• Title/Summary/Keyword: 미세성형

Search Result 577, Processing Time 0.03 seconds

ELECTRON MICROSCOPIC STUDY OF SLOWLY ADAPTING PERIODONTAL MECHANORECEPTIVE PRIMARY AFFERENT FIBERS WITHIN THE SUBNUCLEUS ORALIS OF THE CAT (서순응형 치근막 일차구심성 신경섬유 종말부의 Subnucleus oralis에서의 시냅스 양상에 관한 전자현미경적 연구)

  • Kim, Moo-Jung;Bae, Yong-Chul;Kim, Chin-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.15 no.4
    • /
    • pp.281-301
    • /
    • 1993
  • It was revealed that the morphology and projection pattern of terminal arbors from single primary afferent are different among distinct fiber types, functional types and the different subdivision of trigeminal sensory nucleus complex(TSNC). But it was not identified the ultrastructural morphology and synaptic connections of terminal arbors from each primary afferent within TSNC. So we employed the intra-axonal horseradish peroxidase(HRP) injection technique to define the terminal arbors of primary afferent fiber from slowly adapting mechanoreceptors in the periodontal ligament of the cat, and examined 66 labeled terminal arbors within the rostrodorsomedial part(Vo.r) of the trigeminal nucleus oralis, electromicroscopically with 90nm serial sections. All the boutons labelled with HRP contained clear, spherical and uniform sized synaptic vesicles(diameter : $47.66{\pm}3.58nm$ ). Most of the labelled boutons were boutons en passant type and they were connected by unmyelinated axonal strand. In which neurofilament and microtubule was not developed but occasionally contained synaptic vesicle in contrast to the myelinated axon. The size of the labelled bouton was relatively small(long diameter : $1.46{\pm}0.24{\mu}m$, short diameter $0.85{\pm}0.26{\mu}m$, average diameter $1.15{\pm}0.24{\mu}m$) and the shape of which varied from dome to elongated shape, but scalloped glomerulus shape was not developed. Each primary ending in Vo.r made synapse with one or two neuronal propiles(average : $1.11{\pm}0.31$), of which, 89.4% of labelled boutons made synapse with only one neuronal pro pile, the remainder, 10.6% of labelled boutons, made synapse with two neuronal propile. So characteristically they made very simple synapse. Most of labelled boutons(80.03%) made asymmetrical synapse only with dendritic shaft or spine, and 6.1% of labelled boutons received symmetrical synapse from pleomorphic vesicle containing axonal ending(p-ending). So presynaptic inhibiton was relatively scarce. Synaptic triad, in which a p-ending is presynaptic both pre-and post-synaptic element of the axo-dendritic contact from the labelled primary ending was not observed.

  • PDF

HARDNESS OF COMPOSITE RESIN CURED BY HIGH INTENSITY HALOGEN LIGHT (고강도 할로겐광으로 중합한 복합레진 수복재의 경도)

  • Park, Jong-Seok;Lee, Kwang-Hee;Kim, Dae-Eup;Kim, Seong-Hyeong;Ahn, Ho-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.471-479
    • /
    • 2001
  • The purpose of this study was to compare the effect of the high intensity halogen light $(850\sim1000mW/cm^2)$ with that of the conventional halogen light $(400mW/cm^2)$ on the hardness of composite resin. Three resin composites (Z-100, 3M, U.S.A. : Tetric Ceram, Vivadent, Liechtenstein; SureFil, Dentsply, U.S.A.) were filed in the stainless steel moulds which were 4mm in diameter and 2, 3, 4, and 5mm in depth, respectively. They were cured under the four different modes : (1) conventional mode, 40 seconds at $400mW/cm^2$; (2) 'ramp' mode, 10 seconds at 100 to $1000mW/cm^2$ plus 10 seconds at $1000mW/cm^2$; (3) 'boost' mode, 10 seconds at $1000mW/cm^2$; and (4) 'standard' mode, 20 seconds at $850mW/cm^2$. The surface hardnesses of the top and the bottom of the resin samples were measured with a microhardness tester (MXT70, Matsuzawa, Japan). The top surface hardness was not significantly different among the curing modes. The bottom surface hardness was generally the highest in the conventional mode and the lowest in the high intensity boost mode. There was no significant difference in the bottom surface hardness between the conventional mode and the high intensity standard mode in 2mm depth. The results suggest that the curing time of the high intensity halogen light $(850mW/cm^2)$ should be at least 20 seconds to produce the equal level of the bottom surface hardness of 2mm resin composite as compared to the hardness produced by the conventional halogen light $(400mW/cm^2)$.

  • PDF

Influence of Ca Reduction Process on the Properties of Nanocrystalline Nd-Fe-B Powders Prepared by a Thermochemical Process (열화학공정으로 제조된 나노결정형 Nd-Fe-B 분말의 특성에 미치는 Ca환원 공정의 영향)

  • Lee, Dae-Hoon;Jang, Tae-Suk;Yoo, J.-H.;Choi, C.-J.;Kim, B.-K.;Park, Byeong-Yeon
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.1
    • /
    • pp.42-47
    • /
    • 2005
  • Nanocrystalline Nd-Fe-B powder was synthesized by a new thermochemical process that combined with past reduction-diffusion process and spray-dry process. In this process, Ca reduction process is vary important due to formation of hard magnetic$Nd_{2}Fe_{14}B$ phase from various oxides by Ca powder. Therefore, the final products are essentially affected a shape, size, and composition etc. of the Ca reduced powders. Ca reduction was performed to way that raw powders just mixed with Ca powder in proper ratio unlike to compress into compact. The powders after mixture-type Ca reduction mainly composited with $Nd_{2}Fe_{14}B$ phase even relativily low reaction temperature ($800^{\circ}C$) and all particle size of powder were distributed less than 1 ${\mu}m$ except for powder after Ca oxides as magnetic properties of powders after cake-type Ca reduction, with the consequence that high magnetic properties has been expected. The magnetic properties of powders prepared by mixture-type Ca ruduction, with the conseqence that high magnatic properties has been expected. The magnetic properties of powders prepared by mixture-type Ca reduction process showed $_iH_c$ = 5.9 kOe, $B_r$ = 5.5 kG, (BH)max = $Nd_{2}Fe_{14}B{\to}Nd_{2}Fe_{17}B$ decomposition by violent exothermic reaction during washing.

Clinical Studies on Locally Invasive Thyroid Cancer (국소침범한 갑상선암의 임상적 고찰)

  • Kim Young-Min;Lee Chang-Yun;Yang Kyung-Hun;Rho Young-Soo;Park Young-Min;Lim Hyun-Jun
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.2
    • /
    • pp.236-243
    • /
    • 1998
  • Objectives: Local invasion of the thyroid cancer that is invasion of the upper aerodigestive tract, neurovascular structures of the neck and superior mediastinum, is infrequent and comprises of 1-16% of well-differentiated thyroid cancer. However the proximity of the thyroid gland to these structures provides the means for an invasive cancer to gain ready access into theses structures and when invasion occurs, it is the source of significant morbidity and mortality. So locally invasive thyroid cancer should be removed as much as possible, but still much debates have been exist whether the surgical method should be radical or conservative. This study was desinged to evaluate the clinical characteristics and the surgical treatment of the locally invasive thyroid cancer. Material and Methods: At the department of otorhinolaryngology of Hallym university, 10 patients diagnosed as locally invasive thyroid cancer among the 81 patients treated for thyroid cancer between 1991 to 1997 were retrospectively evaluated. Results: Of the 10 patients, 3 patients had histories of previous surgical treatment with or without radiation or radioactive iodine therapy. The site of invasion of thyroid cancer were trachea(7 cases), recurrent laryngeal nerve(5 cases), mediastinal node(5 cases), esophagus(3cases), larynx(3cases), carotid artery(3 cases), pharynx(l case), and other sites(4 cases). The operation techniques included 1 partial laryngectomy and 1 partial cricoid resection, 2 shavings and 3 window resections of the trachea, 1 sleeve resection of the trachea with end-to-end anastomosis and 1 cricotracheoplasty for tracheal invasion, 2 shavings and 1 partial esophagectomies for esophageal invasion, and 1 wall shaving and 2 partial resections with $Gortex^{\circledR}$ tube reconstruction for carotid artery invasion, and so on. Conclusions: These data and review of literature suggest that the surgical method should be perfomed on the basis of individual condition and complete removal of all gross tumor with preservation of vital structures whenever possible will offer a good result.

  • PDF

SURFACE HARDNESS OF THE DENTAL COMPOSITE CURED BY LIGHT THAT PENETRATE TOOTH STRUCTURE ACCORDING TO THICKNESS OF TOOTH STRUCTURE, LIGHT INTENSITY AND CURING TIME (치질을 투과한 조사광에 의한 복합레진 중합시 치질의 두께, 광세기 및 조사 시간이 복합레진의 표면 경도에 미치는 영향)

  • Cho, Soo-Kyung;Kim, Dong-Jun;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.128-137
    • /
    • 2005
  • In this study we measured the amount of light energy that was projected through the tooth material and analyzed the degree of polymerization by measuring the surface hardness of composites. For polymerization, Optilux 501 (Demetron, USA) with two types of light guide was used: a 12 mm diameter light guide with 840 nW/$cm^2$ light intensity and a 7 mm diameter turbo light guide with 1100 nW/$cm^2$. Specimens were divided into three groups according to thickness of penetrating tooth (1 mm, 2 mm, 0 mm). Each group was further divided into four subgroups according to type of light guide and curing time (20 seconds, 40 seconds). Vickers' hardness was measured by using a microhardness tester. In 0 mm and 1 mm penetrating tooth group, which were polymerized by a turbo light guide for 40 seconds, showed the highest hardness values. The specimens from 2 mm penetrating tooth group, which were polymerized for 20 seconds, demonstrated the lowest hardness regardless of the types of light guides (p < 0.05). The results of this study suggest that, when projecting tooth material over a specified thickness, the increase of polymerization will be limited even if light intensity or curing time is increased.

Developed an output device for high-frequency cosmetic medical equipment using micro multi-needle (마이크로 멀티니들을 이용한 고주파 피부미용 의료기기를 위한 출력 장치 개발)

  • Kim, Jun-tae;Joo, Kyu-tai;Cha, Eun Jong;Kim, Myung-mi;Jeong, Jin-hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.394-402
    • /
    • 2021
  • The entry of an aging society and the extension of human life expectancy, the increasing interest in women's social advancement and men's appearance, and the natural interest in K-culture through media media, while receiving worldwide attention, Focus on K-Bueaty. Recently, looking at the occupation of the medical tourism field, in the case of aesthetic medicine tourism such as molding and dermatology, it has gained popularity not only in Asia such as China and Japan, but also in North America and Europe. The first external confirmation of human aging is the wrinkles on the skin of the face. Clean, wrinkle-free, elastic and healthy skin is a desire of most people. Skin condition and condition such as focused ultrasonic stimulation (HIFU: High Intensity Focused Utrasound) and low frequency, high frequency (RF: Radio Frequency), galvanic therapy using microcurrent, cryotherapy using rapid cooling, etc. Depending on the method of management, the effect of the treatment differs depending on the output and the stimulation site, etc., even in the treatment of medical equipment and beauty equipment using the same mechanism. In this research, in order to develop invasive high-frequency dermatological devices using a large number of beauty medical devices and microneedles of beauty devices, the international standards IEC 60601-2 (standards for individual medical devices) and MFDS (Ministry of) We designed and developed a high-frequency output device in compliance with the high-frequency stimulation standard announced in the Food and Drug Safety (Ministry of Food and Drug Safety). The circuit design consists of an amplifier (AMP: Amplifier) using Class-A Topology and a power supply device using Half-Bridge Topology. As a result of measuring the developed high-frequency output device, an average efficiency of 63.86% was obtained, and the maximum output was measured at 116.7W and 50.67dBm.

A Study on Production Kiln Site Estimation, based on Historical Ceramic Characteristics and Scientific Analysis of the Celadons Excavated From the Beopcheon Temple Site and Son-gok 2-ri 4th Kiln Site (법천사지 청자와 손곡2리 4호 가마터 청자의 도자사적 성격과 과학적 분석을 통한 생산 가마터 추정 연구)

  • Lee, Byeong-hoon;Yun, Seok-in
    • Korean Journal of Heritage: History & Science
    • /
    • v.47 no.3
    • /
    • pp.24-41
    • /
    • 2014
  • Since the celadons excavated from the Son-gok 2-ri 4th kiln site are located in the Beopcheon temple site and at close range, the similarity to the celadons excavated from the Beopcheon temple site is being raised. Thus, this study examined the correlation using a natural-scientific method. In this study, historical ceramic properties of total 19 celadons were examined and they were scientifically analyzed. First of all, according to the scientific analysis, chemical compositions of celadon clay showed a dispersed distribution at RO2 3.79-7.77mole and RO+R2O 0.33-0.49mole. When the microstructure was analyzed, most celadons excavated from the Beopcheon temple site, Wonju, which are estimated to be used in real life, had a favorable state, and some celadons from the Son-gok 2-ri 4th kiln site were found not to be glazed and sintered properly. When analyzing body crystalline phases of the celadons using the XRD method, quartz and mullite were extracted from all of the samples. And corundum was extracted from sg4 sample. Though firing temperature of each sample was different, they were mostly fired to temperatures between 1150 and $1200^{\circ}C$ and some of them experienced a low temperature of $1100^{\circ}C$ or a high temperature above $1200^{\circ}C$. Various chemical compositions and producing techniques were observed in the celadons from the Beopcheon temple site and Son-gok 2-ri 4th kiln site and it is hard to assure that the Son-gok 2-ri 4th kiln site was the production kiln site of the celadons used in the Beopcheon temple site. But according to the analysis of rare earth elements, some of the celadons from the Beopcheon temple site and Son-gok 2-ri 4th kiln site displayed a distribution pattern with certain regularity and this implies there is a possibility that the raw materials used in producing the ceramics might have come from the same origin. From the perspective of ceramic history, the celadons excavated from the Beopcheon temple site and Son-gok 2-ri 4th kiln site were produced using the same molding and sintering technique. Also, it is estimated that they were produced in the 12th or 13th century, judging from the overall shapes and patterns of the celadons.