• Title/Summary/Keyword: 물질전달 해석

Search Result 213, Processing Time 0.023 seconds

A Numerical Study of Heat and Mass Transfer Phenomena for Thermal Protection Material (열보호재료의 열 및 물질전달 현상에 관한 수치해석적 연구)

  • Kim, Jung-Hoon;Kwon, Chang-Oh;Seo, Jeong-Il;Bai, Cheol-Ho;Song, Dong-Joo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.9
    • /
    • pp.1201-1212
    • /
    • 1999
  • A numerical analysis is performed to predict the thermal response and ablation rate for charring or non-charring material which is designed to be used as thermal protection system (TPS). The numerical program composed of in-depth energy balance equation and the aerotherm chemical equilibrium (ACE) program. The ACE program calculates various thermochemical state from ablation products. The developed numerical program is verified by comparing the reported results from literature. The sensitivity tests for input parameters are performed. The thermal behavior of ablating material is mainly affected by density of ablating material, convective heat transfer coefficient and recovery enthalpy of flow field.

Heat and mass transfer characteristics of generator combined rectification system of the GAX ammonia absorption heat pump (GAX 암모니아 흡수식 열폄프의 발생기 일체형 정류기의 열 및 물질전달 해석)

  • 윤상국
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.431-439
    • /
    • 1999
  • A generator-GAX combined rectification system of an ammonia absorption heat pump was investigated to get the optimum design values. The mass and heat transfer phenomena of the rectification system were analysed. The number of column plates, equilibrium temperature of solution on each plate and flow rates of solution and vapor generated were predicted. The characteristics of mass and heat transfer of the generator-GAX combined rectification system, i.e. concentration difference of leaving solution and vapor on each column plate, were found to be mainly governed by the pressure of generator, reflex ratio and temperature difference of analyser coolant. The number of rectification column plates for each different pressure in generator was obtained. The optimum locations for installing the feeder from solution-cooled absorber and GAX desorber in generator were predicted. The improvement of COP was followed by the increase of the rectifier efficiency and the number of column plate, and the decrease of reflex ratio.

  • PDF

A Numerical Analysis of cleat and Mass Transfer on the Dehumidifier of Liquid Desiccant Cooling System (액체 건조제 냉각장치의 제습기에서 열 및 물질전달 수치해석)

  • Go, Gwang-Ho;O, Myeong-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1756-1765
    • /
    • 2001
  • The heat and mass transfer process between the falling liquid desiccant(TEG) film and the air in counter flow at the dehumidifier of desiccant cooling system were investigated. The governing equations with appropriate boundary and interfacial conditions describing the physical problems were solved by numerical analysis. As a result, the effects of the design parameters and the outside air conditions on the rates of dehumidification and sensible cooling were discussed. The results of the dehumidification and sensible cooling rates were compared with those of the cross flow at the same conditions.

Semi-Empirical Analysis of the Mass Transfer Characteristics of the Slug Flow in Vertical Mesoscale Tubes (작은 수직관을 흐르는 슬러그 유동의 물질전달 특성에 대한 반경험적 해석)

  • Kim, Dong-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.8
    • /
    • pp.366-374
    • /
    • 2014
  • Experimental mass transfer data, which were obtained for the $CO_2$-water slug flows in vertical tubes with 2, 5, and 8mm diameters, were analyzed in comparison with the penetration theory. It was found that a penetration model with molecular diffusion coefficient cannot predict the experimental data accurately. An effective diffusion coefficient, which considers enhancement effect of interfacial waves, was suggested to improve prediction. Another empirical factor was also suggested to consider the effect of non-uniform interface velocity. A modified penetration model was found to be capable of predicting the experimental data reasonably well.

An Experimental Study on Frosting of Humid Air-flow on a Surface with Local Cooling for Heat Exchanger Design (열교환기 설계를 위한 국소 냉각 표면위에서의 습공기 유동의 착상실험)

  • Kwon, Jeong-Tae;Lim, Hyo-Jae;Park, Kyoung-Woo;Kim, Chang-Eob;Kim, Kyung-Min;Kwon, Young-Chul
    • Journal of Energy Engineering
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2008
  • The present study has been conducted to understand the heat and mass transfer characteristics of humid airflow in frosting conditions. A flat plate of aluminum was used for the simulation of flat surface part of the fin of the heat exchanger. The aluminum surface temperatures were measured and analyzed to clarify the heat and mass transfer characteristics under frosting conditions. Also, the pressure drops were measured to clarify the air-blocking effect of frost in the mini channel of the air-side hoot exchangers. A data reduction method was developed far the analysis of local characteristics of humid air under frosting conditions.

Finite Element Analysis of Heat and Moisture Transfer in Porous Materials (다공성 물질의 열 및 습도 전달에 관한 유한요소 해석)

  • Lee, Ho-Rim;Geum, Yeong-Tak;Song, Chang-Seop;O, Geun-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.7
    • /
    • pp.158-167
    • /
    • 1999
  • Heat and moisture transfer associated with porous materials are investigated. The heat and moisture transfer in porous materials caused by the interaction of moisture gradient, temperature gradient, conduction, and evaporation are considered. The variations of temperature and moisture not only change the volume but also induce the hygro-thermal stress. The finite element formulation for solving the temperature and moisture transfer as well as the associated hygro-thermal stresses is developed. In order to verify the finite element formulation, the heat and moisture moving boundary problem in a half space and the hygro-thermo-mechanical problem in an infinite plate with a circular hole are analyzed. Temperature profile, moisture profile, and hygro-thermal stresses are compared with those of analytic solution and other investigator. Good agreements are examined

  • PDF

Carbon Dioxide Absorption in a Packed Column Using Guanidine-based Superbase Solution (구아니딘계 초염기 흡수제에 의한 충진탑에서의 이산화탄소 포집 특성)

  • Choi, Young Min;Hong, Yeon Ki;You, Jong Kyun
    • Korean Chemical Engineering Research
    • /
    • v.54 no.5
    • /
    • pp.648-652
    • /
    • 2016
  • The study of $CO_2$ absorption in a packed column by 1,1,3,3-tetramethylguanidine (TMG) dissolved in ethylene glycol is presented. Absorption column of inner diameter 1 in and 0.6 m length was filled with Protruded-packing $0.16in{\times}0.16in$. We investigated the effect of operating conditions on overall mass transfer coefficients as well as on $CO_2$ removal efficiency. The loading values reached at about $1.0mol_{CO2}/mol_{TMG}$. In case of absorbent with lean $CO_2$ loading, the overall mass transfer coefficient was proportional to the concentration of TMG. However, in the range of more than ${\alpha}=0.5molCO_2/molTMG$, the overall mass transfer coefficients decreased with the concentration of TMG. It is due to the increasing of mass transfer resistance in liquid phase as increasing of viscosity at higher loading values.

Effects of Double-diffusive Convection on the Mass Transport of Copper Ions in a Horizontal Porous Layer (수평 다공성유체층에서 이온의 물질전달에 대한 이중확산대류 효과)

  • Yoon Do-Young;Kim Min Chan;Choi Chang Kyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.2
    • /
    • pp.98-105
    • /
    • 1999
  • In the present study, buoyant force and its stabilizing effects in an electrostatic field were examined systematically in order to reduce the effect of natural convection with thermal stratification in a horizontal fluid-saturated porous layer. The correlation of ionic mass transport induced by double-diffusive convection in a horizontal porous layer has been derived theoretically. And the theoretical model was examined by electrochemical experiments. The theoretical correlation for mass transport which is satisfying Forchheimer's flow equation and based on the micro-turbulence model is derived as a function of soltual Darcy-Rayleigh number, thermal Darcy-Rayleigh number and Lewis number. In the experiment, the mass transport of copper ions in $CuSO_4-H_2SO_4$ solution is measured by electrochemical technique. By assembling theoretical correlation and experimental results, the mass transport correlation induced by double-diffusive convection is proposed as $$Sh=\frac{0.03054(Rs_D-LeRa_D)^{1/2}}{1-3.8788(Rs_D-LeRa_D)^{-1/10}}$$ The present correlation looks flirty reasonable with comparing experimental results, and very promising for the applications of its prototype into various systems involving heat transfer as well as mass transfer, in order to control the effects of natural convection effectively.

Numerical Study of Heat and Mass Transfer Characteristics in Microchannel Steam Methane Reforming Reactor (마이크로채널 메탄 수증기 개질 반응기의 열 및 물질 전달 특성에 관한 수치해석 연구)

  • Jeon, Seung-Won;Lee, Kyu-Jung;Cho, Yeon-Hwa;Moon, Dong-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.9
    • /
    • pp.885-894
    • /
    • 2012
  • A numerical study of a microchannel steam methane reforming reactor has been performed to understand the characteristics of heat and mass transfer. The integration of Rh-catalyzed steam methane reforming and Pt-catalyzed methane combustion has been simulated. The reaction rates for chemical reactions have been incorporated into the simulation. This study investigated the effect of contact time, flow pattern (parallel or counter), and channel size on the reforming performance and temperature distribution. The parallel and counter flow have opposite temperature distribution, and they show a different type of reaction rate and species mole fraction. As the contact time decreases and channel size increases, mass transfer between the catalyst layer and the flow is limited, and the reforming performance is decreased.

Design and fabrication of multi-band six-port phase correlator using metamaterial (메타물질 구조 다중대역 6단자 위상상관기 설계 및 제작)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.12
    • /
    • pp.2615-2621
    • /
    • 2010
  • The multi-band six-port phase correlator using metamaterial was designed and fabricated in this paper. The lumped metamaterial structure that can process the dual-band receiving signal was analyzed. Based on the analyzed results, the small-sized metamatrial six-port phase correlator for multi-band direct conversion method was proposed and fabricated. Also, the resistive power divider and $90^{\circ}$ hybrid coupler that comprises the six-port phase correlator were implemented based on the scattering parameters of metamatrial six-port phase correlator. The measured results of the proposed six-port phase correlator show the good agreement with simulation results. The performance of the six-port phase correlator shows the reflection loss below -20 dB in the dual-band. Also, the proposed six-port phase correlator got a good transmission characteristic within 1 dB gain difference and ${\pm}4.1^{\circ}$ phase imbalance, respectively.