• 제목/요약/키워드: 바닥충격진동

검색결과 255건 처리시간 0.024초

바닥충격에 의한 공동주택의 바닥, 벽, 천장의 진동 및 소음방사특성 연구 (Evaluating the Vibrational Characteristics of Floor Impact Noise in Different Structural Elements of an Apartment House)

  • 이병권;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.480-485
    • /
    • 2002
  • The overall noise reduction was compared in regard to the vibrational characteristics of floor impact noise in a multi story residential building which has several noise reduction treatments. The vibration through its structural elements such as wall, floor and ceiling and sound emitting were investigated for each insulation treatment. It was found that, in case of heavy-weight impact noise, the vibration energy is emitted mostly from ceiling, but for the light-weight impact noise, most of the energy comes through ceiling and walls. That is, the vibration of a ceiling is the main factor that determines the frequency characteristics of the transmitting noise to lower floors.

  • PDF

공동주택 경량 바닥충격음 저감성능 예측을 위한 바닥마감재 간이측정 방법 연구 (Research on simple measurement method of floor finishing materials to predict lightweight floor impact noise reduction performance in apartment houses)

  • 강민우;오양기
    • 한국음향학회지
    • /
    • 제42권6호
    • /
    • pp.594-602
    • /
    • 2023
  • 현재까지 바닥충격음은 중량 바닥충격음 연구가 주를 이루었다. 경량 바닥충격음의 경우 뜬 바닥구조만으로 충분히 차단성능을 확보할 수 있었기 때문이었다. 뜬 바닥구조에서 중량 바닥충격음의 경우 바닥완충재의 동탄성 측정을 통해 저감성능을 어느 정도 예측할 수 있다. 하지만 최근 사후 확인 제도의 도입으로 인해 다양한 바닥구조가 개발되고 있다. 특히, 완충재가 사용되지 않는 바닥구조에서는 경량 바닥충격음에 지대한 영향을 미치는 것이 바닥마감재이다. 하지만 바닥마감재에 대한 탄성이나 물성을 측정하여 경량바닥충격음을 효과적으로 저감 하기 위한 연구는 부족한 실정이다. 이 연구에서는 사후 확인 제도 도입 이후 중요해 질 수 있는 바닥마감재의 경량바닥충격음 저감성능 예측하고자 하였다. 공동주택 바닥마감재로 사용되는 다양한 재료를 선정하여 실제 실험실에서 경량바닥충격음 차음성능을 측정하고 간이 실험으로 진동 전달특성 파악을 통해 경량바닥충격음 예측 가능성을 확인하고자 하였다.

수직진동 사용성 기준을 고려한 바닥판 두께 제안 (Probability Based Determination of Slab Thickness Satisfying Floor Vibration Criteria)

  • 이민정;남상욱;한상환
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.687-694
    • /
    • 2005
  • 건설 재료와 기술의 발달로 건축물이 장스팬화 ·경량화 되어 가고 있다. 이로 인해 건축물 바닥의 고유진동수(Frequency)와 감쇠비(damping ratio)가 감소함에 따라 거주자들의 바닥판의 수직진동에 대한 문제가 발생하고 있다 그러나 현행 사용성 기준은 바닥판의 최대 정적 처짐에 의해 결정하고 있다. 하지만 선행연구(Han et al., 2003)에서 현행 기준을 만족하는 바닥이 수직진동에 대한 사용성 기준을 만족하지 못하는 것을 볼 수 있다. 따라서 본 연구에서는 거주자들의 뒤꿈치 충격하중에 대한 수직진동 사용성 기준을 만족하는 바닥 두께를 제안하고자 하였다. 슬래브 재료의 특성과 뒤꿈치 충격하중 및 마감 고정하중의 불확실성을 고려하기 위해 Monte Carlo Simulation을 사용하여 확률적으로 접근하였다. 그 결과 4변 단순지지의 경우 두께가 스팬 길이의 $1/14\~1/17$에서, 4변 고정지지의 경우 스팬 길이의 $1/18\~1/25$인 경우에 초과 확률이$0\%$에 도달하였다.

공동주택의 바닥 충격 진동 해석을 위한 유한요소법 응용 (Application of Finite Element Method to Floor Impact Vibration Analysis in the Apartment Buildings)

  • 서상호;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.387-390
    • /
    • 2005
  • Finite element method was applied to the vibration analysis of concrete slab system in apartment building. To save the time and cost the 2 dimensional finite element model was proposed. At first, experimental results show that sound peak components to influence the overall level and the rating of floor impact sound insulation were coincident with natural frequencies of the reinforced concrete slab. Second, there is linear relationship between the impact sound pressure level and vibration acceleration level. Third, 2 dimensional finite element model was enough to analyze the vibration analysis of floor structure system.

  • PDF

수음실 내 구조체의 진동량 계측을 통한 바닥충격음레벨 예측 (Prediction of Floor Impact Sound by Measuring the Vibration Acceleration Level on the Interior Structures of Receiving Room in Apartment Buildings)

  • 김명준;김흥식;김하근
    • 한국소음진동공학회논문집
    • /
    • 제13권1호
    • /
    • pp.3-9
    • /
    • 2003
  • In an apartment building, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. To set the optimum design for sound insulation. it is nesessary to suggest the useful tools or technique that predict the floor impact sound. The purpose of this study is to investigate the applicability of the theory of sound radiation. We measured the vibration acceleration levels on the interior structures and predicted the sound pressure level of the room by using them. The result show that the predicted value, in general, were in good agreement with the measured values within 5∼10% in error rate.

주택성능등급제도내 바닥충격음 개선방안 연구 (A Study on Improvement of Floor Impact Noise Section in the Housing Performance Grading Indication System)

  • 고종철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.593-594
    • /
    • 2008
  • The purpose of this study is to review and to suggest improvement concerning floor impact noise section of the housing performance grading indication system. After a result, the main improvement is to resolve the discrepancies in the rules or regulations such as design specification(standard floor system) or design performance(accredited floor system) and as-built performance like 58 dB.

  • PDF

경량충격음 성능 평가를 위한 실험실용 시험장치 개발 (Development of a Laboratory Test Device for the Performance Evaluation of Light-weight Impact Sound)

  • 양수영;홍병국;송화영;김범수;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.505-508
    • /
    • 2004
  • 단열완충재 제품간의 경량충원 저감성능 평가를 객관적이고 신속하게 판별하기 위하여 실험실용 시험장치를 개발하였다. EVA계열 및 EPPㆍEPS계열의 단열완충재들에 대한 경량충격원 시험에서 제품간의 성능비교가 가능하였으며, 동탄성계수 및 손실계수 측정과 병행함으로써 제품들간의 우열성을 보다 정밀하게 평가할 수 있었다.

  • PDF

바닥충격음 측정용 표준충격원과 실충격원의 특성 비교 (Comparison of Standard Floor Impact Sources with a Human Impact Source)

  • 이평직;정정호;박준홍;전진용
    • 한국소음진동공학회논문집
    • /
    • 제16권8호
    • /
    • pp.789-796
    • /
    • 2006
  • The characteristics of the four standard floor impact sources (impact ball, bang machine, tapping machine, modified tapping machine) and a human impact source (jumping children) were investigated. First, the mechanical impedance of each source were evaluated. Then, the impact force exposure level of each source were measured. The results showed that fundamental frequency and impedance produced by the impact ball are the most similar to those of the human impact source. The frequency characteristics of the impact ball were most similar to those of jumping children. Consequently, the impact ball more accurately reproduces human impact compared to the other standard impact sources. Therefore, the impact ball should be considered as the reliable impactor in evaluating floor impact noise.

콘크리트 슬래브와 바닥 상부구조가 일체된 바닥구조의 바닥충격음 (Floor Impact Noise Level for Concrete Slab Integrated with Floor Finishing Layers)

  • 문대호;오양기;정갑철;박홍근
    • 한국소음진동공학회논문집
    • /
    • 제26권2호
    • /
    • pp.130-140
    • /
    • 2016
  • Floating floor is most commonly used at apartment houses in Korea for thermal insulation and reducing impact noise. But it in proven that the floating floor is not effective for reducing the floor impact noise in low frequency range. In most cases, impact sound pressure level under 63 Hz frequency band were actually increased by the resonance of resilient material, lightweight concrete and the finishing mortar installed on it. In this paper, an integrated floor system consist of 70 mm light weight concrete and 40 mm finishing mortar successively installed on the concrete slab was suggested to avoid the resonance. Integrated floor system increases total flexural stiffness and mass per unit area. The natural frequencies of first and second vibration mode were increased and acceleration response and floor impact sound level was decreased in all measurement range.