• Title/Summary/Keyword: 밀도비

Search Result 3,194, Processing Time 0.032 seconds

Effects of Several Insecticides on the Biology and Population of the Brown Planthopper, Nilaparvata lugens STAL (몇가지 수도용 살충제 처리가 벼멸구 차세대 밀도에 미치는 영향)

  • Lee Hyung-Rae
    • Korean journal of applied entomology
    • /
    • v.23 no.3 s.60
    • /
    • pp.172-176
    • /
    • 1984
  • The insecticides MIPC, BPMC, carbofuran and diazinon were treated to the brown planthopper (BPH) , Nilaparvata lugens STAL, at the dose levels of $LD_{10}\;and\;LD_{50}$(by topical application)/at the rate of 40kg/ha (product base) (by dusting or broadcasting on potted rice). The BPH population in the first generation was significantly decreased in the topical treatments compared to the untreatment. The number of BPH offsprings was relatively greater at the dose level of $LD_{10}\;than\;of\;LD_{50}$. The number of nymphs, however, were greatly varied with the insecticides. The offsprings from the BPH treated with the rate of 40kg/ha showed longer nymphal periods and higher adult emergence, but except diazinon treatment, rather less egg-numbers were observed. The BPH population density was significantly decreased in general up to 38 days after treatment(DAT) in the treated pots. Among the insecticides tested, however, only diazinon induced greater number of insects at the 54 DAT compared to the untreated pots.

  • PDF

Effect of Flow Channel Shape on Performance in Reverse Electrodialysis (유로 형상이 역전기투석 장치의 성능에 미치는 영향)

  • Kwon, Kilsung;Kim, Deok Han;Kim, Daejoong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.5
    • /
    • pp.347-352
    • /
    • 2017
  • Reverse electrodialysis (RED), which generates electrical energy from the difference in concentration of two solutions, has been actively studied owing to its high potential and the increased interest in renewable energy resulting from the Paris Agreement on climate change. For RED commercialization, its power density needs to be maximized, and therefore various methods have been discussed. In this paper, the power density was measured using various flow shapes based on the aspect ratio, opening ratio, and number of distribution channels. We found that the power density is enhanced with a decrease in the aspect ratio and an increase in the opening ratio and number of distribution channels.

Indium Pre-deposition 법으로 성장한 InAs/GaAs 양자점의 광학적 특성

  • O, Jae-Won;Gwon, Se-Ra;Ryu, Mi-Lee;Jo, Byeong-Gu;Kim, Jin-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.332-332
    • /
    • 2012
  • 분자선 에피탁시(molecular beam epitaxy)를 이용하여 GaAs 기판에 성장한 InAs 양자점(QDs: quantum dots)은 성장 온도, 압력, As/In의 공급비 등의 성장 조건에 따라 다른 변수(parameter)를 갖는다. 따라서 성장변수에 따라 양자점의 모양과 크기, 밀도가 달라져 균일한 양자점 형성에 어려움이 있어 많은 연구가 진행되고 있다. 예를 들면 In-interruption 법으로 성장한 양자점의 특성이 S-K mode (Stranski-Krastanov mode)로 성장한 양자점에 비해 광학적 특성이 향상되었다. 본 연구에서는 In pre-deposition (IPD) 법으로 성장한 InAs/GaAs 양자점의 광학적 특성을 PL(photoluminescence)와 TRPL (time-resolved PL)을 이용하여 분석하였다. InAs QDs 시료들은 In과 As 공급시간을 각각 1초와 19초 (QD1), 2초와 18초 (QD2), 3초와 17초 (QD3)로 조절하여 성장하였으며, In이 공급되는 시간 동안 As shutter를 차단하여 As 공급을 중단하였다. In과 As의 차단 없이 S-K mode로 성장한 시료를 기준시료로 사용하였다 (QD0). AFM (atomic force microscope) 측정결과, In 공급시간이 1초에서 2초로 증가할 때, 양자점의 밀도와 종횡비(aspect ratio)가 증가하였고, 양자점의 균일도가 증가하였다. 그러나 QD3 시료는 QD1 시료에 비해 밀도와 종횡비, 균일도가 감소하였다. 10 K에서 PL 피크는 In 공급 시간이 증가할 때, 970 nm에서 1020 nm로 적색편이 하였고 반치폭 (FWHM: full width at half maximum)은 75 meV에서 85 meV로 증가하였다. QD2 시료의 PL 피크 에너지가 가장 낮았고, 가장 강한 PL 세기를 보였다. IPD 시간이 증가함에 따라 PL 피크에서 측정한 PL 소멸은 점차 빨라졌다. IPD 기법으로 성장한 양자점의 빠른 PL 소멸은 양자점 밀도와 종횡비 향상에 의한 파동함수 중첩의 증가와 구속 에너지 증가에 의한 것으로 설명된다.

  • PDF

Spatial Measurement of Plasma Temperature & Density in a microdischarge AC-PDP cell

  • 김진구
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.231-231
    • /
    • 1999
  • PDP(Plasma Display Panel)는 21세기 디스플레이 시장을 대체할 차세대 디스플레이 장치로서 넓은 시야각, 얇고, 가볍고, 메모리기능이 있다는 여러 가지 장점들을 가지고 있지만 현재 고휘도, 고효율, 저소비전력 등의 문제점들을 해결하여야 한다. 이러한 문제점들의 해결을 위해서는 명확한 미세방전 PDP 플라즈마에 대한 정확한 진단 및 해석이 필요하다. 따라서 본 연구에서는 미세 면방전 AC-PDP 플라즈마의 기초 변수들 (플라즈마 밀도 & 온도, 플라즈마 뜬 전위, 플라즈마 전위 등의 측정을 통해 고휘도, 고효율 PDP를 위한 최적의 방전환경을 알아내는 데 있다. 일반적으로 전자의 밀도는 방전전류에 비례하는 관계를 보인다. 전류에 대해 방전전압이 일정하다면 전자밀도가 커짐에 따라서 휘도는 포화되며 상대적으로 휘도와 전류의 비로 표시되는 발광효율은 감소하게 된다. 반면 전자밀도가 상당히 작다면 휘도는 전자밀도에 비례하고 효율은 최대값을 보인다. 따라서 미세구조 PDP에서 휘도와 발광효율, 양쪽에 부합하는 최적의 방전환경을 플라즈마 전자밀도와 온도의 측정을 통해서 해석하는 것이 필요하다. 본 실험에서는 방전기체의 종류와 Ne+Xe 방전기체의 조성비에 따른 플라즈마 밀도, 온도의 공간적인 분포특성을 진단하기 위해서 초미세 랑뮈에 탐침(지름: 수 $mu extrm{m}$)을 제작하였다. 제작된 초미세 탐침을 컴퓨터로 제어되는 스텝핑모터를 장착한 정밀 X, Y, Z stage에 부착하여서 수 $\mu\textrm{m}$간격의 탐침 삽입위치에 따라서 미세면방전 AC-PDP의 플라즈마 밀도 및 온도분포 특성을 진단하였다. PDP 방전공간에 초미세 랑뮈에 탐침을 삽입해서 -200~+200V의 바이어스 전압을 가해준다. 음의 바이어스 전압구간에서 이온 포화전류를 얻어내어 여기서 플라즈마 이온 밀도를 측정하고 양의 바이어스 전압구간에서 플라즈마 전자온도를 측정하면 미세면방전 AC-PDP 플라즈마의 기초 진단이 가능하다.

  • PDF

Experimental investigation of intrusive gravity current in stratified fluid (성층화된 유체 내에서 침입중력류의 실험적 연구)

  • Paik, Joong-Cheol;Son, Shin-Hye
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.173-173
    • /
    • 2012
  • 중력류는 두 유체 사이에서 물질의 종류 또는 온도차로 인한 밀도 차이에 의해 발생되는 유체의 흐름을 말하며, 자연환경에서는 저수지에서의 중층탁류, 사막에서의 모래 폭풍, 하구에서의 염수쐐기 등이 그 예이다. 여름철에 강우가 집중되는 우리나라는 홍수에 의한 범람, 침수 등이 발생할 뿐만 아니라 댐이나 하천, 호수 등에 흙탕물이 유입되어 중간층에 정체하는 중층탁류에 의한 피해가 자주 발생하고 있다. 과거에 중층탁류는 일시적인 현상에 불과하였으나 오늘날에는 인공적으로 형성된 정체성 호수나 하천에서 장기간 체류하여 생태계의 교란과 수질 악화를 초래하고 있다. 중층탁류에 의한 피해를 저감시키기 위해서는 본래 자연 상태의 하천이나 호수와 같이 온도분포가 비선형적으로 성층화 된 상태에서 탁수가 유입되어 중층탁류가 형성되는 과정과 흐름 특성을 이해하는 것이 선행되어야 한다. 본 연구에서는 중력류 흐름 해석을 위한 실험 장치를 개발하였다. 실험 장치 중 수조의 제원은 1200 $700{\times}300mm$이며, 수조 상부에는 가열장치를 설치하였고, 수조 하부에는 냉각장치를 설치하였다. 이들 장치들을 가동하여 깊이에 따른 자연현상에서의 비선형적인 온도 단면을 재현한다. 수리 실험방법은 깊이 방향으로 온도에 따라 비선형적으로 성층화 된 유체 내로 경사가 있는 판을 따라 수조내의 성층화된 유체의 중간 온도 혹은 밀도를 가진 유체를 침입시킨다. 침입유체는 성층화된 유체 내에서 초기에는 중력에 의해 운동량을 갖고 경사면을 따라 일정한 속도로 흘러내려 간다. 이후 바닥으로 하강 한 후 부력에 의해 상승하여 동일한 밀도층의 위치에서 횡방향으로 전파하게 된다. 이 연구에서는 이와 같이 비선형적으로 성층화된 유체 내에서의 침입 중력류의 흐름 특성을 실험적으로 관측하고 분석한다.

  • PDF

Distribution of lasmodiophora brassicae Causing clubroot Disease of Chinese Cabbage in Soil (배추무사마귀병균의 토양내 분포)

  • 김충회;조원대;김홍모
    • Research in Plant Disease
    • /
    • v.6 no.1
    • /
    • pp.27-33
    • /
    • 2000
  • Population density of Plasmodiophora brassicae in soil of severely infested fields of Chinese cabbage decreased as soil depth increases. More than 97% of total population was found in surface soil (0-5cm depth), and a few resting spores of the pathogen were also detected in 40 cm-deep soil. the clubroot pathogen was evenly distributed over the surface soil without clustering around a Chinese cabbage plant. Density of P. brassicae in soil at 23 Chinese cabbage fields in Pyongchang, Kangwon province ranged widely from less than 10$^4$resting spores/g soil to above 10$\^$6/ resting spores/g soil. Few or none of P. brassicae was found in virgin soil without any cropping history, intermediate with 0.36-2.75$\times$10$^4$resting spores/g soil in fields of other crops but more than 10 times higher population was found in severely infected Chinese cabbage fields. Density of P. brassicae was highest in the fields of monocropping of crucifers with some exceptions, but was low in rotated fields with corn, rye, medicinal crops or other non-host vegetables. Pathoen density in soil was decreased rapidly when rye or medicinal crops were cultivated after Chinese cabbage, suggesting that survival of clubroot pathogen appears to be influenced greatly by cropping system. The improved method for detecting resting spores of P. brassicae in soil used in this study seemed to be adequate for estimating population density of P. brassicae in soil in aspects of clearer dyeing, increased detecting sensitivity, and simplicity in preparation.

  • PDF

Stochastic Parameter를 가지는 집속 유동계에서의 선밀도 불균제 한계

  • Heo, Yu;Kim, Jong-Sung
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.54-54
    • /
    • 2004
  • 집속체의 드래프트 공정(롤러 인발 공정)의 경우, 선밀도의 변동성(irregularity)은 드래프트 비, 롤러 간격 등의 공정조건과 집속체, 응집도, 엉킴 등으로 대표되는 openness 애 큰 영향을 받는다. 본 연구에서는 유동계 내에서의 집속체 동적거동을 묘사하는 기본 방정식을 바탕으로 openness 와 직접적인 관련이 있는 구성모델의 주요 파라메타($\mu$)의 변동을 auto-covariance function 으로 묘사되는 확률과정 신호(stochastic signal)로 생각하여, 이 신호를 생성하고, 모델 시뮬레이션을 통하여 출력 집속체의 선밀도 변동을 살펴 보았으며, 출력 집속체의 선밀도가 거의 일정하게 유지되는 출력구간 근처에서 선밀도 불균제 특성을 해석하였다.(중략)

  • PDF

저밀도 유도 결합 플라즈마에서 전자 에너지 분포 측정

  • Gang, Hyeon-Ju;O, Se-Jin;Jeong, Jin-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.586-586
    • /
    • 2013
  • 저밀도 플라즈마는 반도체 공정, 나노 신소재 분야 및 우주 항공 분야 등 여러 분야에 이용되며, 플라즈마 진단 및 분석을 통해 효과적인 플라즈마 제어가 가능하다. 특히, 전자 에너지 분포 함수(Electron Energy Distribution Function, EEDF)는 전자 온도, 플라즈마 밀도 및 플라즈마 전위 등의 플라즈마 변수를 측정하거나 전자 가열 매커니즘 등을 이해하는데 있어서 매우 중요하므로 정밀한 측정이 필요하다. 그러나 RF fluctuation에 의해 낮은 전자 에너지 부분에서 EEDF가 왜곡되어 측정된 데이터 및 분석의 신뢰도가 떨어지게 된다. 이러한 문제점을 해결하기 위해 RF fluctuation 보상을 위한 쵸크 필터가 사용되며, 쉬스 임피던스에 비해 쵸크필터의 임피던스가 클수록 보상 효과는 높아진다. 하지만 플라즈마의 밀도가 낮아지면 쉬스 확장에 의해 쉬스 임피던스가 증가하므로 쵸크 필터에 의한 보상만으로는 충분한 개선 효과를 얻기 힘들다. 따라서 본 연구에서는 효과적인 RF fluctuation 보상을 위해 임피던스가 높은 쵸크 필터를 설계하고 추가적으로 레퍼런스링에 전압을 걸어 쉬스의 임피던스를 줄이는 방법도 적용하였다. 유도결합방식으로 $10^{-8}cm^{-3}$ 대의 저밀도 아르곤플라즈마 방전시켰으며, 단일 랑뮤어 탐침법으로 EEDF를 측정한 결과 낮은 전자 에너지 부분의 왜곡이 개선됨을 확인하였다.

  • PDF

다중 Mult-hole 전극을 이용한 RF Capcitively Coupled Plasma에서의 위치 별 밀도 제어에 관한 연구

  • Lee, Heon-Su;Lee, Yun-Seong;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.176-176
    • /
    • 2012
  • 다수 홀 전극을 이용한 RF Capcitively Coupled Plasma는, 평판 전극을 이용할 때에 비해, 전자 밀도를 향상시키는 것으로 알려져 있다. 이와 같은 전자 밀도의 증가는 일반적으로 공정의 속도를 증가시키며, 박막 태양전지의 Microcrystalline Silicon 증착 공정등 공정의 속도가 중요시되는 공정에서는 공정속도를 향상 시키는 것이 중요한 공정의 요구사항으로, 이와 같은 방법으로 전자 밀도를 향상시켜 공정의 속도를 향상시키는 연구가 진행되어 왔다. 그러나 공정에 사용하는 RF 전력의 파장의 유한성으로 인해, 공정의 면적을 증가시킬 경우, 방전의 균일도가 하락하게 되며 넓은 면적에 일정한 공정이 이루어지지 않게 되어 공정의 품질이 하락하게 된다. 이러한 문제에 대한 해결책의 하나로 본 발표에서는 다중 Multi-hole 전극을 이용한 방전을 제시하고자 한다. 다중 Multi-hole 전극은, 복수의 구획으로 나뉘어진 다수의 홀이 있는 전극으로 각각의 구획은 분리되어, 각 구획 별로 서로 다른 복수의 홀이 10 mm 깊이로 뚫린 전극 구획으로 나누어지며, 각 구획을 결합하여 하나의 전극을 이루도록 한 전극이며 이를 이용하여 위치 별 플라즈마 밀도를 제어하고자 하는 목적으로 설계되어진 전극 구조이다. 본 학회에서 발표하는 실험에서는 가장 단순한 형태인, 두 개의 구획으로 나뉘어진 전극을 이용하여 내부와 외부에, 평 전극 구획 혹은 5 mm 지름의 다수 홀이 존재하는 전극 구획을 조합하여 다양한 전극 구조를 만들었으며 이를 통해, 다중 Multi-hole 전극을 이용하는 위치 별 플라즈마 밀도의 제어 방법의 가능성을 확인하고자 하였다. 위치 별 플라즈마 밀도의 측정을 위해, 전극에 대해 수평하게 이동하는 RF compensated Single Langmuir Probe를 이용하여, 전자 밀도를 측정하였으며 50 mTorr의 낮은 압력 범위 및 500 mTorr의 높은 압력 범위에서 위치 별 플라즈마 밀도를 측정하여, 압력에 따라 달라지는 홀 방전의 특성을 이용하고자 하였다.

  • PDF

Effects of Foaming Agent on the Characteristic of Mortar (기포제(起泡劑)가 모르터의 특성(特性)에 미치는 영향(影響))

  • Kim, Seong Wan;Kang, Sin Up;Cho, Seong Seup;Sung, Chan Yong
    • Korean Journal of Agricultural Science
    • /
    • v.11 no.1
    • /
    • pp.133-145
    • /
    • 1984
  • To study the effect of foaming agent on the characteristic of mortar, the tests of water-cement ratio and bulk density of mortar were done under the different mixing ratio with G. U and J foaming agents. The results obtained were summarized as follows: 1. At the mixing ratio of 1 : 4 and 0.5% of foaming agent, the highest water-cement ratio was 90% by G, 88.3% by U and 70% by J foaming agent, respectively, being lower than 91.6% of that of cement mortar. 2. At the mixing ratio of 1 : 3 and 3.0% of foaming agent, the water-cement ratio was decreased up to 22.0% by G and 24.1% by U foaming agent, respectively, but it gradually was increased in richer and poorer mixing ratio. At the mixing ratio of 1 : 4 and 3.0% of foaming agent, the water-cement ratio was decreased up to 53.1% by J foaming agent, but it gradually was increased in richer mixing ratio. 3. At the mixing ratio of 1 : 1 and 0.5% of foaming agent, the highest bulk density was $1.981g/cm^3$ by G, $1.863g/cm^3$ by U and $1.149g/cm^3$ by J foaming agent, respectively, being lower than $2.048g/cm^3$ of that of cement mortar. 4. At the mixing ratio of 1 : 2 and 3.0% of foaming agent, the bulk density was decreased up to 20.7% by G, 23.7% by U and 56.5% by J foaming agent, respectively, but it gradually was increased in richer and poorer mixing ratio. 5. The water-cement ratio and bulk density were decreased in more addition of foaming agent, respectively, multiple regression equations of water-cement ratio and bulk density were computed depending on a function of mixing ratios and addition of foaming agents.

  • PDF