• Title/Summary/Keyword: 모형교량

Search Result 275, Processing Time 0.022 seconds

Study on Fatigue Behavior and Rehabilitation of Stringer with Coped Section(I) -Experimental Study on Static and Fatigue Behavior- (절취부를 갖는 세로보의 피로거동과 보수·보강에 관한 연구(I) -정적거동 및 피로거동의 실험적 고찰-)

  • Hwang, Yoon Koog;Chang, Dong Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.363-375
    • /
    • 1997
  • This study encompasses the performance of static and fatigue test for the 8 large scale test specimens to clarify the fatigue behavior of coped stringer and the effect of the repair and strengthening on the damaged stringer of the floor system in steel railway bridges. For the purpose of the research, the actual stress wave for the existing bridge was measured, the basic stress range frequency histogram was made and the equivalent stress range was calculated. Using the result from the equivalent stress range made by adjusting the stress range, the static and fatigue test was carried out by identifying the previous rehabilitation and after. As the result of the static tests, it was revealed that the level of local stress under the S1 specimen test of the real equivalent stress range was similar to tensile strength of the test material, and it was consistent with the requirement of the initiation condition of the fatigue crack. Through the various rehabilitation methods to the damaged specimens, the effects of the repair and reinforcement were analyzed. According to the results of the repair of effect, bolting the high tension bolt over the stop hole was confirmed to be more adequate method than drilling only stop hole to delay the fatigue crack growth. Futhermore, in case of the stringer subjected by bending moment, the reinforcement over the upper flange side was determined to be a useful strengthening method, and the reinforcement to the web of the stringer was not appropriate to accomodate as a adequate strengthening method. Also it was confirmed that the category of the fatigue design for the coped stringer met with the category E specified on the fatigue design criteria of the Highway Standard Specification in Korea.

  • PDF

Aquatic Ecosystem Assessment and Habitat Improvement Alternative in Hongcheon River using Fish Community (어류군집을 이용한 홍천강의 수환경 평가 및 서식처 개선방안)

  • Kang, Hyeongsik;Hur, Jun Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5B
    • /
    • pp.331-343
    • /
    • 2012
  • In this study, the site investigation for fish was performed in the 15 km of Hongcheon river including Oancheon stream. The river ecosystem health was evaluated using the field data for fish. The field survey was carried out at 9 sites, 4 times from August to November 2011. The ecological diversity, including dominance, evenness, and richness and the ecological health using IBI and QHEI were evaluated. The result shows that the mean IBI in the 9 sites is in good-common condition, but the downtown section has a common-worse condition. The result evaluated by QHEI shows optimum-good condition. Also, the habitat suitability index for Pseudopuntungia tenuicorpa, which is one of endangered species, was evaluated, and then the environment flow was calculated by using the PHABSIM model. The previous research in the literature reports that Acheilognathus signifer, one of the endangered species, inhabited in Hongchen river. However, the existence of Acheilognathus signifer was not found in the recent research and this study. Thus, the physical habitat condition for Acheilognathus signifer was evaluated using the field data in the previous study. Also, the habitat improvement for Acheilognathus signifer in Hongcheon river was proposed.

Time-Space Analysis of Road Traffic Flows in Seoul (서울시 도로교통흐름에 대한 시.공간적 분석)

  • Lee, Keum-Sook;Min, Hee-Hwa;Park, So-Hyen
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.521-539
    • /
    • 2009
  • This study investigates the time-space characteristics of the road traffic flows in Seoul and the relationship with land use patterns. For the purpose, we analyze the road traffic data collected at 118 observation sites over Seoul City area since 1993. We examine the time-trend of the annual average traffic flows per day during the last fourteen years. Three different trends are revealed: rapid increase during the time period between 1993 and 1997, maintenance same level after sharp decrease between year 1997 and 1998, and gradual decrease after sharp decrease between year 2003 and 2004. The spatial distribution patterns of road traffic flows have also been changed significantly during the period. The traffic flows in the urban center have been declined gradually, while the traffic flows in the boundary area and southern CBDs have increased dramatically. In order to examine the relationship with the changes in the land-use patterns and road traffic flows, we analyze the changes in the spatial distribution patterns of population and industries. We developed three multiple linear regression models to test the relationships between the changes in the land-use variables and road traffic flows.

  • PDF

Strength Prediction of PSC Box Girder Diaphragms Using 3-Dimensional Grid Strut-Tie Model Approach (3차원 격자 스트럿-타이 모델 방법을 이용한 PSC 박스거더 격벽부의 강도예측)

  • Park, Jung Woong;Kim, Tae Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5A
    • /
    • pp.841-848
    • /
    • 2006
  • There is a complex variation of stress in PSC anchorage zones and box girder diaphragms because of large concentrated load by prestress. According to the AASHTO LFRD design code, three-dimensional effects due to concentrated jacking loads shall be investigated using three-dimensional analysis procedures or may be approximated by considering separate submodels for two or more planes. In this case, the interaction of the submodels should be considered, and the model loads and results should be consistent. However, box girder diaphragms are 3-dimensional disturbed region which requires a fully three-dimensional model, and two-dimensional models are not satisfactory to model the flow of forces in diaphragms. In this study, the strengths of the prestressed box girder diaphragms are predicted using the 3-dimensional grid strut-tie model approach, which were tested to failure in University of Texas. According to the analysis results, the 3-dimensional strut-tie model approach can be possibly applied to the analysis and design of PSC box girder anchorage zones as a reasonable computer-aided approach with satisfied accuracy.

An Experiment on Redundancy in Continuous Span Two-Girder Bridge - Effects of Lateral Bracing (연속 2-거더교의 여유도 평가 실험 - 수평브레이싱의 효과)

  • Park, Yong-Myung;Joe, Woom-Do-Ji;Hwang, Min-Oh;Yoon, Tae-Yang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.417-429
    • /
    • 2008
  • This paper presents an experimental result to evaluate the redundancy in continuous span two plate-girder bridges which are generally classified as a non-redundant load path structure. The experiments were performed when one of the two girders is seriously cracked. To estimate the effects of bottom lateral bracing on the redundancy, the experiment variable was considered as the bottom lateral bracing, and two 1/5-scaled bridge specimens with and without lateral bracing system were fabricated. The ultimate loading tests were conducted on the damaged specimens with an induced crack at a girder in the side span. The test results showed that the load carrying capacity of damaged specimen with bracing was about 1.2 times higher than that without bracing. To evaluate the redundancy in each specimen, numerical analysis was performed to calibrate the difference of dead load between the actual bridge and the test specimens. When the dead load calibration is considered, the results showed that a continuous span two-girder bridges have a reasonable redundancy even without lateral bracing. Especially, the level of redundancy is increased by about 1.8 times when the lateral bracing is provided.