• 제목/요약/키워드: 무효전력

검색결과 641건 처리시간 0.04초

전압안정성 분석 및 제어에 관한 연구 (A Study on the Analysis and Control of Voltage Stability)

  • 장수형;김규호;유석구
    • 대한전기학회논문지
    • /
    • 제43권6호
    • /
    • pp.869-876
    • /
    • 1994
  • This paper presents an efficient method to calculate voltage collapse point and to avoid voltage instability. To evaluate voltage stability in power systems, it is necessary to get critical loading points. For this purpose, this paper uses linear programming to calculate efficiently voltage collapse point. Also, if index value becomes larger than given threshold value, voltage stability is improved by compensation of reactive power at selected bus. This algorithm is verified by simulation on the IEEE 14-bus sample system.

  • PDF

전압안정도여유를 고려한 무효전력원 배분계획 (The Optimal VAR Planning Considering Voltage Stability Margin)

  • 송길영;최상규;남국재용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.33-35
    • /
    • 1993
  • This paper presents a new optimal VAR planning algorithm considering voltage stability margin. The characteristic of this method is to make it possible to formulate VAR planning for the dual purpose of maintaining voltage profiles within specified limits, and increasing the voltage stability margin of anticipated operating conditions with respect to voltage collapse. The IEEE-30 bus system is used to demonstrate the capability of the proposed algorithm.

  • PDF

순시무효전력 보상에 의한 중성선 전류의 제거 (Eliminating the Neutral Current by the Instantaneous Reactive Power Compensation)

  • 김효성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.131-133
    • /
    • 1998
  • This paper, proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers $q_{q}$, $q_{r}$ were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of the three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storage element.

  • PDF

새로운 벡터적 PLL를 이용한 대용량 무효전력 보상기(SVC)의 DSP 제어 (DSP BASED CONTROL OF HIGH POWER STATIC VAR COMPENSATOR USING NOVEL VECTOR PRODUCT PHASE LOCKED LOOP)

  • 정구호;조국춘;채균;조규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.262-264
    • /
    • 1996
  • This paper presents a new dual loop control using novel vector phase locked loop(VP-PLL) for a high power static var compensator(SVC) with three-level GTO voltage source inverter(VSI). Through circuit DQ-transformation, a simple dq-axis equivalent circuit is obtained. From this, DC analysis is carried out to obtain maximum controllable phase angle ${\alpha}_{max}$ per unit current between the three phase source and the switching function of inverter, and AC open-loop transfer function is given. Because ${\alpha}_{max}$ becomes small in high power SVC, this paper proposes VP-PLL for more accurate $\alpha$-control. As a result, the overall control loop has dual loop structure, which consists of inner VP-PLL for synchronizing the phase angle with source and outer Q-loop for compensating reactive power of load. Finally, the validity of the proposed control method is verified through the experimental results.

  • PDF

시간영역에서의 유효/무효전력을 이용한 마이크로그리드의 단독운전의 판단 알고리즘 (Islanding detection algorithm for a micro-grid based on the active and reactive power in the time domain)

  • 이영귀;이혜원;김연희;정태영;강용철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.145-146
    • /
    • 2011
  • A micro-grid (MG) is usually interconnected to the main grid through the dedicated line. Immediately after the removal of the grid supply, the MG should be disconnected and remain disconnected until the main grid is re-energized. It should detect islanding condition as soon as it happens to adjust the setting of the protection relays in the MG. This paper proposes an islanding detection algorithm for the MG based on the active and reactive power delivered to the dedicated line in the time domain. The performance of the proposed algorithm is verified under islanding conditions and fault conditions using the PSCAD/EMTDC simulator. The results indicate that the proposed algorithm can discriminate the islanding conditions from the various fault conditions.

  • PDF

무효전력 경제급전을 고려한 345㎸ 송전계통의 기준 전압 설정 방법 (Determining the Reference Voltage of 345 kV Transmission System Considering Economic Dispatch of Reactive Power)

  • 황인규;진영규;윤용태;추진부
    • 전기학회논문지
    • /
    • 제67권5호
    • /
    • pp.611-616
    • /
    • 2018
  • In the cost based pool market in Korea, there is no compensation of reactive power because the fuel cost for reactive power is relatively low compared to that of active power. However, the change of energy paradigm in the future, such as widespread integration of distributed renewable energy source, will prevent the system operator from mandating the reactive power supply without any compensation. Thus, in this study, we propose the reference voltage of the 345 kV transmission system that minimizes the reactive power supply. This is closely related to the economic dispatch of reactive power aiming at minimizing the compensation cost for the reactive power service. In order to verify the effectiveness of the proposed reference voltage, the simulations are performed using the IEEE 14 bus system and the KEPCO real networks. The simulation results show that a voltage lower than the current reference value is recommended to reduce the reactive power supply and also suggest that the current voltage specification for the 345 kV system needs to be reviewed.

수동형 필터 적용시 무효전력의 변화에 관한 연구 (Study on the Variation of Reactive Power When Applying the Passive Filter)

  • 김지명;김종겸
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1626-1631
    • /
    • 2016
  • Generally, the low-voltage customer has been used with a linear load and nonlinear load in the 3-phase 4-wire distribution system. Linear load has usually configured the resistance and inductance, current phase is slower than the voltage phase, so power factor is low. It is required for the power factor correction device prior to the phase of the current than the voltage. The capacitor is connected in parallel to the load in order to ensure a low power factor. Power converter such as an inverter is a typical non-linear load. Non-linear load generates harmonic currents in the energy conversion process. Many electrical equipment may be adversely affected by the harmonic current. There, passive or active filter have been used to reduce these harmonics current. Passive filter consisting of inductor and capacitor generates a reactive power. According to the combination of filter inductor and capacitor, reactive power can be adjusted. In this paper, we analyzed how the combination of inductor and capacitor affects the overall power factor by simulation and measurement.

광역계통 전압/무효전력 관리를 위한 전압관리시스템의 개발 및 현장설치 (Development and Installation of Voltage Management System for Voltage and Reactive Power Control of Wide Area System)

  • 남수철;신정훈;백승묵;이재걸;문승필;김태균
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1540-1548
    • /
    • 2010
  • KEPCO proposes enhanced voltage management system that is a coordinate voltage control system between the hierarchical voltage control system and the slow voltage control system. It has been installing in Jeju island. VMS consists of a master controller, CVC (Continuous Voltage Controller) and DVC (Discrete Voltage Controller). CVC consists of main controller, FDMU (Field Data Measurement Unit) and several RPDs (Reactive Power Dispatcher). CVC has a control scheme with AVRs of generator to maintain the voltage of a pilot bus in a power system, DVC has a control scheme with static reactive power sources, like a shunt capacitor, a shunt reactor, ULTC and so on, to maintain the reactive power reserve of a power system and a master controller is executed to recover reactive power margin of a power system through coordinated control between CVC and DVC.

고조파와 무효전력 보상기능을 가지는 Smart PCS의 새로운 제어 알고리즘 (Novel control algorithm for smart PCS with harmonics and reactive power compensation)

  • 서효룡;장성재;박상수;김상용;김경훈;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1053_1054
    • /
    • 2009
  • A significant number of renewable energy systems have been connected to the grids as supplement power source. The renewable energy systems require control algorithm to maintain the power-supply reliability and quality. This paper proposes a novel control algorithm for smart Power Conditioning System (PCS) with harmonics and reactive power compensation. The smart PCS is used to feed Photovoltaic (PV) power to utility and compensate harmonics and reactive power at the same time. The experimentation is carried out on the proposed grid-connected PV generation system, and controlled by digital signal processor. The grid-connected PV generation system injects PV energy into the grid and performs as Active Filter (AF) and Static Synchronous Compensator (STATCOM) without additional devices. The experiment results show that the proposed control algorithm is effective for smart PCS with harmonics and reactive power compensation.

  • PDF

무효전력을 보상하는 축소형 ITER 전원공급장치의 순차제어 (Sequence Control of Small-scaled ITER Power Supply for Reactive Power Compensation)

  • 허혜성;박기원;안현식;장계용;신현석;최정완;오종석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.932_933
    • /
    • 2009
  • A technology based on thyristors will be used to manufacture the super-conducting coil AC/DC converters because of the low ratio of cost over installed power compared to a design based on GTO or similar technology. But phase-controlled converter suffers from fundamental disadvantage. They inject current harmonics into the input ac mains due to their nonlinear characteristics, thereby distort the supply voltage waveform, and demand reactive power from the associated ac power system at retarded angles. To overcome this disadvantage, in the case of two series converters at the DC side, connected to the same step-down transformer, apply for the sequence control. It is the most simple and efficient way to reduce the reactive power consumption at low cost. Analytical sequence control algorithm is suggested, the validity of the proposed scheme has been verified by experimental results with the small-scaled International Thermonuclear Experimental Reactor (ITER) Power Supply to minimize reactive power consumption.

  • PDF