• Title/Summary/Keyword: 바닥구조

Search Result 948, Processing Time 0.032 seconds

A Study of Dynamic Behavior of Segmental U-shaped Prestressed Concrete Girder Applied with Integrated Tensioning Systems (복합긴장방식이 적용된 세그멘탈 U형 거더 동적 거동 특성 연구)

  • Hyunock Jang;Ilyoung Jang
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.369-378
    • /
    • 2024
  • Purpose: This study aims to verify structural stability by manufacturing a 40m full-scale specimen composed of a segmental U-shaped PSC girder with integrated tensioning systems and a concrete slab, proceeding dynamic behavior tests, and compare the results of the tests with the results of numerical analysis. Method: Dynamic behavior tests were conducted on a full-scale, undamaged specimen using an impact hammer, and the natural frequency and damping ratio were measured and compared with numerical analysis techniques and the general damping ratio of the facilities. Result: The natural frequency of the numerical analysis model consisting of a girder and slab composite section was calculated to be 2.561Hz, the natural frequency of the full-scale specimen was measured to be 2.670Hz, and the damping ratio was calculated to be 0.42~0.68%. Conclusion: The natural frequency of the full-scale specimen was found to be 4.3% larger than that of the numerical analysis model. Since the masses of the full-scale specimen and the numerical analysis model are the same as 99.97%, it can be derived that the stiffness of the full-scale specimen has secured structural safety and stability. As a result, the dynamic behavior stability of the specimen was verified. The measured damping ratio of 0.42~0.68% was found to be a stable dynamic behavior compared to the PSC structures damping ratio of 0.5~1.0% in the elastic region.

Site Characteristics Around the Gongsansung Circular Pond in Gongju Based on the Seismic Methods (탄성파탐사를 이용한 공주 공산성 원형연못의 지반조사)

  • Oh, Jin-Yong;Suh, Man-Cheol
    • Economic and Environmental Geology
    • /
    • v.38 no.6 s.175
    • /
    • pp.623-631
    • /
    • 2005
  • We applied the seismic method to investigate the site characteristics around the Circular Pond (top diameter 7.3 m, bottom diameter 3 m, and depth 4.78 m) at the Ssangsujung Park within the Gongsansung in Gongju. Previous excavations for the cultural assets beneath the Ssangsujung Park disclosed the assumed site of the Palace of the Beakje Dynasty and the Circular Pond containing the Bakje relics. We demonstrated that the seismic prospecting can be applicable to delineate the underground structure around the cultural properties by the three kinds of seismic approaches: walk-away test, conventional refraction method, and equal-distance refraction survey. The last method which is designed by this work ran detect the I-W variations of seismic velocity in the subsurface medium across the Circular Pond on the basis of the difference of the P-wave arrival times between the 1-m-spacing 24 geophones and the corresponding 24 shots parallel with the geophone profile. From the combined results, prominent three-layer velocity structure is observed around the Circular Pond. The bottom layer is interpreted as the basement rock which is exposed near the Ssangsujung whereas the upper layer with relatively lower velocities is interpreted to be the artificial covering. The basement depth beneath the Circular Pond is deeper than the norhern area. The western basement of Circular Pond has the thicker weaker layer compared with the eastern part. Thus, the middle layer could be constructed as the artificial foundation during the Beakje Dynasty. Consequently, the Kong-sansung Circular Pond is possibly built upwardly rather than digging.

Structural Design And Analysis of Haeundae Doosan We've The Zenith (해운대 두산 위브 더 제니스 구조설계)

  • Park, Ki-Hong;Park, Suk-Jin
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.93-98
    • /
    • 2008
  • Haeundae Doosan We've The Zenith project is adjacent to Suyoung-bay, now it is in the process of excavation and foundation work. The main use of the tower is residence which height is 300m and 80 floor, the highest residential reinforced concrete building through the Orient. It is comprised of 3 high- rised buildings and 1 low-rised building, the basement is 230m wide and 200m length sized mass structure. The lateral resistance system is acted effectively against the lateral load and satisfactorily against the wind vibration by the 4 direction extension of the center core wall($700{\sim}800mm$ thickness) and reinforced concrete column set around the slab. Flat-plate slab system(250mm thickness) is adjusted for the slab system and it enables effective work process and shortening the working term by minimizing the ceiling height and not needing to install perimeter beam and drop panel. The strength and serviceability of the structure is able to be monitored and estimated constantly through the health monitoring system during the construction and after the construction.

  • PDF

Structural Analysis of a Suction Pad for a Removable Bike Carrier using Computational and Experimental Methods (탈착식 자전거 캐리어용 흡착 패드의 실험 및 전산적 방법을 활용한 구조해석)

  • Suh, Yeong Sung;Lim, Geun Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.622-628
    • /
    • 2016
  • As the suction pad-supporting bike carrier attached to a car may be subject to an excessive dynamic load due to random vibrations and centrifugal forces during driving, its structural safety is of great concern. To examine this, the finite-element method with a fluid-structure interaction should be used because the pressure on the pad bottom is changed in real time according to the fluctuations of the force or the moment applied on the pad. This method, however, has high computing costs in terms of modeling efforts and software expense. Moreover, the accuracy of computation is not easily guaranteed. Therefore, a new method combining the experiment and computation is proposed in this paper: the bottom pressure and contact area of the pad under varying loads was measured in real time and the acquired data are then used in the nonlinear elastic finite-element calculations. The computational and experimental results obtained with the product under development showed that the safety margin of the pad under the axial loading is relatively sufficient, whereas with an excessive rotational loading, the pad is vulnerable to separation or a local surface damage; hence, the safety margin may not be secured. The predicted contact behavior under the variation of the magnitude and type of the loading were in good agreement with the one from the experiment. The proposed analysis method in this study could be used in the design of similar vacuum pad systems.

Analysis of Characteristics for Bank Scour around Low Dam using 3D Numerical Simulation (3차원 수치모의를 이용한 보 접속부 세굴 특성 분석)

  • Jung, Suk Il;Yeo, Chang Geon;Yoon, Gwang Seok;Lee, Seung Oh
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.102-102
    • /
    • 2011
  • 보는 하천에서 취수나 하상유지를 위한 하천횡단구조물로 일반적으로 본체, 물받이, 바닥보호공 등으로 구성되며 제방 연결부 호안 및 밑다짐 등에 대한 설계기준이 하천설계기준에 제시되어 있다. 그러나 태풍 루사나 매미에 의한 피해사례를 보면 하천 횡단 구조물 본체가 파괴되는 피해 뿐만 아니라, 구조물과 제방과의 연결부가 세굴이 발생되어 붕괴되는 사례가 많이 발생하고 있다. 하천설계기준 해설(2009)에는 이러한 보와 제방의 연결부 부분을 연결호안이라하여 관련 기준을 제시하고 있으나, 설치구간의 길이를 정할 때 하천의 규모나 하도의 특성을 고려하지 못하고 일률적으로 결정하도록 하고 있다. 이에 건설기술연구원의 '보 및 낙차공 설계기술 개발 연구보고서'(윤광석 등, 2006)에서는 고정상 실험을 통해 연결호안 설치구간에 대한 실험식을 제시하였다. 본 연구에서는 3차원 수치모의를 통하여 건설기술연구원에서 수행하였던 실험을 재현하고, 제방을 이동상으로 하여 인자들 간의 상호 관계를 밝히며, 그 특성을 분석하고자 한다. 그리고 윤광석 등(2006)에 의해 제시된 실험식에 적용하여 검증하였다. 수치모의는 유량을 $0.7{\sim}2.8m^3/sec$까지 변화하며 수행하였으며, 유사의 대표입경은 0.63mm로, 상류수심은 1.0m로 일정하게 유지하였다. 수치모의는 평형세굴 발생 후, 최소 모의시간의 10%정도 지난 시간까지 하였다. 수치모의 결과는 다음과 같다. (1) 유량이 증가함에 따라 유속 및 Froude 수가 증가하여 상 하류부 세굴 발생 범위와 폭은 증가하였다. (2) 상류는 하류에 비해 유량에 따른 세굴발생 범위가 상대적으로 작게 나타났으며, 이는 하류단에 비해 상류단의 유속 및 Froude 수의 차이가 작았기 때문인 것으로 판단된다. (3) 세굴의 폭을 측정함으로써 세굴에 가장 취약한 부분을 짐작할 수 있으며, 설계에 반영되어 호안이나 옹벽의 두께결정에 적용한다면 세굴에 대해 좀 더 안전한 설계가 될 수 있을 것이다. (4) 건설기술연구원(2006)에서 제시한 식(1)과의 비교를 통해 수치모의 결과가 식(1)로부터 계산된 값보다 작음을 알 수 있으며, 그 이유는 식(1)의 범위는 와류영역구간을 나타내서 연결호안 설치구간 길이를 제시하고 있는 반면, 본 연구의 수치모의 결과는 세굴이 발생한 범위를 제시하였기 때문이다. 향후 보 높이와 좀 더 다양한 유량에 대한 경우를 수치모의하고, 이동상 제방에 대한 실험을 통해 명확한 식을 제안 할 것이다.

  • PDF

Mucous Cells and Their Structure on the Epidermis of Five Appendages in the Korean Flat- headed Goby, Luciogobius guttatus (Pisces; Perciformes) (한국산 미끈망둑 Luciogobius guffafus(농어목) 5개 부속지의 표피구조 및 점액세포)

  • Park, Jong-Young;Kim, Ik-Soo;Lee, Yong-Joo;Baek, Hyun-A
    • Korean Journal of Ichthyology
    • /
    • v.17 no.3
    • /
    • pp.167-172
    • /
    • 2005
  • The flat-headed goby, Luciogobius guttatus, inhabits tidepools and river mouths, and stays under stones on the dried bottom for the duration of the low tide. To know the relationship of its respiration and habit in this fish, the epidermis of five appendages was observed. The epidermis has three layers: the outermost layer, middle layer and stratum germinativum. The outermost layer is composed of polygonal cells or rather flattened cells, and mucous cells. The unicellular mucous cells showing acid mucopolysaccharides are 11.1 to $16.1{\mu}m$ in mean height and in one or two rows. The middle layer consists mainly of large epidermal cells that are swollen by adjacent epidermal cells and arranged in a web-shaped structure. The swollen cells are 12.3 to $15.2{\mu}m$ in mean height and arranged in one to 11 layers. Since the swollen cells occupy the entire height of the epidermis, the epidermis is thick. A large number of blood capillaries are present just below the stratum germinativum. Taste buds are distributed at intervals on the surface of the epidermis. Based on these epidermal strucures, it is likely that L. guttatus utilizes cutaneous respiration in a dual respiratory systems.

Confinement Range of Transverse Reinforcements for T-shaped Reinforced Concrete Walls (철근콘크리트 T형 벽체의 콘크리트 구속을 위한 횡철근의 배근범위)

  • 하상수;오영훈;최창식;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.1001-1009
    • /
    • 2002
  • The objective of this study is to determine the range of confinement (or the transverse reinforcement of the reinforced concrete structural walls with the T-shaped cross section subjected to cyclic lateral loads. The range of confinement for transverse reinforcement is related to the location of neutral axis and determined by the magnitude and distribution of compressive strain. The compressive strain depends on the ratio of wall cross sectional area to the floor-plan area, the aspect ratio, configuration, the axial load, and the reinforcement ratios. By affection of flange, the neutral axis appears different depending on positive and negative forces and because of this reason, when web and flange are subjected to compressive stress, the range of confinement for the transverse reinforcement of T-shaped walls would shows different result. Therefore this experimental research focused on the structural characteristics of T-shaped walls and suggested the neutral axis depth through comparing the results of this study with sectional analysis.

The Study on the Countermeasure Plans about Leakage, Explosion and Fire Accidents of Atmospheric Storage Tank (옥외저장탱크 누출, 폭발 및 화재사고 대응방안에 관한 고찰)

  • Lee, Gab-Kyoo
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.48-56
    • /
    • 2016
  • A crude oil leakage from a large atmospheric storage tank occurred on 4 April 2014 at 14:50 in Ulsan City, while storing the crude oil in the tank. Emergency Rescue Control Group was deployed in the scene. The company, Fire Service Headquarters and associated agencies got together in Command Post (CP) for discussing an effective corresponding strategy. Many solution plans were drafted in the debate such as power down, stopping the facilities, checking the density of inflammable gas, suppressing oil evaporation, moving the leaked crude oil to a nearby tank and a processing plant and avoiding marine pollution. All the solutions were carried out in cooperation with several agencies and partners. The oil leakage accident was successfully settled up within the process of responding, The Fire Service Headquarters and the company thought that the most important thing was the suppression of oil evaporation and the elimination of ignition source. With Fire Service Headquarters and several agencies' every effort, an explosion and a fire didn't occurred in the scene. This study suggest the improvement of the operating system in Emergency Rescue Control Group in case of petroleum leakage, explosion and fire accidents of atmospheric storage tank, different from a ordinary disaster. Assuming that petroleum leakage in atmospheric storage tank develop the explosion and fire accidents, the spreading speed of the flame and the burning time was experimented and compared with each other. Furthermore, this study concentrates on the effective field response plan prepared for the afterward explosion and fire accidents from petroleum leak in a storage tank, with the database experimented and analyzed in accordance with the angle of radiation in the foam nozzle and the pressure of pumping in a fire engine.

Lateral Load Test on the Bar-type Anti-buoyancy Anchors in the Weathered Rock (풍화암에 시공된 Bar Type 부력앵커의 수평재하시험)

  • Park, Chan-Duk;Lee, Kyu-Hwan;Ryu, Nam-Jae;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.4
    • /
    • pp.165-174
    • /
    • 2004
  • This study is about a horizontal load test of buoyance anchor installed in the section where underground water level happens in the depth of 5m under the ground when the ground is excavated, because the section as a excavation section of high speed railway ${\bigcirc}{\bigcirc}$ station is near a rivers and because the section always has a reservoir of full water level on the left. Therefore, in this study we will appraise the long-term stability of the structure permanently being taken buoyance by the underground water level, through the spot test of the buoyance anchor installed in the section where underground water level happens. For that, Bar Type anchor is used, which can get enough pulling-out force by a method to resist buoyance by using friction force against the ground by high strength steel rod or steel wire. Anti-buoyance anchor is installed on the bottom slab of underground structure being taken horizontal force by the braking and accelerating of high speed train. And, It is aimed to analyze and grasp the review result of stability for the horizontal force that happens at the parking and stopping of high speed train, by executing horizontal load test for the grasping of the movements characteristic of buoyance anchor.

Genetic Differentiation between Up- and Downstream Populations of Tribolodon hakonensis (Pieces: Cyprinidae) (삼척오십천 상.하류에 분포하는 황어, Tribolodon hakonensis (잉어과) 집단의 유전적 분화)

  • Lee, Sihn-Ae;Lee, Wan-Ok;Suk, Ho-Young
    • Korean Journal of Environment and Ecology
    • /
    • v.26 no.4
    • /
    • pp.475-483
    • /
    • 2012
  • Tribolodon hakonensis(Cypriniformes; Leuciscinae) is anadromous; they are born in freshwater, migrate back to the ocean, then return to their home stream for spawning from mid-March to early-June. Here, five microsatellites were used to assess the level of gene flow among T. hakonensis populations from the Samcheok-Oship Stream, South Korea. The frequencies of dominant alleles across several loci differed between down-and upstream populations divided by several weirs, and pairwise multilocus $F_{ST}$ estimate was significantly high(0.083). However, there were no signs of any loss of genetic variation in the upstream population. Assignment tests of individuals in admixture model(K=2) to a set of baseline samples showed fairly correct assignment to each cluster; all of upstream individuals sere included in the first cluster, while the majority of downstream individuals(65%) comprise the second cluster. These results indicate reduced gene flow between up- and downstream populations but allowing passive downstream drift. It is likely that man-made structures might at least partially be a factor for creating and consolidating the current distribution patterns of genetic variation among T. hakonensis populations in the Samcheok-Oship Stream. This information will assist governing agencies in making informed decisions regarding conservation of anadromous fishes in Korean drainage systems.