• Title/Summary/Keyword: 미소유체소자

Search Result 4, Processing Time 0.016 seconds

Electrical and Fluidic Characterization of Microelectrofluidic Bench Fabricated Using UV-curable Polymer (UV경화성 폴리머를 이용한 미소유체 통합접속 벤치 개발 및 전기/유체적 특성평가)

  • Youn, Se-Chan;Jin, Young-Hyun;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.475-479
    • /
    • 2012
  • We present a novel polymer fabrication process involving direct UV patterning of a hyperbranched polymer, AEO3000. Compared to PDMS, which is the most widely used polymer in bioMEMS devices, the present polymer has advantages with regard to electrode integration and fast fabrication. We designed a four-chip microelectrofluidic bench having three electrical pads and two fluidic I/O ports. We integrated a microfluidic mixer and a cell separator on the bench to characterize the interconnection performance and sample manipulation. Electrical and fluidic characterization of the microfluidic bench was performed. The measured electrical contact resistance was $0.75{\pm}0.44{\Omega}$, which is small enough for electrical applications, and the pressure drop was 8.3 kPa, which was 39.3% of the value in the tubing method. By performing yeast mixing and a separation test in the integrated module on the bench, we successfully showed that the interconnected chips could be used for bio-sample manipulation.

Effects of the surface roughness on Flow Characteristics in PDMS Microchannels (PDMS 마이크로채널 유체유동에 미치는 표면거칠기에 관한 연구)

  • Kim, Young-Min;Kim, Woo-Seung;Lee, Sang-Hoon;Baek, Ju-Yeoul
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1999-2004
    • /
    • 2004
  • Experiments were conducted to investigate the flow characteristics of water through rectangular PDMS microchannels with a hydraulic diameter ranging from 66.67 to 200 ${\mu}m$. In the experiments, the flow rate and pressure drop across the microchannels were measured at steady states. The experimental results were compared with the predictions from the conventional laminar flow theory. A significant difference between the experimental data and the theoretical predictions was found. Experimental results indicate that the pressure gradient and flow friction in microchannels are higher than those from the conventional laminar flow theory. This may be attributed to the fact that there exists effect of surface roughness of the microchannels. In this study, a surface roughness model is implemented to interpret the experimental data. A good agreement between the experimental data and the numerical predictions with a surface roughness model were found.

  • PDF

The Microfluidic Device using Viscosity Deviation of Magnetic Fluids Due to Temperature Changes (자성유체의 온도에 따른 점성 변화를 이용한 미소 유체 소자)

  • Choi, Bum-Kyoo;Oh, Jae-Geun;Ahn, Jeong-Jae
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.473-478
    • /
    • 2004
  • This study focused on the charateristic of magnetic fluids, the viscosity deviation of magnetic fluids due to temperature changes, and fabrication of a 'purely' liquid type microvalve. The viscosity of magnetic fluids decreases sharply during increasing of temperature. The viscosity of magnetic fluids is rated 1,000 cP at the room temperature and 25 cP when the temperature reaches $100^{\circ}C$. Briefly, it is remarkable that the fluid flow can be controlled by the temperature and this characteristic can be adopted to the microfluidics as a microvalve. The fabrication of a liquid type microvalve is more easy than solid state microvalves and which can increase an efficiency of the controlability with respect to the thermo-pneumatic micropump which is studied broadly for many years. When the magnetic fluid used as a sealant for high level sealing, the pressure leakage is less than solid state microvalve. The experimental results show that the pressure drop in microchannel, filled with the magnetic fluid, is significant in the temperature range of $20^{\circ}C{\sim}50^{\circ}C$ and this result explains why the use of magnetic fluids is possible as a microvalve searcher uses this characteristics. Well known thermo-pnumatic.

A Study on Heat Transfer Coefficient of a Perfluorocarbon Heat Pipe (Perfluorocarbon 히트파이프의 열전달 계수에 관한 연구)

  • 강환국;김철주;김재진
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.194-201
    • /
    • 1998
  • In electric commuter trains using AC motors, lots of GTO thyristors and diodes are needed for power controls. These semiconductors generate heat about 1~2 kW, and for cooling which perfluorocarbon(PFC) heat pipes have been in use for the last two decades. The present study was investigated on the effects of such important design parameters as structure of internal surface (grooved or smooth), fill charge ratio, and inclinating angle from a vertical on heat transfer coefficients at both evaporators and condensers. To obtain experimental data, several heat pipes of the same geometry of 520 mm long and diameter of 15.88 mm but different in fill charge ratio and internal surface structure were designed and fabricated. For prediction of the heat transfer coefficients, related expressions were examined and the results of calculations were compared with experimental data. Performance tests were conducted while heat pipes operated at mode of thermosyphons. High enhancements of heat transfer coefficient were obtained internal grooves. In these cases, the evaporating heat transfer coefficients distributed in the range of 2~5.5 kW/$m^2$K, with an increase of heat flux from 15~45 kW/$m^2$. These experimental data were in good agreement with Rohsenow's expression based on nucleate boiling when correction factor $C_R$=1.3 was encountered. In addition, the condensation heat transfer coefficients were distributed from 1.5 to 3.5 kW/$m^2$K, and the data were in good agreements with Nusselt's correlation, based on filmwise condensation on vertical plate, when choosing a correction factor $C_N=4$. A fill charge ratio of 40~100% were recommended, and the in clination angle effects were negligible when the angle was higher then 30$^{\circ}$.

  • PDF