Evaluating the Efficiency of the Device in Shielding Scattered Radiation during Treatment of Carcinoma of the Penis (음경암의 방사선치료 시 자체 제작한 Device의 산란선 차폐 효과에 대한 유용성 평가)

  • Gim, Yang-Soo;Lee, Sun-Young;Lim, Suk-Gun;Gwak, Geun-Tak;Pak, Ju-Gyeong;Lee, Seung-Hoon;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Purpose: We evaluated the device that was created for maintaining the patient's setup and protecting the testicles from scattered radiation during treatment of carcinoma of the penis. Materials and Methods: The phantom testicles were made of vaseline cotton gauze and the device consisted of 5 mm of acryl box and 4 mm of lead shielding. $3{\times}3\;cm^2$, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$, $6{\times}6\;cm^2$, $7{\times}7\;cm^2$ field sizes were used for this study and measurement was made at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field for 10 times with lead shielding and without the shielding respectively. 200 cGy was delivered using 6 MV photons. Results: The scatted radiation without lead shielding at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field were 14.8-4.7 cGy with $3{\times}3\;cm^2$, 15.7-5.2 cGy with $4{\times}4\;cm^2$, 17.6-5.5 cGy with $5{\times}5\;cm^2$, 19.9-6.6 cGy with $6{\times}6\;cm^2$, 22.2-7.6 cGy with $7{\times}7\;cm^2$ and the measured dose without lead shielding were 7.1-2.6 cGy with $3{\times}3\;cm^2$, 8.9-3.6 cGy with $4{\times}4\;cm^2$, 12.3-4.8 cGy with $5{\times}5\;cm^2$, 14.6-5.0 cGy with $6{\times}6\;cm^2$ and 21.1~6.4 cGy with $7{\times}7\;cm^2$. As shown above, the scatted radiation decreased after using lead shielding. Depending of the range of field sizes, the resulting difference between without shielding values and with shielding values were: 7.8-1.1 cGy at 4 cm, 5.1-1.2 cGy at 5 cm, 3.8-1.1 cGy at 6 cm, 3.4-1.7 cGy at 7 cm, 2.8-1.7 cGy at 8 cm, 2.4-2.5 cGy at 9 cm and 2.1-1.8 cGy at 10 cm. In the situation as described above, the range in values depending on the distance was 7.8-1.1 cGy with $3{\times}3\;cm^2$, 6.9-1.6 cGy with $4{\times}4\;cm^2$, 5.3-0.8 cGy with $5{\times}5\;cm^2$, 5.3-1.5 cGy with $6{\times}6\;cm^2$ and 1.1-1.8 cGy with $7{\times}7\;cm^2$. Conclusion: Using the device we created to shield the testicles from scattered radiation during treatment of carcinoma of the penis, we have found that scattered radiation to the testicles is decreased by the phantom testicles, and by increasing the distance between the testicles and penis.

  • PDF

ART Outcomes in WHO Class I Anovulation: A Case-control Study (저성선자극호르몬 성선저하증 여성에서 보조생식술의 임신율)

  • Han, Ae-Ra;Park, Chan-Woo;Cha, Sun-Wha;Kim, Hye-Ok;Yang, Kwang-Moon;Kim, Jin-Young;Koong, Mi-Kyoung;Kang, Inn-Soo;Song, In-Ok
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.37 no.1
    • /
    • pp.49-56
    • /
    • 2010
  • Objective: To investigate assisted reproductive technology (ART) outcomes in women with WHO class I anovulation compared with control group. Design: Retrospective case-control study. Methods: Twenty-three infertile women with hypogonadotropic hypogonadism (H-H) who undertook ART procedure from August 2003 to January 2009 were enrolled in this study. A total of 59 cycles (H-H group) were included; Intra-uterine insemination with super-ovulation (SO-IUI, 32 cycles), in vitro fertilization with fresh embryo transfer (IVF-ET, 18 cycles) and subsequent frozenthawed embryo transfer (FET, 9 cycles). Age and BMI matched 146 cycles of infertile women were collected as control group; 64 cycles of unexplained infertile women for SO-IUI and 54 cycles of IVF-ET and 28 cycles of FET with tubal factor. We compared ART and pregnancy outcomes such as clinical pregnancy rate (CPR), clinical abortion rate (CAR), and live birth rate (LBR) between the two groups. Results: There was no difference in the mean age ($32.7{\pm}3.3$ vs. $32.6{\pm}2.7$ yrs) and BMI ($21.0{\pm}3.1$ vs. $20.8{\pm}3.1kg/m^2$) between two groups. Mean levels of basal LH, FSH, and $E_2$ in H-H group were $0.62{\pm}0.35$ mIU/ml, $2.60{\pm}2.30$ mIU/ml and $10.1{\pm}8.2$ pg/ml, respectively. For ovarian stimulation, H-H group needed higher total amount of gonadotropin injected and longer duration for ovarian stimulation (p<0.001). In SO-IUI cycles, there was no significant difference of CPR, CAR, and LBR between the two groups. In IVF-ET treatment, H-H group presented higher mean $E_2$ level on hCG day ($3104.8{\pm}1020.2$ pg/ml vs. $1878.3{\pm}1197.7$ pg/ml, p<0.001) with lower CPR (16.7 vs. 37.0%, p=0.11) and LBR (5.6 vs. 33.3%, p=0.02) and higher CAR (66.7 vs. 10.0%, p=0.02) compared with the control group. However, subsequent FET cycles showed no significant difference of CPR, CAR, and LBR between the two groups. Conclusion: H-H patients need higher dosage of gonadotropin and longer duration for ovarian stimulation compared with the control groups. Significantly poor pregnancy outcomes in IVF-ET cycles of H-H group may be due to detrimental endometrial factors caused by higher $E_2$ level and the absence of previous hormonal exposure on endometrium.

Radiation Therapy Using M3 Wax Bolus in Patients with Malignant Scalp Tumors (악성 두피 종양(Scalp) 환자의 M3 Wax Bolus를 이용한 방사선치료)

  • Kwon, Da Eun;Hwang, Ji Hye;Park, In Seo;Yang, Jun Cheol;Kim, Su Jin;You, Ah Young;Won, Young Jinn;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.75-81
    • /
    • 2019
  • Purpose: Helmet type bolus for 3D printer is being manufactured because of the disadvantages of Bolus materials when photon beam is used for the treatment of scalp malignancy. However, PLA, which is a used material, has a higher density than a tissue equivalent material and inconveniences occur when the patient wears PLA. In this study, we try to treat malignant scalp tumors by using M3 wax helmet with 3D printer. Methods and materials: For the modeling of the helmet type M3 wax, the head phantom was photographed by CT, which was acquired with a DICOM file. The part for helmet on the scalp was made with Helmet contour. The M3 Wax helmet was made by dissolving paraffin wax, mixing magnesium oxide and calcium carbonate, solidifying it in a PLA 3D helmet, and then eliminated PLA 3D Helmet of the surface. The treatment plan was based on Intensity-Modulated Radiation Therapy (IMRT) of 10 Portals, and the therapeutic dose was 200 cGy, using Analytical Anisotropic Algorithm (AAA) of Eclipse. Then, the dose was verified by using EBT3 film and Mosfet (Metal Oxide Semiconductor Field Effect Transistor: USA), and the IMRT plan was measured 3 times in 3 parts by reproducing the phantom of the head human model under the same condition with the CT simulation room. Results: The Hounsfield unit (HU) of the bolus measured by CT was $52{\pm}37.1$. The dose of TPS was 186.6 cGy, 193.2 cGy and 190.6 cGy at the M3 Wax bolus measurement points of A, B and C, and the dose measured three times at Mostet was $179.66{\pm}2.62cGy$, $184.33{\pm}1.24cGy$ and $195.33{\pm}1.69cGy$. And the error rates were -3.71 %, -4.59 %, and 2.48 %. The dose measured with EBT3 film was $182.00{\pm}1.63cGy$, $193.66{\pm}2.05cGy$ and $196{\pm}2.16cGy$. The error rates were -2.46 %, 0.23 % and 2.83 %. Conclusions: The thickness of the M3 wax bolus was 2 cm, which could help the treatment plan to be established by easily lowering the dose of the brain part. The maximum error rate of the scalp surface dose was measured within 5 % and generally within 3 %, even in the A, B, C measurements of dosimeters of EBT3 film and Mosfet in the treatment dose verification. The making period of M3 wax bolus is shorter, cheaper than that of 3D printer, can be reused and is very useful for the treatment of scalp malignancies as human tissue equivalent material. Therefore, we think that the use of casting type M3 wax bolus, which will complement the making period and cost of high capacity Bolus and Compensator in 3D printer, will increase later.