• Title/Summary/Keyword: 물 순환 장치

Search Result 109, Processing Time 0.027 seconds

Analysis of SEWB Activities on Appropriate Technology in Korea and in Developing Countries Including Cambodia (한국 및 개도국(캄보디아 등) 사례로 본 국경없는 과학기술자회의 적정기술 분야 사업 분석)

  • Lee, Sujung;Choi, Yoonjung;Park, Sanghee;Kim, Yongsoo;Jeong, Seongpil
    • Journal of Appropriate Technology
    • /
    • v.7 no.1
    • /
    • pp.93-101
    • /
    • 2021
  • Scientists and engineers without borders (SEWB) was established on 2009 as the NGO having specialist groups to support the underprivileged in developing countries living in the isolated area and having water and sanitation problems. After the SDGs were suggested by the UN on 2016, activities are globally conducted by the nation, NGO and etc. to improve health and education of the underprivileged in developing countries. SEWB also have been conducted the projects in Korea and developing countries to reduce the gap of the infrastructure between the developed and developing countries and to help sustainable development in the developing countries by providing appropriate technology. In Korea, SEWB have been held international conference on appropriate technology (ICAT), lectures, and competitions for specialists and students. In developing countries including Cambodia and other 5 countries, SEWB have been provided water packages funded by iCOOP KOREA and volunteer opportunities. Since 2019, 'SEWB sustainable village development project' have been conducted in Bot Veng village, Cambodia to improve infrastructures on water, electricity, transportation, and agriculture by using desalination system, Solar Cow system, strengthened wooden bridge, and poultry farm, respectively. The developed solution for developing countries from SEWB could contribute to eliminate the water shortage and poverty.

The Study of Operating Conditions by Establishing Density Currents Generator for Improving of Water Quality on Lake Water - With Focus on DO and Water Temperature - (호소수의 수질개선을 위한 DCG 설치시 운전조건에 관한 연구 - DO와 수온을 중심으로 -)

  • Lee, Young-Shin;Han, Kyung-Hee;Kim, Young-Kyu;An, Hyung-Chul;Shin, Sung-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.286-294
    • /
    • 2014
  • The purpose of this study is to investigate the effects of applying density current generator (hereafter referred to as DCG to large lakes on the operating conditions of DCG, de-stratification, water quality improvement and inhibition of algae occurrence. As a result of a survey conducted to derive the optimum operating parameters of DCG in a condition to minimize eco-toxicity, the following conclusions were obtained. During the survey period, a marked stratification appeared in September to October 2011 and May 2012. At this time, the average depth of water to form thermocline was found to be $5{\pm}2$ m, so the location of discharge port for the operation of DCG was determined to be about 5 m below from the surface. To minimize the adverse effects of benthos and obtain the effect of water mixture at the time of water circulation, the mixing ratio of surface water and deep water was designed to be 3:1 by means of ecotoxicological assessment on the DCG operating characteristics. To select the appropriate operating hours for DCG, DCG was operated by 12 hr, 24 hr, 36 hr and 48 hr. As its result, the formation of thermocline did not occur during the operation of 36 hr. Also, It was effected that start reoperating from 3rd day after stop 2days under the condition of operated during 36 hr with calculated power consumption. Under the above conditions, the results of DO and water temperature analysis during the operation of DCG showed that the stratification, which was distinct previously, appeared to be weak, and relatively lower levels than those before operation were found as a result of water quality analysis on COD and chlorophyll-a, which leads to the conclusion that the water body is maintained at a stable condition due to the circulation of water by the occurrence of density current resulting from the operation of DCG.

Effect of Aotomatic Scale Removal System for Piping in Refrigeration & Air Conditioning System (냉동·공조기 배관내 스케일 자동제거장치의 효과)

  • Kim, Jong-Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.908-914
    • /
    • 2017
  • In this study, we developed a system that automatically removes the scale in the piping by using electrolysis principle in order to solve the cooling performance of the refrigeration and air conditioning system by acting as heat resistance in the heat transfer process by forming the scale in the heat exchanger for refrigeration air conditioning. We want to check the performance through experiments. Therefore, by circulating the treated water using the principle of electrolysis without stopping the system, Ca, Mg and $SiO_2$ are precipitated in the form of solids and discharged to the outside of the pipe system, thereby preventing scale formation in the pipe and removing the scale. Thereby maintaining the heat transfer performance of the pipe. As a result of the experiment, the heat transfer rate of the scaled pipe was 86.66% when the heat transfer rate of the new pipe was 100, and the heat transfer rate was recovered to 90.5% when the scaled pipe was operated for 1 month. The heat transfer rate recovered to 97.86% when driving for two months and to 98.72% for three months. It was confirmed that the scaling effect of the scale formed in the piping was understood in a relatively short experiment period, and the heat transfer performance was also influenced.

A study on the electrochemical reduction of carbon dioxide (전기화학환원에 의한 이산화탄소의 수소화 반응연구)

  • Sim, Kyu-Sung;Kim, Jong-Won;Kim, Yeon-Soon;Myeong, Kwang-Sik
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.9 no.1
    • /
    • pp.8-15
    • /
    • 1998
  • The catalytic hydrogenation of carbon dioxide has been studied for the fixation of carbon dioxide to mitigate global warming problems, but it needed hydrogen, which the price is still high. Recently, the electrochemical reduction of carbon dioxide has been drawn attractions because carbon dioxide could be converted to the valuable chemicals such as methane, ethane and alcohols electrochemically in the electrolyte solution using a catalytic electrode. This system is simple because the water electrolysis and hydrogenation take place at the same time using the surplus electricity at midnight. In this work, a continuous electrochemical reduction system was fabricated, which was composed of the reduction electrode (copper or perovskite type, $2{\times}2cm^2$), reference electrode(platinum, $2{\times}6cm^2$), standard electrode(Ag/AgCl), and potassium bicarbonate electrolyte solution saturated with carbon dioxide. The quality and quantity of the products and reduction current were analyzed, according to the electrolyte concentration and electrode type.

  • PDF

Inhibitory Effects of Extracts from Albizzia julibrissin on Gonadal Maturation in a Medaka (Oryzias latipes) (자귀나무 추출물이 송사리(Oryzias latipes) 생식소 성숙에 대한 억제효과)

  • Lee, Eun-Hee;Oh, Sang-Pil;Kim, Myong-Hee;Kim, Kwang-Hyun;Hong, Sang-Hoon;Han, Chang-Hee
    • Journal of Life Science
    • /
    • v.23 no.3
    • /
    • pp.333-340
    • /
    • 2013
  • This study was performed to determine whether stem bark extract containing saponin of Albizzia julibrissin in the diet influences gonadal maturation and spawning in medaka (Oryzias latipes). The crude extraction containing saponin (HaBC) was partially purified from n-BuOH extraction of A. julibrissin stem bark by Diaion HP-20, Silica gel and Sephadex LH-20 chromatographies. We fed diets supplemented with HaBC to medaka. We then studied the effects of the HaBC supplement on the suppression of gonadal maturation and spawning in female medaka that were reared in aquaria with recirculation systems. In the experiment with immature female medaka, the periods of initiation of gonadal maturation and spawning were delayed in the fish that were fed diets supplemented with at least HaBC 20 mg/g-feed. In the experiment with mature female medaka, the fish that were fed diets supplemented with at least HaBC 20 mg/g-feed had lower GSIs than the control diet group did. The results showed that the growth of the immature medaka was not correlated with the amount of supplementation of HaBC in the diet. However, the condition factors (CF) in the medaka that were fed diets supplemented with at least HaBC 20 mg/g-feed were higher than in the medaka fed on the control diet. We concluded that extracts containing saponin from the stem bark of A. julibrissin have the potential to inhibit gonadal maturation in female medaka, but they did not act as growth stimulation. Further studies are required to determine the mechanism of the action.

CO2 Decomposition Characteristics of Zn-ferrite Powder Prepared by Hydrothermal and Solid State Reaction (수열합성법과 고상법을 이용해 제조된 Zn-ferrite 분말의 이산화탄소 분해 특성)

  • Nam, Sung Chan;Park, Sung Youl;Yoon, Yeo Il;Jeong, Soon Kwan
    • Applied Chemistry for Engineering
    • /
    • v.22 no.5
    • /
    • pp.555-561
    • /
    • 2011
  • The objective of this study is the development of carbon recycle technology which converts $CO_2$ captured from flue gas to CO or carbon and reuse in industrial fields. Since $CO_2$ is very stable and difficult to decompose, metal oxide was used as an activation agent for the decomposition of $CO_2$ at low temperature. Metal oxides which convert $CO_2$ to CO or carbon at $500^{\circ}C$ were prepared using Zn-ferrite by the solid state reaction and hydrothermal synthesis. The behaviors of $CO_2$ decomposition were studied using temperature programmed reduction/oxidation (TPR/TPO) and thermogravimetric analyzer (TGA). Zn-ferrite containing 5 wt% ZnO showed the largest reduction and oxidation. Reduction by $H_2$ was 26.53 wt%, oxidation by $CO_2$ was 25.73 wt% and 96.98% of adsorbed $CO_2$ was decomposed to $CO_2$ and carbon with excellent oxidation-reduction behaviors.

Characteristics of Phytoplankton Succession Based on the Functional Group in the Enclosed Culture System (대형 배양장치에서 기능그룹에 기초한 식물플랑크톤 천이 특성)

  • Lee, Kyung-Lak;Noh, Seongyu;Lee, Jaeyoon;Yoon, Sungae;Lee, Jaehak;Shin, Yuna;Lee, Su-Woong;Rhew, Doughee;Lee, Jaekwan
    • Korean Journal of Ecology and Environment
    • /
    • v.50 no.4
    • /
    • pp.441-451
    • /
    • 2017
  • The present study was conducted from August to December 2016 in a cylindrical water tank with a diameter of 1 m, a height of 4 m and a capacity of 3,000 L. The field water and sediment from the Nakdong River were also sampled for the experimental culture (field water+sediment) and control culture (field water), respectively. In this study, we aimed to investigate phytoplankton succession pattern using the phytoplankton functional group in the enclosed culture system. A total of 50 species in 27 genera including Chlorophyceae (30 species), Bacillariophyceae (11 species), Cyanophyceae (7 species), and Cryptophyceae (2 species) were identified in the experimental and control culture systems. A total of 19 phytoplankton functional groups (PFGs) were identified, and these groups include B, C, D, F, G, H1, J, K, Lo, M, MP, N, P, S1, $T_B$, $W_0$, X1, X2 and Y. In particular, $W_0$, J and M groups exhibited the marked succession in the experimental culture system with higher biovolumes compared to those of the control culture system, which may be related to the internal cycling of nutrients by sediment in the experimental culture system. The principal component analyses demonstrated that succession patterns in PFG were associated with the main environmental factors such as nutrients(N, P), water temperature and light intensity in two culture systems. In conclusion, the present study showed the potential applicability of the functional group for understanding the adaptation strategies and ecological traits of the phytoplankton succession in the water bodies of Korea.

The Effects of Scale Growth Inhibition on Water Pipe using Frequency Driver (Frequency Driver를 이용한 냉온수관의 스케일 방지억제효과)

  • Jang, Mi-Jeong;Sung, Il-Wha
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.258-266
    • /
    • 2011
  • Scale induced by hardness materials in water must be controled because of it can be result in remarkable damages of pipeline as well as water quality deterioration. Especially hot water system is one of scale management required facility as scale formation can be accelerated by temperature. The scale control performance of frequency driver (FD) was tested instead of existing methods such as chemical, physical and electromagnetic methods which needs chemicals and electric power. Three kinds of pipe coupons were submerged in test water with 500 mg/L of hardness for 33 days and XRD and SEM were analysed for comparing scale formation characteristics of these coupons. Calcite ($CaCO_3$) which came from hardness of water was formed on only cast iron pipe coupon and this coupon showed higher corrosion rate than copper and stainless steel pipe coupon. Hot water circulating system connected cast iron pipe with and without FD was operated with 300 mg/L of hardness water at $50^{\circ}C$ for monitoring of scale formation and water quality with and without FD. XRD showed that FD leaded to magnetite ($Fe_3O_4$) scale which is good scale for preventing corrosion than calcite and SEM image also indicated the scale control effect of FD. Scales of 16% on pipe joint, 14% on pipe length, and 42% on heat exchanger decreased with FD comparing scales of those parts without FD. From the results of water quality, FD reduced crystallization of hardness material without chemical reaction in water and it can indicate that FD is safe and proenvironmental technology for scale reduction.

Removal of calcium chloride in road structure using ultra-fine bubble washing machine (미세기포 세척장비를 이용한 도로시설물 염화칼슘의 제거)

  • Park, Gun-Il;Lee, June-Hyung;Park, Hyung-Jun;Kim, Hyun-Jin;Kim, Heung-Rae;Cho, Il Hyoung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.1281-1289
    • /
    • 2019
  • This study was conducted to evaluate the optimal operating condition of ultra-fine bubble washing machine for removing calcium chloride from road concrete structure. The diameter of the ultra-fine bubble was measured to 196.6 ± 100.6 nm and the ultra-fine bubble concentration was measured to 1.36 × 108 cell/ml. As a result of the performance on the spray device of the washing machine, it was confirmed that the washing efficiency of 93% and 91% appeared at 100cm and 150cm of injection distance at 100bar injection pressure. By increasing the ultra-fine bubble generation cycles from 2 to 6, the chloride removal rate increased from 1% to 7%. As the ultra-fine bubble generation air flow was lowered from 4 ml/min to 0.5 ml/min, it was confirmed that the washing efficiency increased up to 30%. The washing efficiency of ultra-fine bubble water was 25% higher than normal water.

Evaluation of Destratification Efficiency by Combined Effect of Adjacent Plumes through 2-Phase and 3D Hydrodynamic Analysis in a Stratified Fluid (Bubble plume의 중첩효과가 저수지 성층파괴 효율에 미치는 영향에 대한 수리동역학적 2상-3차원 평가)

  • Yum, Kyung-Taek;Park, Hee-Kyung;Ahn, Je-Young
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.3
    • /
    • pp.219-231
    • /
    • 2004
  • The use of air diffuser system to ameliorate the reservoir by breaking stratification is now widespread. This study focuses on the hydrodynamic behavior of bubble plumes, which is the major mechanism of destratification and their combined effect of adjacent plumes on destratification efficiency. By introducing 2-phase Computational Fluid Dynamics(CFD) technique, we could suggest the optimal diffuser spacing having optimal destratification efficiency by simply analyzing the complex destratification procedures varying with the seasonal stratification intensity and bubble flow rate. Lab experiments were also carried out to verify CFD model in thermally stratified fresh water which quite differs from former researches using salts. This study showed that the mixing efficiency strongly depends on the spacing of neighboring plumes. When diffuser spacing is lower than 1.5 times the depth, the combined effect is stronger; as Plume Number(PN) is increased, the efficiency is strongly affected by spacing. If the distance is shorter than the depth of water, the efficiency increases linearly in proportion to PN. Otherwise, the efficiency increases non-linearly. These findings suggest that the combined effect should be more quantitatively taken into consideration for design and operation of air-diffuser destratification system, and recommend that the optimal destratification efficiency will be when plume number is 1000 and the spacing between neighboring diffusers is 1.5 times the depth.