• Title/Summary/Keyword: 무전극 램프

Search Result 130, Processing Time 0.023 seconds

The surge characteristics research of an electrodeless fluorescent lamp system (무전극 형광램프 시스템의 서어지 특성 연구)

  • Lee, Se-Hyun;Shin, Sang-Wuk;Cho, Mee-Ryoung;Hwang, Myung-Keun;Ham, Jung-Keol
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.141-148
    • /
    • 2004
  • In this paper, we have investigated the inductive voltages, currents, frequencies of output line of electrodeless fluorescent lamp system as an surge is supplied and have analyzed the surge characteristics as an phase alteration of input voltage with an surge suppling. A result os measurement is that the inductive over-voltages(H-PE, N-PE) on output line of electrodeles fluorescent lamp system showed more high than inductive overvoltages of H(hot)-N(neutral) line. Therefore, designer of system will lay emphasis on an protective circuit with considening an overvoltage(H-PE, N-PE) or phase of input voltage.

  • PDF

Electromagnetic Field Distribution of Electrodeless Fluorescent Lamps (무전극 형광램프의 페라이트 특성변화에 따른 전자계 분포)

  • 김광수;이영환;조주웅;최용성;박대희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.2
    • /
    • pp.79-82
    • /
    • 2004
  • The RF inductive discharge or inductively coupled plasma (ICP) continues to attract growing attention as an effective plasma source in many industrial applications, the best known of which are plasma processing and lighting technicology. Although most practical ICP operate at 13.56 [MHz]and 2.65 [MHz], the trend to reduce the operating frequency is clearly recognizable from recent ICP developments. In an electrodeless fluorescent lamp, the use of a lower operating frequency simplifies and reduces cost of rf matching systems and rf generators and can eliminate capacitive coupling between the inductor coil and plasma, which could be a strong factor in wall erosion and plasma contamination. In this study, the configuration of ferrite and fixture which operates at the frequency of 2.65[MHz]was discussed as functions of the ferrite thickness and distance by using the electromagnetic simulation software (Maxwell 2D).

Electrodeless Fluorescent Lamp System using A New ZVT-PWM boost Converter (ZVT-PWM 부스트 컨버터를 이용한 무전극 램프 구동 시스템)

  • Lee, H.M.;Lee, H.W.;Koh, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1175-1177
    • /
    • 2003
  • In this paper, an application of the ZVT-PWM(zero-voltage-transition) boost converter, which has great advantage on miniaturization and high power density, to the power factor correction circuit of the EFL(electrodeless fluorescent lamp) inverter is studied. The operation principles of the converter are described to identify the power factor correction characteristic of the inverter. Experimentally obtaining the high power factor above 0.99, it is verified that the power factor correction of the EFL inverter successfully achieved.

  • PDF

Impedence and Q-factor of frequence dependance accoding to ferrites on electrodeless fluorescent lamp (무전극 형광램프의 주파수에 따른 임피던스 및 Q-factor 변화 연구)

  • Pack, Gwang-Hyoen;Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Jong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.153-156
    • /
    • 2004
  • An electric power efficiency of electrodeless fluorescent lamp has big relative property of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. We have examined resistance kind, impedance, Q-factor's frequency characteristic by ferrite. Impedance, resistance and capacitance did not show difference in start frequency 2.65 [MHz] but there was difference quantity. We could know Q-factor's difference according to material, and Q-factor's is important part of antenna design.

  • PDF

Brightness special Quality change of wireless electrodeless fluorescent lamp by ferrite change (페라이트 변화에 따른 무전극 형광램프의 휘도 특성 변화)

  • Pack, Gwang-Hyoen;Yang, Jong-Kyung;Lee, Jong-Chang;Choi, Yung-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.171-176
    • /
    • 2004
  • An electric power efficiency of electrodeless fluorescent lamp has big relative propertye of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. Coill turn was changed from 13th to 15th turn to recognize brightness change of lamp by winding number. Optical equipment that used in an experiment was used to measure brightness (LS-100). When an electrodeless fluorescent lamp was made using and T company's PE22, was it showed the highest brightness. As number of winding is increased the brightness increased, and starting characteristic became good.

  • PDF

Electric & Optical Characteristics of Electrodeless Fluorescent Lamp by Changing Ferrite Position (무전극 형광램프의 페라이트 위치변화에 따른 전기적, 광학적 특성)

  • Lee, Joo-Ho;Yang, Jong-Kyung;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.244-245
    • /
    • 2007
  • The RF inductive discharge of inductively couples plasma (ICP) continues to attract growing attention as an effective plasma source in many industrial applications, the best known of which are plasma processing and lighting technology. Although most practical ICPs operate at 13.56 [MHz] and 2.65 [MHz], the trend to reduce the operating frequency is clearly recognizable from recent ICP developments. in and electrodeless fluorescent lamp, the use of a lower operating frequency simplifies and reduces cost of RF matching systems and RF generators and can eliminate capacitive coupling between the inductor coil and plasma, which could be a strong factor in wall erosion and plasma contamination. In this study, electric and optical characteristics of electrodeless fluorescent lamp by changing ferrite position is discussed.

  • PDF

Temperature Dependence of Round type electrodeless lamp (둥근형 무전극 램프의 온도 의존성)

  • Kim, Nam-Goon;Yang, Jong-Kyung;Lee, Joo-Ho;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.246-247
    • /
    • 2007
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above ail, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours and is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. In this paper, when appling the electrodeless lamp in luminaire, We analyzed change of optical and electrical characteristics.

  • PDF

Optical and Electromagnetic Distribution of Ring-shaped Electrodeless Fluorescent Lamps (환형 무전극 램프의 광학적, 전자계적 특성)

  • 조주웅;이성진;최용성;김용갑;박대희
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.161-163
    • /
    • 2003
  • Ring-shaped electrodeless fluorescent lamp is removed the internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250[㎑]and some specific conditions. The optical measurement measured luminance and a temperature and an optical spectrum distribution for 10 minutes in a one minute interval at the same time.

  • PDF

Dependence of Round type electrodeless lamp according to Ferrite shape (페라이트 형상에 따른 둥근형 무전극 램프의 의존성)

  • Kim, Nam-Goon;Yang, Jong-Kyung;Lee, Joo-Ho;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.465-466
    • /
    • 2007
  • In electrode-less lamp, The key point in creating an efficient light source based on RF discharge is to minimize the RF power loss in the RF coupler which for Anderson's type of RF lamp is due to losses in the ferrite core. This loss depends on the particular ferrite material, its size, geometry, frequency in this kind of inductive lamp shows that the correct choice of discharge current has a crucial effect on the core loss. In this study, we measured Ferrite temperature in normal state, then analyzed electrical and optical characteristics according to ferrite shape. We were able to know that was ferrite of the antenna had relate closely with temperature and luminous of the lamp. Also we appraised temperature and electrical, optical properties during turn on the lamp.

  • PDF

Hysteresis and Mode Transition in Electrodeless Fluorescent Lamp (무전극 램프에서의 히스테리시스와 모드 변환)

  • Lee, Joo-Ho;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.453-453
    • /
    • 2007
  • Electrodeless fluorescent lamp exhibit two modes of operation: a low density mode in which the power is capacitively coupled to the plasma and which is known as the E-mode, and a higher density mode which is an inductive discharge known as the H-mode. The transition between these two(E to H) mode exhibits hysteresis. It is observed that transition currents change at different frequencies and hysteresis exists not only between the starting and minimum maintaining currents of the electromagnetic mode (H mode) discharge but also between the starting and minimum maintaining currents of the electrostatic mode (E mode) discharge. Hysteresis effect can be important role in dimming system.

  • PDF