• 제목/요약/키워드: 물분무

검색결과 337건 처리시간 0.022초

주 변압기실 화재시나리오에 적용한 미세물분무 노즐의 소화성능 (Performance of Fire Extinguishing of Water Mist Nozzle for Power Transformer Fire Scenario)

  • 이경덕
    • 한국안전학회지
    • /
    • 제21권6호
    • /
    • pp.46-54
    • /
    • 2006
  • Fire extinguishing experiment was conducted with water mist nozzle in case of the pool fire, cascade fire and spray fire on flammable liquid of class B whether water mist system can be effective system for power transformer fire scenario. In the event of a pool fire, flow rate and time to extinguish was inclined to be increased according to the obstruction rate of ignition space. Furthermore, the performance of fire extinguishing depended upon the spraying angle of the nozzles. In case of cascade fire, the effect of extinguishment was began to show from a combustion pan filled with fuel and fuel flowing plate later on.

수분조절 및 젖산균 첨가가 연맥 및 헤어리 베치의 사일리지 품질에 미치는 영향

  • 신동은;김동암;김원호;신재순;김정갑;전병태;박형수
    • 한국초지학회:학술대회논문집
    • /
    • 한국초지조사료학회 1999년도 제24회 정기총회 및 프로그램, 제37회 학술발표회 및 특별강연 초록
    • /
    • pp.99.1-100
    • /
    • 1999
  • 본 연구는 연맥 및 헤어리 베치를 사일리지로 이용하기 위하여 예건 및 젖산균 첨가에 따른 사일리지 품질에 미치는 영향을 구명코자 축산기술연구소 초지사료과에서 실시하였다. 젖산균 첨가량은 원물 100톤 기준으로 젖산균 1,135g에 물 100$\ell$ 혼합하여 24시간 배양하여 분무하였다. 연맥 및 헤어리 베치의 예취 직후 건물률이 각각 18.4%와 15.9%에서 3일 예건했을 경우 26.5%와 29.9%로 사일리지 조제에 좋은 조건이었다.(중략)

  • PDF

Al-Mg 코팅막의 내식특성에 대한 열처리의 영향 (Influence of Post Heat Treatment on Corrosion Resistance of Al-Mg coating Films)

  • 강재욱;박준무;강준;정재인;양지훈;이명훈
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2014년도 추계학술대회 논문집
    • /
    • pp.308-308
    • /
    • 2014
  • 본 연구에서 PVD법중 하나인 스퍼터링(sputtering)법에 의해 제작된 Al-Mg 코팅막은 SEM, GDS, XRD를 통해 표면 및 단면의 조성분포를 분석하였으며, 내식성을 평가하기 위하여 함량별, 열처리 조건별 Al-Mg 막을 각각 5% NaCl 염수분무 환경 및 3% NaCl 자연침지 환경에 노출시켰다. 막의 내식 특성에 영향을 미치는 열처리의 영향을 알아보기 위하여 열처리-비열처리간 재료 특성 및 내식성평가 결과의 연관성을 비교-분석하였다. 열처리 결과 Al-Mg계 금속간 화합물 $Al_3Mg_2$$Al_{12}Mg_{17}$이 관찰되었으며 내식성 평가 결과, 열처리 Al-Mg 막은 비열처리 Al-Mg 막과 비교하여 양호한 내식성을 나타냈었다. 열처리를 통해 마그네슘(Mg) 성분이 대부분 금속간 화합물상으로 존재함에 따라 균일하게 분포하여 치밀한 부식생성물을 형성하게 되고, 이에 따라 Al-Mg 막 내식성에 기여한 것으로 사료된다.

  • PDF

액체 로켓용 2중 충돌(F-O-O-F)형 분사기의 미립화 특성에 관한 연구

  • 권기철;조기순;오제하;강신재
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 1999년도 제13회 학술강연논문집
    • /
    • pp.2-2
    • /
    • 1999
  • 본 연구에서는 액체 로켓용 추진제 분사기로 많이 활용되는 충돌형 분사기중에서 2중 충돌(F-O-O-F)형 분사기에 대한 미립화 특성을 파악하였다. 액적의 크기를 측정하기 위하여 위상/도플러 입자분석기를 사용하였으며, 모의 추진제로 물을 사용하였다. 모의 추진제의 운동량비와 압력 강하량 변화에 따른 2중 충돌(F-O-O-F)형 분사기의 미립화 특성과 크기분포에 대하여 고찰하였다. 분사기 면으로부터 100mm 떨어진 단면에서 산화제/연료의 운동량비가 MR=1.19에서 MR=6.48까지 증가함에 따라 액적크기(SMD)는 감소하였으며, 액적크기(SMD)가 운동량비(MR)에 대하여 SMD= 193.480+15.687MR-5.036M$R^2$+0.415MR$^3$와 같은 관계식에 근사되었다 또한, 연료와 산화제의 압력강하량이 증가할수록 액적크기(SMD)가 감소하였다. 충돌 분무유동장의 액적크기 분포는 Rosin-Rammler 분포함수와 Upper-limit분포함수 모두에 대하여 잘 일치하고 있다. 본 연구의 결과는 액체 로켓용 충돌형 분사기의 초기 설계단계에서 유용하게 사용될 수 있을 것이다.

  • PDF

불활성 압축가스를 이용한 미세물분무 소화시스템의 유류화재 소화특성 (Extinguishing of Oil Fire by Water Mist Suppression System Using Compressed Inert Gas)

  • 신창섭;전고운;김기환
    • 한국안전학회지
    • /
    • 제25권6호
    • /
    • pp.109-114
    • /
    • 2010
  • Water mist fire suppression system is environmental system and needs a flange pump to jet water. In this research, high pressure Nitrogen cylinder is used as a pressurizing source instead of flange pump, and also we tried to find the possibility of using compressed Nitrogen as a fire suppression agent. As a result, it was possible to design water mist fire suppression system with Nitrogen cylinder and suppress oil fire effectively. With DK1.58 nozzle, the optimum Nitrogen pressure was 80bar and the pressure was stable during water mist spray. However, jet of Nitrogen was not effective fire suppression agent when it was dually used with water mist because water mist has blown away, and it is efficient way to use compressed Nitrogen as a pressurizing source only.

미세물분무를 이용한 PPV의 화재진압효과 (Fire Suppression Effect of PPV with Water Mist System)

  • 김성원;신창섭
    • 한국안전학회지
    • /
    • 제18권4호
    • /
    • pp.71-77
    • /
    • 2003
  • To inject fresh air into a fire room, Positive Pressure Ventilation (PPV) can be used and the blower of PPV increases inside pressure of the room. It makes high flow rate of products of combustion, smoke and heat from the structure, and it is very helpful to fireman on the fire extinguishing work. The flame moves to the direction of airflow and the temperature of flame can be decreased rapidly. In this experiment, a water mist system is applied to PPV to increase the effectiveness, and various effective factors are studied. n-Heptane and pine wood stick were used as fuel. Temperatures at the above and behind the combustion pan were strongly reduced by the water mist system and by the convective cooling with airflow. The smoke density was also decreased by PPV with water mist system and it can be explained by the absorption of smoke particles on the water mist droplet and by the strong exhausting effects of mobile fan.

AZ91D 마그네슘합금에 대한 MAO 표면처리 연구 (A study of Micro-arc oxidation process on AZ91D magnesium alloys)

  • 임진환;손호상;유재인;유재용;김진희
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2007년도 춘계학술발표회 초록집
    • /
    • pp.126-127
    • /
    • 2007
  • AZ91D 마그네슘합금상에 MAO방법을 통한 산화막 성장에 관해 연구하였다. 주요 처리조성물은 NaOH, $Na_3\;C_6H_5O_7$, $Na_4\;P_2\;O_7$이며, 양극에 Mg 샘플을, 음극에 스텐레스 플레이트를 고정하여 설치후 인가전압 50V, 2분간에 걸쳐 Mg 표면에 Micro arc에 의한 산화막이 성장되었다. 산화막 측정 결과 20회 시행후 평균 15.5um 두께를 가졌으며, 막 성장후 표면은 균일하였으며, 밝은 갈색을 띄었다. 염수농도 5%의 염수분무테스트에서는 72시간 경과후에도 5%이내의 우수한 내부식성을 보였다.

  • PDF

온실의 냉방부하 및 포그시스템의 증발효율 실험분석 (Empirical Analysis on the Cooling Load and Evaporation Efficiency of Fogging System in Greenhouses)

  • 남상운;서동욱;신현호
    • 생물환경조절학회지
    • /
    • 제24권3호
    • /
    • pp.147-152
    • /
    • 2015
  • 온실의 냉방부하 산정방법 개발을 위하여 열수지 방법에 기초한 냉방부하 산정식을 구성하고, 포그냉방 온실에서 냉방부하를 실측하여 검증하였다. 포그냉방 온실의 냉각열량은 포그분사에 의한 증발수량에 물의 증발잠열을 곱하여 구할 수 있다. 여기서, 증발수량은 포그 분사량에 증발효율을 곱하면 구할 수 있으며, 즉 분무수량을 계측하고 포그시스템의 증발효율을 알면 온실의 냉방부하를 실측할 수 있다. 따라서 온실의 냉방부하 실측을 위하여 실험온실에서 포그시스템의 증발효율을 실험하고, 실험온실의 열환경 계측과 더불어 포그 분사량을 계측하여 냉방부하 산정방법을 검토하였다. 먼저 냉방부하 산정식의 환기전열량을 검토하기 위하여 냉방을 실시하지 않은 상태에서 환기량 실측 실험을 통해 비교한 결과 열수지식을 이용한 환기전열량 예측은 비교적 양호한 결과를 보이는 것으로 나타났다. 이류체 포그시스템의 증발효율은 0.3~0.94의 범위를 보였으며 평균 0.67로 나타났고, 환기율이 증가함에 따라 커지는 것으로 나타났다. 포그냉방을 실시하면서 온실의 환경을 계측하여 열수지식으로 냉방부하를 계산하고, 분무량 실측치로부터 증발 냉각열량을 구하여 비교한 결과 냉방부하 계산치와 실측치는 대체로 유사한 경향을 보이는 것으로 나타났다. 냉방부하가 낮은 경우에는 실측치에 비하여 약간 크게 예측되었고, 냉방부하가 높은 경우에는 실측치보다 작게 예측되었다. 온실의 냉방시스템 설계 시에는 최대냉방부하를 이용하여 냉방설비의 용량을 결정하게 된다. 따라서 냉방부하가 큰 쪽에서 실측치보다 작게 예측되는 부분은 검토가 필요하지만 설비용량 산정시의 안전계수를 고려하면 본 연구에서 제시한 냉방부하 산정방법은 온실의 환경설계에 적용할 수 있는 것으로 판단된다.

Stainless steel에 접종된 식중독 미생물에 대한 천연항균제 및 유기산 분무 살균효과 (Efficacy of Aerosolized Natural Antimicrobial and Organic Acids as a Sanitizer against Foodborne Pathogens on Stainless Steel)

  • 하수정;양승국;박현주;김충환;오세욱
    • 한국식품위생안전성학회지
    • /
    • 제26권4호
    • /
    • pp.336-341
    • /
    • 2011
  • 본 연구는 Escherichia coli O157:H7, Salmonella Typhimurium 그리고 Listeria monocytogenes에 대하여 천연항균제와 유기산을 이용한 분무 살균제 (aerosol sanitizer)의 살균효과를 검토하였다. 실제 가공공장의 주요 기계나 기구로 사용하는 stainless steel을 coupon으로 이용하여 인위적으로 접종한 식중독 미생물을 model cabinet에서 5분 동안 자몽종자추출물(grapefruit seed extract), acetic acid, citric acid 그리고 lactic acid로 처리 하였다. 3가지 식중독 미생물의 수는 GEF와 유기산 단독 처리시 0.34-3.77log의 균 감소를 나타내었고, 병행 처리시 1.72-3.89 log의 균 감소를 나타내었고 GEF, 유기산 그리고 알코올을 병행 처리시 1.46-5.05 log의 균 감소효과를 나타냈다. 세 종류의 유기산 중 항균력이 가장 높은 것으로 측정된 lactic acid를 이용하여 scale-up 모델에서 10분 동안 처리 한 결과는 E. coli O157:H7, S. Typhimurium 그리고 L. monocytogenes는 각각 3.42, 2.72, 2.30log의 균 감소를 나타내었다. 따라서 천연항균제와 유기산을 이용한 분무 살균제는 안전한 식품에 대한 소비자의 수요를 충족시키고, 환경 위생 방법으로 사용할 수 있다고 생각되었다.

증발냉각을 이용한 배기열 회수장치의 성능에 관한 연구 (Performance of Heat Recovery System using Evaporative Cooling)

  • 유성연;김태호;김명호
    • 대한기계학회논문집B
    • /
    • 제39권1호
    • /
    • pp.37-43
    • /
    • 2015
  • 현열 뿐만 아니라 잠열을 이용하는 증발냉각은 배기열 회수에 매우 유용하게 사용될 수 있다. 본 연구의 목적은 증발냉각을 이용한 배기열 회수장치의 성능을 실험적으로 규명하는 것이다. 성능실험장치는 플라스틱 열교환기, 물 분무 노즐, 공기유동용 홴, 물 순환용 펌프, 수조, 온도 습도 유량 측정 센서 등으로 구성되었다. 증발이 없는 현열 회수에서의 유용도와 증발을 수반하는 전열 회수에서의 유용도를 여러가지 작동조건에서 측정하여 비교하였다. 현열냉각과 증발냉각의 유용도는 공기의 유량이 증가함에 따라 감소하고, 대향류에서의 유용도가 평행류에서의 유용도 보다 휠씬 높다. 증발냉각의 경우 물 유량이 증가함에 따라 유용도는 증가하고, 평행류가 대향류보다 물 유량에 더 민감함을 알 수 있다.