• Title/Summary/Keyword: 미세 제어

Search Result 856, Processing Time 0.024 seconds

Remotely Controllable Smart Mobile System Using Arduino and Raspberry Pi for Infants

  • Park, Hyun-Wook;Shin, Young-Weon;Kim, Jin-Yeob;Kong, Ki-Sok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.11
    • /
    • pp.17-25
    • /
    • 2020
  • In this paper, we deal with a system that provides temperature, humidity and fine dust data around infants to parents through Arduino and Raspberry Pi. It controls the operation of the mobiles remotely through applications. Android applications can perform the following functions. First, the infant's surrounding temperature, humidity and fine dust data are received. Second, mobile controls the smart mobile remotely. Third, recording and playing the voices of parents and enhancing the convenience of parenting. Through the experiment of measuring the operating time of the remote control module, it was confirmed that the application can quickly access the system. Existing products on the market do not provide environmental information around the infants and application that has various functions. The system covered in this paper is expected to improve child-rearing convenience by providing parents environmental information around infants, remotely controllable function and convenient functions of the application.

실시간 고속 플라즈마 광 모니터링

  • Lee, Jun-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.82.2-82.2
    • /
    • 2013
  • 반도체 및 디스플레이 소자를 생산 하기 위하여 다양하고 많은 공정 기술이 사용 되며 그 중에서 플라즈마를 이용하는 제조공정이 차지 하는 부분은 상당한 부분을 차지 하고 있습니다. 전체 반도체 공정 중 48%가 진공공정이며, 진공공정 중 68% 이상이 플라즈마를 이용하고 있으며, 식각과 증착 장비 뿐만 아니라 세정과 이온증착 에 이르기 까지 다양하며 앞으로도 더욱 범위가 늘어 날 것으로 보입니다. 이러한 플라즈마를 이용한 제조 공정들은 제품의 생산성을 향상 하기 위하여 오염제어 기술을 비롯한 공정관리기술 그리고 고기능 센서기술을 이용한 공정 모니터링 및 제어 기술에 이르기 까지 다양한 기술들을 필요로 합니다. 플라즈마를 이용한 제조 장비는 RF파워모듈, 진공제어모듈, 공정가스제어모듈, 웨이퍼 및 글래스의 반송장치, 그리고 온도제어 모듈과 같이 다양한 장치의 집합체라 할 수 있습니다. 플라즈마의 생성과 이를 제어 하기 위한 기술은 제조장비의 국산화를 위한 부단한 노력의 결실로 많은 부분 기술이 축적되어 왔고 성과를 거두고 있습니다. 그러나 고기능 모니터링 센서 기술 개발은 그 동안 활발 하게 이루어져 오고 있지 않았으며 대부분 외산 기술에 의존해 왔습니다. 세계 반도체 시장은 현재 300 mm 웨이퍼 가공에서, 추후 450 mm 시장으로 패러다임이 변화될 예정이며, 미세화 공정이 더욱 진행 됨에 따라 반도체 제조사들의 관심사가 "성능 중심의 반도체 제조기술"로부터 "오류 최소를 통한 생산성 향상"에 더욱 주목 하고 있습니다. 공정미세화 및 웨이퍼 대구경화로 인해 실시간 복합 센서를 이용한 데이터 처리 알고리즘 및 자동화 소프트웨어의 기능이 탑재된 장비를 요구하고 있습니다. 주식회사 레인보우 코퍼레이션은 플라즈마 Chemistry상태를 정성 분석 가능한 OES (Optical Emission Spectroscopy)를 이용한 EPD System을 상용화 하여 고객사에 공급 중이며, 플라즈마의 광 신호를 실시간으로 고속 계측함과 동시에 최적화된 알고리즘을 이용하여 플라즈마의 이상 상태를 감지하며 이를 통하여 제조 공정 및 장비의 개선을 가능하게 하여 고객 제품의 생산성을 향상 하도록 하는 기술을 개발 하고 있습니다. 본 심포지엄에서는 주식회사 레인보우 코퍼레이션이 개발 중인 "실시간 고속 플라즈마 광 모니터링 기술" 의 개념을 소개하고, 제품의 응용 범위와 응용 방법에 대하여 설명을 하고자 합니다.

  • PDF

3D sensing and segmentation of microorganism using microfluidic device and digital holography (미세유체소자와 디지털 홀로그래피 기술을 이용한 미생물의 3D 이미징과 세그먼테이션)

  • Shin, Donghak;Lee, Joon-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.2
    • /
    • pp.447-452
    • /
    • 2013
  • Microfluidic devices can offer precise control for a verity of tasks involving biological specimen. In this paper, we propose an integrated system consisting of a microfluidic device along with a digital holographic microscope and present three-dimensional (3D) sensing and segmentation of biological microorganisms. When the individual microorganisms are inputted into the microfluidic channel, the holographic microscope records their holograms. The holograms are computationally reconstructed in 3D using Fresnel transform and the reconstructed phase images are used to search the position of microorganisms. Optical experiments are carried out and experimental results are presented to illustrate the usefulness of the proposed system.

Droplet-based Microfluidic Device for High-throughput Screening (액적 기반의 미세유체 시스템을 이용한 초고속 대용량 스크리닝)

  • Jeong, Heon-Ho;Noh, Young-Moo;Jang, Sung-Chan;Lee, Chang-Soo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.2
    • /
    • pp.141-153
    • /
    • 2014
  • Droplet based microfluidic systems have been developed for the application of biological and chemical research field. A picoliter droplet in microfluidic device provides a compartmentalized and well-defined reactor in miniaturized system. The microfluidic system with small droplets can reduce reagent cost and enhance efficiency through automated high-throughput screening system. In this review, we summarize the functionality of droplet based microfluidic system including droplet generation, precise droplet control, and various applications. In addition, this article reviews current applications in chemistry and biology, and discuss advantages of droplet based microfluidics compared with conventional manner.

Development of Wall Flow Sensor Using Micro Imaging Device (미세 영상 장치를 이용한 벽면 유동 센서 개발)

  • Lee, Seung Hwan;Kim, Byung Soo;Kim, Hyoung-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.12
    • /
    • pp.1217-1222
    • /
    • 2012
  • A wall flow sensor has been used for feedback flow control and wall shear stress measurement. In this study, we developed a new wall flow sensor by combining the PIV algorithm and the micro image sensor used in an optical mouse. The feasibility of the wall flow sensor was investigated by using simulated fluid flow experiments. Compared with the quadrature signal from imaging devices, the accuracy of the wall flow velocity measurement was improved and the dynamic range increased. In addition, the depth information of particles was also measured by using the defocusing imaging technique.