• Title/Summary/Keyword: 바탕체 9pt

Search Result 6, Processing Time 0.028 seconds

The Study for Impact Strength change of Microcellular foamed Recycled ABS (초미세 발포 플라스틱의 재생 후 강도변화에 대한 연구)

  • 성갑제;차성운;윤재동
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.896-899
    • /
    • 2002
  • Microcellular foaming Process has several merits, impact strength elevation, thermal insulation, noise insulation, and raw material saving etc. This method make the glass transition temperature of polymers low, and diminish the residual stress of polymers. This characteristics of Microcellular foaming process influences the physical properties of recycled polymers. This paper describes about the impact strength change of Microcellular foamed recycled ABS.

  • PDF

Characterization of Micro Reformer for RHFC Applications (수소개질형 연료전지용 마이크로 개질기의 제작 및 성능분석)

  • Lee H.R.;Gil J.H.;Kim S.H.;Ha J.W.;Jang J.H.;Kundu Arunabha
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.545-546
    • /
    • 2006
  • Abstract should be written in English using Times New Roman 9pt. Write English abstract here. Write English abstract here. Write English abstract here. Write English abstract here. Write English abstract here. Write English abstract here. Write English abstract here. Write English abstract here. Write English abstract here. Write English abstract here. Write English abstract here. Write English abstract here. Write English abstract here. Write English abstract here. Write English abstract here. Write English abstract here. Write English abstract here. Write English abstract here.

  • PDF

A study on crash energy absorption design of passenger-car extreme structure of tilting train prototype (한국형 고속틸팅열차의 중간부 충돌에너지 흡수구조에 대한 연구)

  • Kwon T.S.;Jung H.S.;Koo J.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.326-330
    • /
    • 2005
  • Crahworthy design of trains is now indispensable procedure in modern railway vehicle design for ensuring the safety of passengers and crew. It is now widely recognized that a more strategic approach is needed in order to absorb higher level energy in a controlled manner and minimize passenger injuries effectively. The first design step in this strategic approach is the design of the front end structure(so called HE extremities) to absorb a large part of total impact energy and then the structure of passengers non-accommodation zones(so called HE extremities) is designed to absorb the rest of impact energy. In this paper, the passengers entrance door area is selected as the LE(low energy) extremities and the design of the LEE was carried out. The main part of LEE design procedures is the design of energy absorbing tubes. For this purpose, the several tube candidates are introduced and compared to each others with numerical crash simulation.

  • PDF

Prediction of Microstructural Changes during Cryogenic Rolling of Al alloys using an Eulerian Analysis (알루미늄 합금 극저온 압연의 오일러리안 해석에서 미세조직 변화 예측)

  • Yoon S. H.;Nam W. J.;Park K. T.;Lee Y. S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.381-383
    • /
    • 2005
  • This paper is concerned with the prediction of micro structural changes of Al alloys during cryogenic rolling using an Eulerian finite element analysis. The main objective of cryogenic rolling is to obtain ultra-fine grains by severe plastic deformation at the extremely low temperature. Thereby, this simulation focuses on micro structural developments - the texture development and the changes in the size and shape of grains. The former one may be modeled using a crystal plasticity theory while the other can be predicted by a streamline technique. Applications to three pass rolling are given.

  • PDF

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.