• Title/Summary/Keyword: 박리 주파수

Search Result 33, Processing Time 0.017 seconds

NDE of the Internal Hole Defect of Dental Composite Restoration Using Infrared Lock-In Thermography (위상잠금 열화상기법을 이용한 치과용 복합레진 수복재의 내부 홀 결함에 대한 비파괴평가)

  • Gu, Ja-Uk;Choi, Nak-Sam
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.40-45
    • /
    • 2013
  • The purpose of this study was to detect the pin hole defect of dental composite restoration using lock-in thermography method. Amplitude and phase images of the composite resin specimens were analyzed according to the lock-in frequency and the diameter of defect area. Through the amplitude image analysis, at lock-in frequency of 0.05 Hz, defect diameters 2-5 mm exhibited the highest amplitude contrast value between defective area and sound area. The lock-in frequency range of 0.3-0.5 Hz provided good phase angle contrast for the defect area. At lock-in frequency range of 0.5 Hz, defect diameter of 5 mm exhibited the highest phase contrast value. It is concluded that the infrared lock-in thermography method verified the effectiveness for detecting the pin hole defect of dental composite restoration.

A Brazing Defect Detection Using an Ultrasonic Infrared Imaging Inspection (초음파 열 영상 검사를 이용한 브레이징 접합 결함 검출)

  • Cho, Jai-Wan;Choi, Young-Soo;Jung, Seung-Ho;Jung, Hyun-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.426-431
    • /
    • 2007
  • When a high-energy ultrasound propagates through a solid body that contains a crack or a delamination, the two faces of the defect do not ordinarily vibrate in unison, and dissipative phenomena such as friction, rubbing and clapping between the faces will convert some of the vibrational energy to heat. By combining this heating effect with infrared imaging, one can detect a subsurface defect in material in real time. In this paper a realtime detection of the brazing defect of thin Inconel plates using the UIR (ultrasonic infrared imaging) technology is described. A low frequency (23 kHz) ultrasonic transducer was used to infuse the welded Inconel plates with a short pulse of sound for 280 ms. The ultrasonic source has a maximum power of 2 kW. The surface temperature of the area under inspection is imaged by an infrared camera that is coupled to a fast frame grabber in a computer. The hot spots, which are a small area around the bound between the two faces of the Inconel plates near the defective brazing point and heated up highly, are observed. And the weak thermal signal is observed at the defect position of brazed plate also. Using the image processing technology such as background subtraction average and image enhancement using histogram equalization, the position of defective brazing regions in the thin Inconel plates can be located certainly.

Recent Perspectives on Oncoplastic Breast Surgery in Korea (우리나라의 종양성형학적 유방암 수술에 대한 최신 동향)

  • Kang, Taewoo
    • Journal of Life Science
    • /
    • v.30 no.6
    • /
    • pp.563-569
    • /
    • 2020
  • Oncoplastic surgery (OPS) combines oncologically safe tumor resection with aesthetically satisfying reconstruction of defects using established plastic surgery techniques. OPS is characterized by initial excision as extensive as is beneficial for oncological safety, and, once sufficient resection is complete, displacement or replacement techniques are selected based on remnant volume. The size of the lesion and the individual patient are important factors when considering the appropriate approach, and when pre-operative imaging, including MRI, is used to determine the technique, the complete removal of cancer cells by permanent pathology is essential. A frozen section is used during the operation to reduce the reoperation rate, but it is difficult to cover the entire margin surface theoretically and even harder in practice. A recent report about adequate margins has empowered OPS in its oncological safety. Considering the patients to whom each modality could be applied, basic breast volume is an important factor, and this is influenced by ethnic differences. In Europe or the US, for example, the average breast size is 36D (600 ㎤) and reduction mammoplasty is predominantly used. However, the average size of patients in our institution is 33A (300 ㎤), and so quite different approaches are selected in most cases. New techniques involving radiofrequency and fluorescence have been proposed as safe and easily accessible ways of reducing complications.