• Title/Summary/Keyword: 문무성

Search Result 194, Processing Time 0.034 seconds

Socket Pressure Distribution of the Uni-Lateral Trans-Femoral Amputee with a Suction Socket (흡착식 소켓을 착용한 일측 대퇴절단환자의 소켓내부압력분포)

  • Jang, Yun-Hui;Yang, Gil-Tae;Im, Song-Hak;Mun, Mu-Seong;Kim, Yeong-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.417-422
    • /
    • 1998
  • The study was explored socket pressure distributions on a trans-femoral amputee with a suction socket in static and dynamic situations. Even when the amputee stood in the anatomically neutral position, significant pressure concentrations were observed in the lateral, medial, and posterior planes of the socket. During free level walking, a significant shifting pattern of pressure concentration areas was observed. High socket pressure was observed in the lateral, medial-anterior and posterior walls during mid-stance or push-off period. Socket pressure measurement will be one of the good tool to determine the optimal socket-limb interface.

  • PDF

Changes of Muscle Activation Pattern of Trunk Muscles during Whole-body Tilts with and without Axial Rotation (전신 기울임 운동시 축 회전 유무에 따른 체간근 활성도 변화)

  • Kim, Sol-Bi;Chang, Yun-Hee;Kim, Shin-Ki;Bae, Tae-Soo;Mun, Mu-Seong;Park, Jong-Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.7
    • /
    • pp.805-810
    • /
    • 2012
  • Determining of the exercise intensity is very important in terms of induction of low fatigue during exercise. Little information is available on the contraction level of the trunk muscles during whole body tilts with and without axial rotation. This study was to investigate the difference muscle activation level according to axial rotation. Twenty subjects were participated. The muscle activities of the five trunk muscles were bilaterally measured at eight axial rotation angles with 12 tilt angles along $15^{\circ}$ intervals. The results showed that tilt with $45^{\circ}$ axial rotation was more balanced in the same tilt angle and was maintained approximately level of 40% MVC at over $60^{\circ}$ tilt angle with respect to co-contraction of abdominal and back muscle. Lumbar stabilization exercise using whole body tilts would be more effective with axial rotation than without axial rotation in terms of muscle co-contraction.

Movements of the Center of Pressure During Stance Phase in Free Level Walking of Normal Adults (정상인의 지면수평자보행에 대한 입각기 압력중심의 이동)

  • 김영호;양길태;문무성;박시복
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.5
    • /
    • pp.587-592
    • /
    • 1999
  • 압력측정시스템은 입각기동안 동적압력분포를 성공적으로 측정할 수 있으나 하중수용기-중간입각기, 말기입각기-전유각기의 전환기들에 대해서는 운동분석시스템을 사용하지않고는 정확한 정의가 불가능하다. 따라서 저자들은 수평자유보행 시 압력중심의 이동을 이해하기 위해서 정상적인 발을 가진 20-30대 성인남자 78명을 대상으로 동작분석과발바닥 압력측정을 동시에 수행하였다. 결과로 하중반응기-중간입각기 전환시기의 발바닥 압력중심점은 후족부와 중족부의 경계선에서 앞쪽으로 1.9$\pm$1.5frame(32$\pm$24msec)에 위치하였으며 말기입각기-전유각기 전환시기에는 중족골두 최대 압력점의 앞쪽으로 2.3$\pm$2.0 frame(38$\pm$33msec)에 위치하였다. 정상수평보행에 있어서 최초접지 순간 압력중심은 전방으로 빠르게 이동하다가 바로 급속히 감소하여 하중반응기-중간입각기의 전환시기에는 작은 속도로 이동하였다. 압력중심의 이동속도는 그 후 다시 서서히 증가하다가 전체 보행주기의 25% 전후에서 서서히 감소하여 비교적 일정하다가 말기입각기-전유각기의 전환시점에서 다시 급격한 증가를 보였다. 족부질환과 보행특성을 판단하는데 있어서 압력중심의 이동궤적은 매우 유용한 인자가 될 것으로 기대된다. 본 연구를 통해서 압력측정시스템만으로는 정의할 수 없었던 두 전환기인 하중반응기-중간입각기, 말기입각기-전유각기를 결정할 수있게 되었다.

  • PDF

Assist Torque Balance Control for Power Assisted Wheelchair Based on Temporal Similarity between Input Torques (입력토크의 시간적 유사성에 기반한 파워 어시스트 휠체어의 토크 밸런스 제어)

  • Heo, Y.;Hong, E.P.;Ryu, J.C.;Moon, M.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.1
    • /
    • pp.81-87
    • /
    • 2015
  • In order for a Power Assisted Wheelchair (PAW) to maintain a straight driving direction, the same force must be delivered to both wheels. However, a human has different strength between the right and left arms, and cannot control the force uniformly at all times. Therefore, appropriate assist torque shall be generated from unbalanced human torque inputs by detecting the user intention, in order to maintain direction uniformly in straight sections or change direction quickly in curved sections. In this study, a special function is proposed to detect the intention of drivers on the basis of temporal similarity between the input torque signals, and a torque balancing technique based on this function is proposed. In the experiments, the effectiveness of the proposed torque balancing method are verified.

  • PDF

Effect of Surface Roughness on the Actuation of Ionic Polymer Metal Composites (표면 조도에 따른 이온성 고분자-금속 복합체의 구동특성)

  • Jung, Sunghee;Song, Jeomsik;Kim, Guoosuk;Lee, Sukmin;Mun, Museong
    • Applied Chemistry for Engineering
    • /
    • v.17 no.6
    • /
    • pp.586-590
    • /
    • 2006
  • As one of electro active polymers for soft smart materials, the ionic polymer metal composites (IPMC) are easy to produce through chemical reduction processing and show high displacements at low voltage. When the IPMC actuates, the deformation depends on a few factors including the structure of based membrane, species and morphology of the metal electrodes, the nature of cations and the level of hydration. As previously published, we have been studying on improvement of actuation through surface electrode modification of IPMC to grasp the effect of electrode morphology on actuation. This study is comparative experiments through the chemical reaction and deposition by ion beam assisted deposition (IBAD) in order to prepare the very thin and homogeneous surface electrode of IPMC. The IPMCs were prepared with different surface roughness of polymer membrane, and the influence of the surface roughness on the actuation was studied. By investigating the electrical properties and driving displacement, the actuating properties of IPMC with different surface roughness were studied.

Effect of the Surface Electrode Formation Method and the Thickness of Membrane on Driving of Ionic Polymer Metal Composites (IPMCs) (표면전극 형성 방법과 이온-교환막 두께가 이온성 고분자-금속 복합체(IPMC) 구동에 미치는 영향)

  • Cha, Gook-Chan;Song, Jeom-Sik;Lee, Suk-Min;Mun, Mu-Seong
    • Polymer(Korea)
    • /
    • v.30 no.6
    • /
    • pp.471-477
    • /
    • 2006
  • Ion exchange metal composite(IPMC) has toughness equivalent to the range of human's muscle, transformation-actuation force by relatively low voltage and the fast response time. Thus, as a new method for preparing thicker IPMC, the solution casting method to make the films of various thicknesses out of liquid nation was attempted in this study. To reduce the surface resistance of electrode, the first plated electrode prepared by Oguro method was replated with Au and Ir using ion beam assisted deposition(IBAD). The microstructures of electrode surfaces before and after IBAD plating were investigated using SEM. The change of water and ion-conductivity in IPMC were measured under applied voltage. The displacement and driving force of IPMCs with various thicknesses were measured to evaluate the driving properties.

On Hwagwan(火官) carved on the tombstone of King Munmu of Silla (문무왕릉비의 화관(火官))

  • Chung, Yeon-sik
    • Journal of Korean Historical Folklife
    • /
    • no.44
    • /
    • pp.7-37
    • /
    • 2014
  • The people of Silla was described as the descendants of Hwagwan(official of fire) on the tombstone of King Munmu(文武王), and Gim Yusin(金庾信) was described as the descendants of Shaohao Jintian(少昊 金天) and Huangdi Xuanyuan(黃帝 軒轅) on his tombstone. It says that the royal households of Silla and Gaya had common ancestor. Hwagwan was the official who took charge of fire management and the ritual for Antares(${\alpha}$ Sco) in ancient China. Hed founded State Ra(羅國). The name of Silla(新羅) means new State Ra, so he could become the ancestor of the people of Silla. He was the son of Zuanxu Gaoyang. State Gaya(加耶), the fatherland of Gim Yusin had been called Geumgwan-gug(金官國) which means the state of official of metal. Geumgwan was the son of Shaohao Jintian. Silla was the state of Hwagwan and the Gaya was the state of Geumgwan. Hwagwan, the founder of the royal household of Silla was the son of Zuanxu and Geumgwan, the founder of the royal household of Gaya was the son of Shaohao. Zuanxu and Shaohao was the descendants of Hwangdi, so Hwangdi was the common ancestor of Silla and Gaya. Finally Hwangdi became the same ancestor of Gim Yusin and King Muyeol(武烈王) who was the father of King Munmu. The tombstone of King Munmu and Gim Yusin manifests the union of the blood of Gim Yusin and King Muyeol. But it was not the fact but the rhetorical fiction.

Analysis of stair walking characteristics for the development of exoskeletal walking assist robot (외골격 보행보조로봇 개발을 위한 정상인의 계단보행특성 분석)

  • Cho, H.S.;Chang, Y.H.;Ryu, J.C.;Mun, M.S.;Kim, C.B.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.6 no.2
    • /
    • pp.15-22
    • /
    • 2012
  • The mechanical system of wearable walking assist robot needs to be optimized for adapting with human body structure and the planned control algorithm should have a secure procedure when a incongruity situation which can cause musculoskeletal injury occurs because a wearable robot is attached to a body. The understanding of walking or musculoskeletal motions characteristics must be preceeded and analyzed for developing novel wearable walking assist robot. In this study we tried to find out the capacities of powers and torques of joint actuators to design optimized performances of system and to obtain the analysis data to figure out the characteristics of joint movements during some types of walk. The major types of walk and motion are stair climbing and descending, sit-to-stand motion, and slope walking. In this study all these motions were analyzed experimentally except slope walking.

  • PDF

Comfort Analysis of Mono-ski with Hydraulic Absorber (모노스키 유압 완충장치 특성에 따른 탑승 안락감 평가)

  • Cho, Hyeon-Seok;Park, Jin-Kook;Kim, Gyoo-Seok;Mun, Mu-Sung;Kim, Chang-Boo
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.2
    • /
    • pp.131-140
    • /
    • 2015
  • The mono-ski for the paraplegia designed to skiing is formed as seat bucket on the sled. The impact force transferred by snow surface during skiing is absorbed by the leg joints of normal human, but it is transferred to the human body on the seat when using mono-ski. Most of commercially available mono-ski have absorbing device and link mechanism between seat and ski mount in order to complement it. In this study we developed the comfort evaluation model that could provide skiing simulation of mono-ski with hydraulic damper and analyzed vibrational acceleration occurred during skiing uneven surface. The evaluation method used in this study is the international standard BS6841. We evaluated comfort performance of mono-ski in accordance with nozzle adjustment of hydraulic damper.

Relationship between lower limb alignment and knee adduction moment during ambulation in the healthy elderly (노인의 하지 정렬 상태와 보행 시 슬관절 내전 모멘트 특성)

  • 조유미;홍정화;문무성
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.24-24
    • /
    • 2003
  • For the elderly, achieving a close-to-normal ambulation is important for activities of daily life. Recent researches of SE(Silver Engineering) restoring physical ability would help the elderly by developing the advanced gait assisting devices and orthoses. For the applications using the advanced technologies, the gait characteristics of the elderly must be understood. However, a few studies were performed to investigate the physiological or pathological gaits. The purpose of this study is to provide the gait analysis data and also to investigate relationships between alignment of the lower limb, foot progression angle and knee joint moments in the healthy elderly. By participating a total of 20 healthy elderly persons in this study, the following facts were found: 1) Cadence showed 114.8 steps/min, gait speed showed 1.05 m/s, time per a stride showed 1.06 sec, time per a step showed 0.53 sec, single-supporting phase was 0.41 sec, double-supporting phase was 0.24 sec, stride length was 1.04m, Step length was 0.56m; 2) The maximum knee flexion angle through swing phase showed left 46.82$^{\circ}$, right 40.19$^{\circ}$ and the maximum knee extension angle showed left -1.32$^{\circ}$, right 2.01$^{\circ}$. Knee varus showed left 26.90$^{\circ}$, right 30.93$^{\circ}$; 3) The maximum knee flexion moment showed left 0.363 Nm/kg, right 0.464 Nm/kg, The maximum knee extension moment showed left 0.389 Nm/kg, right 0.463 Nm/kg. The maximum knee adduction moment showed left 0.332 Nm/kg, right 0.379 Nm/kg. The maximum internal rotational moment showed left 0.13 Nm/kg, right 0.140 Nm/kg; 4) The subjects who had varus alignment of the lower extremity had statistically higher in knee adduction moment in mid stance phase; and 5) The subjects who had large foot progression angle had statistically lower in knee adduction moment in late stance phase.

  • PDF