• Title/Summary/Keyword: 미세먼지(PM-10)

Search Result 553, Processing Time 0.031 seconds

Study of Magnetic Filtration for Subway MVAC Dust (지하철 공조실 미세먼지에 대한 자성포집연구)

  • Park, Hae Woo;Chung, Sang Gui;Jo, Young Min
    • Particle and aerosol research
    • /
    • v.11 no.2
    • /
    • pp.37-46
    • /
    • 2015
  • Dust particles, which inflow to the subway mechanical ventilation and air conditioning(MVAC) chamber, contain a fair amount of iron compounds, approximately 25.2w/w%. This work attempted to capture those iron containing dust using magnetic filters. Average magnetization value of the test MVAC dust was 0.012 emu on 5,000 Oe, which could correspond sufficiently with the magnetic interaction. External permanent magnets provided with magnetization of iron mesh screen showing high gradient magnetic field(HGM). It resulted in the capture efficiency with 84.0 ~ 99.7% and 81.2 ~ 99.8% for $PM_{10}$ and $PM_{2.5}$ respectively. Magnetic capture was found to be closely associated with the magnetic intensity, mesh opening size and flow velocity.

Characteristics of Time Variations of PM10 Concentrations in Busan and Interpreting Its Generation Mechanism Using Meteorological Variables (부산 지역 미세먼지 농도의 시간변동 특성 및 기상인자 분석을 통한 먼지생성 해석)

  • Kim, Ji-A;Jin, Hyung-Ah;Kim, Cheol-Hee
    • Journal of Environmental Science International
    • /
    • v.16 no.10
    • /
    • pp.1157-1167
    • /
    • 2007
  • In an effort to interpret the characteristics of fine particle concentrations in Busan, time variations of hourly monitored concentrations $PM_{10}$ (Particulate Matter with aerodynamic Diameter ${\le}10\;{\mu}m$) in Busan are analyzed for the period from 2000 to 2005. The characteristics of aerosol second generation formation process is also interpreted qualitatively, by using the statistical analysis of the meteorological variables including temperature, wind speed, and relative humidity. The result shows some significant annual, seasonal, weekly and diurnal variations of $PM_{10}$ concentrations. In particular, seasonal(i.e., spring) variations are governed by frequency of yellow sand events even for the non-yellow sand cases where yellow-sand days are eliminated in our analysis. However, in seasonal variation, summer season predominate lower $PM_{10}$ concentrations due to the frequent precipitation, and weekly and diurnal variations are both found to be reflecting the emission rate from traffic amount. Correlation coefficients between $PM_{10}$ concentration and meterological variables for non-yellow sand days show overall negative correlation with visibility, wind speed, cloud amounts, and relative humidity. However for non-precipitation days, during non-yellow sand period positive correlation are found clearly with relative humidity, suggesting the importance of secondary aerosol formation in Busan that can be achieved by both homogeneous aerosol formation and heterogeneous transformations resulting from hygroscopic aerosol characteristics.

Statistical Analysis of PM10 and Meteorological Data in Pohang, a Steel-Industrial City (철강 산업도시 포항의 미세먼지 농도 및 관련 기상자료에 대한 통계적 분석)

  • Choi, Min-Suk;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.3
    • /
    • pp.329-341
    • /
    • 2016
  • Pohang is a well-known industrial city in Korea with a large steel-industrial complexes. The biggest environmental issue in the city is associated with fine particulate matter (hereinafter, $PM_{10}$). The concentration of $PM_{10}$ is generally dependent on the local emission sources and meteorological conditions. Iron and steel industrial complexes are likely serious pollution sources of $PM_{10}$ in Pohang. In this study, daily $PM_{10}$ data from a large database from the year of 2000 to 2012 were statistically analyzed, together with meteorological data. The average concentrations of $PM_{10}$ were evaluated according to the frequency of Asian dust, haze, mist, and fog. The number of days exceeding short-term standard for $PM_{10}$ were also examined, taking into consideration of weather conditions. It was found that the concentration of $PM_{10}$ was reduced about 18% to 26% because of precipitation. In addition, the effects of wind direction and wind speed on the $PM_{10}$ concentrations were investigated.

Stabilizing Soil Moisture and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System Controlled by Humidifying Cycle (가습 주기에 따른 벽면형 식물바이오필터의 토양 수분 안정화 및 실내공기질 정화)

  • Lee, Chang Hee;Choi, Bom;Chun, Man Young
    • Horticultural Science & Technology
    • /
    • v.33 no.4
    • /
    • pp.605-617
    • /
    • 2015
  • The ultimate goal of this research is to develop a botanical biofiltration system that combines a green interior, biofiltering, and automatic irrigation to purify indoor air pollutants according to indoor space and the size of biofilter. This study was performed to compare the stability of air flow characteristics and removal efficiency (RE) of fine dust within a wall-typed (vertical) botanical biofilter depending on humidifying cycle and to investigate RE of volatile organic compounds (VOCs) by the biofilter. The biofilter used in this experiment was designed as an integral form of water metering pump, water tank, blower, humidifier, and multi-level planting space in order to be suitable for indoor space utilization. As a result, relative humidity, air temperature, and soil moisture content (SMC) within the biofilter showed stable values regardless of three different humidifying cycles operated by the metering pump. In particular, SMCs were consistently maintained in the range of 27.1-29.7% during all humidifying cycles; moreover, a humidifying cycle of operating for 15 min and pausing for 45 min showed the best horizontal linear regression (y = 0.0008x + 29.09) on SMC ($29.0{\pm}0.2%$) during 120 hour. REs for number of fine dust (PM10) and ultra-fine dust (PM2.5) particles passed through the biofilter were in the range of 82.7-89.7% and 65.4-73.0%, respectively. RE for weight of PM10 passed through the biofilter was in the range of 58.1-78.9%, depending on humidifying cycle. REs of xylene, ethyl benzene, total VOCs (TVOCs), and toluene passed through the biofilter were in the range of 71.3-75.5%, while REs of benzene and formaldehyde (HCHO) passed through the biofilter were 39.7% and 44.9%, respectively. Hence, it was confirmed that the wall-typed botanical biofilter suitable for indoor plants was very effective for indoor air purification.

Chemical Mass Composition of Ambient Aerosol over Jeju City (제주시 지역 미세먼지의 변동과 화학적 구성 특성)

  • Lee, Ki-Ho;Kim, Su-Mi;Kim, Kil-Seong;Hu, Chul-Goo
    • Journal of Environmental Science International
    • /
    • v.29 no.5
    • /
    • pp.495-506
    • /
    • 2020
  • This study investigated the nitrate formation process, and mass closure of Particulate Matter (PM) were calculated over the urbanized area of Jeju Island. The data for eight water-soluble inorganic ions and nineteen elements in PM2.5 and PM10 were used. The results show that the nitrate concentration increased as excess ammonium increased in ammonium-rich samples. Furthermore, nitrate formation was not as important in ammonium-poor samples as it was in previous studies. According to the sum of the measured species, approximately 45~53% of gravimetric mass of PM remained unidentified. To calculate the mass closure for both PM2.5 and PM10, PM chemical components were categorized into secondary inorganic aerosol, crustal matter, sea salt, trace matter and unidentified matter. The results by the mass reconstruction of PM components show that the portion of unidentified matter was decreased from 52.7% to 44.0% in PM2.5 and from 45.1% to 29.1% in PM10, despite the exclusion of organic matter and elemental carbon.

Development and Performance Evaluation of a Real-time PM Monitor based on Optical Scattering Method (광산란방식을 이용한 미세먼지 실시간 모니터링 장치 개발 및 성능평가)

  • Kang, Doo Soo;Oh, Jung Eun;Lee, Sang Yul;Shin, Hee Joon;Bong, Ha Kyung;Kim, Dae Seong
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.107-119
    • /
    • 2018
  • In this study, we have developed a real-time monitoring device for measuring PM10 and PM2.5 of ambient aerosol particles. The real-time PM monitor (SENTRY Dust Monitor) uses the optical scattering method and has 16 channels in particle size. The laboratory and field tests were carried out to evaluate the developed SENTRY Dust Monitor. Arizona Test Dust particles were used as test particles in the laboratory test and the field test was carried out at the Jongno-gu Observatory in Seoul. The measurements of PM10 and PM2.5 concentrations obtained by SENTTRY Dust Monitor were compared with Grimm Dust Monitor (Model 1.108) and a beta ray gauge. It was shown that the PM10 and PM2.5 concentrations obtained by SENTRY Dust Monitor agree well with that of the reference devices. Based on the results obtained in this study, it could be concluded that the SENTRY Dust Monitor can be used as a PM monitoring device for real-time monitoring of the ambient aerosols.

A Correlation Analysis between Visibility and PM10 in Jinju (진주지역 시정과 미세먼지(PM10) 농도와의 상관관계)

  • Kim, Hyoung-Kab;Suh, Jeong-Min;Park, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.26 no.4
    • /
    • pp.535-542
    • /
    • 2017
  • This study was conducted to investigate how $PM_{10}$ concentration and Relative Humidity (RH) affected visibility in Jinju, Korea. A 9-yr dataset of 1 h averages for visibility, $PM_{10}$, and RH data was analyzed to examine the correlation between these variables. On average, visibility decreased by 1.4 km for every $10{\mu}g/m^3$ increase in $PM_{10}$ and by 2.1 km for every 10% increase in RH. In general, a negative correlation was observed between visibility and and $PM_{10}$ concentration. However, under conditions of low $PM_{10}$ concentration(< $15{\mu}g/m^3$) and visibility(< 2 km), there was a positive correlation between these two variables. In this case, RH levels were high (> 75%). A high correlation analysis between two variables need to be under control conditions with RH < 75%, $PM_{10}$ $15{\sim}100{\mu}g/m^3$, and visibility > 2 km.

Ionic Compositions of Fine Particulate Matter during Summer and Winter in the Downtown Area of Jejusi City in Jeju Island (제주시 도심지역에서 여름철과 겨울철의 미세먼지 중 수용성 이온 조성)

  • Lee, Ki-Ho;Kim, Su-Mi;Hu, Chul-Goo
    • Journal of Environmental Science International
    • /
    • v.26 no.5
    • /
    • pp.591-600
    • /
    • 2017
  • This study was carried out to elucidate the chemical compositions of water-soluble inorganic ions in $PM_{10}$ and $PM_{2.5}$ aerosols collected during summer and winter in downtown Jejusi city. The ratios of $NO_3^-$ to the total mass of ionic species in $PM_{10}$ and $PM_{2.5}$ aerosols largely increase in winter compared to summer, while $SO_4^{2-}$ ratios in both aerosols appear to follow the opposite trend. Moreover, concentrations of $Na^+$, $Mg^{2+}$, $Ca^{2+}$ and $Cl^-$ in $PM_{10}$ and $PM_{2.5-10}$ aerosols are higher in winter than in summer. The nitrate concentrations in $PM_{10}$ and $PM_{2.5}$ aerosols increase with an identical increase in excess ammonium during winter, however, nitrate formation during summer is not important owing to ammonium-poor conditions.

Granger Causality between Thermal Environment and PM10 of Seoul's 25 Districts (서울특별시 25개 자치구의 열환경과 미세먼지 간 Granger 인과관계)

  • Youn, Jee Min;Kim, Hyungkyoo
    • Journal of Environmental Science International
    • /
    • v.31 no.1
    • /
    • pp.9-21
    • /
    • 2022
  • Today's cities require deeper understanding of the thermal environment and PM10 as their management becomes more critical. Based on these circumstances, this study investigated the Granger causality between the thermal environment and PM10 of the 25 districts of Seoul, the most populous and urbanized city in Korea. The results of the Granger causality test on the thermal environment and PM10 were classified into 12 types. Except for type 12, the temperature and urban island heat intensity of the other 11 types operated as a Granger-cause to each other in both directions. Temperature operates as a Granger-cause of urban island heat intensity in type 12. The PM10 level and urban pollution island intensity operated as a Granger-cause to each other in all districts. For types 1 and 2, thermal environment operated as a Granger-cause to PM10 in one direction, and type 3-type 12 confirmed that thermal environment and PM10 operated as a Granger-cause in both directions. Findings reveal the intricate causalities between thermal environment and PM10 at the district level and suggest mitigation strategies that are more location based.

Meteorological Characteristics of the Wintertime High PM10 Concentration Episodes in Busan (부산지역 겨울철 고농도 미세먼지 발생일의 기상학적 특성)

  • Jeon, Byung-Il
    • Journal of Environmental Science International
    • /
    • v.21 no.7
    • /
    • pp.815-824
    • /
    • 2012
  • The purpose of this study was to analyze the meteorological characteristics of wintertime high PM10 concentration episodes in Busan. $PM_{10}$ concentration has been reduced for the past four years and recorded near or exceeded 100 ${\mu}g/m^3$ (national standard of $PM_{10}$). High concentration episodes in Busan were 6 case, $PM_{2.5}/PM_{10}$ ratio was 0.36~0.39(mean 0.55). High $PM_{10}$ concentration occurred during higher air temperature, more solar radiation and sunshine, lower relative humidity, and smaller cloud amount. Synoptically, it also occurred when Busan was in the center or the edge of anticyclone and when sea breeze intruded. An analysis of upper air sounding showed that high $PM_{10}$ concentration occurred when surface inversion layer and upper subsidence inversion layer existed, and when boundary layer depth and vertical mixing coefficient were low. An analysis of backward trajectory of air mass showed that high $PM_{10}$ concentration was largely affected by long range transport considering that it occurs when air mass is intruded from China.