• Title/Summary/Keyword: 미끄럼저항계수

Search Result 22, Processing Time 0.033 seconds

The Effect of Floor Slipperiness on Gait Characteristic (바닥의 미끄럼 저항이 보행 특성에 미치는 영향)

  • Kim, Tack-Hoon;Han, Seok-Kyu;Choi, Soo-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.1
    • /
    • pp.133-141
    • /
    • 2015
  • The floor slipperiness is an essential property for the pedestrian safety. This study was conducted to develop the slip test apparatus to be well accorded with actual characteristics of human gait; and the correlation between RCOF (Required coefficient of friction), Rz (Surface roughness), and 3 coefficients of slip resistance (C.S.R (Coefficient of slip resistance), BPN (British pendulum number), and SCOF (Static coefficient of friction)) were analyzed. Result of the analysis revealed that the cadence, stride length, and step length were proportional to the walking speed, and the significant correlation between walking speed and RCOF was found. However, the correlation between RCOF and the other respective coefficients of slip resistance was almost unidentified thus it would be difficult to identify the actual property of floor slipperiness with the RCOF alone.

Characterization of Porous Asphalt Concrete Coated with MMA Resin (아크릴 수지로 코팅한 배수성 아스팔트 콘크리트의 특성 평가)

  • Choi, Tae-Jun;Lee, Hyun-Jong;Kim, Tae-Woo;Song, Jae-Hyok
    • International Journal of Highway Engineering
    • /
    • v.11 no.2
    • /
    • pp.111-120
    • /
    • 2009
  • This paper presents a fundamental findings of the functional and structural performance of the porous asphalt concrete coated with MMA resin. To evaluate the structural performance, cantabro, wheel tracking, moisture sensitivity and indirect tensile fatigue tests are performed. The tests results show that the cantabro loss is reduced three times and fatigue resistance is significantly increased after the specimens are coated with MMA resin. However there are little changes in the rutting and moisture damage resistances before and after the coating. Air voids, permeability and BPT(British Pendulum Test) tests are conducted to study the functional performance. It is observed form the tests that the air voids and permeability are slightly decreased after the coating. However, the changes in the air voids and permeability are negligible. The skid resistance of the coated specimens is lower than reference specimens. However, the skid resistance is maintained beyond the level of the reference specimens when silica sands are chipped on top of the coated surface.

  • PDF

A Study on Floor Slip Resistance Standard and Test Method for BF Certification (BF인증을 위한 바닥 마감재 미끄럼 성능기준 및 측정방법에 대한 연구)

  • Shin, Dong-Hong;Seong, Ki-Chang;Park, Kwang-Jae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.75-83
    • /
    • 2019
  • Purpose: There are no clear criteria for slip performance in the BF certification process, so the evaluator relies on subjective judgments depending on the field situation. Physical criteria for determining the slip performance of various floor finishes are not clear. C.S.R., the only criterion currently being used to check slip performance, may raise questions about its coverage, feasibility and reliability. Method: For an analysis of domestic standards and status, KS L 1001, KS M 3510, and KS F 2375. External standards are analyzed for ADA Standard, ANSI Standard, and BS EN Standard. Analyze the test methods and evaluation criteria of O-Y-PSM, BPT, and the dynamic slip resistance test used in these criteria. It also presents an improvement plan for the rational presentation of standards. Results: To date, various kinds of test methods and measuring devices of the slip resistance coefficient have been developed, but there are not many ways to trust useful results related to user safety. Reliability and thoroughly verified test methods and criteria should be used to assess the slip performance of the floor. In order to improve the standard for the evaluation of slip performance in Korea, the existing standard should first be raised to the same level as the overseas standard, and the application of the discriminatory standard should be applied considering the characteristics and usage patterns of each space. Implication: Currently, Korean standards propose various test methods, but the proper use of test methods, scope and assessment criteria are not established, so improvement of the comprehensive standard is necessary.

A Study on the Tribological Characteristics of Purity $Al_2O_3-ZrO_2$ Ceramics materials ($Al_2O_3-ZrO_2$ 세라믹 재료의 순도에 따른 트라이볼로지 특성 연구)

  • Oh, Seong-Mo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.11a
    • /
    • pp.76-79
    • /
    • 2006
  • 세라믹 재료에 대한 트라이볼로지 특성은 기계장치의 실 링, 펌프부품, 미터 계 부품 등에 이용할 때 매우 중요하다. 본 연구에서는 각기 순도가 다른 알루미나와 지르코니아를 기계적 및 트라이볼로지적 특성에 미치는 영향을 고찰 하였다. 실험은 미끄럼거리와 미끄럼 속도, 그리고 마모량과 마찰계수 등을 서로 다른 순도에 따라 측정한 결과 알루미나의 순도 99.7%가 마찰계수와 마모 저항성이 매우 좋은 특성을 얻었으나, 지르코니아의 순도 95%는 상대적으로 마모량이 가장 크게 나타났다.

  • PDF

Experimental Examination of Nonslip Technique of Floors (바닥의 미끄럼 방지기술에 관한 실험적 검토)

  • Shin, Yoon-Ho;Baek, Koen-Hyuk;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.235-238
    • /
    • 2009
  • The study of our investigating and analyzing through experiments the performance on nonslip techniques, which has been nationally applied and represented, showed the following results. 1) In wearing shoes condition, regardless the shape of the surface and surface condition of the object, it satisfied the performance standard in cleaned and dried condition and the pulverulent body mixed liquid dispersed moisture condition. However, for the case of the non-slip agent treatment, not likely as the non-slip tape treatment case, the effect was not approved as it shows almost the same CSR as none treatment. 2) In bare foot condition, it satisfied the performance standard in most of the objects except for the Ceramic tile (A), Ceramic tile (B), pure and soapy water dispersed condition.

  • PDF

Effect of sliding velocity on the wear and friction characteristics of a carbon fiber composites (탄소 섬유 복합재의 마찰 및 마모 특성에 미치는 속도 효과)

  • Koh, Sung-Wi;Yang, Byeong-Chun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.4
    • /
    • pp.337-343
    • /
    • 2004
  • This paper presents an experimental study of friction and wear properties of a unidirectional oriented continuous crbon-fiber reinforced epoxy composite at the ambient temperature. Friction and wear experiments were conducted in the three principal sliding direction of the fiber orientation in the composite were selected against the stainless steel counterpart specularly processed were using a pin -on-disc apparatus. Friction coefficient and specific wear rate at various normal loads and sliding velocities wear determined. When sliding took place against smooth and hard counterpart, the hightest were resistance and the lowest friction coefficient were observed in the anti-parallel direction. The wear track of the worn specimens was examined with a scanning electron microscope(SEM) to observe the damaged fibers on the surface. In addition, SEM observations of the worn surfaces allowed to identify the involved different wear mechanisms.

A Study on the Change of Slipperiness of Building Floor-coverings by Friction Wear (건축물 바닥재의 마모에 따른 미끄럼성능 변동에 관한 연구)

  • Shin, Yun-Ho;Choi, Soo-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.1 s.15
    • /
    • pp.53-61
    • /
    • 2005
  • The purpose of this study presents useful data on the choice or development of floor covering from slip viewpoint by examining closely the impact of the changes in sliding experiments due to the wear of floor covering by walk. The result of wear practical test per ten thousand walks enforces some kind of popular floor covering and measure of coefficient of slip resistance as follows: (1) When surface of floor covering is in the state of wet, the degree of wear doesn't affect greatly in slip. (2) When surface of floor covering is in dry and clean state, most floor coverings have the tendency to lower the coefficient of slip resistance with the amount of walk on it. (3) Change in the tendency of slip resistance by wear appeared mainly due to the differences in the state of floor covering and organic floor covering appeared to have great reduction of coefficient of slip resistance than the inorganic ones. (4) According to the result of investigation on changes in tendency of coefficient of slip resistance due to the increase in the number of walk and if two hundred thousand walks were done, regardless of surface shape or kind of site, etc, the safety of floor covering, in slip viewpoint, greatly reduces.

Relationship between RCOF Calculated from the Results of Gait Analysis and CSR Measured Using O-Y·PSM (O-Y·PSM에 의한 CSR과 보행분석에 의한 RCOF와의 관계)

  • Roh, Yong-Woon;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.59-61
    • /
    • 2013
  • The purpose of this study was to present the necessary data concerning the selection and development of floor-coverings in view of slipperiness by comparing the relationship between CSR measured with O-Y·PSM and RCOF calculated from the result of gait analysis. CSR was calculated from maximum tensile load(Pmax) divided by perpendicular load(785N) when pulled 18 degrees upward the moment the bottom of the slip piece contacted the surface of the test piece. RCOF was calculated based on Fy/Fz from when horizontal load reached the maximum point within the sections from the moment the front of outsole touched the test piece to when pulled off the test piece. The results from the research were as follows: (1) Range of CSR was 0.15-1.02, which meant the differences of slipperiness of the test pieces definitely showed up. (2) RCOF are inadequate to express the characteristic about the slipperiness of the floors, since there were no differences between the test pieces.

  • PDF

Evaluation Method of Slipperiness of Inclined Floors from a Viewpoint of Safety in Case of the Physically Handicapped Persons in Walking (신체장애자의 안전성 관점에서 경사로 바닥의 미끄럼 평가방법에 관한 기초적 연구)

  • Choi, Soo-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.5
    • /
    • pp.145-153
    • /
    • 2009
  • The purpose of this research is to compare and analyze the change that must be applied to the evaluation of the slipperiness of an inclined floor, when considering its use by the physically handicapped and by the able-bodied. For this study, a simulator that can reproduce the characteristics of the body sway of a physically handicapped person was developed through a comparative experiment between able-bodied people and people with hemiplegia. In addition, as cale for the evaluation of the slipperiness of flat floors and inclined floors was composed by the sensory test result targeting physically handicapped persons (able-bodied persons wore the body sway for the handicapped and ageing in the experiment) and the able-bodied. In terms of the evaluation of the slipperiness of an inclined floor, it was evaluated that it is safe when the C.S.R' (Coefficient of Slip Resistance) of a healthy person is over 0.30, while it was evaluated that it is dangerous when the C.S.R' of a physically handicapped person is over $0.45{\sim}0.50$. Concerning this difference, it is judged that the reason for this difference is that the walking mechanism differs between an able-bodied person and a physically handicapped person.