• Title/Summary/Keyword: 박정수

Search Result 1,217, Processing Time 0.027 seconds

Numerical investigation of gaseous detonation observed in the elasto-plastic metal tubes (탄소성 금속관 내 가스 폭굉의 수치적 연구)

  • Gwak, Min-cheol;Do, Yeong-dea;Park, Jeong-su;Yoh, Jai-ick
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.85-87
    • /
    • 2012
  • We present a numerical investigation on gaseous (ethylene-air mixture) detonation in the elastoplastical metal tubes to understand the wall effects associated with the developing detonation instability. The acoustic disturbances originating from the rapidly expanding tube walls reach the detonating flame surface, thereby causing flame distortions and total energy losses. The compressible Navier-Stokes equations with equation of state for gas and elasto-plastic deformation field equations for inert tubes are solved simultaneously to understand the complex multi-material interaction in the rapidly expanding gas pipe. In order to track governing variables across the material interface, we use the hybrid particle level-set and ghost fluid methods to precisely estimate the interfacial quantities. Features observed from the deforming (thin) tube show substantially different behavior when a detonation propagates in the rigid (thick) tube with no acoustically responding wall conditions.

  • PDF

A Study on the Dynamic Stability Analysis of Power System with Multi-VSI type FACTS Devices using the Current Injection Method (전류 주입형 기법을 이용한 복수의 전압원 FACTS 기기들이 설치된 계통의 동적 안정도 해석에 대한 연구)

  • Park, Jung-Soo;Jang, Gil-Soo;Son, Kwang-M.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.198-199
    • /
    • 2006
  • FACTS(Flexible AC Transmission System) 기기들은 전력계통의 경제적이고 안정적인 운용과 제어에 더 많은 유연성을 제공할 수 있다. 그러나 이러한 FACTS 기기들은 기존의 전력 계통 설비들과는 달리 그 특성이 매우 비선형적이고 복잡하기 때문에 기존 전력 계통의 동적 시뮬레이션 알고리즘에 적용시키는 것이 매우 어렵다. 이러한 어려움을 해결하기 위하여 전압원 인버터(Voltage Sourced Inverter) 형태의 FACTS 기기를 병렬 형태로 주입되는 전류로 등가화 하여 기존의 시뮬레이션 알고리즘에 적용하는 방법이 제안되었다. 본 논문에서는 이 전류 주입형 기법을 이용하여 다수의 FACTS 기기들이 설치된 계통의 동적 안정도 해석 방법을 제안한다. 제안된 방법은 서로 다른 형태의 FACTS 기기들이 설치된 경우에도 적용될 수 있으며 이를 이용하여 서로 다른 FACTS 모델들 간의 조합에 의한 계통의 안정도 변화를 사례연구를 통하여 보일 것이다.

  • PDF

Modeling of Unified Power Flow Controllers Using a Current Injection Method for Transient Stability Analysis (전류 주입형 방식의 UPFC 모델을 이용한 과도 안정도 해석)

  • Kim, Chon-Hoe;Park, Jung-Soo;Jang, Gil-Soo;Son, Kwang-M.;Kim, Tae-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.332-334
    • /
    • 2005
  • This paper presents a dynamic simulation of the unified power flow controller (UPFC) using a current injection method. Flexible AC Transmission System (FACTS) devices give more flexibility of control for security and economic operation of power systems. Diffculties of modeling UPFC in the conventional dynamic simulation programs arise from the fact that the injected voltage by the series inverter is superimposed on the shunt inverter side voltage. A solution can be a current injection method, in which a serial part of UPFC is converted to a parallel equivalent circuit using source transformation, and two current sources affect each other at every time step. To verify efficiency of this method, the proposed model is applied for the transient analysis of an example power system.

  • PDF

Development of Transient Stability Analysis Program for KEPCO System (한전 실 계통의 상정사고 모의가 가능한 과도 안정도 해석 프로그램 개발)

  • Park, Jung-Soo;Jang, Gil-Soo;Shin, Jeong-Hoon;Kim, Tae-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.414-416
    • /
    • 2006
  • 경쟁적 전력 환경 하에서 계통해석은 신뢰성과 객관성을 전제로 수행되어야 하며, 이를 위해서는 계통해석 시 정확한 데이터를 사용하는 것뿐만 아니라, 계통의 특성에 맞는 적합한 계통해석 툴을 사용하는 것이 중요하다. 그러나 현재 과도안정도 해석에 있어 국내 에서는 해외에서 개발된 상용 패키지를 주로 사용하고 있으며, 전적으로 해외 상용 프로그램을 이용한 해석에 의존하고 있다. 따라서 우리나라의 전력계통에서 발생하는 다양한 현상을 종합해석 할 수 있는 프로그램을 개발, 한전, 한국전력거래소, 발전회사, 연구소 및 학계가 공히 사용함으로써, 전력계통 해석 결과의 신뢰도를 제고할 필요가 있다. 이러한 요구에 의하여 국내 전력계통에 대하여 보다 효율적인 과도 안정도 해석이 가능한 프로그램을 개발하였다.

  • PDF

Trend analysis and wavelet transform of time series of precipitation including the Chukwookee observation in Seoul (측우기 자료를 포함한 서울 강수량 시계열에 대한 추세분석 및 파엽분석)

  • 정현숙;박정수;임규호;오재호
    • The Korean Journal of Applied Statistics
    • /
    • v.13 no.2
    • /
    • pp.525-540
    • /
    • 2000
  • Characteristics of precipitation in Seoul have been examined by using long-term observational data. Precipitation records from modern rain gauges were used for 1908-1996, together with the traditional Korean rain gauge (called Chukwookee) observations for 1777-1907. A linear trend analysis of seasonal total rainfall shows no significant trends over the last 200 years A wavelet transform analysis was performed to figure out the transient variations of precipitation.

  • PDF

라틴-하이퍼큐브 실험게획 간의 거리 계산과 비교

  • 박정수;황현식
    • The Korean Journal of Applied Statistics
    • /
    • v.13 no.2
    • /
    • pp.477-488
    • /
    • 2000
  • A distance measure between two Latin-hypercube designs is defined and its expected value is computed. It was computed by using mathematical statistics, numerical analysis (multidimensional numerical integration), Monte-carlo method, and the theory of asymptotic normal distribution. For the comparison of two Latin-hypercube designs with same structure but different randomness, the difference of expected values of response function and information mass of experimental designs are considered. These methods may be useful in comparison between two general experimental designs.

  • PDF

Optimization of intermediate cooling in conduction-cooled cryostat (전도냉각형 저온용기에서 중간냉각의 최적화)

  • 장호명;박정수;김성래;김형진;진홍범;이봉근
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.155-158
    • /
    • 2001
  • An intermediate cooling is indispensible to reduce the refrigeration power at superconducting system that is cooled conductively by a cryocooler without liquid cryogens. The cooling load at the intermediate stage is caused by the mechanical supports, the radiation shield and the current lead. From the cooling load calculation, a thermodynamic analysis that take into account the temperature-dependent properties of the materials and the actual performance of the cryocooler is developed. For any given physical dimensions of the various components, it is shown that there exist a unique optimum for the intermediate temperature to minimize the overall refrigeration power. The results of this study can be usefully applied to the selection of the cryocooler as well as the design of the conduction-cooled cryostat.

  • PDF

Dry Etching Characteristic of TiN Thin Films using Inductively Coupled Plasma (TiN 박막의 건식 식각 특성)

  • Park, Jung-Soo;Kim, Chang-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.383-383
    • /
    • 2010
  • TiN is one of the mostly used barrier materials in copper metallization because of low friction coefficient and superior electrical properties. We need to investigate for the etching characteristic of TiN. In this study, we investigated about etching characteristic of TiN using $BCl_3$/Ar inductively coupled plasma system. The etch rate was measured by a depth pro filer. The chemical etching reactions of the TiN surface was investigated X-ray photoelectron spectroscopy.

  • PDF

Hemodynamic Analysis of Pig's Left Common Coronary Artery (I) (좌주간부 관상동맥에 관한 혈류역학적 분석 (I))

  • Park, Jung-Su;Chang, Ju-Hee;Moon, Su-Yeon;Shin, Se-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1923-1929
    • /
    • 2003
  • The present study investigated the microcirculation of blood in the left common artery (LCCA). In order to develop a mathematical model for microcirculation in LCCA, the present study adopted preexisted set of measured morphological data on anatomy, mechanical properties of the coronary vessels, viscosity of blood, the basic laws of physics, and the appropriate boundary conditions. In this study, the statistical distribution of blood pressure, blood flow, and blood volume in the LCCA were determined based on the anatomical branching pattern of the coronary arterial tree and the statistical data of blood vessel dimensions. Our calculations were in good agreement with the previous studies. The present results showed that the mean longitudinal pressure drop profile was function of the vessel order numbers. It was found that the normalized pressure drop was a logarithmic function of the compliance.

  • PDF

Hemodynamic Analysis of Pig's Left Common Coronary Artery (LCCA) (II) (좌주간부 관상동맥(LCCA)에 관한 혈류역학적 분석 (II))

  • Moon, Su-Yeon;Jang, Ju-Hee;Park, Jung-Su;Shin, Seh-Yun
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2043-2047
    • /
    • 2003
  • The distributions of blood pressure, blood flow, and blow volume in the left common artery (LCCA) were determined using the lumping parameter method. In order to develop a mathematical model for microcirculation in LCCA, the present study adopted preexisted set of measured morphological data on anatomy, mechanical properties of the coronary vessels, viscosity of blood, the basic laws of physics, and the appropriate boundary condition. Pressures and volumes of blood and flow resistance were expressed in terms of electrical voltages, current, and resistances, respectively, in the electrical analog model. The results of two mathematical models, symmetrical and asymmetrical models, were compared with other investigator's data. The present results were in good agreement with previous studies. It was found that the mean pressure profiles were similar in both models.

  • PDF