• Title/Summary/Keyword: 모터구동밸브

Search Result 68, Processing Time 0.044 seconds

3-D Finite Element Stress Analysis for Fatigue Design and Evaluation;A Parametric Study of MOV(Motor Operated Valve) (피로설계 및 평가를 위한 3차원 유한요소 응력해석에 관한 고찰;모터구동밸브를 이용한 사례연구)

  • Kim, Hyeong-Keun;Lee, Sang-Min;Chang, Yoon-Suk;Choi, Jae-Boong;Kim, Young-Jin;Kim, Yun-Jae
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.142-147
    • /
    • 2004
  • In this paper, a new procedure is proposed to accomplish the primary plus secondary stress(P+Q) at the 'structural element' instead of 'transition element'. For the P+Q evaluation, the calculated stresses by FEA are linearized along a stress classification line to extract the stress category, then the stress intensity is calculated to compare with the $3S_{m}$ limit. Also, in this paper, the 'design by analysis' criteria, adopted fundamental concepts and a new approach to calculate $K_{e}$ factors are explained. The new procedure combined with 3-D FEA has been applied to motor operated valve in order to the over conservatism and the rack of margin. The evaluation results show a good applicability and can be utilized for fatigue life evaluation by using P+Q.

  • PDF

Weak Link Analysis of Motor Operated Gate Valves (모터 구동 게이트 밸브의 취약부 분석)

  • Bae, Yoon-Ho;Hong, Min-Ki;Lee, Kwang-Nam
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.328-332
    • /
    • 2001
  • The purpose of this paper is to address the structural integrity of the stem disc T-head connection of the motor operated valve assembly by comparing the previously developed methodology with the finite element analysis(FEA). From the experiences of the previously performed weak link analysis, the most of "weak links" when valve is opened are stem-disc T-head connections, and the bearing stress on the disc is the dominant stress. The results of FEA are compared with that of the classical approaches of the weak link analysis. The higher allowable thrust be represented by performing the elastic-plastic FEA.

  • PDF

Study on the Rate-of-Loading by the Differential Pressure of Motor Operated Gate Valves in Opening Stroke (모터구동 게이트밸브 열림행정시 차압 작용에 의한 부하율 연구)

  • Kim, Dae Woong;Park, Sung Ken;Jeoung, Rae Hyuck;Lee, Do Hwan;Hong, Sung Yull
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.166-171
    • /
    • 2004
  • The Rate-of-Loading(ROL) effect of motor operated gate valves causes a decrease in the thrust delivered at a specific torque by the actuator under dynamic flow ${\Delta}$P conditions as compared to the no-flow, static conditions. This effect needs to be studied for the quantitative evaluation of motor operated gate valve operability. This study is performed to verify the validity for the application of ROL in the evaluation of operability of motor operated gate valves for the opening stroke. The ROL is assessed on the basis of in-situ test data for the opening and closing strokes. The results show that the distribution of the ROL for the operling sake has a tendency to the negative value when DP is higher than 150psid.

  • PDF

Friction Torque Analysis of a Hydraulic Motor-Load System using Proportional Control Valve (비례제어밸브를 이용한 유압모터 부하계의 마찰토크 해석)

  • Yu, Hwan-Shin;Park, Hyung-Bae
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.5
    • /
    • pp.760-766
    • /
    • 2010
  • In this paper, The static friction torque and viscous friction torque including hydraulic motor-load system driven by hydraulic proportional control valve analysis. The basic experimental was performed toward characteristic in pressure and flow rate in hydraulic system energy. The variable of friction torque was experiment on brake pressure variable using pneumatic brake system. The analysis of nonlinear friction and linear friction was perform ed toward friction characteristic of hydraulic system.

Pressure Locking and Thermal Binding Analysis of the RHR Motor Operated Valve (잔열제거계통 모터구동밸브의 압력잠김 및 열고착 현상 분석)

  • Song, Eun-Sil;Kim, Tae-Il;Lee, Kwang-Nam
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.630-635
    • /
    • 2001
  • The stem thrust required to unwedging a gate valve is influenced by the pressure and temperature when the valve is closed and by the changes in these conditions between closure and opening. "Pressure Locking" and "Thennal Binding" refer to situations where pressure and temperature effects cause the unwedging load to be much higher than normal. A model of these phenomena has been developed. The effects of pressure and temperature are analyzed to determine the change in this disk-to-seat "interference". Flexibilities or Stiffness of the disk and body strongly influence the unwedging thrust. Calculation and limited comparison to data have been performed for the RHR motor operated valve designs and scenario. Pressure changes can increase the unwedging thrust when bonnet pressure exceeds the pressure in the adjacent piping and temperature changes can increase the unwedging thrust when a temperature change after closure produces an increase in the disk-to-seat interference.

  • PDF

Development of BLDC motor Controller for VVA Module of Gasoline Vehicle (가솔린 차량용 가변 밸브 BLDC 모터 제어기 개발)

  • Park, Joon Sung;Choi, Jun-Hyuk;Gu, Bon-Gwan;Kim, Jin-Hong;Jung, In-Soung
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.586-587
    • /
    • 2012
  • 자동차 산업에 있어서 반도체 기술발전과 더불어 차량 내 기능들이 효율성, 경제성 및 친환경적인 관심을 고려하여 기계식 방식에서 전력전자식 방식으로 대체되고 있는 실정이다. 엔진의 연비를 향상시키기 위해서는 엔진의 연소효율을 개선하거나, 엔진에서 발생되는 손실을 줄이는 것이 필요한데, VVA(Variable Valve Actuation, 가변 밸브 작동) 기술은 엔진 흡기 유동 강화, 펌핑 손실 저감, 기계적 마찰 손실 저감등을 통해 엔진의 연비를 향상시킬 수 있다. 또한 VVA 엔진을 장착한 차량은 차량의 발진 응답성이 향상되고, 배기가스 배출량을 줄일 수 있어 친환경 저연비 차량을 실현하는데 핵심 차량부품기술이다. 최근까지 차량의 전동기 구동의 경우 DC모터 방식이 많이 적용되어 왔으나 DC모터의 내구성 및 효율 등의 이유로 BLDC모터로 바뀌고 있는 추세이다. 본 논문에서는 이와 같은 VVA 기구의 적용을 위하여 BLDC모터 제어기를 개발하였다.

  • PDF

Analysis on the Dynamic Characteristics of a DDV Actuation System of a FBW Aircraft (FBW 항공기의 DDV 구동장치에 대한 운동특성 해석)

  • Nam, Yun-Su;Park, Hae-Gyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.3
    • /
    • pp.74-80
    • /
    • 2006
  • This paper deals with the control and fault monitoring of a DDV hydraulic actuation system. A hydraulic servo system has a nonlinear dynamics of an orifice flow through a valve spool. A full nonlinear model for a DDV actuation system is driven, and linearized to a simple model which is convenient for a control loop and fault monitor design. A top level requirement on the performance and safety for the actuation system is introduced. A control system and fault monitoring structure which can meet these requirements are discussed. A simulation package for a DDV actuation system which has a triplex redundant structure is developed.