• Title/Summary/Keyword: 물통로

Search Result 30, Processing Time 0.056 seconds

A Study on Dosimetry for Small Fields of Photon Beam (광자선 소조사면의 선량 측정에 관한 연구)

  • 강위생;하성환;박찬일
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.57-68
    • /
    • 1994
  • Purpose : The purposes are to discuss the reason to measure dose distributions of circular small fields for stereotactic radiosurgery based on medical linear accelerator, finding of beam axis, and considering points on dosimetry using home-made small water phantom, and to report dosimetric results of 10MV X-ray of Clinac-18, like as TMR, OAR and field size factor required for treatment planning. Method and material : Dose-response linearity and dose-rate dependence of a p-type silicon (Si) diode, of which size and sensitivity are proper for small field dosimetry, are determined by means of measurement. Two water tanks being same in shape and size, with internal dimension, 30${\times}$30${\times}$30cm$^3$ were home-made with acrylic plates and connected by a hose. One of them a used as a water phantom and the other as a device to control depth of the Si detector in the phantom. Two orthogonal dose profiles at a specified depth were used to determine beam axis. TMR's of 4 circular cones, 10, 20, 30 and 40mm at 100cm SAD were measured, and OAR's of them were measured at 4 depths, d$\sub$max/, 6, 10, 15cm at 100cm SCD. Field size factor (FSF) defined by the ratio of D$\sub$max/ of a given cone at SAD to MU were also measured. Result : The dose-response linearity of the Si detector was almost perfect. Its sensitivity decreased with increasing dose rate but stable for high dose rate like as 100MU/min and higher even though dose out of field could be a little bit overestimated because of low dose rate. Method determining beam axis by two orthogonal profiles was simple and gave 0.05mm accuracy. Adjustment of depth of the detector in a water phantom by insertion and remove of some acryl pates under an auxiliary water tank was also simple and accurate. TMR, OAR and FSF measured by Si detector were sufficiently accurate for application to treatment planning of linac-based stereotactic radiosurgery. OAR in field was nearly independent of depth. Conclusion : The Si detector was appropriate for dosimetry of small circular fields for linac-based stereotactic radiosurgery. The beam axis could be determined by two orthogonal dose profiles. The adjustment of depth of the detector in water was possible by addition or removal of some acryl plates under the auxiliary water tank and simple. TMR, OAR and FSF were accurate enough to apply to stereotactic radiosurgery planning. OAR data at one depth are sufficient for radiosurgery planning.

  • PDF

Analysis of Working Capacity of a Hand-fed Transplanter (반자동정식기 작업 성능 분석)

  • 문성동;민영봉;박중춘
    • Journal of Bio-Environment Control
    • /
    • v.6 no.3
    • /
    • pp.159-167
    • /
    • 1997
  • To cope with the mass-production and supply of plug seedling, the supply of transplanters is necessary. In the study, a transplanting test was carried out to find the optimum working condition in the mechanizd transplantation and to acquire the basic data for the improvement of transplanters by the research and analysis of working capacity of the local manual transplanters. The size of hopper affected transplanting stand and rate. Re-irrigation was required for the transplanted seedlings because they wilt 1 day after the transplanting if soil compaction is incomplete. Consequently, back-forth-left-right compaction method was good for soil covering and compaction. It may be thought to increase the amount of irrigation water at the time of transplanting by double-irrigation mechanism, but it needs to increase the larger water tank which makes the operation uneasy. So, assuming the working model by 1 or 2 operators with the machine size as small as possible, it seemed that eliminating of automatic irrigation method was desirable in view of efficiency. Though semiautomatic transplanter needs some structural improvements, it seemed still suitable for transplanting of plug seedlings such as 45-day red pepper seedlings in 128-hole tray and 25-day Chinese cabbage seedling in 128-hole tray. If traveling speed of the transplanter is limited to less than 14 m/min, with the transplanting depth of 2~3cm and transplanting space of 30cm.

  • PDF

Developing an improved water discharge anchor & trap bolt to prevent basic salt penetration to harbor structures (해수 염기 침투방지를 위한 성능개선 형 물배출 앵커 및 트랩볼트 개발에 관한 연구)

  • Ock, Jong-Ho;Moon, Sang-Deok;Lee, Hwa-Sun;Shin, Kyung-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.674-682
    • /
    • 2018
  • Large industrial motors require a large area because of the high risk of shutdown accidents and large industrial accidents due to the lowering of the dielectric strength of the armature windings and overheating problems. Therefore, there is a demand for a large-capacity motor that has small size, light weight, and excellent dielectric strength compared with conventional motors. Superconducting motors have advantages of high efficiency and output power, low size, low weight, and improved stability. This results from greatly increasing the magnetic field generation by using superconductive field coils in rotating machines such as generators and motors. It is very important to design and analyze the cooling system to lower the critical temperature of the wires to achieve superconducting performance. In this study, a field loss analysis and low-temperature heat transfer analysis of the cooling system were performed through the conceptual design of a 100-HP high-temperature superconducting synchronous motor. The field loss analysis shows that a uniform pore magnetic flux density appears when high-temperature superconducting wire is used. The low-temperature heat transfer analysis for gaseous neon and liquid neon showed that a flow rate of 1 kg/min of liquid neon is suitable for maintaining low-temperature stability of the high-temperature superconducting wire.

Agricultural Radial Collector Wells in South Korea and Sustainability (한국의 농업용 방사상 집수정 현황 및 지속가능성)

  • Hong, Soun-Ouk;Song, Sung-Ho;An, Jung-Gi;Kim, Jin-Sung
    • The Journal of Engineering Geology
    • /
    • v.26 no.3
    • /
    • pp.331-337
    • /
    • 2016
  • Radial collector wells (RCWs) have been managed by Korea Rural Community Corporation (KRC) since 1983, installing 98 wells for agriculture in rural area over the country. Among them, 20 wells were installed upstream of 5 subsurface dams and the remaining were installed regardless of the subsurface dam. Most of RCWs have been developed in 1980s and 1990s, and 83 wells have been passed more than 20 years after construction. The number of horizontal arms for RCWs varies from 9 to 28, with length and diameter being 10~30 m and 65 mm, respectively. The central caisson with an inner diameter of 3.5 m was commonly constructed to a depth of 10 m. The maximum pumping rates in RCWs, which are located at distances of 10 to 1,200 m from the river, are 2,000~10,000 m3/day. RCW has a fundamental problem that reduced pumping capacity and degraded well efficiency, due to the physical and chemical clogging. From the feasibility test for improving RCW performance, specific capacity increased to 67% after rehabilitation. TV logging for RCW horizontal arm shows that near the caisson is more severe clogging. From the results of this study, KRC has established the guidebook for monitoring and improving well efficiency through physical/chemical treatment, well logging, and hydraulic tests and managed RCWs periodically with its rehabilitation methods.

Floristic Study of Mt. Deoktaesan, Jinan, Jeonbuk (덕태산(전북 진안)의 관속식물상)

  • Na, Nu-Ree;Kim, Yoon-Young;Lee, Ga-ram;Song, Hye-In;Park, Jeong-Mi;Jang, Changgee
    • Korean Journal of Plant Resources
    • /
    • v.30 no.4
    • /
    • pp.378-398
    • /
    • 2017
  • Mt. Deoktaesan(1,113 m) is located in Jinan-gun Baekun-myon and Jangsu-gun Chunchun-myon. Investigated area was decided to include Mt. Deoktaesan, Mt. Seongaksan and its neighbor area, and this study was conducted from March to October, 2015 in 12 days. Based on the voucher, vascular plants in Mt. Deoktaesan were 108 families 341 genera 525 species 4 subspecies 64 varieties 14 forms, totally 607 taxa, which is 12.4% of total Korean flora. Korean endemic plants were 15 species. Among these species, Populus tomentiglandulosa T.B.Lee, Campanula takesimana Nakai and Forsythia koreana (Rehder) Nakai are verified as planted species. Rare and endangered plants of designated by Korea Forest Service were 10 taxa, such as Peucedanum hakuunense Nakai, Paeonia japonica (Makino) Miyabe & Takeda, Koelreuteria paniculata Laxmann, Eranthis stellata Maxim., Eranthis stellata Maxim., Viola albida Palib., Chionanthus retusus Lindl. & Paxton, Campanula takesimana Nakai, Tricyrtis macropoda Miq. and Iris ensata var. spontanea (Makino) Nakai, respectively. Phytogeographical special plants were totally 41 taxa, which were grade 17 taxa of garde I, 12 taxa of grade II, 12 taxa of grade III, 8 taxa of grade IV, and 1 taxon of grade V.

A Survey on Hanwoo Calf Management Prior to Weaning (이유전 합리적인 송아지 사양관리를 위한 한우농가 송아지 사양관리 실태 조사)

  • Yeo, Joon-Mo;Lee, Sung-Hoon;Ki, Kwang-Seok;Hwang, Jin-Ho;Lee, Sung-Sill;Kim, Wan-Young
    • Journal of Animal Science and Technology
    • /
    • v.54 no.2
    • /
    • pp.141-147
    • /
    • 2012
  • The present survey was conducted to provide basic information on Hanwoo calf management. Eight hundred and sixty-two Hanwoo breeding farms from all nine provinces were surveyed via personal interviews. The percentages of farms categorized by herd size were 30.5%, 32.8%, 26.0% and 10.7% for <50 heads, 51-100 heads, 101-200 heads, and >200 heads, respectively. More than 50% of farms offered calf starter at 6-10 days of age, showing that calf starter was offered relatively at an earlier age. Calf starter was replaced every three days by 30.1% of farms. The percentages of farms replacing starter weekly (19.2%) were even higher than those of replacing starter daily (18.8%), suggesting that the frequency of replacing starter needs to be increased to maintain starter freshness and to increase starter intake. About one-third of farms offered forage at 6-10 days of age and 21% of farms offered even at 1-5 days of age although it has been well known that forage does not contain either nutrient density or nutrient profile necessary to stimulate rumen papillae development, especially before weaning. Furthermore, about half of farms used rice straw with calf starter. Water was offered relatively at an earlier age (1-5 days of age) by 55% of farms. Deciding when to wean calves should be based on starter intake rather than age but less than 50% of farms decided weaning age by starter intake. In conclusions, to reduce weaning age of Hanwoo calves by rapid rumen papillae development it is necessary to provide fresh starter and water by increasing frequency of starter replacing and water trough cleaning and not to feed forage before weaning.

Growth of Soybean Sprouts and Concentration of $CO_2$ Produced in Culture Vessel Affected by Watering Methods (살수방식에 따른 재배용기내 Gas 조성 및 콩나물의 생육 변화)

  • 배경근;남승우;김경남;황영현
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.49 no.3
    • /
    • pp.167-171
    • /
    • 2004
  • The growth of soybean sprout was greatly influenced by watering systems: Fixed watering system (water tub was loaded at ceiling upper of culture box and water was showered by bottom holes) was estimated the better than that of reciprocating watering and tub immersing watering because it could cool down the temperature in culture box and wash the organic substances on the body of sprout. The fixed watering system showed good body color and preventing effect of partial rotting of sprout because it could discharge $\textrm{CO}_2$ gas effectively in culture box and keep the concentration below 5%. The concentration of gases at the bottom (about 30 cm height from basal plate) of culture box in fourth or fifth days was L6% for $\textrm{CO}_2$ and 13-16% for $\textrm{O}_2$, respectively. The optimum gas concentration in culture box was considered to be over 10% for $\textrm{O}_2$ and below 5% for $\textrm{CO}_2$.

Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm (Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구)

  • Tan, Kee Chin;Kim, Tae-Hyung;Chun, Song-I;Han, Yong-Hee;Choi, Ki-Seung;Lee, Kwang-Sig;Jun, Jae-Ryang;Eun, Choong-Ki;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.131-141
    • /
    • 2008
  • Purpose : To investigate the feasibility and accuracy of Proton Resonance Frequency (PRF) shift based magnetic resonance (MR) temperature mapping utilizing the self-developed center array-sequencing phase unwrapping (PU) method for non-invasive temperature monitoring. Materials and Methods : The computer simulation was done on the PU algorithm for performance evaluation before further application to MR thermometry. The MR experiments were conducted in two approaches namely PU experiment, and temperature mapping experiment based on the PU technique with all the image postprocessing implemented in MATLAB. A 1.5T MR scanner employing a knee coil with $T2^*$ GRE (Gradient Recalled Echo) pulse sequence were used throughout the experiments. Various subjects such as water phantom, orange, and agarose gel phantom were used for the assessment of the self-developed PU algorithm. The MR temperature mapping experiment was initially attempted on the agarose gel phantom only with the application of a custom-made thermoregulating water pump as the heating source. Heat was generated to the phantom via hot water circulation whilst temperature variation was observed with T-type thermocouple. The PU program was implemented on the reconstructed wrapped phase images prior to map the temperature distribution of subjects. As the temperature change is directly proportional to the phase difference map, the absolute temperature could be estimated from the summation of the computed temperature difference with the measured ambient temperature of subjects. Results : The PU technique successfully recovered and removed the phase wrapping artifacts on MR phase images with various subjects by producing a smooth and continuous phase map thus producing a more reliable temperature map. Conclusion : This work presented a rapid, and robust self-developed center array-sequencing PU algorithm feasible for the application of MR temperature mapping according to the PRF phase shift property.

  • PDF

Dose Distribution and Image Quality in the Gantry Aperture for CT Examinations (전산화단층촬영 검사 시 Gantry Aperture 내의 선량분포와 영상의 질)

  • Cho, Pyong-Kon;Kim, You-Hyun;Choi, Jong-Hak;Lee, Ki-Yeol;Kim, Hyung-Cheol;Kim, Jang-Seob;Shin, Dong-Chul;Lee, Sung-Hyun;Lee, Jun-Hyub;Shin, Gwi-Soon
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.453-460
    • /
    • 2009
  • The purpose of this study was to determine the dose distribution and image quality according to slice thickness and BC(beam collimation) in the gantry aperture. CT scans were performed with a 64-slice MDCT(Brilliance 64, Philips, Cleveland, USA) scanner. To determine the dose distribution according to BC, a ionization chamber was placed at isocenter and 5, 10, 15, 20, 25 and 30 cm positions from the isocenter in the 12, 3, 6 and 9 o'clock directions. The dose distribution for phantom scan was also measured using CT head and body dose phantom with five holes at the center of the phantom and the positions of the 12, 3, 6 and 9 o'clock directions. The image noise measurement for different BCs was performed using an AAPM CT phantom. Water-filled block of the phantom was moved by 5 cm or 10 cm to the 12 o'clock direction, and the image noise was measured at the center of the phantom, and the points of 12, 3, 6 and 9 o'clock direction respectively. Some points were placed beyond the scan field of view (SFOV), so that measurement was not possible at that points. The results are as follows: The CTDIw showed a larger decrease as the source goes farther from the iso-center or the BC became wider. The CTDIw depends on the BC width more than the number of the channel of a detector array. The value of CTDIW decreased with increasing BC, but the value decreased 16.6~31.9% in the head phantom scan in air scan and 51.0~64.5% in the body phantom scan. The value of the noise was 3.9~5.9 in the head and 5.3~7.4 in the body except for BC of $2{\times}0.5\;mm$, regardless of the degree of deviation from the iso-center. When a subject was located within the SFOV, the position did not significantly affect image quality even if the subject was out of the center.

  • PDF

Pilot-scale Applications of a Well-type Reactive Barrier using Autotrophic Sulfur-oxidizers for Nitrate Removal (독립영양 황탈질 미생물을 이용한 관정형 반응벽체의 현장적용성 연구)

  • Lee, Byung-Sun;Um, Jae-Yeon;Lee, Kyu-Yeon;Moon, Hee-Sun;Kim, Yang-Bin;Woo, Nam-C.;Lee, Jong-Min;Nam, Kyoung-Phile
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.3
    • /
    • pp.40-46
    • /
    • 2009
  • The applicability of a well-type autotrophic sulfur-oxidizing reactive barrier (L $\times$ W $\times$ D = $3m\;{\times}\;4\;m\;{\times}\;2\;m$) as a long-term treatment option for nitrate removal in groundwater was evaluated. Pilot-scale (L $\times$ W $\times$ D = $8m\;{\times}\;4\;m\;{\times}\;2\;m$) flow-tank experiments were conducted to examine remedial efficacy of the well-type reactive barrier. A total of 80 kg sulfur granules as an electron donor and Thiobacillus denitrificans as an active bacterial species were prepared. Thiobacillus denitrificans was successfully colonized on the surface of the sulfur granules and the microflora transformed nitrate with removal efficiency of ~12% (0.07 mM) for 11 days, ~24% (1.3 mM) for 18 days, ~45% (2.4 mM) for 32 days, and ~52% (2.8 mM) for 60 days. Sulfur granules attached to Thiobacillus denitrificans were used to construct the well-type reactive barrier comprising three discrete barriers installed at 1-m interval downstream. Average initial nitrate concentrations were 181 mg/L for the first 28 days and 281 mg/L for the next 14 days. For the 181 mg/L (2.9 mM) plume, nitrate concentrations decreased by ~2% (0.06 mM), ~9% (0.27 mM), and ~15% (0.44 mM) after $1^{st}$, $2^{nd}$, and $3^{rd}$ barriers, respectively. For the 281 mg/L (4.5 mM) plume, nitrate concentrations decreased by ~1% (0.02 mM), ~6% (0.27 mM), and ~8% (0.37 mM) after $1^{st}$, $2^{nd}$, and $3^{rd}$ barriers, respectively. Nitrate plume was flowed through the flow-tank for 49 days by supplying $1.24\;m^3/d$ of nitrate solution. During nitrate treatment, flow velocity (0.44 m/d), pH (6.7 to 8.3), and DO (0.9~2.8 mg/L) showed little variations. Incomplete destruction of nitrate plume was attributed to the lack of retention time, rarely transverse dispersion, and inhibiting the activity of denitrification enzymes caused by relatively high DO concentrations. For field applications, it should be considered increments of retention time, modification of well placements, and intrinsic DO concentration.