• Title/Summary/Keyword: 미세채널 유동

Search Result 52, Processing Time 0.025 seconds

Study on the Pressure Drop Characteristics of Liquid Flow in Open Microchannels with the Countercurrent Vapor Flow (기체 대향류가 존재하는 미소 액체 개수로 유동의 압력강하 특성에 관한 이론 및 실험적 연구)

  • Kim Sung Jin;Nam Myeong Ryong;Seo Joung Ki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.6 s.237
    • /
    • pp.747-754
    • /
    • 2005
  • Because the liquid-vapor interfacial shear stress affects seriously the liquid flow and the maximum heat transport rate of the grooved wick heat pipe, an accurate modeling for the pressure drop characteristics of the liquid flow is required. A novel method for calculating the liquid pressure drop and the velocity profile of an open channel flow in a microchannel with an arbitrary cross-section is suggested and validated by experiments. An experimental apparatus for the Poiseuille number of the liquid flow in open rectangular microchannels with the hydraulic diameters of 0.40mm, 0.43mm, 0.48mm is used in order to reproduce real situations in the grooved wick heat pipe. Analytic results from the suggested method are compared with the experimental data and they are in a close agreement with each other.

Experimental Study on the Aerodynamic Characteristics of a High-speed Ground Vehicle Moving in a Channel (채널 내를 운행하는 초고속 지상 운행체의 공력특성에 관한 실험적 연구)

  • Choi, Dong-Soo;Kim, Dong-Hwa;Cho, Jin-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.8
    • /
    • pp.72-81
    • /
    • 2004
  • A Wind tunnel test for a high speed ground vehicle was conducted to investigate the aerodynamic interactions between the vehicle and a solid channel. The free stream velocity was 30m/see and Reynolds number per unit length was $3.1{\times}10^5/m$. Experimental devices such as a variable channel ground and guide way were used for the test. As the vehicle was close to the channel ground and guide way, lift was significantly increased, drag was slightly decreased and pitching moments were restricted to augment static stability. Using smoke-wire, flow visualization was made to confirm these results by comparing the channel and non-channel flow characteristics of the vehicle. Under the influence of the channel ground and guide way, the flow beneath the vehicle was not discharged outside wing end plates, which was the major reason of the increase in lift of the vehicle.

Measurement of Zeta-potential of Electro-osmotic Flow Inside a Micro-channel (마이크로 채널 내부 전기삼투 유동의 Zeta-potential 계측)

  • Han Su-Dong;Lee Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.10 s.253
    • /
    • pp.935-941
    • /
    • 2006
  • Many important properties in colloidal systems are usually determined by surface charge $({\zeta}-potential)$ of the contacted solid surface. In this study, ${\zeta}-potential$ of glass ${\mu}-channel$ was evaluated from the electro-osmotic velocity distribution. The electro-osmotic velocity inside a glass f-channel was measured using a micro-PIV velocity field measurement technique. This evaluation method is more simple and easy to approach, compared with the traditional streaming potential technique. The ${\zeta}-potential$ in the glass ${\mu}-channel$ was measured fur two different mole NaCl solutions. The effect of an anion surfactant, sodium dodecyl sulphate (SDS), on the electro-osmotic velocity and f-potential in the glass surface was also studied. In the range of $0{\sim}6mM$, the surfactant SDS was added to NaCl solution in few different mole concentrations. As a result, the addition of SDS increases ${\zeta}-potential$ in the surface of the glass ${\mu}-channel$. The measured $\zeta-potential$ was found to vary from -260 to -70mV. When negatively charged particles were used, the flow direction was opposite compared with that of neutral particles. The ${\zeta}-potential$ has a positive sign for the negative particles.

Position Control of Micro Particles in a Fluid Flow Using Ultrasonic Standing Wave (정재초음파를 이용한 유동중 미세 입자 위치 제어)

  • Cho, Seung-Hyun;Seo, Dae-Cheol;Ahn, Bong-Young;Kim, Ki-Bok;Kim, Yong-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.131-136
    • /
    • 2008
  • Using ultrasonic standing waves, micro particles submerged or flowing in fluid can be manipulated. Due to acoustic radiation force of ultrasound, particles are forced to move to pressure nodal or antinodal lines. In this work, we propose a method to control the position of micro particle in a flow by adjusting the frequency of the standing wave. To this end, standing wave field generation system including a few millimeter thick micro channel was established using an immersible ultrasonic transducer. The present generation system works valid in a frequency range between 2.0 MHz and 2.5 MHz. We observed the SiC particles in water moved to pressure nodal lines by the standing wave. The effect of the channel thickness and operating frequency was also investigated. Interestingly, it was shown that the operating frequency have a close relation with the location of the pressure nodal line. Consequently, it fan be said that the position of particle movement rail be controlled by adjusting the ultrasound frequency. The maximum range of the controllable position was about 261 micrometers under the given condition. The resulted observations reveal the possibility of various applications of the ultrasonic standing wave to the manipulation of particles submerged in a fluid.

Flow Distribution and Heat Transfer Characteristic of the Microchannel Waterblock with Different Shape of Inlet (미세채널 워터블록의 유입부 형상에 따른 유량분배 및 열유동 특성)

  • Choi, Mi-Jin;Kwon, Oh-Kyung;Yun, Jae-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.7
    • /
    • pp.386-393
    • /
    • 2009
  • The present study has been studied on a thermal and flow characteristic of the microchannel waterblock with flow distributions in each channels. Results of a numerical analysis using the CFX-11 are compared with results of an experiment. Numerical analysis and experiment are conducted under an input power of 150 W, inlet temperature of $20^{\circ}C$ and mass flow rates of $0.7{\sim}2.0$ kg/min. Base temperature and pressure drop are investigated with standard deviations of mass flow rates in each channels of samples. The flow distribution and j/f factor of the sample 4 is increased by about 65.7% and 42.6%, compared to that of the reference model sample 3.

Study on Single-Phase Thermal and Hydrodynamic Characteristics in the Entry Region of a Mini-Channel Heat Sink (히트싱크 미세채널 내의 입구유동 영역에서의 단상 열유동 특성에 관한 연구)

  • Jang, Yong-Hee;Kim, Yong-Chan;Lee, Kyu-Jeong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.1007-1016
    • /
    • 2006
  • Although the advance in electronic technology enables a large number of circuity to be packed in a small volume, it is simultaneously required to remove the high heat load produced by them. In this study, the heat transfer and pressure drop characteristics of a mini-channel heat exchanger, which is designed for liquid cooling of electronic components, are investigated by varying operating conditions. Water and FC-72 were used as working fluids. The mini-channel heat exchanger was made with circular shape channels having din-meters of 2, 3, and 4 mm in regular intervals, and the channel length was 100 mm. The header and inlet guide pathway to provide uniform inflow were attached at the inlet of the test section. Copper block including the heaters was attached at the sidewall of the test section as a heat source, which provided the heat flux from 5 to $15W/cm^2$. The entrance effects enhanced the heat transfer coefficient in the mini-channel significantly. In addition, the single-phase pressure drop in the mini-channel was very similar to that predicted by the laminar flow correlation except that the transition Re decreased due to flow instability in the entrance region.

Droplet Bistability in Microchannel and its Application to Flow Control (마이크로 채널 내부에서의 액적의 쌍안정성과 이를 활용한 유동 제어)

  • Lee, Beom-Joon;Yoo, Jung-Yul
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.4
    • /
    • pp.43-47
    • /
    • 2010
  • We demonstrate the droplet bistability in a microchannel which has two symmetric necks that operate as capillary valves. It is shown that there are certain flow conditions, determined by droplet velocity and droplet size, to achieve bistability. Droplet bistabililty allows simple but precise control of droplet at a bifurcation channel. Therefore, by an appropriate channel design to induce droplet bistability, we can distribute droplets at a junction passively in the manner of perfect alternation and perfect switching in the choice of the outlets.

Analysis of 3-Dimensional Hydrodynamic Focusing in Circular Capillary Tube and Rectangular Microchannel (원형 모세관과 사각형 단면의 미세채널에서 3차원 수력학적 집속유동 분석)

  • Yoon, Seong-Hee;Kim, Kyung-Hoon;Kim, Jung-Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.2
    • /
    • pp.21-26
    • /
    • 2011
  • Hydrodynamic focusing technique to generate focused flow has been used for flow cytometry in microfluidic devices. However, devices with circular capillary tubes made of glass are not suitable for flow visualization or optical signal detection because the rays of light are distorted at the curved interface. We devised a new acrylic chamber assembled with a pulled micropipette and a rectangular microchannel made of glass. This new channel geometry enabled us to visualize the three-dimensional (3D) flow characteristics with confocal imaging technique. We analyzed the 3D hydrodynamic focusing in a circular capillary tube and a rectangular microchannel over a practical range of flow rates, viscosities and pressure drops.

Analysis of Electro-osmotic Flow in a Micro Channel Using a Micro PIV (마이크로 PIV 기법을 이용한 미세채널 내부 electro-osmotic 유동 해석)

  • Kim Yang-Min;Lee Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.51-52
    • /
    • 2002
  • Electro-osmotic flow in a PDMS microchannel of $66{\mu}m\;\times\;200{\mu}m\;\times\;3cm$ has been investigated using a micro PIV system. The field of view was $1056{\mu}m\;\times\;200{\mu}m$ and instantaneous velocity fields were obtained using two-frame cross-correlation method with $64\;\times\;64\;pixels^2$ interrogation window. In this study, we focused on the effect of applied electric field on the variation of internal flow with varying the electric field and seeding particles. The electro-osmotic flow shows a flat velocity profile and the mean velocity is proportional to the applied electric field.

  • PDF