A Research on the Indoor Thermal Environment in Livingroom with Radiant Floor Heating System - Casestudy in Korea and Japan - (바닥 난방을 사용하는 주택내 거실 온열 환경의 실태조사 -서울과 동경의 사례조사 -)

  • Chun Chung-Yoon;Mitamura Teruaki;Fukai Kazoo
    • Journal of the Korean housing association
    • /
    • v.16 no.1
    • /
    • pp.11-16
    • /
    • 2005
  • The purpose of this study is to find out the present thermal environment of the Korean livingroom in comparison with the Japan's. Thermal environment of the livingroom with radiant floor heating system in Korea and Japan is analysed. The surveys and measurements are took place in two detached houses and two apartments in Seoul, Korea and two apartments in Tokyo, Japan for a 48-hour period at the beginning of March, 2003. The result of this study shows that the thermal environment of the livingroom in Korean houses, especially in the apartments is warmer and stabler than the Japan's. However, despite of its high temperature, Koreans have a tendency to rise their room temperature creating excess.

A Study on Thermal Heating Control Performance of Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방 시스템의 열환경 개선을 위한 제어방안 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon;Kim, Kyung-Chul;Jang, Sa-Yun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.973-978
    • /
    • 2009
  • In this study, the thermal environment characteristics of On-Off control and thermal difference proportional control method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on two control methods, conventional on-off control and temperature error based time control(T.E.B.T.C.) method, are performed to compare thermal heating control performances, respectively.

  • PDF

Comparison of Thermal Environment in Livingroom between Korea and Japan (바닥 난방을 사용하는 주택내 거실 온열 환경의 한일비교)

  • Lee, Min-Jung;Chun, Chung-Yoon
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.47-51
    • /
    • 2003
  • In this paper, we compared the thermal environment in the livingroom with panel heating system of Korea and Japan. The houses are two apartments and two single houses in Korea, and two apartments in Japan. The outdoor temperatures, indoor air temperatures, surface temperatures on floor and humidities were measured. The survey to the residents and recording of operation were also collected. The results were as follows.1. The Korean houses are warmer and drier(approximately 23$^{\circ}$C, 38%) than those of Japan.(approximately 20$^{\circ}$C, 57%). And indoor temperaures of Korean apartment are stabie. 2.The residents in Japan put on and off the switches of the heating system frequently.

  • PDF

Application Study of the Predictive Pulse Control for Floor Heating System (바닥난방을 위한 부하 예측식 펄스제어 방식의 적용성 연구)

  • Cho, Sung-Hwan;Kim, Seong-Su;Kim, Yong-Bong;Na, Hee-Hyeong
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.167-175
    • /
    • 2007
  • A predictive pulse control strategy as a means of improving the energy efficiency of radiant floor heating systems is explored. Experiments at the apartment with floor heating system are conducted to assess and compare the energy performance of the predictive pulse control strategy with an existing conventional control strategy. The Results showed that new suggested PPCM( Predictive Pulse Control Method) was available to decrease the gap of $1{\sim}1.5^{\circ}C$ between maximum and minimum indoor temperature of each rooms. Therefore PPCM method was favor to radiant floor heating system which have a delay time of 10-20 minutes for heat transfer by floor layers.

  • PDF

A Study on the Performance Analysis of Proportional Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방 시스템용 비례식 자동온도조절밸브의 성능해석에 관한 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon;Kim, Yong-Ki;Lee, Tae-Won
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.52-57
    • /
    • 2007
  • The control characteristics for radiant panel heating system with automatic thermostatic valves were researched by computer simulation and experiment. The unsteady energy analysis using equivalent R-C circuit method and radiation heat transfer analysis of enclosure analysis method with simple structured rooms was performed. The results of flow rate changes of the simulation study are good fit with the ones of experimental one.

  • PDF

Performance Evaluation of Air Source Multi Heat Pump Floor Heating System in Apartment (공동주택 공기열 멀티 히트펌프의 바닥난방 성능 평가)

  • LEE, C.H.;Nah, H.S.;JUNG, H.;Kim, K.S.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.93-98
    • /
    • 2011
  • To analyze and evaluate the performance of developing air to water multi heat pump, the heat pump was installed and tested at low energy house in Daejeon, korea. Heating capacity of heat pump is 16.5KW and cooling capacity is 14.0KW. Space heating/cooling, floor heating and hot water is available. The results performance evaluation of heat pump in lab test showed that the coefficient of performance (cop) was 3.75, and heating capacity was 16.0KW in ambient temperature $7^{\circ}C$. Also at ambient temperature $-15^{\circ}C$, the COP was 1.69. At a low energy house, floor heating is controled by a floor heating water temperature and a room temperature. The COP of heat pump is decreased with frequent on/off operation for controlling of floor heating water temperature.

Effects of Phase Change Material Floor Heating Systems using Direct Solar Gain on Cooling Load (직달일사를 이용한 잠열축열식 바닥난방 시스템이 냉방부하에 미치는 영향에 대한 검토)

  • Kim, Soo-Kyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.3
    • /
    • pp.9-16
    • /
    • 2013
  • In this research, the effect of a heating system, which is powered by direct solar energy accumulated in phase change material (PCM) as heat storage material installed on the floor surface, on the cooling load was studied. Cooling load of a test building designed for this research was measured with fan coil unit and factors affecting it were also estimated. Experiments were performed with and without PCM installed on the building floor to understand the effect of the PCM on the cooling load. Additionally, to confirm the experiments results, the prediction calculation formula by average outside temperature and integrated solar radiation was composed using multivariate regression model. The results suggested that the heating system with PCM on the floor surface has the potential to shift electric power peak by radiating heat, stored during the daytime in it, at night, not increasing the total cooling load much.

Research on the actual condition of 'Under Floor Radiant Heating for Apartment Housing' (주거용건물의 바닥복사 난방방식에 대한 실태조사 연구)

  • Woo, Byung-Kwan;Lee, Sung;Kim, Sam-uel
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.81-86
    • /
    • 2007
  • The research analyzes the arrangement of boiler and hot water header, the method of radiator pipe setting, hot water supply control, hourly heating situation of each room for underfloor radiant heating systems in Korea and suggests an alternative to improve to efficient heating method. One of the best options for install position of hot water distributor is under kitchen sink which is center point of all rooms, according to previous research of the energy saving strategies. When the radiator pipes are arranged to each individual room instead of bedrooms through livingroom and kitchen, it has energy saving effects. For rooms without occupancy according to a time period, hot water supply method should be intermittent heating rather than continuous heating. For this intermittent heating method, individual control of hot water supply is more practical, and it can lead to massive energy savings. The intermittent heating system has time-lag, so it is more effective in energy saving with mild and comfort condition if the spaces are preheated by automatic control equipment prior to required time.

Floor Heating Characteristics of Latent Heat Storage-Bioceramic Ondal - Focused on Historical research and Expermental Analysis - (잠열 축열-바이오 세라믹 온돌의 난방 특성 - 온돌의 역사적 고찰 및 실험적 분석을 중심으로 -)

  • Sone, Hyun-Kap;Ryon, Young-Sun
    • Solar Energy
    • /
    • v.15 no.1
    • /
    • pp.13-28
    • /
    • 1995
  • In this study, the history of Korean traditional Ondol was investigated and the latent heat materials and bioceramics were selected to develop the latent heat storage-bioceramics Ondol system based on the Korean traditional Ondol(sensible heat storage type), and the thermal characteristics of Ondol were analyzed experimentally The results could be summarized as follows; 1. Korean traditional Ondol has been originated in "Whaduk" which had been utilized continuously for about $2{\times}10^6$ years from the Old Stone Age to the Bronze Age, and Korean traditional Ondol using in these days has been utilized for about 976 years from the Koryu Dynasty to the Modern Ages. 2. $Na_2SO_4{\cdot}10H_2O(SSD)$ was selected as latent heat material for the latent heat storage Ondol. 3. Ondol unit was filled with the latent heat material of 0.63 kg and the dimension of Ondol unit was $400mm{\times}400mm{\times}27mm(width{\t\imes}depth{\times}height)$. 4. The comfortable surface temperature($23{\sim}29^{\circ}C$) of the latent heat storage Ondol was lasted 5 hours at the room temperature of $16{\sim}18^{\circ}C$, whereas that of sensible heat storage Ondol was lasted only 1.0 hours in the same conditions. 5. For the thermal effect of bioceramics, the Ondol air temperature i.n case of bioceramics treatment on the pannel was higher than that of without bioceramics treatment.

  • PDF