Compare to Evaluate the Imaging dose of MVCT and CBCT (Tomotherapy MVCT와 Linac CBCT의 Imaging dose 비교평가)

  • Yoon, Bo Reum;Hong, Mi Lan;Ahn, Jong Ho;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.83-89
    • /
    • 2014
  • Purpose : In case of the intensity modulated radiation therapy (IMRT) using Tomotherapy and linear accelerator (Linac), it was to compare and to evaluate the imaging dose of MVCT and CBCT that were performed daily for the correct set up of the patient. Materials and Methods : The human body model Phantom (Anderson rando Phantom, USA) was divided into the three parts as Head, Thorax, pelvis, and after GafChromic EBT3 film cut to the size of $0.5{\times}0.5cm2$.in the center of the recording area were situated on the ant, post, left, and right surface of the phantom and 2cm in depth from the ant, post, left, right, and center surface of the phantom, the surface dose and inner dose were measured repeatedly three times, respectively, using the tomotherapy (Hi Art) and the OBI of NovalisTx. The measured film calculated the output value by RIP version6.0 and then the average value of the dose was calculated by the one-way analysis of variance. Results : Using the human body model phantom, the results of MVCT and CBCT performance were that measurements of MVCT inner dose were showed $15.43cGy{\pm}6.05$ in the head, $16.62cGy{\pm}3.08$ in the thorax, $16.81cGy{\pm}5.24$ in the pelvis, and measurements of CBCT inner dose were showed $13.28{\pm}3.68$ in the head, from $13.66{\pm}4.04$ in the thorax, $15.52{\pm}3.52$ in the pelvis. The measurements of surface dose were showed in case of MVCT performance, $11.64{\pm}4.05$ in the head, $12.16{\pm}4.38$ in the thorax, $12.05{\pm}2.71$ in the pelvis, and in case of CBCT performance, $14.59{\pm}3.51$ in the head, $15.82{\pm}2.89$ in the thorax, $17.48{\pm}2.80$ in the pelvis, respectively. Conclusion : In case of Inner dose, the MVCT using MV energy showed higher than the CBCT using kV energy at 1.16 times in the head, at 1.22 times in the thorax, at 1.08 times in the pelvis, and in case of surface dose, the CBCT was higher than MVCT, at 1.25 times in the head, at 1.30 times in the thorax, at 1.45 times in the pelvis. Imaging dose was a small amount compared to the therapeutic dose but it was thought to affect partially to normal tissue because it was done in daily schedule. However, IMRT treatment was necessarily parallel with the IGRT treatment through the image-guide to minimize errors between planned and actual treatment. Thus, to minimize imaging dose that the patients receive, when planning the treatment, it should be set up a treatment plan considering imaging dose, or it must be performed by minimizing the scan range when shooting MVCT.

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.

Expression of Decidual Natural Killer (NK) Cells in Women of Recurrent Abortion with Increased Peripheral NK Cells (말초혈액자연살해세포가 증가된 반복유산 환자의 탈락막자연살해세포의 발현)

  • Yeon, Myeong-Jin;Yang, Kwang-Moon;Park, Chan-Woo;Song, In-Ok;Kang, Inn-Soo;Hong, Sung-Ran;Cho, Dong-Hee;Cho, Yong-Kyoon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.35 no.2
    • /
    • pp.119-129
    • /
    • 2008
  • Objective: The purpose of this study was to quantify decidual $CD56^+$ and $CD16^+$ NK cell subtype population and to evaluate the correlation between decidual NK cell expression and peripheral $CD56^+$ NK cell expression in women with a history of recurrent abortion and increased peripheral NK cells. Methods: Twenty-nine women with recurrent abortion and elevated peripheral $CD56^+$ NK cell percentage who had chromosomally normal conceptus were included in this study. Thirty-two women with recurrent abortion who had chromosomally abnormal conceptus were used as controls. Distribution of $CD56^+$ and $CD16^+$ NK cells in decidual tissues including implantation sites was examined by immunohistochemical staining. The degree of immunohistochemical staining was interpreted by score and percentage. Results: There was a significant difference in decidual $CD56^+$ NK cell score ($43.6{\pm}24.5$ vs. $23.9{\pm}16.3$ P =0.001) and $CD56^+$ NK cell percentage ($42.1{\pm}11.7$ vs. $33.9{\pm}15.8$ P =0.027) between increased peripheral NK cell group and control group. However, there was no statistically significant difference in decidual $CD16^+$ NK cell score ($18.7{\pm}9.5$ vs. $13.2{\pm}39.4$ P =0.108) and $CD16^+$ NK cell percentage ($24.7{\pm}5.9$ vs. $23.4{\pm}11.7$ P =0.599). There was no significant correlation between decidual NK cell score and peripheral NK cell percentage in increase peripheral NK cell group (peripheral $CD56^+$ NK cell percentage vs. decidual $CD56^+$ NK cell score, r=-0.016, P =0.932, peripheral $CD16^+$ NK cell percentage vs. decidual $CD16^+$ NK cell score, r=0.008, P =0.968). Conclusion: This study shows that $CD56^+$ decidual NK cells are increased in decidua of women exhibiting a history of recurrent abortion with increased $CD56^+$ peripheral NK cell. There was no significant correlation between decidual and peripheral NK cell increment in increase peripheral NK cell group. This study suggests the possibility that decidual NK cells may play an important role in the immune mechanism of recurrent abortion.

Study on the Content of ${NO_3}^-$ in Green Vegetable Juice by Different Sorts, Harvesting Time, Mixing Rate of Vegetable, Storage Condition and Manufacturers (채소 모재료의 종류, 수확시기별, 부위별 혼합비율, 저장조건 및 생산회사에 따른 녹즙의 ${NO_3}^-$ 함량차이)

  • Sohn, Sang-Mok;Yoon, Ji-Young
    • Korean Journal of Organic Agriculture
    • /
    • v.7 no.1
    • /
    • pp.91-103
    • /
    • 1998
  • After the consumption of green vegetable juice by Korean increase rapidly, the ${NO_3}^-$ intake through green vegetable juice have been ignored to consider for the calculation of daily ${NO_3}^-$ intake. It is necessary to collect the basic data on the ${NO_3}^-$ content in green vegetable juice by different sorts, harvesting time and mixing rate of vegetable, manufacturers and storage conditions for the next calculation of daily ${NO_3}^-$ intake for Korean. Followings are the research results from monitoring and laboratory experiment related with ${NO_3}^-$ and vitamine C in green vegetable juice. The ${NO_3}^-$ content of angelica plaant(tomorrow's leaf) and kale were higher in spring than those in summer and autumm. The highest value of ${NO_3}^-$ content in tomorrow's leaf and kale were 4.85 and 2.94 times higher compare to the lowest value. The average ${NO_3}^-$ content in the midribs of tomorrow's leaf and kale were 7.5 and 2.1 times higher than those in leafblades. It indicate the green vegetable juice made from leadblade of tomorrow's leaf and kale might be better compare to those from midrib in terms of ${NO_3}^-$ content. The content of ${NO_3}^-$ and vitamine C as affected by the timecourse after juice making were decreased rapidly compare to those by storage temperature in case of carrot, kale and cucumber juice. It show the positive comelation between the content of ${NO_3}^-$ and vitamine C in carrot, kale and cucumber juice regardless of room temperature(${NO_3}^-$) or cold temperature(${NO_3}^-$). The content of ${NO_3}^-$ and vitamine C of green vegetable juice by P company were the highest among the manufactuers. The lower content of ${NO_3}^-$ and vitamine C of green vegecable juice by TW company and GB company compare to P company is due to dilution with water to produce the juice. The content of ${NO_3}^-$ of green vegetable juice which were available in market showed 143ppm in carrot juice, 506ppm in tomorrow's leaf juice, 669ppm in wild water celery juice, 985ppm in kale juice, whereas the content of vitamine C were 43ppm in carrot juice, 289ppm in wild water celery juice, 353ppm in kale juice and 768ppm in tomorrow's leaf juice. It was calculated that people take 253mg by tomorrow's leaf juice, 335mg by wild water celery juice, 483mg by kale juice if they drink 500ml of green vegetable juice perday, and it suggest to excess 1.16, 1.53 and 2.21 times respectively only by green vegetable juice consumption.

  • PDF

Diagnostic Values of Abdominal Ultrasonography in Patients with Fever and Abdominal Symptoms (발열과 복부 증상을 주소로 하는 환아에서 복부 초음파 검사의 진단적 의의에 관한 연구)

  • Lee, Mi-Kyung;Im, Chang-Sung;Ahn, Sun-Mi;Kim, Chang-Hi;Lee, Dong-Jin;Kwan, Joong-Hyuck;Park, Yong-Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.2
    • /
    • pp.191-202
    • /
    • 1995
  • Purpose: Acute febrile illness in children frequently accompanies with abdominal symptoms such as vomiting, diarrhea, and abdominal pain, even if its etiology is not occured from the gastrointestinal tract. If the etiology of fever was unknown and the fever was accompanied with abdominal symptoms, we should be concerned about whether the etiology of fever was originated from the gastrointestinal tract or interpretated from the abnormality in the gastrointestinal tract. This study was performed to evaluate the diagnostic value of abdominal ultrasonography in patients with fever and abdominal symptoms. Methods: We reviewed retrospectively the medical records of abdominal ultrasonographic (US) findings of 60 cases of acute febrile illness with abdominal symptoms at department of Pediatrics, Ulsan Dongang General Hospital during the period from January 1994 to June 1995. Results: The abnormal abdominal US findings obtained were as follows. 1) The abnormal US findings were seen in 56 cases (93.3%). 2) The most common abnormal US finding was the enlarged mesenteric lymph nodes in 52 cases (86.7%) 3) The enlarged mesenteric lymph nodes with or without intra-abdominal fluid were seen in 30 cases (50.0%) of a wide variety of illnesses, so their diagnostic values were absent. 4) The enlarged mesenteric lymph nodes and splenomegaly with or without ileocecitis were seen in 7 cases. Among them, 4 cases (6.7%) were confirmed as typhoid fever. 5) The US findings in 6 cases of typhoid fever were the enlarged mesenteric lymph nodes in all cases (100%), splenomegaly in 4 cases (66.7%), ileocecitis in 1 case (16.7%), enlarged mesenteric lymph nodes and splenomegaly in 4 cases (66.7%), enlarged mesenteric lymph nodes, splenomegaly and ileocecitis in 1 cases (16.7%). 6) The enlarged mesenteric lymph nodes and the abnormalities around the appendix were seen in 7 cases (11.7%), which were confirmed as appendicitis all. 7) The thickening of wall in urinary bladder was seen in 2 cases (3.3%) of acute cystitis and acute hemorrhagic cystitis. 8) The subtle thickening of wall in colon was seen in 1 cases (1.7%) of shigellosis. Conclusions: The enlarged mesenteric lymph nodes, splenomegaly and ileocolitis on the abdominal ultrasonography in patients with fever and abdominal symptoms aree suggestive findings of typhoid fever. The enlarged mesenteric lymph nodes and the abnormalities around the appendix on abdominal ultrasonography make the rapid diagnosis of acute appendicitis and its complications, when physical examination is difficult in small children and diagnosis of their illnesses is obscure in patients with fever and abdominal pain.

  • PDF

Evaluation of a colloid gel(Slime) as a body compensator for radiotherapy (Colloid gel(Slime)의 방사선 치료 시 표면 보상체로서의 유용성 평가)

  • Lee, Hun Hee;Kim, Chan Kyu;Song, Kwan Soo;Bang, Mun Kyun;Kang, Dong Yun;Sin, Dong Ho;Lee, Du Heon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.191-199
    • /
    • 2018
  • Purpose : In this study, we evaluated the usefulness of colloid gel(slime) as a compensator for irregular patient surfaces in radiation therapy. Materials and Methods : For this study, colloid gel suitable for treatment was made and four experiments were conducted to evaluate the applicability of radiation therapy. Trilogy(Varian) and CT(SOMATOM, Siemens) were used as treatment equipment and CT equipment. First, the homogeneity according to the composition of colloid gel was measured using EBT3 Film(RIT). Second, the Hounsfield Unit(HU) value of colloid gel was measured and confirmed by CRIS phantom, Eclipse RTP(Eclipse 13.1, Varian) and CT. Third, to measure the deformation and degeneration of colloid gel during the treatment period, it was measured 3 times daily for 2 weeks using an ion chamber(PTW-30013, PTW). The fourth experiment was compared the treatment plan and measured dose distributions using bolus, rice, colloid gel and additional, dose profiles in an environment similar to actual treatment using our own acrylic phantom. Result : First experiment, density of the colloid gel cases 1, 2 and 3 was $1.02g/cm^3$, $0.99g/cm^3$ and $0.96g/cm^3$. When the homogeneity was measured at 6 MV and 9 MeV, case 1 was more homogeneous than the other cases, as 1.55 and 1.98. In the second experiment, the HU values of case 1, 2, 3 were 15 and when the treatment plan was compared with the measured doses, the difference was within 1 % at all 9, 12 MeV and a difference of -1.53 % and -1.56 % within the whole 2 % at 6 MV. In the third experiment, the dose change of colloid gel was measured to be about 1 % for 2 weeks. In the fourth experiment, the dose difference between the treatment plan and EBT3 film was similar for both colloid gel and bolus, rice at 6 MV. But colloid gel showed less dose difference than bolus and rice at 9 MeV. Also, dose profile of colloid gel showed a more uniform dose distribution than the bolus and rice. Conclusion : In this study, the density of colloid gel prepared for radiation therapy was $1.02g/cm^3$ similar to the density of water, and alteration or deformation was not observed during the radiotherapy process. Although we pay attention to the density when manufacturing colloid gel, it is sufficient in that it can deliver the dose uniformly through the compensation of the patient's body surface more than the bolus and rice, and can be manufactured at low cost. Further studies and studies for clinical applications are expected to be applicable to radiation therapy.

  • PDF

Evaluation of Combine IGRT using ExacTrac and CBCT In SBRT (정위적체부방사선치료시 ExacTrac과 CBCT를 이용한 Combine IGRT의 유용성 평가)

  • Ahn, Min Woo;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Geon Ho;Lee, Doo Sang;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.201-208
    • /
    • 2018
  • Purpose : The purpose of this study is to compare and analyze the set-up errors using the Combine IGRT with ExacTrac and CBCT phased in the treatment of Stereotatic Body Radiotherapy. Methods and materials : Patient who were treated Stereotatic Body Radiotherapy in the ulsan university hospital from May 2014 to november 2017 were classified as treatment area three brain, nine spine, three pelvis. First using ExacTrac Set-up error calibrated direction of Lateral(Lat), Longitudinal(Lng), Vertical(Vrt), Roll, Pitch, Yaw, after applied ExacTrac moving data in addition to use CBCT and set-up error calibrated direction of Lat, Lng, Vrt, Rotation(Rtn). Results : When using ExacTrac, the error in the brain region is Lat $0.18{\pm}0.25cm$, Lng $0.23{\pm}0.04cm$, Vrt $0.30{\pm}0.36cm$, Roll $0.36{\pm}0.21^{\circ}$, Pitch $1.72{\pm}0.62^{\circ}$, Yaw $1.80{\pm}1.21^{\circ}$, spine Lat $0.21{\pm}0.24cm$, Lng $0.27{\pm}0.36cm$, Vrt $0.26{\pm}0.42cm$, Roll $1.01{\pm}1.17^{\circ}$, Pitch $0.66{\pm}0.45^{\circ}$, Yaw $0.71{\pm}0.58^{\circ}$, pelvis Lat $0.20{\pm}0.16cm$, Lng $0.24{\pm}0.29cm$, Vrt $0.28{\pm}0.29cm$, Roll $0.83{\pm}0.21^{\circ}$, Pitch $0.57{\pm}0.45^{\circ}$, Yaw $0.52{\pm}0.27^{\circ}$ When CBCT is performed after the couch movement, the error in brain region is Lat $0.06{\pm}0.05cm$, Lng $0.07{\pm}0.06cm$, Vrt $0.00{\pm}0.00cm$, Rtn $0.0{\pm}0.0^{\circ}$, spine Lat $0.06{\pm}0.04cm$, Lng $0.16{\pm}0.30cm$, Vrt $0.08{\pm}0.08cm$, Rtn $0.00{\pm}0.00^{\circ}$, pelvis Lat $0.06{\pm}0.07cm$, Lng $0.04{\pm}0.05cm$, Vrt $0.06{\pm}0.04cm$, Rtn $0.0{\pm}0.0^{\circ}$. Conclusion : Combine IGRT with ExacTrac in addition to CBCT during Stereotatic Body Radiotherapy showed that it was possible to reduce the set-up error of patients compared to single ExacTrac. However, the application of Combine IGRT increases patient set-up verification time and absorption dose in the body for image acquisition. Therefore, depending on the patient's situation that using Combine IGRT to reduce the patient's set-up error can increase the radiation treatment effectiveness.

  • PDF

Effects of Y Chromosome Microdeletion on the Outcome of in vitro Fertilization (남성 불임 환자에서 Y 염색체 미세 결손이 체외 수정 결과에 미치는 영향)

  • Choi, Noh-Mi;Yang, Kwang-Moon;Kang, Inn-Soo;Seo, Ju-Tae;Song, In-Ok;Park, Chan-Woo;Lee, Hyoung-Song;Lee, Hyun-Joo;Ahn, Ka-Young;Hahn, Ho-Suap;Lee, Hee-Jung;Kim, Na-Young;Yu, Seung-Youn
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.34 no.1
    • /
    • pp.41-48
    • /
    • 2007
  • Objective: To determine whether the presence of Y-chromosome microdeletion affects the outcome of in vitro fertilization (IVF) and intracytoplasmic sperm injection (ICSI) program. Methods: Fourteen couples with microdeletion in azoospermic factor (AZF)c region who attempted IVF/ICSI or cryopreserved and thawed embryo transfer cycles were enrolled. All of the men showed severe oligoasthenoteratoazoospermia (OATS) or azoospermia. As a control, 12 couples with OATS or azoospermia and having normal Y-chromosome were included. Both groups were divided into two subgroups by sperm source used in ICSI such as those who underwent testicular sperm extraction (TESE) and those used ejaculate sperm. We retrospectively analyzed our database in respect to the IVF outcomes. The outcome measures were mean number of good quality embryos, fertilization rates, implantation rates, $\beta$-hCG positive rates, early pregnancy loss and live birth rates. Results: Mean number of good quality embryos, implantation rates, $\beta$-hCG positive rates, early pregnancy loss rates and live birth rates were not significantly different between Y-chromosome microdeletion and control groups. But, fertilization rates in the Y-chromosome microdeletion group (61.1%) was significantly lower than that of control group (79.8%, p=0.003). Also, the subgroup underwent TESE and having AZFc microdeletion showed significantly lower fertilization rates (52.9%) than the subgroup underwent TESE and having normal Y-chromosome (79.5%, p=0.008). Otherwise, in the subgroups used ejaculate sperm, fertilization rates were showed tendency toward lower in couples having Y-chromosome microdeletion than couples with normal Y-chromosome. (65.5% versus 79.9%, p=0.082). But, there was no significance statistically. Conclusions: In IVF/ICSI cycles using TESE sperm, presence of V-chromosome microdeletion may adversely affect to fertilization ability of injected sperm. But, in cases of ejaculate sperm available for ICSI, IVF outcome was not affected by presence of Y-chromosome AZFc microdeletion. However, more larger scaled prospective study was needed to support our results.

Evaluation of Metal Volume and Proton Dose Distribution Using MVCT for Head and Neck Proton Treatment Plan (두경부 양성자 치료계획 시 MVCT를 이용한 Metal Volume 평가 및 양성자 선량분포 평가)

  • Seo, Sung Gook;Kwon, Dong Yeol;Park, Se Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • Purpose: The size, shape, and volume of prosthetic appliance depend on the metal artifacts resulting from dental implant during head and neck treatment with radiation. This reduced the accuracy of contouring targets and surrounding normal tissues in radiation treatment plan. Therefore, the purpose of this study is to obtain the images of metal representing the size of tooth through MVCT, SMART-MAR CT and KVCT, evaluate the volumes, apply them into the proton therapy plan, and analyze the difference of dose distribution. Materials and Methods : Metal A ($0.5{\times}0.5{\times}0.5cm$), Metal B ($1{\times}1{\times}1cm$), and Metal C ($1{\times}2{\times}1cm$) similar in size to inlay, crown, and bridge taking the treatments used at the dentist's into account were made with Cerrobend ($9.64g/cm^3$). Metal was placed into the In House Head & Neck Phantom and by using CT Simulator (Discovery CT 590RT, GE, USA) the images of KVCT and SMART-MAR were obtained with slice thickness 1.25 mm. The images of MVCT were obtained in the same way with $RADIXACT^{(R)}$ Series (Accuracy $Precision^{(R)}$, USA). The images of metal obtained through MVCT, SMART-MAR CT, and KVCT were compared in both size of axis X, Y, and Z and volume based on the Autocontour Thresholds Raw Values from the computerized treatment planning equipment Pinnacle (Ver 9.10, Philips, Palo Alto, USA). The proton treatment plan (Ray station 5.1, RaySearch, USA) was set by fusing the contour of metal B ($1{\times}1{\times}1cm$) obtained from the above experiment by each CT into KVCT in order to compare the difference of dose distribution. Result: Referencing the actual sizes, it was appeared: Metal A (MVCT: 1.0 times, SMART-MAR CT: 1.84 times, and KVCT: 1.92 times), Metal B (MVCT: 1.02 times, SMART-MAR CT: 1.47 times, and KVCT: 1.82 times), and Metal C (MVCT: 1.0 times, SMART-MAR CT: 1.46 times, and KVCT: 1.66 times). MVCT was measured most similarly to the actual metal volume. As a result of measurement by applying the volume of metal B into proton treatment plan, the dose of $D_{99%}$ volume was measured as: MVCT: 3094 CcGE, SMART-MAR CT: 2902 CcGE, and KVCT: 2880 CcGE, against the reference 3082 CcGE Conclusion: Overall volume and axes X and Z were most identical to the actual sizes in MVCT and axis Y, which is in the superior-Inferior direction, was regular in length without differences in CT. The best dose distribution was shown in MVCT having similar size, shape, and volume of metal when treating head and neck protons. Thus it is thought that it would be very useful if the contour of prosthetic appliance using MVCT is applied into KVCT for proton treatment plan.

The study on the scattering ratio at the edge of the block according to the increasing block thickness in electron therapy (전자선 치료 시 차폐블록 두께 변화에 따른 블록 주변 선량에 관한 연구)

  • Park, Zi On;Gwak, Geun Tak;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Kim, Jung Soo;Kwon, Hyoung Cheol;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.57-65
    • /
    • 2019
  • Purpose: The purpose is to clarify the effect of additional scattering ratio on the edge of the block according to the increasing block thickness with low melting point lead alloy and pure lead in electron beam therapy. Methods and materials: $10{\times}10cm^2$ Shielding blocks made of low melting point lead alloy and pure lead were fabricated to shield mold frame half of applicator. Block thickness was 3, 5, 10, 15, 20 (mm) for each material. The common irradiation conditions were set at 6 MeV energy, 300 MU / Min dose rate, gantry angle of $0^{\circ}$, and dose of 100 MU. The relative scattering ratio with increasing block thickness was measured with a parallel plate type ion chamber(Exradin P11) and phantom(RW3) by varying the position of the shielding block(cone and on the phantom), the position of the measuring point(surface ans depth of $D_{max}$), and the block material(lead alloy and pure lead). Results : When (depth of measurement / block position / block material) was (surface / applicator / pure lead), the relative value(scattering ratio) was 15.33 nC(+0.33 %), 15.28 nC(0 %), 15.08 nC(-1.31 %), 15.05 nC(-1.51 %), 15.07 nC(-1.37 %) as the block thickness increased in order of 3, 5, 10, 15, 20 (mm) respectively. When it was (surface / applicator / alloy lead), the relative value(scattering ratio) was 15.19 nC(-0.59 %), 15.25 nC(-0.20 %), 15.15 nC(-0.85 %), 14.96 nC(-2.09 %), 15.15 nC(-0.85 %) respectively. When it was (surface / phantom / pure lead), the relative value(scattering ratio) was 15.62 nC(+2.23 %), 15.59 nC(+2.03 %), 15.53 nC(+1.67 %), 15.48 nC(+1.31 %), 15.34 nC(+0.39 %) respectively. When it was (surface / phantom / alloy lead), the relative value(scattering ratio) was 15.56 nC(+1.83 %), 15.55 nC(+1.77 %), 15.51 nC(+1.51 %), 15.42 nC(+0.92 %), 15.39 nC(+0.72 %) respectively. When it was (depth of $D_{max}$ / applicator / pure lead), the relative value(scattering ratio) was 16.70 nC(-10.87 %), 16.84 nC(-10.12 %), 16.72 nC(-10.78 %), 16.88 nC(-9.93 %), 16.90 nC(-9.82 %) respectively. When it was (depth of $D_{max}$ / applicator / alloy lead), the relative value(scattering ratio) was 16.83 nC(-10.19 %), 17.12 nC(-8.64 %), 16.89 nC(-9.87 %), 16.77 nC(-10.51 %), 16.52 nC(-11.85 %) respectively. When it was (depth of $D_{max}$ / phantom / pure lead), the relative value(scattering ratio) was 17.41 nC(-7.10 %), 17.45 nC(-6.88 %), 17.34 nC(-7.47 %), 17.42 nC(-7.04 %), 17.25 nC(-7.95 %) respectively. When it was (depth of $D_{max}$ / phantom / alloy lead), the relative value(scattering ratio) was 17.45 nC(-6.88 %), 17.44 nC(-6.94 %), 17.47 nC(-6.78 %), 17.43 nC(-6.99 %), 17.35 nC(-7.42 %) respectively. Conclusions: When performing electron therapy using a shielding block, the block position should be inserted applicator rather than the patient's body surface. The block thickness should be made to the minimum appropriate shielding thickness of each corresponding using energy. Also it is useful that the treatment should be performed considering the influence of scattering dose varying with distance from the edge of block.