Structure Design and Thermal Analysis of Cryogenic Cooling System for a 1500 A, 400 mH Class HTS DC Reactor (1500 A, 400 mH급 초전도 직류 리액터용 극저온 냉각 시스템 구조 설계 및 열 해석)

  • Quan, Dao-Van;Le, Tat-Thang;Sung, Hae-Jin;Park, Min-Won;Yu, In-Keun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.1
    • /
    • pp.31-41
    • /
    • 2018
  • This paper discusses a structure design and thermal analysis of cryogenic conduction cooling system for a high current HTS DC reactor. Dimensions of the conduction cooling system parts including HTS magnets, bobbin structures, current leads, support bars, and thermal exchangers were calculated and drawn using a 3D CAD program. A finite element method model was built for determining the optimal design parameters and analyzing the thermo-mechanical characteristics. The operating current and inductance of the reactor magnet were 1,500 A, 400 mH, respectively. The thermal load of the HTS DC reactor was analyzed for determining the cooling capacity of the cryo-cooler. Hence, we carried out the operating test of conduction cooling system of the 1st stage area with high current flow. The cooper bars was cooled down to 40 K and HTS leads operated stably. As a experiment result, the total heat load of the 1st stage area is 190 W. The study results can be effectively utilized for the design and fabrication of a commercial HTS DC reactor.

MIRIS 우주관측카메라 FM Dewar 설계

  • Cha, Sang-Mok;Mun, Bong-Gon;Jeong, Ung-Seop;Lee, Dae-Hui;Nam, Uk-Won;Park, Yeong-Sik;Lee, Chang-Hui;Park, Seong-Jun;Lee, Deok-Haeng;Ga, Neung-Hyeon;Han, Won-Yong;Park, Jang-Hyeon;Seon, Gwang-Il;Yang, Sun-Cheol;Park, Jong-O;Lee, Seung-U;Lee, Hyung-Mok;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.40.2-40.2
    • /
    • 2010
  • MIRIS 우주관측카메라는 과학기술위성 3호의 주탑재체로서 $0.8{\sim}2.0{\mu}m$의 근적외선영역에서 우주배경복사와 우리은하 평면의 Pa-$\alpha$ survey 관측을 목적으로 한다. 이러한 임무를 수행하기 위해 MIRIS 우주관측카메라에는 MCT(HgCdTe) IR 검출기가 사용되고 6개의 필터를 장착할 수 있는 필터휠이 설계되었으며, 열잡음을 줄이고 원하는 SNR을 얻기 위해 모두 100K 이하로 냉각이 요구된다. 효과적인 냉각 및 저온유지를 위해서 외부의 열을 1차적으로 차단하는 Cryostat 외부용기와 100K 이하로 냉각되는 내부 Cold Box의 이중구조를 가지는 Dewar가 설계 되었다. 내부 Cold Box의 냉각은 소형 stirling cooler로 이루어지고 외부의 열 유입량이 Cooler의 냉각용량을 넘지 않도록 설계하였다. Cryostat 외부용기는 radiation cooling으로 냉각되어 200K 이하의 온도를 유지하며 내부 Cold Box로의 열유입을 최소화하기 위해 GFRP(Glass Fiber Reinforced Plastic) 단열 지지대와 MLI(Multi Layer Insulation)가 사용된다. 또한 100K으로 냉각시 필터고정부와 Cold Box 구조에서 일어날 수 있는 구조적인 피로도를 줄이고 열변형에 의한 문제를 방지하기 위한 고려가 설계에 포함되었다. FM(Flight Model)은 고진공 환경의 우주공간에서 문제가 발생하지 않도록 설계되었다. 또한 EQM 진동시험결과를 토대로 발사환경에서 발생하는 강한 진동을 견딜 수 있도록 FEM(Finite Elements Method) 구조해석을 통하여 필터고정부에 flexible structure 설계와 완충제를 추가하고 필터휠 구동부와 harness 고정부 및 cooler 지지부를 비롯한 전체 구조물에서 충분히 진동을 극복할 수 있도록 설계하였다.

  • PDF

Numerical Study on Two-phase Natural Circulation Flow by External Reactor Vessel Cooling of iPOWER (혁신형 안전경수로의 원자로용기 외벽냉각 시 2상 자연순환 유동에 대한 수치해석적 연구)

  • Park, Yeon-Ha;Hwang, Do Hyun;Lee, Yeon-Gun
    • Journal of Energy Engineering
    • /
    • v.28 no.4
    • /
    • pp.103-110
    • /
    • 2019
  • The domestic innovative power reactor named iPOWER will employ the passive molten corium cooling system(PMCCS) to cool down and stabilize the core melt in the severe accident. The final design concept of the PMCCS is yet to be determined, but the in-vessel retention through external reactor vessel cooling has been also considered as a viable strategy to cope with the severe accident. In this study, the two-phase natural circulation flow established between the reactor vessel and the insulation was simulated using a thermal-hydraulic system code, MARS-KS. The flow path of cooling water was modeled with one-dimensional nodes, and the boundary condition of the heat load from the molten core was defined to estimate the naturally-driven flow rate. The evolution of major thermal-hydraulic parameters were also evaluated, including the temperature and the level of cooling water, the void fraction around the lower head of the reactor vessel, and the heat transfer mode on its external surface.

Statistical Behavior of RC Cooling Tower Shell due to Shape Imperfection (철근콘크리트 냉각탑의 형상불완전에 의한 확률론적 거동)

  • 최창근;노혁천
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.1
    • /
    • pp.147-158
    • /
    • 2000
  • For the large scale reinforced concrete cooling tower shells, the shape imperfection can be introduced due not only to mistakes in the process of construction but also to the long term behavior of concrete. The shape imperfection evokes the additional responses such as displacements and stresses in addition to the design values. In this study, the statistical behavior of the RC cooling tower shell due to the shape imperfection is investigated using the Monte Carlo simulation. The radius of cooling tower and the shell thickness are adopted as the parameters which cause the shape imperfection. The shape imperfection is modeled as a stochastic field rather than the local one of axisymmetric or bulge type of imperfection. The randomness in the radius is shown to be more affecting the structural responses than the randomness in the shell thickness. In addition to the geometrical randomness, the effect of randomness in the modulus of elasticity on the structural response is also investigated and compared with that of the geometrical ones.

  • PDF

Research Activities of Transpiration Cooling for Liquid Rocket and Air-breathing Propulsions (액체로켓과 공기흡입식 추진기관을 위한 분출냉각의 연구동향)

  • Hwang, Ki-Young;Kim, You-Il;Song, In-Hyuck
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.235-240
    • /
    • 2010
  • Transpiration cooling is the most effective cooling technique for liquid rocket and air-breathing engines operating in aggressive environments with higher pressures and temperatures. Combustor liners and turbine vanes are cooled by the coolant(air or fuel) passing through their porous walls and also the exit coolant acting as an insulating film. However, its practical implementation has been hampered by the limitations of available porous materials. The search for more practical methods of increasing the internal heat transfer within the walls has led to the development of multi-laminate porous structures, such as Lamilloy$^{(R)}$ and Transply$^{(R)}$. This paper reviews recent research activities of transpiration cooling for the propulsions of liquid rocket, gas turbine, and scramjet.

  • PDF

Study on the Fire Behavior of Spring Bed Mattress with and Without a Cooling Frame (냉각프레임 설치 유무에 따른 스프링 침대 매트리스의 화재성상에 관한 연구)

  • Seo, Bo-Youl;Park, Kye-Won;Hong, Won-Hwa
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.24-29
    • /
    • 2018
  • To improve the fire safety of spring bed mattress, a cooling frame including cooling material (water) was made and a cooling frame was installed under the bed mattress or between the bed mattress and bed mattress base; fire tests (real scale) were conducted with or without a cooling frame. Similar fire behavior was observed at the beginning of the test (approximately 3 minutes). Subsequently, rapid fire growth in the mattress without a cooling frame, but with a cooling frame, the decline progressed without growth. The flame spread on the top surface of the bed mattress was similar in the semicircular direction, and the average flame speed velocity was analyzed at approximately 0.005 m/s. The maximum flame height was found to be approximately 2.7 m without a cooling frame, and approximately 1.8 m with a cooling frame installed. In addition, the maximum heat release rate was measured to be approximately 740 kW without a cooling frame, and approximately 400 kW with a cooling frame installed. As a result, the flame height and heat release rate were reduced when the bed mattress was fired through the installed cooling frame.

Water Freezing Behavior in a Rectangular Vessel Cooled from Below Direction (사각형 용기내 물의 하부면 냉각에 의한 동결거동에 관한 연구)

  • Kim, Myoung-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.443-450
    • /
    • 2009
  • This study has dealt with the ice making characteristics in a rectangular vessel cooled from below direction with experiment and numerical analysis. The experiment and numerical analysis were carried out under the following conditions which are the cooling wall temperatures of -5[$^{\circ}C$], -10[$^{\circ}C$], and -15[$^{\circ}C$]. The temperature profile of non-frozen layer was calculated by numerical analysis as the form of non-dimensional temperature. From this study, it is cleared that the existence of natural convection is clearly known. And also the non-dimensional freezing amount was derived from experimental result. This correlation equation will give a useful information to the designers of ice making system.

Thermal Performance of Cooling System for a Laptop Computer Using a Boiling Enhancement Microstructure (비등 촉진 마이크로 구조물을 이용한 휴대용 컴퓨터 냉각시스템의 열성능에 관한 연구)

  • Cho, N.H.;Jeong, W.Y.;Park, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2043-2052
    • /
    • 2008
  • The increasing heat generation rates in CPU of notebook computers motivate a research on cooling technologies with low thermal resistance. This paper develops a closed-loop two-phase cooling system using a micropump to circulate a dielectric liquid(PF5060). The cooling system consists of an evaporator containing a boiling enhancement microstructure connected to a condenser with mini fans providing external forced convection. The cooling system is characterized by a parametric study which determines the effects of volume fill ratio of coolant, existence of a boiling enhancement microstructure and pump flow rates on thermal performance of the closed loop. Experimental data shows the optimal parametric values which can dissipate 33.9W with a film heater maintained at $95^{\circ}C$.

  • PDF

Full-scale Fire Suppression Test for Application of Water Mist System in Road Tunnel (미분무수 소화시스템의 도로터널 적용을 위한 실물 화재 실험)

  • Han, Yong-Shik;Choi, Byung-Il;Kim, Myung-Bae;Lee, Yu-Whan;So, Soo-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.171-174
    • /
    • 2010
  • 도로터널에서의 미분무수 소화시스템의 적용 가능성을 검토하기 위해 실물 화재 실험을 수행하였다. 적용된 화원은 실물 승용차 화재와 유류화재를 모사한 화원면적 $1.4m^2$의 heptane pool 화재이며, 기존 도로터널에 설치된 저압 물분무 시스템과 고압 미분부수 소화시스템과의 냉각효과 비교실험을 수행하였다. 도로터널 내의 환기조건을 구현하기 위해 실물모형 터널의 한 편에 터널 유속(0.9~3.8 m/sec 범위) 발생장치를 설치하였으며, 화원에서 하류 방향으로 터널 내 온도분포를 측정하였다. 실험 결과 1/5의 유량을 사용하는 고압 미분무수 소화시스템은 저압 물분무 시스템과 동등한 수준의 냉각효과를 보였다.

  • PDF

Analysis on the Cooling Characteristics of a Channel with Pin-Fin Structure (핀-휜 구조물을 이용한 채널의 냉각특성 해석)

  • 신지영;손영석;이대영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.667-673
    • /
    • 2003
  • Recent trends in the electronic equipment indicate that the power consumption and heat generation in a chip increase as the components are miniaturized and the computing speed becomes faster. Suitable heat dissipation is required to ensure the guaranteed performance and reliable operation of the electronic devices. The aim of the present study is to investigate the forced-convective thermal-hydraulic characteristics of a pin-fin heat exchanger as a candidate for cooling system of the electronic devices. The influence of the structure of the pin-fin assembly on heat transfer is investigated by porous medium model. The results are compared with the experimental data or correlations of several researchers for the heat transfer coefficients for the channel flow with pin-fin arrays. Finally, the effects of design parameters such as the pin-fin diameter and the spacing are examined.