• Title/Summary/Keyword: 미분탄연소

Search Result 93, Processing Time 0.022 seconds

Analysis of Group Ignition of Pulverized Coal Particles (미분탄의 집단점화 해석)

  • Suh, K.K.;Kim, H.Y.
    • Journal of the Korean Society of Combustion
    • /
    • v.4 no.2
    • /
    • pp.1-10
    • /
    • 1999
  • Pulverized coal is widely used as the source of electrical power generation and industrial processes. Numerical analysis on the transient ignition process of the cloud of pulverized coal particles in various cases is carried out. Particle radius, initial particle temperature, number density are chosen as major parameters that influence the characteristics of ignition and combustion. The result can be summarized as follow. The ignition occurs at the position that is closed to the surface of the cloud. Maximum temperature and velocity appear at ignition point, and the concentrations of gaseous fuel and oxidizer decrease rapidly near the ignition point. The chemical reaction takes place in wider zone as number density and particle radius decrease. The ignition delay is shortest when particle radius is about $50\;{\mu}m$, and tends to be shorter as number density and initial ambient temperature increase.

  • PDF

NOx Reduction Characteristics of Air Staging Burner for Pulverized-coal Combustion (공기 다단공급식 미분탄 버너의 NOx 저감 특성)

  • Park, Chu-Sik;Kim, Sung-Won;Choi, Snag-Il
    • 한국연소학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.153-160
    • /
    • 2001
  • The combustion test used DTF was performed to obtain the characteristics of NOx emission and reduction. In this test, major factor of NOx emission was a stoichiometric air ratio. At the onset of combustion to be rich oxygen, NOx was produced rapidly. Optimum condition for NOx reduction was formed under about AR:0.7 in the combustion test of Alaska coal. Investigations were undertaken with 200KW(th) test combustor. In combustion test, the major variables were coal feed ratio of center/outer, stoichiometric air ratio at the onset of combustion. The lowest NOx emission, 182ppm(6% O2 base), was achieved at about AR:0.6 of the first combustion stage with low NOx burner. Also, unburned carbon content of char collected in this combustion condition was about 1wt%.

  • PDF

Evaluation of the empirical and structural coal combustion models in the IFRF no.1 Furnace (미분탄 탈휘발 및 촤반응 모델 평가)

  • Joung, Daero;Han, Karam;Huh, Kang Y.;Park, Hoyoung
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.217-219
    • /
    • 2012
  • This study describes 3D RANS simulation of a 2.1 MW swirling pulverized coal flame in a semi-industrial scale furnace. The simulation of pulverized coal combustion involves various models for complex physical processes and needs information of pyrolysis rate, the yields and compositions of volatiles and char especially in coal conversion. The coal conversion information can be acquired by the experiment or the pre-processor code. The empirical model based on the experiment of the IFRF and the structural model based on the pre-processor code of the PC-COAL-LAB were evaluated against the measurement data.

  • PDF

Numerical Study on the Devolatilization models of Pulverized Coal in DTF (DTF 내 미분탄 휘발화 모델에 관한 수치적 연구)

  • Kim, Jin-Nam;Kim, Ho-Young
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.173-184
    • /
    • 2002
  • In order to evaluate the devolatilization models of pulverized coal, various devolatilization models are examined for the numerical analysis of Drop Tube Furnace.The results of analysis are compared with the experimental results. A numerical study was conducted to explore the sensitivities of the predictions to variation of the model parameters. It helps to elucidate the source of the discrepancies. Three different wall temperature conditions of the DTF, 1100, 1300 and $1500^{\circ}C$ were considered in this analysis. Two fuels are U.S.A. Alaska coal and Australia Drayton coal. The results of analysis with constant rate model, single kinetic rate model and two competing rate modes well presented fast volatile matter release in the early devolatilization. However, in the latter devolatilization they did not coincide with experimental results which presented tardy volatile matter release on account of pyrolysis of high molecular substance. On the other hand, the results of analysis with DAEM(Distribute Activation Energy Model) coincided with experiment al results in overall devolatilization.

  • PDF

Pulverized Coal Injection System Development to Raise Combustion Efficiency of a Blast Furnace (고로미분탄 취입랜스의 연소효율 향상을 위한 노즐 제어의 최적화)

  • Choi, Seung-Hyun;Kwak, Na-Soo;Kim, Jae-Yeol
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.690-696
    • /
    • 2009
  • This paper introduces the automatic fine Bituminous Coal injection lance position control method using flame image process. The fine Coal injection lance is used to supply additional heat into the furnace in Mill plant. It injects fine coal into high pressured air flow and produces very heated and high pressured flame. For the such high temperature and pressure, the fine coal injection lance effects not only efficiency of burner but also furnace abrasion. To keep efficient combustion status and to avoid the abrasion, in this paper, the flame is monitored by computer image process. This paper proposes the flame image process method and lance position control according to calculated result for flame image process.

  • PDF

Approach to Reduce CO2 by Renewable Fuel Cofiring for a Pulverized Coal Fired Boiler (신재생연료 혼소를 통한 미분탄 화력 발전소의 CO2 저감 방안 도출)

  • Kim, Taehyun;Choi, Sangmin;Yang, Won
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.19-20
    • /
    • 2013
  • The cofiring of renewable fuel in coal fired boilers is an attractive option to mitigate $CO_2$ emissions, since it is relatively low cost option for efficiently converting renewable fuel to electricity by adding biomass as partial substitute of coal. However, it would lead to reduce plant efficiency and flexibility in operation, and increase operation cost and capital cost associated with renewable fuels handling and firing equipment. The aim of this study is to investigate reduction of carbon dioxide at varying percentage of biomass in fuel blend to the boiler biomass, and estimate operation and capital cost. Wood pellet, PKS (palm kernel shell), EFB (empty fruit bunch) and sludge are considered as a renewable fuels for a cofiring with coal. Several approaches by the cofiring ratio are chosen from past plant demonstrations and commercial cofiring operation, and they are evaluated and discussed for CO2 reduction and cost estimation.

  • PDF

Study on Coal Combustion Characteristics with 1MWth Test Facility (1MWth 실험연소로를 이용한 석탄의 연소특성 연구)

  • Jang, Gil Hong;Chang, In Gab;Jeong, Seok Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1464-1472
    • /
    • 1999
  • Design and operation of $1MW_{th}$ pulverized coal combustion testing facility are described. Also the influence of air staging on NOx emission and burnout of coal flames was investigated in this facility. The test facility consisted of coal feeding system, firing system and flue gas treatment system. A top-fired externally air staging burner was adopted in order to avoid influence of gravity on the coal particles and for easy maintenance. Distribution of temperature and chemical species concentration of coal flames could be measured in vertical pass of furnace. Main fuel was pulverized (83.4% less than $80{\mu}m$) Australian high bituminous coal. From variety of test conditions, overall excess air ratio was selected at 1.2(20% excess air). Tho study showed that increasing the staged air resulted in lower NOx omission, and it was suggested to be more than 40% of the total combustion air for the substantial NOx reduction. Sufficient burnout was not achievable when NOx emission was less than 500ppm. Also, the amount of core air did not influence tho NOx reduction.

Thermal Decomposition and Combustion Behavior of Plastics into Blast Furnace (플라스틱의 高爐 吹入時 熱分解特性 및 燃燒擧動)

  • 허남환;백찬영;임창희
    • Resources Recycling
    • /
    • v.9 no.6
    • /
    • pp.15-22
    • /
    • 2000
  • There are many intensive efforts to develop the recycling technologies of waste plastics in steel works to tackle the saving of resources and the protection of the natural environment. In this study, the thermogravimetric analyses for three kinds of plastics, the combustion experiments and the theoretical approach for calculating the flame temperature in the blast furnace had been performed to understand the behavior of plastics in the raceway. The thermal decompositions of plastics were studied using thermogravimetric analyzer under the atmospheric condition. The starting temperature of thermal decomposition and the maximum weight loss point were increased in proportion to the logarithmic values of heating rate. The combustion characteristics of plastics were simulated in a coke-bed combustor. The combustion efficiency of plastics was lower than that of pulverized coal. The oxygen enrichment was found out to be one of the useful methods to increase the combustibility of plastics in raceway. The maximum injection rate of plastics was calculated based on the flame temperature.

  • PDF

Numerical Study of the Optimization of Combustion and Emission Characteristics of Air-Staged Combustion in a Pulverized Coal-Fired Boiler (석탄 화력 보일러의 공기 다단공급방식을 통한 연소 및 배기 배출물 특성 최적화에 관한 수치해석 연구)

  • Yoon, Min-Ji;Lee, Byoung-Hwa;Song, Ju-Hun;Kim, Gyu-Bo;Chang, Young-June;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.6
    • /
    • pp.587-597
    • /
    • 2010
  • Air-staged combustion is known to be one of the techniques of NOx reduction. The objective of this study is to determine the optimal ratio of air flow distributed for CCOFA and SOFA; at this optimal ratio, the combustion and exhaust emission characteristics of a pulverized coal-fired boiler are maintained at a satisfactory level. A numerical investigation was performed at various airflow ratios of 16.7/83.3%, 25/75%, 50/50%, 75/25%, and 83.3/16.7%. An inert gas was considered as a substitute for air to isolate the effects of the cooling process and chemical reaction on NOx reduction; during NOx reduction in air-staged combustion, both the effects typically occur simultaneously. The results of our study show that the optimum condition, under which the maximum NOx reduction and highest boiler efficiency can be obtained, corresponds to the equal splitting of the over-fire air between CCOFA and SOFA.