Development of Air Cleaning Roll-Filter for Improving IAQ in Subway (도시철도 객실 공기질 개선을 위한 롤필터 개발연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jong-Bum;NanGoong, Seok;Han, Tae-Woo;Cho, Kwan-Hyun;Kim, Tae-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.4
    • /
    • pp.313-319
    • /
    • 2011
  • In a modern society, various type of transportation modes are utilized, among them the subway system is the one of the main transportation mode which more than 7.21 million people ride a day in Seoul. Due to the increased interests on the indoor air quality (IAQ) of underground facilities, public concerns on IAQ of subway system are increasing also. Platform screen door (PSD) recently installed at the whole stations of Seoul subway and tunnel washing-out appeared to be effective in reducing particulate matters in the platform and tunnel. However there has not been any attempt to improve IAQ of subway cabin inside. Most technologies for removing airborne particulate matters are known to be difficult to adopt on the subway cabin due to the problem of maintenance cost. Therefore, the object of this study is a practical development of cabin air cleaning system which can reduce the concentration of airborne particles and harmful gases at the same time. In this paper, we focused on the development of particle removing system utilizing a roll-filter for increasing operating time of air filter. The prototype of system was designed and manufactured based on the numerical prediction results. For rollfilter device, 5 candidate filter materials were tested in point of particle collection efficiency and pressure drop. It was found that the electrically charged filter material showed the highest performance among them.

Size Distribution Characteristics of Particulate Matter Emitted from Cooking (조리과정에서 생성된 미세먼지의 크기분포 특성)

  • Joo, Sang-Woo;Ji, Jun-Ho
    • Particle and aerosol research
    • /
    • v.16 no.1
    • /
    • pp.9-17
    • /
    • 2020
  • The characteristics of particulate matter made from daily cooking at a Korean residential apartment house with three dwellers had been investigated for about 3 months. All data were recorded by an optical particle counter every minute at the kitchen. Types of cooking such as boiling, frying, and grilling that performed in the house were listed. Boiling only was used in 32% cases among total 234 meals. Frying and grilling were 14% and 11%, respectively. From an initial indoor particulate matter smaller than 10 ㎛ in diameter, the increases due to cooking are reported by size. In case of boiling, PM at 1-10 ㎛ size and under 1 ㎛ size little increased. Normally, particles from oil or combustion in a process of frying or grilling increased indoor PM. In a case of grilling, particle mass concentration in a region of 1-10 ㎛ in diameter increased as much as 295 ㎍/㎥. Mass concentration of particles smaller than 1 ㎛ increased as much as 33 ㎍/㎥.

Evaluation of Exposure Characteristics of Fine Dusts by Subway Lines (지하철역사의 호선별로 미세먼지의 노출특성에 대한 평가)

  • Hwang, Sung Ho;Kim, Jeong Oh
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.1
    • /
    • pp.71-76
    • /
    • 2017
  • Objectives: This study aimed to assess the environmental factors that affect particulate matters (PM10) and to compare with outdoor PM10 concentrations in an underground subway stations. Methods: The PM10 level was determined from May 2013 to September 2013 in the Seoul subway stations in four lines. PM mini-vol portable sampler sampler was used to collect PM10 for 6 hrs. Arithmetic means of PM10 concentrations with standard deviation (SD) were calculated. Paired t-test was used to compare the differences between indoor PM10 and outdoor PM10 concentrations with correlation analysis which was used to identify the association between indoor PM10 concentrations and environmental factors. Results: There were no different PM10 concentrations significantly between line 1, 2, 3 and 4 in an underground subway stations. Passenger number was positively associated with PM10 concentration while construction year was negatively associated with PM10 concentrations. Indoor PM10 concentrations were significantly higher than those in outdoor PM10 concentrations. PM10 concentrations were higher in the stations which were constructed before 1990s rather than the stations constructed after 1990s. Conclusion: PM10 levels in the underground subway stations varied greatly depending on the construction year. Therefore, it might need to be more careful management to the stations which constructed in before 1990s.

Regional Analysis of Particulate Matter Concentration Risk in South Korea (국내 지역별 미세먼지 농도 리스크 분석)

  • Oh, Jang Wook;Lim, Tea Jin
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.157-167
    • /
    • 2017
  • Millions of People die every year from diseases caused by exposure to outdoor air pollution. Especially, one of the most severe types of air pollution is fine particulate matter (PM10, PM2.5). South Korea also has been suffered from severe PM. This paper analyzes regional risks induced by PM10 and PM2.5 that have affected domestic area of Korea during 2014~2016.3Q. We investigated daily maxima of PM10 and PM2.5 data observed on 284 stations in South Korea, and found extremely high outlier. We employed extreme value distributions to fit the PM10 and PM2.5 data, but a single distribution did not fit the data well. For theses reasons, we implemented extreme mixture models such as the generalized Pareto distribution(GPD) with the normal, the gamma, the Weibull and the log-normal, respectively. Next, we divided the whole area into 16 regions and analyzed characteristics of PM risks by developing the FN-curves. Finally, we estimated 1-month, 1-quater, half year, 1-year and 3-years period return levels, respectively. The severity rankings of PM10 and PM2.5 concentration turned out to be different from region to region. The capital area revealed the worst PM risk in all seasons. The reason for high PM risk even in the yellow dust free season (Jun. ~ Sep.) can be inferred from the concentration of factories in this area. Gwangju showed the highest return level of PM2.5, even if the return level of PM10 was relatively low. This phenomenon implies that we should investigate chemical mechanisms for making PM2.5 in the vicinity of Gwangju area. On the other hand, Gyeongbuk and Ulsan exposed relatively high PM10 risk and low PM2.5 risk. This indicates that the management policy of PM risk in the west side should be different from that in the east side. The results of this research may provide insights for managing regional risks induced by PM10 and PM2.5 in South Korea.

The Correlation between Fine Dust(PM10, PM2.5) and The Number of Acute/Chronic Sinusitis Patients (미세먼지(PM10, PM2.5) 농도가 급성/만성 부비동염의 환자 수에 미치는 영향)

  • Jang, Young-Woo;Kim, Jeong-Yoon;Kim, Hye-Kyung;Lim, Seung-Hwan
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.31 no.3
    • /
    • pp.1-11
    • /
    • 2018
  • Objectives : The purpose of this study is to analyze the correlation between fine dust(PM10.5, PM2.5) and the number of acute/chronic sinusitis patients. Methods : A simple regression analysis was performed based on the concentration of PM10 and PM2.5 as independent variables and the number of acute/chronic sinusitis patients as dependent variables. Results : As a result of simple regression analysis, if PM10 increases by $1{\mu}g/m^3$, the number of acute sinusitis patients increases by 7,000.291(P<.001, 95%CI :4,951.983-9,048.600). If PM2.5 increases by $1{\mu}g/m^3$, the number of acute sinusitis patients increases by 17,524.476.(P<.001, 95%CI:9,728.725-25,320.228) In addition, PM10 increases by $1{\mu}g/m^3$, the number of acute sinusitis patients increases by 3,163.471 (P<.001, 95% CI:2,268.642-4,058.301). If PM2.5 increases by $1{\mu}g/m^3$, the number of chronic sinusitis patients increases by 8,651.644.(P<.001, 95%CI:5,115.697-12,187.592) Conclusions : Both PM10 and PM2.5 are correlated with changes in the number of sinusitis patients. PM2.5 has effect on the number of patients than PM10. PM10 is the highest correlation in their 50s, PM2.5 in their 60s and 70s.

Determination of Cholesterol, Fatty Acids and Polyaromatic Hydrocarbons in PM10 Particles Collected from Meat Charbroiling (고기구이 스모크에서 채취한 PM10입자에서 콜레스테롤, 지방산과 PAH의 분포)

  • Seo, Young-Hwa;Ko, Kwang-Youn;Jang, Young-Kee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.2
    • /
    • pp.155-164
    • /
    • 2010
  • Emission from biomass combustion such as meat charbroiling is an important source of organic aerosol. Since source profiles are necessary input profiles for source apportionment of aerosol by a chemical mass balance model, meat cooking organic source profiles are developed by measuring organic marker compounds, including palmitic acid, stearic acid, oleic acid and cholesterol as well as PAH compounds. Emissions from meat and pork charbroiling are collected on quartz filters with a PM10-high volume sampler, extracted with organic solvents, derivatized with diazomethane/TMS and analyzed by GC/MS isotope dilution method. Organic and elemental carbon are also analyzed by an OCEC analyzer. Wt.% of cholesterol to the organic carbon(OC) content from beef and pork charbroiling is only 0.056 and 0.062, but wt. % of all saturated fatty acids to the OC content from beef and pork charbroiling is 2.727 and 2.022, and the wt% of all unsaturated fatty acids to the OC content is 0.278 and 0.438, respectively. Content of total PAH compounds to the OC content from beef charbroiling is higher than that from pork charbroiling, and those are 0.116 wt% and 0.044 wt%. Among PAH compounds benzo(a)pyrene as a single compound is account for 0.0071 wt% and 0.0023 wt% of OC content from beef and pork charbroiling. Ratios of marker compound to cholesterol are calculated, and those values are in good agreement with the values already reported at the food cooking emission, indicating that they can be used as organic source profiles for the apportionment of organic aerosol.

Comparison of Simultaneous Measurements of $PM_{10}$ in Ambient Air (환경대기 중 미세먼지($PM_{10}$)의 동시측정 비교 연구)

  • 조석주;최금숙;여인학;이민환;김민영;김신도
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.267-268
    • /
    • 2003
  • 환경매계(environmental matrices)에 존재하는 오염물질의 농도측정과 관련된 측정의 객관성을 확보하기 위하여 가장 중요한 기준은 측정농도의 신뢰도를 확보하는 것을 들 수 있으며, 특히 토양이나 물과 달리 비정형화 된 매개인 대기 중에 존재하는 오염물질을 채취ㆍ분석하고 비교할 때, 분석화학적인 관점에서 객관성을 확보하고 유지하기 위해서는, 연구를 주관하는 모든 연구주체들이 기존 측정방식에 대한 철저한 검증을 시도하고, 이를 바탕으로 새로운 분석방식의 개발을 추진하는 것이 중요하다. (김기현 et al., 1999) (중략)

  • PDF

대구지역에서 배출된 1998년과 2004년의 대기오염물질배출량 비교 연구

  • Park, Myeong-Hui;Park, Min-Su;Kim, Hae-Dong
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2007.05a
    • /
    • pp.174-178
    • /
    • 2007
  • 본 연구에서는 1998년과 2004년의 대기오염물질배출량 분포를 비교하여 제시하였다. 결과는 아래와 같다. 첫 번째 오염물질별 배출량을 살펴보면 2004년이 1998년에 비해 질소산화물$(NO_x)$과 미세먼지(PM-10)은 증가하였고, 일산화탄소(CO)와 아황산가스$(SO_2)$는 감소하였다. 두 번째 오염원별 배출량을 살펴보면 1998년과 2004년 모두 모든 오염원에서 증가하는 경향을 보였으나 선 오염원의 배출량이 가장 뚜럿한 증가를 나타내었다. 이는 $SO_2$는 저황유 공급정책과 청정연료의 사용으로 인해 감소하였으며, $NO_x$와 PM-10 차량대수의 증가와 인구의 증가, 총에너지 수요의 증가가 원인으로 판단된다.

  • PDF

Application of Oryza sativa (Rice) Bran Oil as an Anti-pollution Cosmetic Material (쌀겨오일의 안티폴루션 화장품 소재로써의 응용)

  • Kang, Hae-Ran;Jung, So Young;Heo, Hyojin;Cha, Byungsun;Brito, Sofia;Lee, So Min;Yeo, Hye Lim;Yoo, Kyung Wan;Kwak, Jun Soo;Kwak, Byeong-Mun;Lee, Mi-Gi;Bin, Bum-Ho
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.3
    • /
    • pp.237-245
    • /
    • 2021
  • Particulate matter and ultra-particle matters generally refer to very small floating dust, such as 1/6 to 1/7 and 1/20 to 1/30, respectively, compared to the thickness of human hair, and contain various types of heavy metal ions. In addition to breathing, particle matters (PM) that flows in through the gaps in the pores of the skin can induce health problems in the body's tissues and skin, so it must be removed by blocking the inflow or by washing. Through this study, we confirmed the possibility that heavy metal ions can be adsorbed and removed by using Oryza sativa (Rice) bran oil (OSBO). In addition, the cell viability is much higher than that of grain-derived components through cytotoxicity experiments, and the cytoprotective effect of an external stimulus source can be expected. It was confirmed that the expression amount of COL1A1 mRNA increased, and accordingly, it was believed that wrinkles that might be caused by moisture lost by heavy metal ions in fine dust could be alleviated. Based on the results of these experiments, we tried to present a cosmetics containing OSBO, which is a wash-off formulation, in order to finally remove heavy metals.

Development of Environmental Safety Real-Time Monitoring System by Living Area (생활권역별 환경안전 실시간 모니터링 시스템의 개발)

  • Lee, Joo-Hyun;Kim, Joo-Ho;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1088-1091
    • /
    • 2019
  • In this paper, a real-time monitoring system for environmental safety by living area is proposed. The proposed system is designed to measure radiation, fine dust and basic living information (temperature) using fixed and mobile measuring equipment, and constitutes a web database that stores data received from the equipment. It also develops web programs for displaying received data on PCs and mobile phones. The results of testing the performance of the system by an authorized testing agency showed that the radiation measurement range was measured in the range of $10{\mu}Sv/h$ to 10mSv/h, which is comparable to the world's highest level, and that the accuracy was measured between ${\pm}6.7$ and ${\pm}8.7$ percent of the measurement uncertainty was measured and normal operation at or below the international standard of ${\pm}15$ percent. In addition, the temperature test was conducted on a section of $-20^{\circ}C$ to $50^{\circ}C$ and normal operation was confirmed in response to the temperature change. Stability of radiated electromagnetic waves was ensured by a suitable judgment. The product's testing in general and high and low temperature environments for about four months after the prototype was made confirmed to be more than five years of durability. The measurement range and accuracy of fine dust sensors are compared with those of companies that measure the air environment, and the performance level is similar through the air quality measurement register.