DOI QR코드

DOI QR Code

Analysis of 3-Dimensional Hydrodynamic Focusing in Circular Capillary Tube and Rectangular Microchannel

원형 모세관과 사각형 단면의 미세채널에서 3차원 수력학적 집속유동 분석

  • 윤성희 (국민대학교 대학원 기계공학과) ;
  • 김경훈 (국민대학교 기계자동차공학부) ;
  • 김중경 (국민대학교 기계시스템공학부)
  • Received : 2011.05.15
  • Accepted : 2011.06.14
  • Published : 2011.06.30

Abstract

Hydrodynamic focusing technique to generate focused flow has been used for flow cytometry in microfluidic devices. However, devices with circular capillary tubes made of glass are not suitable for flow visualization or optical signal detection because the rays of light are distorted at the curved interface. We devised a new acrylic chamber assembled with a pulled micropipette and a rectangular microchannel made of glass. This new channel geometry enabled us to visualize the three-dimensional (3D) flow characteristics with confocal imaging technique. We analyzed the 3D hydrodynamic focusing in a circular capillary tube and a rectangular microchannel over a practical range of flow rates, viscosities and pressure drops.

Keywords

References

  1. Huh, D., Gu, W., Kamotani, Y., Grotberg, J. B. and Takayama, S., 2005, "Microfluidic for Flow Cytometric Analysis of Cells and Particles", Physiol. Meas., Vol.26, pp.R73-R98. https://doi.org/10.1088/0967-3334/26/3/R02
  2. Yoon, S., Cho, M. O. and Kim, J. K., 2010, "Visualization of Asbestos Fibers in Hydrodynamically Focused Flow", Proc. ISFV14, Daegu, Korea, pp.67.
  3. Di Carlo, D., 2009, "Inertial Microfluidics", Lab. Chip, Vol.9, pp.3038-3046. https://doi.org/10.1039/b912547g
  4. Choi, S. and Park, J. K., 2009, "Optically Coated Mirror-Embedded Microchannel to Measure Hydrophoretic Particle Ordering in Three Dimensions", Small, Vol.5, No.19, pp.2205-2216. https://doi.org/10.1002/smll.200900799
  5. Choi, S., Song, S., Choi, C. and Park, J. K., 2008, "Sheathless Focusing of Microbeads and Blood Cells Based on Hydrophoresis", Small, Vol.4, No.5, pp.634-641. https://doi.org/10.1002/smll.200700308
  6. Kim, Y. W. and Yoo, J. Y., 2008, "The Lateral Migration of Neutrally-Buoyant Spheres Transported Through Square Microchannels", J. Micromech. Microeng., Vol.18, No.6, pp.065015-13. https://doi.org/10.1088/0960-1317/18/6/065015
  7. Krishan, A., Krishnamurthy, H. and Totey, S., 2010, Applications of Flow Cytometry in Stem Cell Research and Tissue Regeneration, Wiley-Blackwell, New Jersey, pp.1-12.
  8. Hou, H. H., Tsai, C. H., Fu, L. M. and Yang, R. J., 2009, "Experimental and Numerical Investigation into Microflow Cytometer with 3-D Hydrodynamic Focusing Effect and Micro-Weir Structure", Electrophoresis, Vol.30, No.14, pp.2507-2515. https://doi.org/10.1002/elps.200900012
  9. Kim, J. K., Bang, H., Lee, Y., Chung, C., Yoo, J. Y., Yang, S. S., Kim, J. S., Park, S. and Chang, J. K., 2001, "Micro-imaging Techniques for Evaluation of Plastic Microfluidic Chip", J. Semiconductor Technol. and Sci., Vol.1, No.4, pp.239-247.
  10. Xuan, X. and Li, D., 2005, "Focused Electrophoretic Motion and Selected Electrokinetic Dispensing of Particles and Cells in Cross-Microchannels", Electrophoresis, Vol. 26, No. 18, pp.3552-3560. https://doi.org/10.1002/elps.200500298
  11. Yoon, S., Cho, M. O. and Kim, J. K., 2010, "Stability Analysis of Hydrodynamically Focused Flow Field in Rectangular Microchannel", Proc. NCFE6, Vol.2, pp.290-291.
  12. Knight, J. B., Vishwanath, A., Brody, J. P. and Austin, R. H., 1998, "Hydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds", Phys. Rev. Lett., Vol.80, No.17, pp.3863-3866. https://doi.org/10.1103/PhysRevLett.80.3863
  13. Kim, J. K., Chung, C., Chang, J. K. and Yoo, J. Y., 2003, "Analysis of Fully Developed Multilayer Flow in Microchannel with a Rectangular Cross Section", Trans. KSME B, Vol.27, No.5, pp.644-654. https://doi.org/10.3795/KSME-B.2003.27.5.644