• Title/Summary/Keyword: 문 검출

Search Result 314, Processing Time 0.02 seconds

Development and Evaluation of Silicon Passive Layer Dosimeter Based Lead-Monoxide for Measuring Skin Dose (피부선량 측정을 위한 Lead-Monoxide 기반의 Silicon Passive layer PbO 선량계 개발 및 평가)

  • Yang, Seung-Woo;Han, Moo-Jae;Jung, Jae-Hoon;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.781-788
    • /
    • 2021
  • Due to the high sensitivity to radiation, excessive exposure needs to be prevented by accurately measuring the dose irradiated to the skin during radiation therapy. Although clinical trials use dosimeters such as film, OSLD, TLD, glass dosimeter, etc. to measure skin dose, these dosimeters have difficulty in accurate dosimetry on skin curves. In this study, to solve these problems, we developed a skin dosimeter that can be attached according to human flexion and evaluated its response characteristics. For the manufacture of the dosimeter, lead oxide (PbO) with high atomic number (ZPb: 82, ZO: 8) and density (9.53 g/cm3) and silicon binders that can bend according to human flexion were used. In the case of a dosimeter made of PbO material, the performance degradation has been prevented by using parylene and others due to the presence of degradation due to oxidation, but the previously used parylene is affected by bending, so a new form of passive layer was produced and applied to the skin dosimeter. The characteristic evaluation of the skin dosimeter was evaluated by analyzing SEM, reproducibility, and linearity. Through SEM analysis, bending was evaluated, reproducibility and linearity at 6 MeV energy were evaluated, and applicability was assessed with a skin dosimeter. As a result of observing the dosimeter surface through SEM analysis, the parylene passive layer PbO dosimeter with the positive layer raised to the parylene produced cracks on the surface when bent. On the other hand, no crack was observed in the silicon passive layer PbO dosimeter, which was raised to silicon passive layer. In the reproducibility measurement results, the RSD of the silicon passive layer PbO dosimeter was 1.47% which satisfied the evaluation criteria RSD 1.5% and the linearity evaluation results showed the R2 value of 0.9990, which satisfied the evaluation criteria R2 9990. The silicon passive layer PbO dosimeter was evaluated to be applicable to skin dosimeters by demonstrating high signal stability, precision, and accuracy in reproducibility and linearity, without cracking due to bending.

The Characteristics of Green-glaze on Bricks from the Sacheonwang Temple Site, Gyeongju (경주 사천왕사지 녹유전의 녹유 특성 연구)

  • Lee, Han Hyoung;Jeong, Min Ho;Moon, Eun Jung;Park, Ji Yeon;Kim, Soo Kyung;Choi, Jang Mi;Han, Min Su
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.3
    • /
    • pp.112-131
    • /
    • 2011
  • This article reports the results of scientific analysis using SEM-EDX, XRD, TG/DTA, performed on 5 green glaze samples of the brick and roofing tile excavated from the Sacheonwang temple site in Gyeongju in order to verify the chemical compositions and melting temperature. The glaze samples on 2 clay statues have similar chemical composition (PbO 74~81%, $SiO_2$ 14~18%) and melting temperature range ($970{\sim}1070^{\circ}C$), whereas the 2 tiles of goblin's face and 1 rhomb brick have different characteristics. Sample SC 003 (made of PbO 63~67%, $SiO_2$ 25~28%), one of the tiles of goblin's face, shows low melting temperature range (below $970^{\circ}C$), and sample SC 004 (composed of PbO 64~70%, $SiO_2$ 19~25% and melting point $970{\sim}1070^{\circ}C$), the other tile of goblin's face, shows different chemical characteristics compared with 2 clay statues. The green glaze on rhomb brick shows different composition compared with all the others from Sacheonwang temple site in that it does not show any impurity elements other than the main components (PbO 87~88%, $SiO_2$ 12~13%) with very low melting temperature range ($750{\sim}770^{\circ}C$). Surprizingly, the chemical and optical characteristics of this green-glaze on rhomb brick are very similar to that on the bricks from Yeongmyo temple site, Gyeongju. The above results indicate that raw material and manufacturing method are not same for 5 green-glaze samples from Sacheonwang temple site and therefore suggests that further study on the provenance of raw material such as lead isotope analysis is necessary. Our work will provide basic data for future reproduction study of green glazed brick of Sacheonwang temple site, Gyeongju and will also serve as a reference data for the study of raw material and manufacturing method of green glaze from other sites of cultural assets.

Distribution Status of Invasive Alien Species (Procambarus clarkii (Girard, 1852)) Using Biomonitoring with Environmental DNA in South Korea (생물모니터링 및 환경유전자(eDNA)를 이용한 침입외래종 미국가재(Procambarus clarkii)의 한국분포 현황)

  • Jung, Sang Woo;Lee, Jae-Ha;Kawai, Tadashi;Kim, Phil-Jae;Kim, SuHwan
    • Korean Journal of Environment and Ecology
    • /
    • v.36 no.4
    • /
    • pp.368-380
    • /
    • 2022
  • Biomonitoring of an invasive alien crayfish species, Procambarus clarkii (Girard, 1852), was performed from February to October 2021, along with environmental DNA analysis, at five locations including Wanju-gun, Hampyeong-gun, Naju-si, Gurye-gun, and Cheongju-si. For the investigation, an umbrella-shaped trap for adults and a hand net for young crayfish were used, and 8 to 10L of freshwater was collected for eDNA analysis. The current status and past distributional records of crayfish in Korea were analyzed along with benthic macroinvertebrates at each survey site. As a result of the investigation, a total of 122 individuals were identified, and Hampyeong-gun recorded the largest number of populations with 59 individuals (48.36%) and the highest environmental DNA (eDNA). The frequency of appearance of P. clarkii was highest in May. The ratio of females to males was 21:5, and the body size was 72.2±21.1mm for female, 80.5±15.6mm for male, and 25.3±9.8mm for young crayfish. P. clarkii introduced into Korea is mainly spreading in the southwest region and it has not been observed in Seoul where there had been a record of appearance in the past. No external symbiosis (Branchiobdellida) of P. clarkii has been identified, and P. clarkii that has appeared in Korea was presumed to be imported from Japan. There are more than eight kinds of exotic crayfish distributed in Korea, and among them, the marbled crayfish (P. virginalis) was identified as a harmful species to the ecosystem of Korea by the Ministry of Environment in 2021. The identified species of benthic macroinvertebrates inhabiting the survey area where P. clarkii has appeared were 69 belonging to 39 families, 15 orders, five classes, and three phyla. Among them, Odonata were the most abundant (16 spp.; 24.62%), followed by Coleoptera (11 spp.; 16.92%) and Hemiptera (11 spp.; 16.92%). In the survey area, one Korean endemic species (Rhoenanthus coreanus), one species (Helophorus auriculatus) classified as Near Threatened (NT) on the Korean Red List, and six species of Crustaceans appeared. In the functional feeding group, the predators appeared predominantly while in habitat oriented group, the climbers appeared to be abundant. It was confirmed that P. clarkii in the survey area prefers an area rich in aquatic vegetation with waterside vegetation, and has high resistance to turbid water quality. The omnivore invader P. clarkii is expected to maintain a competitive relationship with carnivorous benthic macroinvertebrates that are predominant in the same species, and is expected to continue to generate ecosystem disturbance along the food chains.

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.