• Title/Summary/Keyword: 바륨

Search Result 218, Processing Time 0.039 seconds

EMI (Electromagnetic Interference) Shielding Properties of Barium-Based Ferrite Thin Films Prepared by Spin Spray Method (스핀 스프레이 방식으로 제조된 바륨계 페라이트 박막의 EMI (Electromagnetic Interference) 차폐 특성)

  • Hye Ryeong Oh;Yeon-Ju Park;Woo-Sung Lee;Chan-Sei Yoo;Myong-Jae Yoo;Intae Seo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.2
    • /
    • pp.195-201
    • /
    • 2024
  • The low-temperature deposition of BaNi(2-x)CoxFe16O27 thin films with a Ba hexaferrite structure for electromagnetic shielding was studied. The BaNi(2-x)CoxFe16O27 thin films produced through the spin spray process were suitable for thin film deposition on a flexible substrate because it crystallized well at low temperature below 90℃. The change in shielding characteristics depending on the Co content of the BaNi(2-x)CoxFe16O27 thin film was investigated, and excellent shielding characteristics with S21 of -1 dB were obtained in a wide frequency range of 26~40 GHz when the Co content was 0.4 or more. The purpose of this study is to analyze changes in shielding properties caused by change in Co content in relation to phase changes in BaNi(2-x)CoxFe16O27 and obtain basic data for developing excellent flexible electromagnetic wave shielding materials.

Evaluation of the X-ray Shielding Ability of Lead Free Board Shielding in the CT Room (CT실에서 무연보드 차폐체의 X선 차폐능력 평가)

  • Sung-Joon Kim;Tae-Ho Han;Hyo-Won Lee;Yu-Whan Oh;Seung-Chul Kim;Jung-Min Kim
    • Journal of radiological science and technology
    • /
    • v.47 no.4
    • /
    • pp.249-254
    • /
    • 2024
  • This study compared the X-ray shielding abilities of the shields using Computed Radiography(CR) System after manufacturing a lead-free boards using gypsum and BaSO4, an eco-friendly X-ray shielding material. Total six lead-free boards were manufactured with BaSO4 concentrations of 25 %, 50 % and thickness of 10 mm, 15 mm, 20 mm respectively, and additional thickness of 1.0 mm, 1.5 mm, 2.0 mm leads were prepared. In the experiment, Nine shields were placed on the Image Plate and placed in a Computed Tomography(CT) Room where CT scans were performed for 2 weeks. After that, the X-ray image of the shields were obtained through CR Reader, and Pixel Value(PV) were measured to evaluated the X-ray shielding abilities of the lead-free shields. The criterion for evaluating the shields was determined by comparing PV of lead-free board to that of the 1.5 mm thickness lead used in the CT rooms. As a result of the experiment, the PV of the lead-free boards within 25 % of the BaSO4 concentration and within 10 mm of the thickness were not enough to be used as X-ray shields in the CT Room because they did not reach the PV of the 1.5 mm thickness lead. BaSO4 concentration of 50 % at 20 mm thickness showed PV of 1.5 mm lead thickness or more indicating that it has an X-ray shielding ability to replace lead in the CT room

Investigation of the Earth Science Teacher Education Programs in the College of Education and their Improvement Plans (사범대학 지구과학 교사 양성 교육 과정 현황 분석 및 개선 방안 탐색)

  • Kim, Jong-Hee;Lee, Ki-Young
    • Journal of the Korean earth science society
    • /
    • v.27 no.4
    • /
    • pp.390-400
    • /
    • 2006
  • The purpose of this study is to propose an improvement plan based on an analysis of the current earth science teacher education curriculum in the department of education in the four fields of teaching profession theory: student-teacher practice, subject lesson education, and subject content education. The following are the conclusions and suggestions of this study. In case of teaching profession theory, too much emphasis is put on pedagogical theory over practical issues, and a problem arises upon completion. Therefore, it is sugguest that teaching profession theory might be completed before subject lesson education to ensure more authentic subjects performing teaching profession. The current term for student-teacher training is too short to understand the whole school system. Current school system does not have any off-job training course or internship system. Therefore, student-teacher training term should be increased by at least $3{\sim}6$ months to play a vital role in the current system. The credit number of subject lesson education is too small compared with subject content education. Consequently, the credit number of subject lesson education should be increased, and more professor majored in subject lesson education should be recruited. Significant deviation between the content of subject content education and that of middle school grade exists, and there is also much difference in the ratio of subject according to university. To get rid of these problems, subject content education should be connected with subject lesson education and appropriate number of credit needs to be assigned to each subject domain.

Clinical Analysis of Recurrent Intussusception and the Pathologic Lead Point in a Single Center (단일 병원에서의 재발성 장중첩증과 병적 선두에 대한 임상적 고찰)

  • Lee, Kun-Song;Park, Yun-Joon
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.12 no.2
    • /
    • pp.163-170
    • /
    • 2009
  • Purpose: Intussusception is the most common cause of intestinal obstruction in young children. Although intussusceptions are easily treated, some intussusceptions with or without a pathologic lead point (PLP) often recur. In this study, we analyzed the clinical characteristics and prognosis of recurrent intussusceptions (RI), the frequency of the PLP, and correlation between RI with PLP. Methods: The medical records of 144 patients, among 590 patients with intussusceptions who had been admitted to the Department of Pediatrics and Pediatric Surgery of Dankook University Hospital between May 1994 and June 2009 were reviewed retrospectively. Results: The overall recurrence rate of intussusceptions in this study was 9.2%. The mean interval between the initial occurrence and the first recurrent attack was 130${\pm}$175 days (range, 12 hours to 3 years). There was no statistically significant difference in the recurrence rate among patients who underwent air, barium, and manual reduction (p=0.131). Eighty-seven cases (92.6%) of RI had a successful reduction by the use of non-operative techniques. A PLP was present in 18 patients (3.0%). The most common PLP was intestinal lymphoid hyperplasia, followed by Meckel's diverticulum, duplication cyst, intestinal polyp, and adenomyoma. The mean number of intussusceptions was 4.7${\pm}$1.9 in 7 patients with PLP, which was significantly higher than (2.4${\pm}$0.9) patients without a PLP (p=0.023). The mean duration of recurrences was 17.4${\pm}$19.8 months (range, 2 days to 72 months). Conclusion: A careful search for a PLP should be performed to prevent recurrence of intussusception, especially when intussusception has recurred more than three times.

  • PDF

Recent updated diagnostic methods for esophageal motility disorders (식도의 운동장애에 관한 최신지견)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.11-16
    • /
    • 2004
  • Classification of esophageal motility disorders not yet finalized and is still ongoing as the new disorders are reported, and the existing classification is changed or removed. In terms of radiology, the primary peristalsis does not exist, and the lower end of the esophagus show the smooth, tapered, beak-like appearance. The esophageal motility disorder, which mostly occurs in the smooth muscle area, show the symptoms of reduction or loss (hypomotility) or abnormal increase (hypermotility) of peristalsis of the esophagus. It is important to understand the anatomy and physiology of the esophagus for the appropriate radiological method and diagnosis. Furthermore, the symptom of the patient and the manometry finding must be closely referred for the radiological diagnosis. The lower esophageal sphincter can be normally functioning and open completely as the food moves lower. Sperandio M et al. argues that the name diffuse esophageal spasm must be changed to distal esophageal spasm (DES) as most of the spasm occurs in the distal esophagus, composed of the smooth muscle. According to Ott et al., usefulness of barium method for diagnosing the esophageal motility disorder is Achalasia 95%, DES 71% and NEMD 46%, with the overall sensitivity of 56%. However, excluding the nutcracker esophagus or nonspecific disorder which cannot be diagnosed with the radiological methods, the sensitivity increases to 89%. Using videofluoroscopy and 5 time swallows, the average sensitivity was over 90%. In conclusion, the barium method is a simple primary testing method for esophageal motility test. Using not only the image but also the videofluoroscopy with good knowledge of the anatomy and physiology, it is believed that the method will yield the accurate diagnosis.

  • PDF

Causes of Under-staging in Patients with Gastric Cancer That was Proven to be Unresectable after a Laparotomy - Correlation with CT Findings (비절제 위암의 원인분석-전산화단층촬영(CT) 소견을 중심으로)

  • Yoon, Hyuk-Jin;Shin, Jung-Hye;Kim, Gab-Chul;Yu, Wan-Sik;Chung, Ho-Young
    • Journal of Gastric Cancer
    • /
    • v.6 no.4
    • /
    • pp.263-269
    • /
    • 2006
  • Purpose: The aim of this study was to investigate the causes of under-staging in patients with advanced gastric cancer that was proven to be unresectable after a laparotomy. Materials and Methods: We retrospectively analyzed 25 gastric cancer patients who had undergone a diagnostic laparotomy between 2001 and 2005. For the preoperative evaluation, spiral CT and multidetector-row CT were performed. We analyzed the clinicopathologic features of patients and compared the image findings and the results of surgery. The causes of under-staging were divided into 3 groups; patient factor, CT factor, and interpretation factor. Results: Grossly, there were 12 cases of Borrmann type-III tumors and 13 cases of Borrmann type-IV tumors. The most frequent histologic type was poorly differentiated adenocarcinomas (8 cases) and signet ring cell carcinomas (7 cases). There were 13 cases of adjacent organ invasion, and the pancreas was the most frequently invaded organ (9 cases). There were 17 cases of peritoneal metastasis, and 3 cases of distant lymph node metastasis. For the cause of under-staging, there were four cases of patient factor, 19 cases of interpretation factor, and 9 cases of CT factor. In three cases, the cause of under-staging could not be identified. Conclusion: CT interpretation factor was the most frequent cause of under-staging in the preoperative diagnosis with gastric cancer patients. Therefore, more cautious CT interpretation is necessary to avoid unnecessary laparotomies in gastric cancer patients.

  • PDF

Fabrication and Magnetic Properties of BaFe12-2xCoxTixO19 Powders (BaFe12-2xCoxTixO19 분말의 제조 및 자기특성 연구)

  • An, Sung-Yong;Shim, In-Bo;Kim, Chul-Sung;Lee, Seung-Wha
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.1
    • /
    • pp.21-28
    • /
    • 2003
  • M-type hexagonal BaF $e_{12-2x}$ $Co_{x}$ $Ti_{x}$ $O_{19}$ (0$\leq$x$\leq$1.0) ferrite powders prepared by a sol-gel method. The crystallographic and magnetic properties were characterized with a x-ray diffraction (XRD), thermogravimetry (TG), differential thermal analysis (DIA), Fourier transform infrared spectroscopy (FT-IR), vibrating sample magnetometer (VSM), and Mossbauer spectroscopy. The result of XRD measurements show that the a and c lattice parameters increase with increasing x from $\alpha$=5.882 and c=23.215 $\AA$ for $\chi$=0.0, to $\alpha$=5.895 and c=23.295 $\AA$ for $\chi$=1.0. From the Mossbauer results, the $Co^{2+}$- $Ti^{4+}$ site occupancies have been affected the changes in the magnetization and in the coercivity. The Curie temperature linearly decreases with increasing $Co^{2+}$- $Ti^{4+}$ concentration x.

Quality Improvement on Upper Gastrointestinal Series (위장조영검사에서 화질 개선 방법)

  • Lim, Byung-Hak;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.395-401
    • /
    • 2016
  • Upper gastrointestinal series is a diagnostic test that X-ray passes through the stomach after administering contrast media such as barium or gastrografin. Upper gastrointestinal series with an advantage of no side effect except temporary constipation or abdominal pain has been widely used to diagnose diseases of the gastrointestinal system. However, image degradation and diagnostic accuracy frequently occurred when improper movement and breath control were carried out by lack of understanding the overall inspection process for the upper gastrointestinal series. The movie of the upper gastrointestinal series was made for improving inspection accuracy and image quality. The examinees encouraged to see the movie for waiting time before doing upper gastrointestinal series. In this study, image quality and diagnostic accuracy was examined for the effect of the movie about upper gastrointestinal series. 60 patients composed of each 10 people from 30s to 80s were selected randomly among both 2,940 examinees in 2014 and 3,076 examinees in 2015. Image quality was evaluated by the full width at half maximum of profile for each image using the Image J. The measurement of the full width at half maximum showed 0.208 mm and 0.133 mm for after and before seeing the movie. Thus it was verified that the movie education could improve the image quality and diagnostic accuracy for upper gastrointestinal series.

Trace element concentrations profiles in the hair of normal children living in the northern area of Seoul (서울 북부지역에 거주하는 정상 아동의 모발 미네랄 함량)

  • Kwon, Ji Won;Kim, Byung Eui;Park, Mi Jung;Kim, Sang Woo
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.1
    • /
    • pp.18-23
    • /
    • 2006
  • Purpose : The reliability of hair mineral analyses regarding nutritional status, environmental exposure or diseases is controversial. The aim of this study was to determine the normal reference range of hair mineral concentration of Korean children. Methods : We examined hair mineral concentrations of 223 children(3-12 yrs old, 110 boys, 113 girls, mean age $8.8{\pm}2.2$ yrs old) living in the northern area of Seoul. The trace elements including six toxic elements(Al, As, Cd, Ba, Hg, Pb) and 11 nutritional elements(Na, Mg, P, K, Ca, Cr, Mn, Fe, Cu, Zn, Se) were analyzed by inductive coupled plasma mass spectrometry(ICP-MS). Results : The mean concentrations of Ca and Mg were higher in girls than in boys. The mean concentrations of Cd, Pb and Cr were higher in boys than girls. The Zn, Ca, Mg, Cu and Hg levels in hair samples were positively correlated with increasing age. The Zn levels of the Korean children's hair samples appear to be lower than that of other countries' reference values. Conclusion : There are considerable differences in hair mineral concentrations by age, sex and race. Additional research is needed to establish Korean reference values, and to evaluate the usefulness of hair mineral analyses as a screening tool for nutrition- and environment-related childhood diseases.

A Study on the Damage Degree of Hair Dye Treatments and the Impact of Heavy Metals (트리트먼트(Treatment)를 이용한 모발 염색이 손상도와 중금속 함량에 미치는 영향)

  • Lee, Tae-Sook;Kim, Younghee
    • Journal of Digital Convergence
    • /
    • v.15 no.10
    • /
    • pp.551-557
    • /
    • 2017
  • Hair beauty treatments that can express individuality have increased and diversified. However, their repetitive use has also brought about hair damage. To reduce such damage, the importance of hair treatments when receiving chemotherapy has magnified greatly. In this study, the hair (normal hair, NH) of 5 people in their 20s has been collected and observed with SEM before dyeing (NH), after dyeing (DH) and after dyed and treated (DTH) to measure the hair's morphological damage and mineral content. SEM observation results revealed that, in DTH, a cuticle-like arrangement appears almost uniformly, the hair settles, the lines are smooth, and the damage degree is low. Regarding mineral content, the concentration of minerals was generally balanced. However, in the observation of toxic minerals and minerals found in large amounts, the concentration of Ba, Na, Ca, and Mg was higher than the balance range in NH, DH, and DTH.