• 제목/요약/키워드: 모세유관

검색결과 5건 처리시간 0.026초

저온온수 모세유관 바닥복사 난방시스템의 성능에 관한 실험적 연구 (Experimental Study on a Low-Temperature Hot Water Capillary Radiant Floor Heating System)

  • 조진균;박병용;이용준;정원호
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.68-82
    • /
    • 2018
  • Radiant floor heating systems with capillary tubes are energy saving systems in which hot water is circulated into capillary tube with a small diameter. In this study, the heating performance of capillary tube system is investigated in an experimental study and a simulation model. The results of the study showed that, the capillary tube radiant floor heating system maintains a more stable floor surface temperature in comparison a PB pipe system. In terms of energy consumption, the capillary tube radiant floor heating system proved to be more efficient than the PB pipe heating system at $40^{\circ}C$ of low temperature hot water supply. The difference between water temperature and room temperature can be held low for heating which saves energy. Low temperature radiant floor heating system with capillary tubes have significant advantages such as health improvement, low energy cost, optimum use of heat source(boiler) and higher operational efficiency.

폴리프로필렌 모세유관 냉방시스템의 적용에 관한 실험적 연구 (An Experimental Study on the Application of Polypropylene Capillary Tube Cooling System)

  • 이영주;김오봉;김광우;여명석
    • 설비공학논문집
    • /
    • 제17권9호
    • /
    • pp.873-881
    • /
    • 2005
  • In this study, we made RFC, RCC and NCC according to the method by which polypropylene capillary tube was adopted, and evaluated cooling performance of each system through model experiments. We also investigated an applicability of the combined use of radiant cooling and dehumidification system. The results are as follows: In case of normal cooling load, RFC and RCC maintained set temperature without a condensation. But, in case of peak cooling load, RFC and RCC resulted in the lack of cooling performance and caused a condensation at the radiation surface. Consequently, the only use of polypropylene capillary tube is considered not to be enough for cooling in real application. Using the combination of a dehumidification and radiant cooling system maintained the set temperature without a condensation. NCC kept the set temperature at anytime without a condensation. It is more economic than packaged air-conditioner system due to the cooling effect of the floor surface.

모세유관 바닥복사 냉·난방 시스템의 성능평가 (Performance Evaluation of the Capillary Tube Radiant Floor Cooling & Heating System)

  • 서유진;김태연;이승복
    • KIEAE Journal
    • /
    • 제12권4호
    • /
    • pp.89-95
    • /
    • 2012
  • At present, many countries are trying to reduce green gas emissions to mitigate the effects of these gases on climate change. Year after year, there have been efforts to cut energy use for heating and cooling. Heating and cooling systems, common in all forms of housing, are increasing due to the constant supply of new housing resulting from improvements in economic growth and the quality of life. Thus, studies related to the design of cooling and heating systems to improve energy efficiency are expanding. Among the new designs, radiant floor cooling and heating systems which use capillary tubes are becoming viable means of reducing energy use. Radiant floor cooling and heating systems which use capillary tubes are creative and sustainable systems in which cool and hot water is circulated into capillary tube which has small diameter. In this study, the cooling and heating performance of this type of capillary tube system is investigated in an experimental study and a simulation using TRNSYS. The results of the experimental study show that under a peak load, a capillary tube radiant floor cooling system using geothermal energy can achieve desired indoor temperature without an additional heat source. The set room air temperature is maintained while the floor surface temperature, PMV and PPD remain within the comfort range. Also, this system is more economic than a packaged air conditioner system due to its higher COP. The results of the simulation show that the capillary tube radiant floor heating system maintains set temperature more stable than a PB pipe radiant floor heating system due to its lower supply temperature of hot water. In terms of energy consumption, the capillary tube radiant floor heating system is more efficient than the PB pipe radiant floor heating system.

소아에 있어서 C-반응성 단백의 모세혈 및 정맥혈 검사의 비교평가 (Comparison of C-reactive Protein between Capillary and Venous Blood in Children)

  • 진지훈;정수호;홍영진;손병관;김순기
    • Pediatric Infection and Vaccine
    • /
    • 제17권2호
    • /
    • pp.101-107
    • /
    • 2010
  • 목적 : 감염이 있는 환자들을 진단하는데 있어 CRP 검사 결과는 치료의 방향을 결정하는데 많은 도움을 준다. 하지만 영 유아에게 있어서 채혈의 어려움 때문에, 정맥혈 검사를 대채할수 있는 모세혈 채혈이 시도되고 있다. 이번 연구에서는 모세혈 채혈을 통한 CRP 검사 결과가 정맥혈 검사 결과와 차이가 있는지 비교평가 하였다. 방법 : 인하대병원 응급의료센터, 소아청소년과에 내원하거나 입원한 100명(0-14세, 남녀 47 : 53)을 대상으로 정맥혈은 Hitachi 7180$^{TM}$ (Hitachi, Tokyo, Japan), 모세혈은 LC-178CRP$^{TM}$ (Horiba Ltd., Kyoto, Japan, LC-178CRP)장비를 사용해 검사하였다. 통계적 분석방법은 교차분석을 통하여 정맥혈과 모세혈의 CRP 판독차이를 검정하였으며, 회귀분석 및 Bland Altman plot 방법을 통하여 일치도를 평가하였다. 결과 : 교차분석으로 모세혈과 정맥혈 검사의 CRP 판독차이를 검정한 결과 일치도는 90.63%로 유관한 관계성이 있었다(P<0.0001). Bland Altman Plot으로 분석한 결과 95% 신뢰구간의 일치 한계선내에서 측정되었다. 단순회귀모형으로 분석한 결과 기울기($\beta$)는 1.3434였으며, 결정계수($R^2$)는 0.9888로 매우 높은 선형관계를 확인할 수 있었다. 또한 정맥혈에서의 값은 모세혈에서 시행한 값보다 평균적으로 높음을 확인할 수 있었다. 결론 : 모세혈의 CRP는 정맥혈과 매우 높은 상관관계를 보였다. 일반적으로 정맥혈 검사를 하는것이 더 좋겠지만, 채혈이 어려운 경우 LC-178CRP$^{TM}$를 이용한 모세혈에서의 채혈은 정맥혈 검사를 대신할 수 있는 간편한 방법으로 생각된다.