation energy source, and according to the roadmap for activating the hydrogen economy, it is expected that industries to stably produce, store, and transport of hydrogen as well as the supply of hydrogen fuel cell vehicles will be made rapidly. Accordingly, safety measures for accidents of hydrogen vehicles in confined spaces such as tunnels are required. In this study, as part of a study to ensure the safety of hydrogen fuel cell vehicles in road tunnels, a basic investigation and research on the risk of fire and explosion due to gas leakage and hydrogen tank rupture among various hazards caused by hydrogen fuel cell vehicle accidents in tunnels was conducted. The following results were obtained. In the event of hydrogen fuel cell vehicle accidents, the gas release rate depends on the orifice diameter of TPRD, and when the gas is ignited, the maximum heat release rate reaches 3.22~51.36 MW (orifice diameter: 1~4 mm) depending on the orifice diameter but the duration times are short. Therefore, it was analyzed that there was little increase in risk due to fire. As the overpressure of the gas explosion was calculated by the equivalent TNT method, in the case of yield of VCE of 0.2 is applied, the safety threshold distance is analyzed to be about 35 m, and number of the equivalent fatalities are conservatively predicted to reach tens of people.

A basic study for explosion pressure prediction of hydrogen fuel vehicle hydrogen tanks in underground parking lot (지하주차장 수소연료차 수소탱크 폭발 압력 예측을 위한 기초 연구)

  • Lee, Ho-Hyung;Kim, Hyo-Gyu;Yoo, Ji-Oh;Lee, Hu-Yeong;Kwon, Oh-Seung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.605-612
    • /
    • 2021
  • Amid growing global damage due to abnormal weather caused by global warming, the introduction of eco-friendly cars is accelerating to reduce greenhouse gas emissions from internal combustion engines. Accordingly, many studies are being conducted in each country to prepare for the explosion of hydrogen fuel in semi-closed spaces such as tunnels and underground parking lots to ensure the safety of hydrogen-electric vehicles. As a result of predicting the explosion pressure of the hydrogen tank using the equivalent TNT model, it was found to be about 1.12 times and 2.30 times higher at a height of 1.5 meters, respectively, based on the case of 52 liters of hydrogen capacity. A review of the impact on the human body and buildings by converting the predicted maximum explosive pressure into the amount of impact predicted that all predicted values would result in lung damage or severe partial destruction. The predicted degree of damage was applied only by converting the amount of impact caused by the explosion, and considering the additional damage caused by the explosion, it is believed that the actual damage will increase further and safety and disaster prevention measures should be taken.

Occurrence of White Rust and Growth of Chrysanthemum 'Baekma' by Control of Relative Humidity with Night Ventilation and Heating in the Greenhouse (국화 '백마'의 시설재배에서 야간 환기와 난방에 의한 상대습도 조절에 따른 흰녹병 발생과 생육)

  • Yoo, Yong Kweon;Roh, Yong Seung;Nam, Byung Cheol
    • Horticultural Science & Technology
    • /
    • v.34 no.6
    • /
    • pp.845-859
    • /
    • 2016
  • This study was conducted to examine the effect of nighttime ventilation and heating on changes in temperature and humidity, the occurrence of white rust, and growth of standard chrysanthemum (Dendranthema grandiflorum) 'Baekma' in a greenhouse. For the ventilation treatments, the mean nighttime humidity in the control greenhouse, which had a closed side window, was higher (94.5%), but the humidity in the natural and natural+fan ventilation treatments was lower (74.3% and 72.8%, respectively). The rate of occurrence of white rust at 34 days after treatment was 100, 98.3, 75.6, and 43.3% for the control, fan ventilation, natural ventilation, and natural+fan ventilation treatments, respectively. The number of infected leaves and telia were the lowest in the natural+fan ventilation treatment compared with the other treatments. The growth of the chrysanthemum 'Baekma' was significantly suppressed in the control because of the occurrence of white rust and high humidity, while plant height, number of leaves, stem diameter, and fresh weight were the greatest in the natural+fan ventilation treatment. For the heating treatments, the mean nighttime temperature of the control (RH 95% heating), which was heating and held at 95% humidity, was $18.4^{\circ}C$, while the temperature of the heating treatment, which was held at 70% relative humidity (RH 70% heating) was $25.8^{\circ}C$. The rate of occurrence of white rust (34.4%), number of infected leaves (0.9), and telia (1.0) were the lowest in the RH 70% heating treatment compared with the other heating conditions. Also, the RH 70% heating treatment showed the best growth in terms of plant height, stem diameter, number of leaves, and fresh weight. Therefore, the natural+fan ventilation and RH 70% heating treatments were effective for the control of white rust and the growth of standard chrysanthemum 'Baekma' in a greenhouse.

Propagation Efficiencies at Different LED Light Qualities for Leaf Cutting of Six Echeveria Cultivars in a Plant Factory System (에케베리아 6품종의 엽삽 시 식물공장시스템 내 LED 파장에 따른 번식 효율)

  • Kim, Seongmin;Kim, Jiseon;Oh, Wook
    • Journal of Bio-Environment Control
    • /
    • v.27 no.4
    • /
    • pp.363-370
    • /
    • 2018
  • The succulent plants of Echeveria genus are in increasing demand worldwide, but it is difficult to supply good quality young plants throughout the year because propagation efficiencies are depend on cultivar and environmental factors. This study was carried out to investigate the propagation efficiencies of leaf cutting in Echeveria cultivars at different LED light qualities in a closed-type plant factory system. Leaf cuttings cut from stock plants of six difficult-to-propagated cultivars 'Afterglow (AG)', 'Berkeley Light (BL)', 'Mason (MS)', 'Subsessilis Light (SL)', 'Cream Tea (CT)', and 'Ben Badis (BB)' were put into cutting media in the plant factory system maintained at a temperature of $24{\pm}2^{\circ}C$ and relative humidity of $60{\pm}10%$, and watered with over-head irrigation twice a week. Cuttings were irradiated with sole or mixed red (R, 660 nm), blue (B, 450 nm), green (G, 530 nm), and far-red (FR, 730 nm) LEDs as follows: R10, R8+B2, R5+B5, R7+B2+FR1, and R7+B2+G1. PPFD just above the cuttings was $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ and photoperiod was 16/8 (light/dark) hours. As a result, propagation efficiencies were dependent on cultivar. Rooting and shooting were relatively easy in 'SL' but shoot formation in 'AG' was very difficult. Light qualities from LEDs also affected plant regeneration. Light conditions with a higher ratio of B, R5+B5, R7+B2+FR1, and R7+B2+G1, promoted shoot formation and growth but inhibited rooting and root growth. R10 and R8+B2 with a higher ratio of R promoted rooting and root growth and inhibited shoot formation and growth of cuttings. In addition, the treatment with FR increased leaf size and biomass of the all plants. Therefore, further studies are needed to investigate the optimum compositions of LED light quality for the improvement of leaf cutting efficiency in difficultto-propagated Echeveria cultivars.

Effects of Packing Materials, tight Condition and Storage Temperature on MAP Storage of Chicon (MAP저장시 포장재 종류, 광의 유무, 및 저장온도가 치콘 저장성에 미치는 영향)

  • Bae Jong Hyang;Park Kuen Woo;Kang Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.14 no.2
    • /
    • pp.69-75
    • /
    • 2005
  • The storability of chicon was compared by packing it with PE box, wrap, LDPE (low density polyethylene) film that was 25 and 50um thickness, respectively and storing at 1 and $10^{\circ}C$ under light and dark conditions. The visual quality depending on dehydration was deteriorated at more than $2\%$ weight loss during storage. In packing treatments, chicon packed with PE box lost fresh weight to $3\%\;at\;10^{\circ}C\;and\;2\%\;at\;1^{\circ}C$, while non- penetrated film treatment, wrap, 25 and 50um thickness LDPE film, showed less than $1\%$ weight loss. The carbon dioxide concentration in package was $3\~4\%\;in\;50{\mu}m$ LDPE film at $1^{\circ}C\; and\;25um$ LDPE film at $10^{\circ}C$. The ethylene concentration in 50um LDPE film at $1^{\circ}C\;and\;25{\mu}m$ LDPE film at $10^{\circ}C$ was approximately 0.3 ppm and 0.5 ppm, respectively. Chiton stored in dark condition didn't turn to green, but it fumed green only in 3 days at $10^{\circ}C$ and in 6 days at $1^{\circ}C$ under light condition. The greening of chicon was less, the packing materials was thicker. The chlorophyll content represented the degree of greening showed less at $1^{\circ}C$ then at $10^{\circ}C$. The coefficient of correlation(r) between chlorophyll content and carbon dioxide concentration in package was 0.926 at $1^{\circ}C$ and 0.997 at $10^{\circ}C$. The visual quality except greening of packed chicon was maintained at $1^{\circ}C$ better than $10^{\circ}C$, and it was shown highest grade packed with $50{\mu}m$ LDPE film at $1^{\circ}C$ and packed with 25um LDPE film at $10^{\circ}C$. The vitamin C content in packed chicon was kept higher at $1^{\circ}C$ on storage temperatures, and 25um and 50um LDPE film on packing materials. According to these results, it can be proper condition for storage and marketing of chicon that 50um LDPE film at $1^{\circ}C$ and 25um LDPE film at $10^{\circ}C$. And dark condition is necessary to store chicon because it should turn green under tiny light condition.

New Perspectives on Sunday School of Korean Church for Next Generation (다음 세대와 한국교회 주일학교의 새 전망)

  • Kim, Jeong Joon
    • Journal of Christian Education in Korea
    • /
    • v.67
    • /
    • pp.11-44
    • /
    • 2021
  • In the early 21st century, the global COVID-19 pandemic, which has arisen during the development of the technological science of the Fourth Industrial Revolution, has been a great challenge in all fields including politics, economy, industry, education and religion in Korean society. To prevent the spread of the COVID-19 epidemic, the Korean government announced 'social distancing guidelines,' focused on the 'prohibition of three conditions'(crowd, closeness, airtight) for safety reasons. These quarantine guidelines made it more difficult for Korean churches and Sunday schools to operate. In general, looking at the statistical data of the major denominations of the Korean Church in the second half of the 20th century, shows that the Church has entered a period of stagnant or declining growth. Data also show that the number of students attending Sunday School is decreasing. The researcher identified four causes of the crisis faced by the Korean church and Korean Sunday school entering the 21st century. These trends are influenced by the tendencies of postmodernism, the deconstruction of modern universalism, the certainty and objectivity of knowledge, and the grand narrative and worldview of diffusion. Moreover, it is a phenomenon in which the young population decreases in contrast to the increasing elderly population in the age of population cliff in Korean society. Sunday Schools are also facing a crisis, as the youth population, who will become the future heroes of the Korean church, is declining. Finally, constraints of Church and Sunday school education activities are due to COVID-19 Pandemic. As analysis shows the loss of the Church's educational vision and a decrease in the passion for education. Accordingly, the researcher suggests four new strategies for the next generation of Korean Sunday schools, whose ranges from 200 members or less; this range covers the majority of Sunday School program run by churches in Korea. First, in the age of postmodernism, a time of uncertainty and relativism, Christian Societies requires teachers who are certain of absolute Christian truth and faith. Second, in an era of declining population cliffs for younger generations, a shift to a home-friendly Sunday school paradigm is needed. Third, during the COVID-19 pandemic, educational activities must appropriately utilize face-to-face and non-face-to-face communication. Finally, even in difficult times, Korean Sunday school should nevertheless remember the Lord's great commandment(Matthew 28:18-20) and restore the vision and passion of education to announce and teach the gospel. The researcher hopes that this study will provide small, positive steps in rebuilding Korean Sunday school educational activities for future generations in difficult times.